TFS365B [VECTRON]
Filter specification; 过滤器规格![TFS365B](http://pdffile.icpdf.com/pdf1/p00166/img/icpdf/TFS36_929980_icpdf.jpg)
型号: | TFS365B |
厂家: | ![]() |
描述: | Filter specification |
文件: | 总5页 (文件大小:212K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
1/5
Measurement condition
Ambient temperature TA:
23 °C
Input power level:
0 dBm
Terminating impedances at f *):
input: 590 Ω// -6,6 pF
c
output: 260 Ω// -5,5 pF
Characteristics
Remark:
The reference level for the relative attenuation a of the TFS 365B is the minimum of the pass band attenuation a
. The minimum of the pass band
rel
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 0,8 dB
min
attenuation a
min
e
c
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 365 MHz without any tolerance. The given values for both the
e
N
relative attenuation a and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency f is shifted due to the
rel
c
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .
f
c
tolerance / limit
max. 14,5 dB
D a t a
typ. value
Insertion loss
(reference level)
a
9
dB
e
Nominal frequency
f
f
-
365
MHz
-
N
c
Centre frequency at ambient temperature
365,025 MHz
Pass band
PB
-
f
±
0,5 MHz
0,8 dB
N
Amplitude ripple within PB
0,3 dB
max.
In band ripple
(in any 112,5 kHz increment within the PB)
0,15 dB
max.
0,5 dB p-p
Relative attenuation
a
rel
f
.........
f
N
±
0,5
MHz
0,3 dB
max.
0,8 dB
N
f
f
f
±
-
1,2 MHz .........
3,0 MHz .........
1,5 MHz .........
0,3 MHz .........
3,2 MHz .........
f
N
f
N
f
N
f
N
±
-
1,5
1,5
3,2
3
MHz
MHz
MHz
MHz
GHz
40
44
43
55
54
dB
dB
dB
dB
dB
min. 35
min. 40
min. 40
min. 50
min. 50
dB
dB
dB
dB
dB
N
N
N
+
+
-
f
+
1,5
N
Group delay at f
1,6 µs
max.
2
µs
ns
N
Group delay ripple in PB
(in any 112,5 kHz increment within the PB)
90
ns
max. 120
Phase linearity in PB
1
-
deg p-p
max.
5
deg p-p
dBm**)
(in any 112,5 kHz increment within the PB)
Input power level
max. 20
Operating temperature range
Storage temperature range
Turnover temperature To
-
-
- 40 °C ... + 70
- 40 °C ... + 100
°C
°C
22
°C
-
-
Temperature coefficient of frequency TCf***
-0,04 ppm/K2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.15dBm only
***) ∆f(Hz) = TC (ppm/K²) x (T-T0)² x f (MHz)
f
To
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
2/5
Filter characteristic
0
0
-1
-2
-3
2.42
2.33
2.24
2.15
2.06
-10
-20
-30
B
d
B
d
-40
-50
-4
-5
s
n
i
n
i
µ
1.97
e
d
u
e
d
u
n
i
y
t
i
t
i
a
l
1.88
e
-60
-6
n
n
g
g
d
a
a
m
m
-70
-7
1.79
-80
-8
1.7
-90
-9
1.61
1.52
-100
-10
352.9 355.3 357.7 360.1 362.5 364.9 367.3 369.7 372.1 374.5 376.9
363.9 364.1 364.3 364.5 364.7 364.9 365.1 365.3 365.5 365.7 365.9
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
1
2
3
4
5
6
Input RF Return
Ground
Ground
Ground
Output
TFS 365B
●
S35
15,32+/-0,20
Output
7
8
9
10
Ground
Ground
Ground
Input
7,62 +/-0,20
1,91
Date code: Year + week
S
T
U
...
2004
2005
2006
1,02
50 Ω Test circuit
5
6
10
1
L4
L5
L6
2, 3, 4, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
2000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
P1
P2
Date Code
W
: 24,00 ± 0,3
Po
t
Do
Po
Do
E
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
F
: 11,50 ± 0,1
G(min)
P2
:
:
0,60
2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
Ao
:
:
1,50
7,10 ± 0,1
Ko
Typ
PIN Marker
D1
Ao
Bo
Ct
: 15,90 ± 0,1
: 21,5 ± 0,1
W
2
Reel (all dimensions in mm)
A
:330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
C
: 60
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature: 150 °C - 170 °C
Time: 60 sec. - 90 sec.
pre-heating periods
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
10
20
30
40
50
60
70
80
90
100
110
120
130
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
5/5
History
Version
1.0
Reason of Changes
Generate development specification
Name
Date
Roizengaft
Dr. Wall
Pfeiffer
Pfeiffer
22.12.2003
12.01.2004
16.02.2004
20.02.2004
1.1
Change of relative attenuation from 39 dB to 35 dB
1.2
Change of relative attenuation in between fc + 3MHz….fc + 3,2 MHz
1.3
terminating impedance (preliminary values) and typical vales added
triple transit limits removed
1.4
turn over temperature, temperature coefficient and filter characteristic added
Pfeiffer
24.08.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明