TFS416 [VECTRON]

Filter specification; 过滤器规格
TFS416
型号: TFS416
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:335K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 416.doc  
Version 1.2  
12.09.2006  
VI TELEFILTER  
Filter specification  
TFS 416  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
200  
200  
Output:  
Characteristics  
Remark:  
The nominal frequency f is fixed at 416,0 MHz. The insertion loss a is defined as loss value determined at f All specified data are met within the  
N
e
N.  
operating temperature range.  
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
a
1,6  
dB  
max.  
3,5  
dB  
e
(reference level)  
Nominal frequency  
Centre frequency  
fN  
fC  
-
416,0  
MHz  
416,0  
MHz  
MHz  
Bandwidth  
BW  
3
dB  
9,7  
-
Absolute attenuation  
a
abs  
fN  
-
1,28 MHz  
2,5  
dB  
max.  
4,5  
dB  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
51,84 MHz  
52,00 MHz  
103,68 MHz  
104,00 MHz  
155,52 MHz  
156,00 MHz  
207,36 MHz  
208,00 MHz  
259,20 MHz  
260,00 MHz  
311,04 MHz  
312,00 MHz  
362,88 MHz  
364,00 MHz  
59  
59  
57  
57  
56  
56  
58  
58  
59  
59  
62  
62  
60  
60  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
50  
50  
50  
50  
50  
50  
50  
50  
51  
51  
51  
51  
52  
52  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
+
+
+
+
+
+
+
+
+
+
+
+
51,84 MHz  
52,00 MHz  
103,68 MHz  
104,00 MHz  
155,52 MHz  
156,00 MHz  
207,36 MHz  
208,00 MHz  
259,20 MHz  
260,00 MHz  
311,04 MHz  
312,00 MHz  
55  
55  
56  
56  
54  
54  
58  
58  
60  
60  
62  
62  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
48  
48  
48  
48  
48  
48  
48  
48  
49  
49  
50  
50  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
fN  
fN  
+
+
362,88 MHz  
364,00 MHz  
64  
64  
-
dB  
dB  
min.  
min.  
max.  
50  
50  
10  
dB  
dB  
Input power level  
dBm  
Operating temperature range  
OTR  
-
- 40 °C ... + 85 °C  
- 45 °C ... + 95 °C  
Storage temperature range  
-
Temperature coefficient of frequency  
- 32  
ppm/K  
TC  
*
f
*) f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).  
f
To  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 416.doc  
Version 1.2  
12.09.2006  
VI TELEFILTER  
Filter specification  
TFS 416  
2/5  
Filter characteristic  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
-80  
-90  
-100  
0
-0.5  
-1  
-1.5  
-2  
-2.5  
-3  
-3.5  
-4  
-4.5  
-5  
100  
200  
300  
400  
500  
600  
700  
800  
410 411 412 413 414 415 416 417 418 419 420  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
7
6
5
1
2
3
4
5
6
7
8
Ground  
Input  
Ground  
Ground  
Ground  
Output  
Ground  
Ground  
416  
U37  
8
2
3
1
Date code  
1
3
Date code: Year + week  
U
V
W
...  
2006  
2007  
2008  
7
5
0,6  
0,6  
200 Test circuit  
L1  
2
6
L2  
SAW  
1, 3, 4, 5, 7, 8  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 416.doc  
Version 1.2  
12.09.2006  
VI TELEFILTER  
Filter specification  
TFS 416  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: three times max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
9000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3  
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
3,50 ± 0,05  
0,75  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
2,00 ± 0,05  
4,00 ± 0,1  
1,50  
3,25 ± 0,1  
3,25 ± 0,1  
5,5 ± 0,1  
Ko  
Typ  
PIN Marker  
D1  
Ao  
Ct  
W
2
Reel (all dimensions in mm)  
A
W1  
:330  
: 8,4 +1,5/-0  
W2(max) : 14,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 416.doc  
Version 1.2  
12.09.2006  
VI TELEFILTER  
Filter specification  
TFS 416  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 416.doc  
Version 1.2  
12.09.2006  
VI TELEFILTER  
Filter specification  
TFS 416  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of development specification  
Name  
Date  
Strehl  
18.05.2006  
25.07.2006  
12.09.2006  
1.1  
- Add absolute attenuation  
Strehl  
1.2  
- Add typical values, add filter characteristic  
- Generation of filter specification  
Channaa  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS420A

TELEFILTER
ETC

TFS420A1

Filter specification
VECTRON

TFS420B

Filter specification
VECTRON

TFS420H

Filter specification
VECTRON

TFS421

Filter specification
VECTRON

TFS426

Filter specfication
VECTRON

TFS426C

Filter specification
VECTRON

TFS429

Filter specification
VECTRON

TFS430B

Filter Specification
VECTRON

TFS430C

Filter specification
VECTRON

TFS430D

Filter specification
VECTRON

TFS433AA

Filter specification
VECTRON