Filter specification
TFS 360K
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
22
0
°C
dBm
118 Ω || -10.1 pF
150 Ω || - 9.9 pF
Output:
Characteristics
Remark:
The reference level for the relative attenuation a of the TFS 360K is the minimum of the pass band attenuation a
. The minimum of the pass band
min
rel
attenuation a
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 1 dB
min
e c
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 360 MHz without any tolerance. The given values for both the
relative attenuation a and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency f is shifted due to the
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .
e
N
rel
c
f
c
D a t a
typ. value
tolerance / limit
a
6.5
dB
max.
10,0
dB
Insertion loss
(reference level)
e
fN
360
± 15
MHz
MHz
Nominal frequency
Pass band
fN
PB
p-p
p-p
36,7
0,3
dB
dB
dB
max.
1
dB
Amplitude ripple
Amplitude ripple **
Relative attenuation
0,3
a
rel
MHz
fN
-
15
MHz ... fN
+
15
0,3
dB
max.
1
dB
fN
fN
fN
fN
-
-
+
+
100
75
35
MHz ... fN
MHz ... fN
MHz ... fN
MHz ... fN
-
-
+
+
75
35
75
MHz
MHz
MHz
MHz
55
34
35
50
dB
dB
dB
dB
min.
min.
min.
min.
40
25
25
40
dB
dB
dB
dB
75
100
p-p
14
2
ns
ns
max.
max.
min.
50
30
2
ns
ns
Group delay ripple in PB
Group delay variation **
VSWR **
p-p
1,5
max.
20
dBm
Input power level ***
OTR
-40 °C ... + 85 °C
Operating temperature range
Storage temperature range
-45 °C ... + 85 °C
-
TC *****
f
-90
ppm/K
Temperature coefficient of frequency
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) Applies over any 10MHz in PB
***) This power level is allowed for short term operation (10% of life time) only, the max. input power for continuous operation is 10 dBm.
****) ∆f (Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
c
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 360k.doc
Version 1.2
05.09.2005
VI TELEFILTER
Filter specification
TFS 360K
2/5
Filter characteristic
0
0
-0.4
-0.8
-1.2
-1.6
-2
0.534
0.498
0.462
0.426
0.39
-6
-12
-18
-24
-30
-36
-42
-48
-54
-60
0.354
0.318
0.282
0.246
0.21
-2.4
-2.8
-3.2
-3.6
-4
0.174
383
260
280
300
320
340
360
380
400
420
440
460
337
341.6
346.2
350.8
355.4
360
364.6
369.2
373.8
378.4
frequency in MHz
frequency in MHz
Construction and pin connection
1
2
3
4
5
6
7
8
Input
Input RF Return
Ground
Ground
Output
Output RF Return
Ground
Ground
(All dimensions in mm)
7
5
360K
● T37
1
3
3
Date code
1
Date code: Year + week
T
2005
2006
2007
U
V
...
7
5
1,1
2,54
50 Ohm Test circuit
L1
L3
1
2
5
6
SAW
L2
L4
3, 4, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 360k.doc
Version 1.2
05.09.2005
VI TELEFILTER
Filter specification
TFS 360K
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
P2
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
PIN Marker
t
Do
Po
Do
E
F
G(min)
P2
P1
D1(min)
Ao
Bo
:
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
5,50 ± 0,05
0,75
2,00 ± 0,05
8,00 ± 0,1
1,50
Ko
Typ
D1
Date Code
Ao
5,30 ± 0,1
5,30 ± 0,1
9,5 ± 0,1
Ct
W
2
Reel (all dimensions in mm)
A
:330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
C
: 50
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 360k.doc
Version 1.2
05.09.2005
VI TELEFILTER
Filter specification
TFS 360K
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 360k.doc
Version 1.2
05.09.2005
VI TELEFILTER
Filter specification
TFS 360K
5/5
History
Version
Reason of Changes
Name
Date
1.0
1.1
- generated specification according to customer requirement
Chilla
Chilla
02.02.2005
13.05.2005
- changed insertion loss
- changed max. amplitude ripple over any 10MHz to typical value
1.1
- created filter specification
- added terminating impedance
- added typical values
Chilla
05.09.2005
- added filter characteristic
- changed date code
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明