TFS374B [VECTRON]

Filter specification; 过滤器规格
TFS374B
型号: TFS374B
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器
文件: 总5页 (文件大小:168K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
File name: Tfs374B.doc  
version 2.0  
14.10.02  
VI TELEFILTER  
Filter specification  
TFS 374B  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances  
for input:  
23 °C  
5
dBm  
210 || -5.2 pF  
305 || -3.4 pF  
for output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a of TFS374B is the minimum of the pass band attenuation a  
. This value is defined as the  
min  
rel  
insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level  
e
c
relative to the insertion loss a . The given values for the relative attenuation a and the group delay ripple have to be reached at the frequencies  
rel  
e
given below, even if the centre frequency f is shifted due to the temperature coefficient of frequency TC in the operating temperature range and  
c
f
due to a production tolerance for the centre frequency f .  
c
D a t a  
typ. value  
tolerance/limit  
Insertion loss  
a
f
max. 10  
dB  
e
8,7  
dB  
(Reference level)  
Nominal frequency  
Centre frequency  
-
374,000 MHz  
-
N
f
374,000 MHz  
C
3 dB bandwidth  
BW  
23  
MHz  
min. 17  
MHz  
Relative attenuation  
a
rel  
fN  
fN  
... fN  
±
±
7
MHz  
0,8  
dB  
max  
max  
1
3
dB  
dB  
±
7
MHz ... fN  
8,5 MHz  
-
f
N - 100  
MHz ... fN  
MHz ... fN  
MHz ... fN  
-
33  
22  
MHz  
MHz  
54  
53  
40  
44  
48  
49  
dB  
dB  
dB  
dB  
dB  
dB  
min  
min  
min  
min  
min  
min  
45  
40  
30  
30  
35  
40  
dB  
dB  
dB  
dB  
dB  
dB  
fN  
fN  
-
-
33  
22  
-
-
16,5 MHz  
fN + 16,5 MHz ... fN  
+
+
+
22  
43  
MHz  
MHz  
MHz  
fN + 22  
fN + 43  
MHz ... fN  
MHz ... fN  
100  
Group delay ripple in f  
N
±
7
MHz  
40  
40  
ns  
max 100  
min 30  
ns  
Triple transit suppression  
dB  
dB  
Operating temperature range  
Storage temperature range  
Temperature coefficient of frequency  
Input power level  
- 10 °C ... + 85 °C  
- 40 °C ... + 85 °C  
-
TCf  
-94  
ppm/K  
max  
10  
dBm  
Generated:  
Checked / approved:  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
File name: Tfs374B.doc  
version 2.0  
14.10.02  
VI TELEFILTER  
Filter specification  
TFS 374B  
2/5  
Construction and pin configuration  
(All dimensions in mm)  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Ground  
+0.15  
Input RF-Return/ Input2  
5.0 SQ  
-0.1  
Input  
Ground  
Ground  
7
5
Output RF-Return/ Output2  
Output  
Ground  
S374B  
P18  
Date code:Year+week  
M
N
P
....  
2000  
2001  
2002  
....  
1
3
Date code  
50 Test circuit 1 ( unbalanced )  
L1  
L2  
3
7
6
C1  
C2  
SAW  
2
1,4,5,8  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-mail: tft@telefilter.com  
Phone: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of  
their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs374B.doc  
version 2.0  
14.10.02  
VI TELEFILTER  
Filter specification  
TFS 374B  
3/5  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page  
4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
:
12  
± 0,3  
P
o
2
P
Po  
:
4
± 0,1  
Do  
Do  
:
1,5 + 0,1  
E
F
A
o
E
:
1,75 ± 0,1  
5,5 ± 0,05  
0,75  
1
D
F
:
W
B
o
CT  
G (min) :  
P2  
P1  
:
2
8
± 0,05  
± 0,10  
G
:
P
1
D1(min) : 1,5  
COVER TAPE  
Ao  
Bo  
CT  
:
:
:
5,30 ± 0,1  
5,30 ± 0,1  
9,5 ± 0,1  
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
12,4 + 2,0  
18,4  
W2 (m ax) :  
N
C
(m in)  
:
50  
C
A
:
13 ± 0.2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Phone: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
E-mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of  
their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs374B.doc  
version 2.0  
14.10.02  
VI TELEFILTER  
Filter specification  
TFS 374B  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
temperature / °C  
23  
34  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
150  
20  
46  
160  
30  
60  
170  
40  
80  
180  
50  
103  
121  
134  
143  
150  
154  
156  
158  
159  
190  
60  
195  
70  
200  
80  
205  
90  
210  
100  
110  
120  
130  
215  
220  
230  
240  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
Phone: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
E-mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of  
their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs374B.doc  
version 2.0  
14.10.02  
VI TELEFILTER  
Filter specification  
TFS 374B  
5/5  
History  
version reason of changes  
name  
date  
1.0  
2.0  
generate specification  
Steiner  
Steiner  
02.05.2002  
14.10.2002  
terminating impedances added  
VI TELEFILTER  
Vectron International, Inc.  
267 Lowell Road  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Phone: (603) 598-0070 Fax: (603) 598-0075  
e-mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of  
their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS374D

Filter specification
VECTRON

TFS378

Filter Specification
VECTRON

TFS380A

Filter specification
VECTRON

TFS380B

TELEFILTER
ETC

TFS380C

VI TELEFILTER Filter specification
ETC

TFS380E

Filter Specification
VECTRON

TFS380G

Filter Specification
VECTRON

TFS380H

Development specification
VECTRON

TFS380K

Application Note
VECTRON

TFS380L

Filter specification
VECTRON

TFS380M

Filter specification
VECTRON

TFS380N

Filter specification
VECTRON