TFS403A [VECTRON]

Filter Specification; 过滤器规格
TFS403A
型号: TFS403A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器
文件: 总5页 (文件大小:73K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Tfs403A.doc  
version 1.3  
27.11.2002  
VI TELEFILTER  
Filter Specification  
TFS 403A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
23  
10 dBm  
C
Terminating impedances at f *:  
for input:  
140  
137  
-10,2 pF  
- 8,8 pF  
c
for output:  
Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 403A is the minimum of the pass band attenuation a  
. The minimum of the pass  
min  
rel  
band attenuation a  
min  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies  
e c  
at the 3 dB filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 403,5 MHz without tolerance. The given  
e
N
values for the relative attenuation a  
and for the group delay ripple have to be reached at the frequencies given below even if the centre  
rel  
frequency f is shifted due to the temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance  
c
f
for the centre frequency f .  
c
D a t a  
typ. Value  
Limit  
max. 5,5 dB  
Insertion loss  
a
e
4,8 dB  
(Reference level)  
Nominal frequency  
Pass band  
f
-
403,5 MHz  
1,5 MHz  
1,5 dB  
N
PB  
p-p  
-
f
N
Amplitude ripple in PB  
Relative attenuation  
0,8 dB  
max.  
a
rel  
f
.......  
f
±
1,5 MHz  
-
max.  
3
dB  
N
N
f
±
±
4,5 MHz ......  
f
±
±
19,5 MHz  
28  
40  
45  
dB  
dB  
dB  
min. 25  
min. 35  
min. 20  
dB  
dB  
dB  
N
N
N
f
19,5 MHz ....... f  
MHz  
100  
MHz  
N
2 f  
±
3
N
Return loss within PB  
12  
-
dB  
min.  
8
dB  
Input power level  
max. 10  
dBm  
Temperature coefficient of frequency Tcf  
Operating temperature range  
-20  
ppm/K  
-
- 10 °C.. + 60  
- 40 °C.. + 85  
-
°C  
°C  
Storage temperature range  
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
generated:  
checked / approved:  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs403A.doc  
version 1.3  
27.11.2002  
VI TELEFILTER  
Filter Specification  
TFS 403A  
2/5  
Construction, pin configuration and 50 - matching network  
(All dimensions in mm)  
5
7
1,78  
403A  
SQ 3,81  
+ 0,2 / -0,1  
1,78 0,6  
P48  
0,1  
1
3
2,54  
1,2 Max.  
Date code  
Date code:  
Year + week  
Pin 1 Input  
Pin 5 Output  
M
N
P
2000  
2001  
2002  
Pin 2 Input RF Return  
Pin 3 Ground  
Pin 4 Package Ground  
Pin 6 Ground  
Pin 7 Ground  
Pin 8 Package ground  
...  
50 Ohm Test circuit  
L1  
C1  
C2  
1
5
LB-OUT  
L3  
SAW  
L2  
6
2
1 : 1  
3,4,7,8  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs403A.doc  
version 1.3  
27.11.2002  
VI TELEFILTER  
Filter Specification  
TFS 403A  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
Do  
E
:
:
12  
4
± 0,3  
± 0,1  
Po  
P 2  
D
o
:
1,5 + 0,1  
E
F
:
1,75 ± 0,1  
Ao  
F
:
5,5 ± 0,05  
0,75  
G (min) :  
D 1  
CT  
W
Bo  
P2  
P1  
:
2
± 0,05  
± 0,1  
:
8
G
D1(min) :  
1,5  
Ao  
Bo  
CT  
:
:
4,3 ± 0,1  
4,3 ± 0,1  
9,5 ± 0,1  
P1  
COVER TAPE  
:
W
2
Reel (all dimensions in mm):  
A
:
:
330  
12,4 + 2,0  
W1  
W2 (max) :  
18,4  
C
N (min)  
C
:
50  
A
N
:
13 -+0,5/ -0,2  
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs403A.doc  
version 1.3  
27.11.2002  
VI TELEFILTER  
Filter Specification  
TFS 403A  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs403A.doc  
version 1.3  
27.11.2002  
VI TELEFILTER  
Filter Specification  
TFS 403A  
5/5  
History  
Version  
1.0  
Reason of Changes  
Name  
Chilla  
Chilla  
Date  
generation of Development specificationaccording to customer requirements  
14.08.2002  
22.08.2002  
1.1  
add limit line 20 dB at 804-810 MHz  
1.2  
1.3  
limit line at 2 f ±3 MHz corrected  
Chilla  
26.08.2002  
27.11.2002  
N
adding typical values of relative attenuation and terminating impedance  
Pfeiffer  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS403_06

Filter specification
VECTRON

TFS408

Filter specification
VECTRON

TFS411

Filter specification
VECTRON

TFS411A

Filter specification
VECTRON

TFS416

Filter specification
VECTRON

TFS420A

TELEFILTER
ETC

TFS420A1

Filter specification
VECTRON

TFS420B

Filter specification
VECTRON

TFS420H

Filter specification
VECTRON

TFS421

Filter specification
VECTRON

TFS426

Filter specfication
VECTRON

TFS426C

Filter specification
VECTRON