DMC40202NY-LY-AFE [OPTREX]

LCD Module Specification; 液晶显示模块规格
DMC40202NY-LY-AFE
型号: DMC40202NY-LY-AFE
厂家: OPTREX CORPORATION    OPTREX CORPORATION
描述:

LCD Module Specification
液晶显示模块规格

CD
文件: 总16页 (文件大小:178K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Approved by  
Checked by  
Checked by  
Prepared by  
Production Div.  
Quality Assurance Div.  
Design Engineering Div.  
Production Div.  
First Edition  
Jul 9, 1999  
Final Revision  
*******  
LCD Module Specification  
Type No.  
DMC40202NY-LY-AFE  
Table of Contents  
1. General Specifications .............................................................................2  
2. Electrical Specifications...........................................................................3  
3. Optical Specifications ..............................................................................6  
4. I/O Terminal.............................................................................................8  
5. Test..........................................................................................................10  
6. Appearance Standards............................................................................11  
7. Code System of Production Lot ..........................................................14  
8. Type Number..........................................................................................14  
9. Applying Precautions.............................................................................14  
10. Precautions Relating Product Handling................................................15  
11. Warranty..................................................................................................16  
Revision History  
Rev.  
Date  
Page  
Comment  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 1/16  
OPTREX  
1. General Specifications  
Operating Temp.  
Storage Temp.  
Display Format  
Display Fonts  
Viewing Area  
Outline Dimensions  
Weight  
min. 0℃ ~ max. 50℃  
min. -20℃ ~ max. 70℃  
40 characters × 2 lines  
5 × 8 dots ( 1 character )  
152.5 (W) × 16.5 (H) mm  
182.0 (W) × 34.5 (H) × (15.1) (D) mm  
80g max.  
LCD Type  
NTD-7263  
( STN / Yellow-mode / Transmissive )  
Viewing Angle  
Backlight  
6:00  
LED Backlight / Yellow-green  
Drawings  
Dimensional Outline  
UE-301034  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 2/16  
OPTREX  
2.Electrical Specifications  
2.1.Absolute Maximum Ratings  
VSS=0V  
Units  
V
Parameter  
Supply Voltage  
(Logic)  
Symbol  
Conditions  
Min.  
-0.3  
Max.  
7.0  
VDD-VSS  
Supply Voltage  
(LCD Drive)  
Input Voltage  
VDD-VEE  
0
13.0  
V
V
VI  
-0.3  
VDD+0.3  
2.2.DC Characteristics  
Ta=25, VSS=0V  
Parameter  
Supply Voltage  
(Logic)  
Symbol  
Conditions  
Min.  
4.5  
Typ.  
Max.  
5.5  
Units  
V
VDD-VSS  
Supply Voltage  
(LCD Drive)  
High Level  
VDD-VEE  
Shown in 3.1  
V
V
VIH  
VDD=5.0V±10%  
VDD=5.0V±10%  
IOH=-0.205mA  
IOL=1.2mA  
2.2  
-0.3  
2.4  
2.0  
VDD  
0.6  
Input Voltage  
Low Level  
VIL  
V
Input Voltage  
High Level  
VOH  
V
Output Voltage  
Low Level  
VOL  
0.4  
5.0  
V
Output Voltage  
Supply Current  
IDD  
VDD-VSS=5.0V  
mA  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 3/16  
OPTREX  
2.3.AC Characteristics  
VDD=5.0V±10%  
Parameter  
Enable Cycle Time  
Symbol  
tCYC  
Conditions  
Fig.1, 2  
Fig.1, 2  
Fig.1, 2  
Fig.1, 2  
Fig.1, 2  
Fig.1  
Min.  
500  
230  
Max.  
Units  
ns  
20  
160  
Enable Pulse Width  
Enable Rise/Fall Time  
Address Setup Time  
Address Hold Time  
PWEH  
ns  
t t  
Er, Ef  
ns  
tAS  
tAH  
40  
ns  
10  
ns  
tDSW  
tDHW  
tDDR  
tDHR  
Write Data Setup Time  
Write Data Hold Time  
Read Data Delay Time  
Read Data Hold Time  
80  
ns  
Fig.1  
10  
ns  
Fig.2  
ns  
Fig.2  
5
ns  
V
V
IH  
IH  
RS  
R/W  
E
VIL  
VIL  
tAS  
tAH  
VIL  
VIL  
PWEH  
r
tE  
t
Ef  
VIH  
VIH  
VIL  
VIL  
VIL  
tDSW  
tDHW  
VIH  
VIL  
VIH  
VIL  
DB0 DB7  
Valid Data  
tCYC  
Fig.1 Write Operation Timing  
V
V
IH  
IH  
RS  
R/W  
E
VIL  
VIL  
tAS  
tAH  
VIH  
VIH  
PWEH  
r
tE  
f
tE  
VIH  
VIH  
VIL  
VIL  
VIL  
tDDR  
tDHR  
VOH  
VOL  
VOH  
VOL  
DB0 DB7  
Valid Data  
tCYC  
Fig.2 Read Operation Timing  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 4/16  
OPTREX  
2.4.Lighting Specifications  
2.4.1.Absolute Maximum Ratings  
Ta=25℃  
Units  
mA  
Parameter  
Foward Current  
Symbol  
IF  
Conditions  
Note 1  
Min.  
Typ.  
Max.  
500  
8
Reverse Voltage  
VR  
V
LED Power Dissipation  
PD  
2.1  
W
Note 1 : Refer to the foward current derating curve.  
IF (mA)  
500  
292  
0
25  
50  
Ta ()  
2.4.2.Operating Characteristics  
Ta=25℃  
Units  
V
Parameter  
Foward Voltage  
Luminance of  
Symbol  
Conditions  
IF=250mA  
IF=250mA  
Min.  
3.8  
Typ.  
4.0  
Max.  
4.2  
VF  
L
55  
cd/㎡  
Backlight Surface  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 5/16  
OPTREX  
3.Optical Specifications  
3.1.LCD Driving Voltage  
Parameter  
Recommended  
LCD Driving Voltage  
Note 1  
Symbol  
Conditions  
Ta= 0℃  
Min.  
Typ.  
Max.  
5.4  
Units  
V
VDD-VEE  
Ta=25℃  
Ta=50℃  
4.4  
4.2  
4.7  
5.0  
V
V
Note 1 :  
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of  
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and  
response time are not guaranteed over the entire range.  
3.2.Optical Characteristics  
Ta=25, 1/16 Duty, 1/4.5 Bias, VD=4.7V (Note 4), θ= 0 , φ=-゚  
Parameter  
Symbol  
CR  
Conditions  
Min.  
Typ.  
12  
Max.  
Units  
Contrast Ratio  
Viewing Angle  
Note 1  
θ= 0 , φ=-゚  
Shown in 3.3  
Response  
Time  
Rise Note 2  
Decay Note 3  
TON  
130  
180  
200  
280  
ms  
ms  
TOFF  
Note 1 : Contrast ratio is definded as follows.  
CR = LOFF / LON  
LON : Luminance of the ON segments  
OFF : Luminance of the OFF segments  
L
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON  
signal is applied.  
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF  
signal is applied.  
Note 4 : Definition of Driving Voltage VD  
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at  
1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded  
as follows.  
VD = (Vth1+Vth2) / 2  
Vth1 : The voltage VO-P that should provide 50% of the saturation level in the luminance at  
the segment which the ON signal is applied to.  
Vth2 : The voltage VO-P that should provide 50% of the saturation level in the luminance at  
the segment which the OFF signal is applied to.  
VO-P  
×
( B-2 ) VO-P / B  
×
1 / ( fF A )  
1 / fF  
ON SIGNAL  
OFF SIGNAL  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 6/16  
OPTREX  
3.3.Definition of Viewing Angle and Optimum Viewing Area  
Point shows the point where contrast ratio is measured. : θ= 0 , φ=-゚  
f
Driving condition : 1/16 Duty, 1/4.5 Bias, VD=4.7V, F=84.4Hz  
90  
45 ゚  
135 ゚  
θ
90 ゚  
φ
10 20 30 40 50  
(φ= 0 ゚)  
180 ゚  
θ
φ
180 ゚  
0 ゚  
225 ゚  
Area  
315 ゚  
270 ゚  
270 ゚  
shows typ. CR2  
3.4.System Block Diagram  
Temperature Chamber  
θ φ  
, )  
Rotation Table (  
Photometer  
#1980A WB  
LCD  
φ
Optical Fiber  
θ
Control Unit &  
Computer  
Waveform Generator  
Halogen bulb  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 7/16  
OPTREX  
4.I/O Terminal  
4.1.Pin Assignment  
No.  
1
Symbol  
Level  
Function  
VSS  
Power Supply (0V, GND)  
Power Supply for Logic  
VDD  
2
VEE  
Power Supply for LCD Drive  
Register Select Signal  
3
RS  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
H / L  
4
R/W  
Read/Write Select Signal H : Read L : Write  
Enable Signal (No pull-up Resister)  
Data Bus Line / Non-connection at 4-bit operation  
Data Bus Line / Non-connection at 4-bit operation  
Data Bus Line / Non-connection at 4-bit operation  
Data Bus Line / Non-connection at 4-bit operation  
Data Bus Line  
5
E
DB0  
6
7
DB1  
8
DB2  
9
DB3  
10  
11  
12  
13  
14  
15  
16  
DB4  
DB5  
Data Bus Line  
DB6  
Data Bus Line  
DB7  
Data Bus Line  
LED CATHODE  
LED ANODE  
LED Cathode Terminal  
LED Anode Terminal  
4.2.Example of Power Supply  
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance  
of the driving voltage and its temperature dependence.  
VDD  
VSS  
VEE  
VDD(+Voltage)  
VR  
MODULE  
VSS (0V)  
VR=1020KΩ  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 8/16  
OPTREX  
4.3.Block Diagram  
COM 16  
SEG 40  
4
L C D P  
8
DB7  
DB0  
E
40 characters × 2 lines  
Control LSI  
HCD44780  
or equivalent  
SEG 160  
R/W  
RS  
Column Driver  
KS0063B × 2  
or equivalent  
VDD  
VSS  
VEE  
Bias Circuit  
To LSI  
LED ANODE  
LED Backlight  
LED CATHODE  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 9/16  
OPTREX  
5.Test  
No change on display and in operation under the following test condition.  
No.  
1
Parameter  
Conditions  
50℃±2, 96hrs (operation state)  
0℃±2, 96hrs (operation state)  
70℃±2, 96hrs  
Notes  
High Temperature Operating  
Low Temperature Operating  
High Temperature Storage  
Low Temperature Storage  
Damp Proof Test  
2
3
4
3
4
-20℃±2, 96hrs  
3, 4  
3, 4  
5
5
40℃±2, 9095%RH, 96hrs  
Total fixed amplitude : 1.5mm  
Vibration Frequency : 1055Hz  
One cycle 60 seconds to 3 directions of X, Y, Z for  
each 15 minutes  
6
Vibration Test  
7
Shock Test  
To be measured after dropping from 60cm high on  
the concrete surface in packing state.  
Dropping method corner dropping  
F
A corner : once  
E
Edge dropping  
B,C,D edge : once  
D
A
G
C
B
Face dropping  
E,F,G face : once  
60cm  
Concrete Surface  
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.  
Temperature : 20±5℃  
Humidity  
: 65±5%  
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.  
Note 3 : No dew condensation to be observed.  
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity  
after removed from the test chamber.  
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 10/16  
OPTREX  
6.Appearance Standards  
6.1.Inspection conditions  
The LCD shall be inspected under 40W white fluorescent light.  
The distance between the eyes and the sample shall be more than 30cm.  
All directions for inspecting the sample should be within 45 against perpendicular line.  
45  
6.2.Definition of applicable Zones  
A Zone  
B Zone  
C Zone  
Bezel Flame  
A Zone : Active display area  
B Zone : Area from outside of "A Zone" to validity viewing area  
C Zone : Rest parts  
A Zone + B Zone = Validity viewing area  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 11/16  
OPTREX  
6.3.Standards  
No.  
1
Parameter  
Black and  
White Spots,  
Criteria  
(1) Round Shape  
Dimension (mm)  
Zone  
Acceptable Number  
Foreign Substances  
A
*
5
0
0
B
*
5
1
0
C
*
*
*
*
D 0.1  
0.1 D 0.2  
0.2 D 0.3  
0.3 D  
D = ( Long + Short ) / 2  
(2) Line Shape  
Zone  
* : Disregard  
Acceptable Number  
X(mm)  
Y(mm)  
0.02W  
A
*
3
1
0
B
C
*
*
*
*
*
2.0L  
0.03W  
0.04W  
0.05W  
0.05W  
3
1.0L  
1.0L  
2
2
In the same way (1)  
X : Length Y : Width  
* : Disregard  
Total defects shall not exceed 5.  
2
Air Bubbles  
(between glass  
& polarizer)  
Zone  
Dimension (mm)  
Acceptable Number  
A
*
2
1
0
B
*
3
2
1
C
*
*
*
*
D 0.15  
0.15D 0.3  
0.3 D 0.5  
0.5 D 1.0  
* : Disregard  
Total defects shall not exceed 3.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 12/16  
OPTREX  
No.  
3
Parameter  
Criteria  
The Shape of Dot  
(1) Dot Shape (with Dent)  
0.15  
As per the sketch of left hand.  
(2) Dot Shape (with Projection)  
Should not be connected to next dot.  
(3) Pin Hole  
X
(X+Y) / 20.2mm  
Y
(Less than 0.1mm is no counted.)  
Total defects shall not exceed 5.  
Not to be conspicuous defects.  
4
5
Polarizer Scratches  
Polarizer Dirts  
If the stains are removed easily from LCDP surface, the module is not  
defective.  
6
Color Variation  
Not to be conspicuous defects.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 13/16  
OPTREX  
7.Code System of Production Lot  
The production lot of module is specified as follows.  
Factory Number (Numeral)  
Factory Code (Alphabet)  
Production Week (15)  
Production Month (19, X, Y, Z)  
Production Year (Lower 2 digits)  
8.Type Number  
The type number of module is specified on the back of module as follows.  
DMC40202NY-LY-AFE  
Stamp or Seal  
9.Applying Precautions  
Please contact us when questions and/or new problems not specified in this specifications arise.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 14/16  
OPTREX  
10.Precautions Relating Product Handling  
The Following precautions will guide you in handling our product correctly.  
1) Liquid crystal display devices  
The liquid crystal display device panel used in the liquid crystal display module is made of plate  
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.  
The polarizer adhering to the surface of the LCD is made of a soft material.  
Guard against scratching it.  
2) Care of the liquid crystal display module against static electricity discharge.  
When working with the module, be sure to ground your body and any electrical equipment you may  
be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work  
tables against the hazards of electrical shock.  
Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other  
conductivity-treated fibers.  
Slowly and carefully remove the protective film from the LCD module, since this operation can  
generate static electricity.  
3) When the LCD module alone must be stored for long periods of time:  
Protect the modules from high temperature and humidity.  
Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.  
Protect the modules from excessive external forces.  
4) Use the module with a power supply that is equipped with an overcurrent protector circuit,  
since the module is not provided with this protective feature.  
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands  
or clothing come in contact with LCD fluid, wash immediately with soap.  
6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections  
between the metal holder and the PCB are not used. Please contact us to discuss appropriate  
ways to assure conductivity.  
7) For models which use CFL:  
High voltage of 1000V or greater is applied to the CFL cable connector area.  
Care should be taken not to touch connection areas to avoid burns.  
Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.  
The use of CFLs for extended periods of time at low temperatures will significantly shorten their  
service life.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 15/16  
OPTREX  
8) For models which use touch panels:  
Do not stack up modules since they can be damaged by components on neighboring modules.  
Do not place heavy objects on top of the product. This could cause glass breakage.  
9) For models which use COG,TAB,or COF:  
The mechanical strength of the product is low since the IC chip faces out unprotected from the rear.  
Be sure to protect the rear of the IC chip from external forces.  
Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical  
damage, avoid installation configurations in which the rear of the IC chip runs the risk of making  
any electrical contact.  
10) Models which use flexible cable, heat seal, or TAB:  
In order to maintain reliability, do not touch or hold by the connector area.  
Avoid any bending, pulling, or other excessive force, which can result in broken connections.  
11.Warranty  
This product has been manufactured to your company’s specifications as a part for use in your company’s  
general electronic products. It is guaranteed to perform according to delivery specifications. For any other  
use apart from general electronic equipment, we cannot take responsibility if the product is used in medical  
devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other  
applications in which there is a direct risk to human life and where extremely high levels of reliability are  
required. If the product is to be used in any of the above applications, we will need to enter into a separate  
product liability agreement.  
We cannot accept responsibility for any defect, which may arise from additional manufacturing of  
the product (including disassembly and reassembly), after product delivery.  
We cannot accept responsibility for any defect, which may arise after the application of strong  
external force to the product.  
We cannot accept responsibility for any defect, which may arise due to the application of static  
electricity after the product has passed your company’s acceptance inspection procedures.  
When the product is in CFL models, CFL service life and brightness will vary according to the  
performance of the inverter used, leaks, etc. We cannot accept responsibility for product  
performance, reliability, or defect, which may arise.  
We cannot accept responsibility for industrial property, which may arise through the use of your  
product, with exception to those issues relating directly to the structure or method of  
manufacturing of our product.  
Optrex will not be held responsible for any quality guarantee issue for defect products judged as  
Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex  
America, Optrex Europe, Display LC delivery which ever comes later.  
DMC40202NY-LY-AFE (AR) No.99-0205  
OPTREX CORPORATION  
Page 16/16  
OPTREX  

相关型号:

DMC40218

LCD Module
OPTREX

DMC4028SSD

40V COMPLEMENTARY DUAL ENHANCEMENT MODE MOSFET
DIODES

DMC4028SSD-13

Power Field-Effect Transistor, 5.4A I(D), 40V, 0.028ohm, 2-Element, N-Channel and P-Channel, Silicon, Metal-oxide Semiconductor FET, GREEN, PLASTIC, SOP-8
DIODES

DMC4029SK4-13

Small Signal Field-Effect Transistor,
DIODES

DMC4029SSD-13

Power Field-Effect Transistor
DIODES

DMC4029SSDQ-13

Power Field-Effect Transistor
DIODES

DMC4040SSD

40V COMPLEMENTARY PAIR ENHANCEMENT MODE MOSFET
DIODES

DMC4040SSD-13

40V COMPLEMENTARY PAIR ENHANCEMENT MODE MOSFET
DIODES

DMC4040SSDQ-13

Small Signal Field-Effect Transistor, 5.7A I(D), 40V, 2-Element, N-Channel and P-Channel, Silicon, Metal-oxide Semiconductor FET, SOP-8
DIODES

DMC40457

LCD Module
OPTREX

DMC4047LSD-13

Small Signal Field-Effect Transistor, 7A I(D), 40V, 2-Element, N-Channel and P-Channel, Silicon, Metal-oxide Semiconductor FET, SOP-8
DIODES

DMC4050SSDQ-13

Small Signal Field-Effect Transistor, 4.2A I(D), 40V, 2-Element, N-Channel and P-Channel, Silicon, Metal-oxide Semiconductor FET, SOP-8
DIODES