TFS420A [ETC]

TELEFILTER; TELEFILTER
TFS420A
型号: TFS420A
厂家: ETC    ETC
描述:

TELEFILTER
TELEFILTER

LTE
文件: 总4页 (文件大小:49K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
tfs 420A.doc  
Version 1.1  
06.01.02  
VI TELEFILTER  
Filter specification  
TFS 420A - 1/4  
1. Measurement condition  
Ambient temperature TA:  
Input power level:  
23 °C  
0
dBm  
Typical terminating impedances in fN:  
for input:  
for output:  
210 -5,38 pF.  
174 -3,99 pF.  
2. Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 420A is the minimum of the pass band attenuation a . The minimum of the pass  
min  
rel  
band attenuation a  
is defined as the insertion loss a . The nominal frequence fN is fixed at 420,0 MHz without tolerance or limit. The  
e
min  
c
reference frequence f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the  
insertion loss a . The temperature coefficient of frequency Tcf is valid both for the reference frequency f and the frequency response of the  
e
c
filter in the operating temperature range.  
Data  
typ. value  
tolerance / limit  
Insertion loss (Reference level)  
Nominal frequency  
a
21,5  
-
dB  
max 24  
420,0  
-
dB  
e
fN  
MHz  
Centre frequency  
Pass band (-1dB)  
f
at ambient temperature ( fCAT  
)
420,03  
MHz  
dB  
c
fN - 4,1 MHz ... fN + 4,1 MHz  
Amplitude ripple (p-p): fN ... fN ± 4,1 MHz  
Bandwidth at ambient temperature:  
0,4  
max 1,0  
dB  
1
3
dB - band width  
dB - band width  
9,14  
10,50  
14,23  
15,91  
MHz  
MHz  
MHz  
MHz  
20 dB - band width  
40 dB - band width  
Relative attenuation  
fN  
a
rel  
fN ± 4,1  
fN ± 5,0  
fN ± 10  
fN ± 100  
fN - 100  
fN + 300  
MHz  
MHz  
MHz  
MHz  
MHz  
MHz  
-
-
-
dB  
dB  
dB  
max. 1  
max. 3  
min. 3  
min. 40  
dB  
dB  
dB  
dB  
fN ± 4,1  
fN ± 5,5  
fN ± 10  
fN - 430  
fN + 100  
MHz  
MHz  
MHz  
MHz  
MHz  
45...60  
70...80  
60...70  
Average group delay in pass band:  
Group delay ripple in pass band (p-p):  
0,630  
40  
µs  
ns  
max 60  
ns  
Triple transit attenuation compared to main signal:  
Crosstalk  
Frequency inversion temperature ( To )  
Temperature coefficient of frequency ( Tcf )  
45...49  
50...54  
30  
dB  
dB  
°C  
ppm/K²  
- 0,050  
Frequency deviation of f over temperature T : *)  
f (Hz) = Tcf(ppm/K) x (T - To)² x fTo(MHz)  
c
c
Operating temperature range  
Storage temperature range  
Input power level  
-20 °C ... + 75 °C  
- 40 °C ... + 85 °C  
-
max. + 10  
dBm  
*) fTo is reference frequence f at frequency inversion temperature (To )  
c
Generated:  
Wadim P. Dunzow  
Dr. Bert Wall  
Checked/Approved:  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information  
tfs 420A.doc  
Version 1.1  
06.01.02  
VI TELEFILTER  
Filter specification  
TFS 420A - 2/4  
3. Package  
S 420 A  
H3  
1 Ground  
3 Input  
2 Ground  
4 Input RF Return  
6 Ground  
5 Ground  
7 Ground  
9 Output  
11 Ground  
8 Ground  
10 Output RF Return  
12 Ground  
4. 50 matching network:  
L2  
7 8 9  
L4  
6
5
4
10  
11  
12  
L3  
L1  
3 2
 
1  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information  
tfs 420A.doc  
Version 1.1  
06.01.02  
VI TELEFILTER  
Filter specification  
TFS 420A - 3/4  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
30g, 18 ms, half sine wave, 3 shocks each plane;  
IEC 68 - 2 - 27  
2. Vibration:  
3. Damp heat:  
10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes;  
IEC 68 - 2 - 6  
90 % to 95 % rel. humidity, 40 °C, 10 days;  
IEC 68 - 2 - 3  
4. Resistance to  
solder heat (Reflow):  
260 °C for 10 sec;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel: 3000  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
Do  
D1  
E
:
:
:
:
:
:
16  
4
± 0,3  
± 0,1  
Po  
P 2  
D
o
1,5 + 0,5  
1,5 + 0,5  
1,75 ± 0,1  
7,5 ± 0,1  
0,75  
E
F
Ao  
D1  
F
±
0,1  
13,4  
W
Bo  
G (min) :  
P2  
P1  
:
2
8
± 0,05  
± 0,1  
G
:
D1(min) : 1,5  
P1  
Ao  
Bo  
:
:
5,4 ± 0,1  
7,4 ± 0,1  
COVER TAPE  
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
:
16,4 +2  
W2 (max) :  
22,4  
N (min)  
C
>= 90  
C
A
:
13  
± 0,25  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information  
tfs 420A.doc  
Version 1.1  
06.01.02  
VI TELEFILTER  
Filter specification  
TFS 420A - 4/4  
Air reflow temperature conditions:  
1st and 2nd air reflow profile  
Name:  
Temperature:  
Time:  
pre-heating periods  
150 °C - 170 °C  
60 sec. - 90 sec.  
main-heating periods  
over 200 °C  
20 sec. - 25 sec.  
peak temperature  
255 °C ± 5 °C  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
____________________________________________________________________________________________________________________________________________________________________________________________________________  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information  

相关型号:

TFS420A1

Filter specification
VECTRON

TFS420B

Filter specification
VECTRON

TFS420H

Filter specification
VECTRON

TFS421

Filter specification
VECTRON

TFS426

Filter specfication
VECTRON

TFS426C

Filter specification
VECTRON

TFS429

Filter specification
VECTRON

TFS430B

Filter Specification
VECTRON

TFS430C

Filter specification
VECTRON

TFS430D

Filter specification
VECTRON

TFS433AA

Filter specification
VECTRON

TFS433B

Filter specification
VECTRON