Filter Specification  
TFS 36 C  
1/3  
1.  
Measurement condition :  
Ambient temperature TA:  
Input power level:  
23 °C  
0
dBm.  
Terminating impedances at f :  
c
for input:  
for output:  
30  
829 - 19,55 pF.  
1133 - 12,78 pF.  
Q-value of matching elements:  
2. Characteristics :  
Remark:  
Reference level for the relative attenuation a of the TFS 36C is the minimum of the pass band attenuation a  
. The minimum of the pass band  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the  
rel min  
attenuation a  
min  
e
c
40 dB filter attenuation level relative to the insertion loss a . The nominal frequency f  
is fixed on 36 MHz without tolerance. The temperature  
e
N
coefficient of frequency Tcf is valid both for the reference frequency f and the frequency response of the filter in the operating temperature range.  
c
The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.  
Data  
typ. value  
tolerance / limit  
max. 36 dB  
36 MHz  
Insertion loss (Reference level) a  
e
24...25 dB  
Nominal frequency :  
f
N
Centre frequency f at ambient temperature TA (fCAT  
)
36,005 MHz  
c
Pass band ( PB ) :  
f
- 0,75 MHz ... f + 0,75 MHz  
N
N
Bandwidth at operating temperature:  
1
dB - band width  
1,565 MHz  
2,245 MHz  
2,250 MHz  
min. 1,50 MHz  
max. 2,30 MHz  
max. 2,60 MHz  
40 dB - band width  
45 dB - band width  
Amplitude ripple in pass band (p-p) :  
0,7 dB  
max.  
1
dB  
Relative attenuation  
a
rel  
...  
f
f
f
f
± 0,75 MHz  
-
max.  
1
dB  
N
N
N
N
f
f
± 1,15 MHz ...  
± 1,3 MHz ...  
± 1,3  
± 35  
MHz  
MHz  
45 dB  
min. 40 dB  
min. 45 dB  
N
N
46...65 dB  
Group delay ( mean value in PB ):  
Group delay ripple in PB (p-p):  
4,08 µs  
100...120 ns  
Deviation from linear phase in PB (p-p):  
2,5...3,5° (r.m.s. 0,8 °)  
max. 4° p-p  
min. 55 dB  
Triple transit attenuation compared to main signal  
Crosstalk  
58...62 dB  
60...70 dB  
Frequency inversion temperature ( To )  
0 °C  
Temperature coefficient of frequency ( Tcf )  
0,036 ppm/°C  
Frequency deviation of f over temperature: * )  
f (Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)  
c
c
Operating temperature  
+ 45 °C  
- 25 °C ... + 85 °C  
Storage temperature range  
* ) fTo is reference frequence f at frequency inversion temperature (To )  
c
Generated:  
Dunzow W.P.  
Dr. Bert Wall  
Checked/Approved:  
VI TELEFILTER  
Vectron International, Inc.  
Potsdamer Straße 18  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs36c.doc  
Version 1.4  
28.06.2000.  
VI TELEFILTER  
Filter Specification  
TFS 36 C  
2/3  
3.  
Package :  
35 Max  
Datecode:  
K
Year+week  
1998  
L
M
....  
1999  
2000  
........  
TFS 36 C  
tft M25  
20,5 Max  
Pin 3  
Input  
Pin 2  
Input RF Return  
5,5  
5,5  
Pin 15  
Pin 14  
Output  
Output RF Return  
Pin 1, 4-12, 13, 16-24 Ground  
1
15,24  
24  
12  
13  
2,54  
11x2,54 = 27,94  
4.  
50 matching network :  
L1  
50 Ω  
1 2 3  
10 11 12  
C3  
L3  
L2  
C1p  
50 Ω  
C2p  
C4  
L4  
C2  
24 23 22  
15 14 13  
About values [ C1...4 , L1...4 and C1p , C2p ] see Application Note TFS 36C.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs36c.doc  
Version 1.4  
28.06.2000.  
VI TELEFILTER  
Filter Specification  
TFS 36 C  
3/3  
5.  
Soldering temperature conditions :  
Soldering temperature profile  
Name: pre-heating periods  
Temperature: 150 °C - 170 °C  
Time: 60 sec. - 90 sec.  
main-heating periods  
over 200 °C  
20 sec. - 25 sec.  
peak temperature  
255 °C ± 5 °C  
Soldering temperature profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the soldering process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Vectron International, Inc.  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Tfs36c.doc  
Version 1.4  
28.06.2000.  
VI TELEFILTER  
Filter Specification  
TFS 36 C  
4/3  
History  
Version  
1.0...1.3  
1.4  
Reason of Changes  
Name  
Date  
Generate Development Specification according to customer requirements.  
Dr. Wall  
12.12.1999  
28.06.2000  
Add typical values of Data.  
Add matching networks.  
Dunzow W.  
Add Termination Impedances.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS36D

Filter Specification
VECTRON

TFS36F

Filter Specification
VECTRON

TFS37

Filter Specification
VECTRON

TFS370

Filter Specification
VECTRON

TFS374A

Filter specification
VECTRON

TFS374B

Filter specification
VECTRON

TFS374D

Filter specification
VECTRON

TFS378

Filter Specification
VECTRON

TFS380A

Filter specification
VECTRON

TFS380B

TELEFILTER
ETC

TFS380C

VI TELEFILTER Filter specification
ETC

TFS380E

Filter Specification
VECTRON