VI TELEFILTER  
Measurement condition  
Filter Specification  
TFS 37  
1/5  
Ambient temperature:  
Input power level:  
25  
0
C
dBm  
Terminating impedance:  
source: 50  
load:  
2
k
II 3 pF  
Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 37 is the insertion loss. The insertion loss a is defined as the insertion loss at the  
e
rel  
nominal frequency f  
.
N
D a t a  
typ. value  
limit  
Insertion Loss  
a
= a  
min  
12,7  
dB  
e
13,5  
± 1,5  
dB  
(Reference Level)  
Nominal Frequency  
Group delay ripple  
f
-
37,4  
-
MHz  
N
50  
ns  
Relative Attenuation  
a
rel  
picture carrier  
@ 38,90 MHz  
@ 33,90 MHz  
@ 34,47 MHz  
@ 33,40 MHz  
6,4  
7,0  
1,3  
27  
dB  
dB  
dB  
dB  
6
± 1  
± 1,2  
-
dB  
dB  
7,5  
color carrier  
sound carrier  
min.  
20  
-
-
dB  
@ 32,90 MHz  
@ 32,40 MHz  
54  
63  
52  
52  
50  
50  
48  
50  
55  
45  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
adjacent picture carrier @ 30,90 MHz  
@ 31,90 MHz  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
48  
48  
36  
48  
46  
46  
45  
38  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
@ 40,15 MHz  
adjacent sound carrier @ 40,40 MHz  
@ 41,40 MHz  
@ 40,90 MHz  
lower side lobe 25,00 ... 31,90 MHz  
upper side lobe 41,90 ... 45,00 MHz  
Reflected wave signal suppression  
49  
dB  
min.  
42  
dB  
1,2 µs...6,0 µs after main pulse  
(test pulse 250 ns, carrier frequency 37,40 MHz)  
Feedthrough signal suppression  
56  
dB  
min.  
50  
dB  
1,2 µs...1,1 µs before main pulse  
(test pulse 250 ns, carrier frequency 37,40 MHz)  
Operating Temperature Range  
-
-25 ...  
65  
° C  
Storage Temperature Range  
-
-40 ...  
85  
-
° C  
Temperature Coefficient of frequency TCf*  
- 0,072 ppm / K  
*)  
f (Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)  
c
generated:  
checked / approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
TFS37.doc  
version 1.2  
10.09.2003  
VI TELEFILTER  
Filter Specification  
TFS 37  
2/5  
Construction and pin connection  
(all dimensions in mm)  
1
2
3
4
5
6
7
8
input  
input - ground  
chip carrier - ground  
output  
output  
ground  
ground  
ground  
17,3 Max.  
date code  
TFS 37  
R37  
date code:  
N
P
year + week  
2001  
2002  
0,64 Max.  
0,34 Max.  
R
...  
2003  
10,16  
5,08  
3
1 2  
4 5  
7
9
8
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
TFS37.doc  
version 1.2  
10.09.2003  
VI TELEFILTER  
Filter Specification  
TFS 37  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
DIN IEC 286 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
1700  
min 300 mm  
min 500 mm  
min 300 mm  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
TFS37.doc  
version 1.2  
10.09.2003  
VI TELEFILTER  
Air reflow temperature conditions  
Filter Specification  
TFS 37  
4/5  
1st and 2nd air reflow profile  
Name:  
Temperature: 150 °C 170 °C  
Time: 60 sec. 90 sec.  
pre-heating periods  
main-heating periods  
over 200 °C  
20 sec. 25 sec.  
peak temperature  
255 °C ± 5 °C  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. Time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
Temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
Temperature / °C  
23  
34  
46  
60  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
90  
100  
110  
120  
130  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
TFS37.doc  
version 1.2  
10.09.2003  
VI TELEFILTER  
History  
Filter Specification  
TFS 37  
5/5  
Version  
1.0  
Reason of Changes  
Name  
Date  
generate specification  
change package  
Pfeiffer  
Pfeiffer  
Pfeiffer  
25.06.2002  
29.11.2002  
10.09.2003  
1.1  
1.2  
typical values added  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS370

Filter Specification
VECTRON

TFS374A

Filter specification
VECTRON

TFS374B

Filter specification
VECTRON

TFS374D

Filter specification
VECTRON

TFS378

Filter Specification
VECTRON

TFS380A

Filter specification
VECTRON

TFS380B

TELEFILTER
ETC

TFS380C

VI TELEFILTER Filter specification
ETC

TFS380E

Filter Specification
VECTRON

TFS380G

Filter Specification
VECTRON

TFS380H

Development specification
VECTRON

TFS380K

Application Note
VECTRON