TFS416 [VECTRON]
Filter specification; 过滤器规格型号: | TFS416 |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:335K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 416.doc
Version 1.2
12.09.2006
VI TELEFILTER
Filter specification
TFS 416
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
200
200
Ω
Ω
Output:
Characteristics
Remark:
The nominal frequency f is fixed at 416,0 MHz. The insertion loss a is defined as loss value determined at f All specified data are met within the
N
e
N.
operating temperature range.
D a t a
typ. value
tolerance / limit
Insertion loss
a
1,6
dB
max.
3,5
dB
e
(reference level)
Nominal frequency
Centre frequency
fN
fC
-
416,0
MHz
416,0
MHz
MHz
Bandwidth
BW
3
dB
9,7
-
Absolute attenuation
a
abs
fN
-
1,28 MHz
2,5
dB
max.
4,5
dB
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
-
-
-
-
-
-
-
-
-
-
-
-
-
-
51,84 MHz
52,00 MHz
103,68 MHz
104,00 MHz
155,52 MHz
156,00 MHz
207,36 MHz
208,00 MHz
259,20 MHz
260,00 MHz
311,04 MHz
312,00 MHz
362,88 MHz
364,00 MHz
59
59
57
57
56
56
58
58
59
59
62
62
60
60
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
50
50
50
50
50
50
50
50
51
51
51
51
52
52
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
fN
+
+
+
+
+
+
+
+
+
+
+
+
51,84 MHz
52,00 MHz
103,68 MHz
104,00 MHz
155,52 MHz
156,00 MHz
207,36 MHz
208,00 MHz
259,20 MHz
260,00 MHz
311,04 MHz
312,00 MHz
55
55
56
56
54
54
58
58
60
60
62
62
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
48
48
48
48
48
48
48
48
49
49
50
50
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
fN
fN
+
+
362,88 MHz
364,00 MHz
64
64
-
dB
dB
min.
min.
max.
50
50
10
dB
dB
Input power level
dBm
Operating temperature range
OTR
-
- 40 °C ... + 85 °C
- 45 °C ... + 95 °C
Storage temperature range
-
Temperature coefficient of frequency
- 32
ppm/K
TC
*
f
*) ∆f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).
f
To
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
12.09.2006
VI TELEFILTER
Filter specification
TFS 416
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
-0.5
-1
-1.5
-2
-2.5
-3
-3.5
-4
-4.5
-5
100
200
300
400
500
600
700
800
410 411 412 413 414 415 416 417 418 419 420
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
7
6
5
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
416
● U37
8
2
3
1
Date code
1
3
Date code: Year + week
U
V
W
...
2006
2007
2008
7
5
0,6
0,6
200 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
12.09.2006
VI TELEFILTER
Filter specification
TFS 416
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
9000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
3,50 ± 0,05
0,75
Po
P2
t
Do
Po
Do
E
F
G(min)
P2
P1
D1(min)
Ao
Bo
2,00 ± 0,05
4,00 ± 0,1
1,50
3,25 ± 0,1
3,25 ± 0,1
5,5 ± 0,1
Ko
Typ
PIN Marker
D1
Ao
Ct
W
2
Reel (all dimensions in mm)
A
W1
:330
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
C
: 50
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
12.09.2006
VI TELEFILTER
Filter specification
TFS 416
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 416.doc
Version 1.2
12.09.2006
VI TELEFILTER
Filter specification
TFS 416
5/5
History
Version
1.0
Reason of Changes
- Generation of development specification
Name
Date
Strehl
18.05.2006
25.07.2006
12.09.2006
1.1
- Add absolute attenuation
Strehl
1.2
- Add typical values, add filter characteristic
- Generation of filter specification
Channaa
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明