TFS360F [VECTRON]
Filter Specification; 过滤器规格型号: | TFS360F |
厂家: | Vectron International, Inc |
描述: | Filter Specification |
文件: | 总5页 (文件大小:41K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
tfs360F.doc
version 1.3
27.11.2000
VI TELEFILTER
Filter Specification
TFS 360F
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
23 °C
dBm
0
580 Ohm // -0.85 pF
580 Ohm // -0.85 pF
91 nH
for output:
Coupling coil:
Characteristics
Remark:
Reference level for the relative attenuation a of the TFS360F is the minimum of the pass band attenuation a
. The minimum of the pass band
min
rel
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the
attenuation a
min
e
c
1.5 dB filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed on 360 MHz without tolerance. The given values for
the relative attenuation a and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency f is shifted
due to the temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .
e
N
rel
c
f
c
D a t a
typ. value
tolerance/limit
Insertion loss
(Reference level)
a
= a
min
3,3
dB
max.
5,0
dB
e
Nominal frequency
Centre frequency
f
f
-
360,00 MHz
N
360,015 MHz
c
Pass band ripple f ± 67,7kHz
BW
-
max.
1,5
dB
N
Relative attenuation
a
rel
f
f
f
f
f
f
f
f
f
±
±
-
0,4 MHz…f
0,6 MHz…f
0,8 MHz…f
3,0 MHz…f
MHz…f
MHz…f - 115
0,8 MHz…f
1,6 MHz…f
±
±
-
-
-
0,6 MHz
0,8 MHz
3,0 MHz
36...53
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
min.
29
dB
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
53
57...62
60...65
53...65
65...75
54
42
50
52
49
52
50
45
52
dB
dB
dB
dB
dB
dB
dB
dB
-
57
77
MHz
MHz
MHz
- 57
- 77
+
+
+
+
+
1,6 MHz *)
3,0 MHz
56
58...70
3,0 MHz…f + 115
MHz
N
Group delay ripple
67,76 kHz
GD
f
±
0.5
-
µs
max.
max.
2,0
µs
dBm
N
Input power level
5
Operating temperature range
Storage temperature range
- 20 °C ... + 75 °C
- 35 °C … + 85 °C
Temperature coefficient of frequency TC
- 0.036 ppm/K²
+ 20 °C
Frequency inversion temperature
*) One distortion with a 3 dB bandwidth of less than 60 kHz and a relative attenuation of more than 46 dB is allowed.
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
Vectron International Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs360F.doc
version 1.3
27.11.2000
VI TELEFILTER
Filter Specification
TFS 360F
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
5
7
1,78
360 F
M34
1
3
Da te c ode
2,54
1,1 Ma x.
Date code:
K
L
M
...
Year + week
Pin 1 Sym. Output
Pin 2 Sym. Output
Pin 3 External Coil
Pin 4 Package Ground
Pin 5 Sym. Input
Pin 6 Sym. Input
Pin 7 Ground
1998
1999
2000
Pin 8 Package ground
50 Ohm Test circuit 1
L1
L3
LB-IN
LB-OUT
6
1
SAW
C1
C2
2
5
L2
L4
3
L5
4, 7, 8
50 Ohm Test circuit 2
C1
C3
LB-IN
LB-OUT
6
5
1
L1
SAW
L2
2
C4
C2
3
L3
4, 7, 8
VI TELEFILTER
Potsdamer Straße 18
Vectron International Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs360F.doc
version 1.3
27.11.2000
VI TELEFILTER
Filter Specification
TFS 360F
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
Po
Do
E
:
:
:
:
:
12
4
± 0,3
± 0,1
Po
P 2
D
o
1,5 + 0,1
1,75 ± 0,1
E
F
Ao
F
5,5 ± 0,05
0,75
G (min) :
D1
CT
W
Bo
P2
P1
:
2
± 0,05
± 0,1
:
8
G
D1(min) :
1,5
Ao
Bo
CT
:
:
4,3 ± 0,1
4,3 ± 0,1
9,5 ± 0,1
P1
COVER TAPE
:
W
2
Reel (all dimensions in mm):
A
:
330
W1
:
:
12,4 + 0,2
W2 (max) :
18,4
N (min)
C
50
C
A
:
13
± 0,2
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
Vectron International Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs360F.doc
version 1.3
27.11.2000
VI TELEFILTER
Filter Specification
TFS 360F
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: pre-heating periods
main-heating periods
over 200 °C
peak temperature
255 °C ± 5 °C
Temperature: 150 °C - 170 °C
Time:
60 sec. - 90 sec.
20 sec. - 25 sec.
Chip-mount air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
10
20
30
40
50
60
70
80
90
100
110
120
130
VI TELEFILTER
Potsdamer Straße 18
Vectron International Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs360F.doc
version 1.3
27.11.2000
VI TELEFILTER
Filter Specification
TFS 360F
5/5
History
Version
1.0
Reason of Changes
- Generation of specification
Name
Date
Dr. Wall
Dr. Wall
Dr. Wall
22.08.2000
28.08.2000
18.10.2000
1.1
- Add values for termination impedance and coupling coil
1.2
- Pin numbers in package drawing added
- Tape and reel information added
- Typical filter data added
1.3
- Change values for termination impedances from 520 ohm // -0.85 pF
to 580 Ohm // -0.85 pF.
Dr. Wall
27.11.2000
VI TELEFILTER
Potsdamer Straße 18
Vectron International Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号: