TFS360F1 [VECTRON]

Filter Specification; 过滤器规格
TFS360F1
型号: TFS360F1
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器
文件: 总5页 (文件大小:43K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
tfs360F1.doc  
version 1.4  
18.04.2001  
VI TELEFILTER  
Filter Specification  
TFS 360F1  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances  
for input:  
23 °C  
dBm  
0
580 Ohm // -0.85 pF  
580 Ohm // -0.85 pF  
91 nH  
for output:  
Coupling coil:  
Characteristics  
Remark:  
Reference level for the relative attenuation a of the TFS360F1 is the minimum of the pass band attenuation a  
. The minimum of the pass band  
rel  
min  
attenuation a  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the  
min  
e c  
1.5 dB filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed on 360 MHz without tolerance. The given values for  
the relative attenuation a and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency f is shifted  
due to the temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .  
e
N
rel  
c
f
c
D a t a  
typ. value  
tolerance/limit  
Insertion loss  
(Reference level)  
a
= a  
min  
3,3  
dB  
max.  
5,0  
dB  
e
Nominal frequency  
Centre frequency  
f
f
-
360,00 MHz  
N
360,03 MHz  
c
Pass band ripple f ± 67,7kHz  
BW  
-
max.  
1,5  
dB  
N
Relative attenuation  
a
rel  
f
f
f
f
f
f
f
f
f
±
±
-
0,4 MHz…f  
0,6 MHz…f  
0,8 MHz…f  
3,0 MHz…f  
MHz…f  
MHz…f - 115  
0,8 MHz…f  
1,6 MHz…f  
±
±
-
-
-
0,6 MHz  
0,8 MHz  
3,0 MHz  
36...53  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
29  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
53  
57...62  
60...65  
53...65  
65...75  
54  
42  
50  
52  
49  
52  
50  
45  
52  
-
57  
77  
MHz  
MHz  
MHz  
- 57  
- 77  
+
+
+
+
+
1,6 MHz *)  
3,0 MHz  
56  
58...70  
3,0 MHz…f + 115  
MHz  
N
Group delay ripple  
67,76 kHz  
GD  
f
±
0.5  
-
µs  
max.  
max.  
2,0  
µs  
N
Input power level  
5
dBm  
Operating temperature range  
Storage temperature range  
- 35 °C ... + 95 °C  
- 35 °C … + 95 °C  
Temperature coefficient of frequency TC  
- 0.036 ppm/K²  
+ 20 °C  
Frequency inversion temperature  
*) One distortion with a 3 dB bandwidth of less than 60 kHz and a relative attenuation of more than 46 dB is allowed.  
Generated:  
Checked / approved:  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs360F1.doc  
version 1.4  
18.04.2001  
VI TELEFILTER  
Filter Specification  
TFS 360F1  
2/5  
Construction, pin configuration and 50 - matching network  
(All dimensions in mm)  
5
7
1,78  
360 F  
N16  
1
3
Da te c ode  
2,54  
1,1 Ma x.  
Date code:  
L
M
N
...  
Year + week  
Pin 1 Sym. Output  
Pin 2 Sym. Output  
Pin 3 External Coil  
Pin 4 Package Ground  
Pin 5 Sym. Input  
Pin 6 Sym. Input  
Pin 7 Ground  
1999  
2000  
2001  
Pin 8 Package ground  
50 Ohm Test circuit 1  
L1  
L3  
LB-IN  
LB-OUT  
6
1
SAW  
C1  
C2  
2
5
L2  
L4  
3
L5  
4, 7, 8  
50 Ohm Test circuit 2  
C1  
C3  
LB-IN  
LB-OUT  
6
5
1
L1  
SAW  
L2  
2
C4  
C2  
3
L3  
4, 7, 8  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs360F1.doc  
version 1.4  
18.04.2001  
VI TELEFILTER  
Filter Specification  
TFS 360F1  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Damp heat:  
(cycle)  
25 °C to 55°C / 95% r.H. / 10 cycles  
DIN IEC 68 - 2 – 30 Db  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
Do  
E
:
:
:
:
:
12  
4
± 0,3  
± 0,1  
Po  
P 2  
D
o
1,5 + 0,1  
1,75 ± 0,1  
E
F
Ao  
F
5,5 ± 0,05  
0,75  
G (min) :  
D1  
CT  
W
Bo  
P2  
P1  
:
2
± 0,05  
± 0,1  
:
8
G
D1(min) :  
1,5  
Ao  
Bo  
CT  
:
:
4,3 ± 0,1  
4,3 ± 0,1  
9,5 ± 0,1  
P1  
COVER TAPE  
:
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
:
12,4 + 0,2  
W2 (max) :  
18,4  
N (min)  
C
50  
C
A
:
13  
± 0,2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs360F1.doc  
version 1.4  
18.04.2001  
VI TELEFILTER  
Filter Specification  
TFS 360F1  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs360F1.doc  
version 1.4  
18.04.2001  
VI TELEFILTER  
Filter Specification  
TFS 360F1  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of specification  
Name  
Date  
Dr. Wall  
Dr. Wall  
Dr. Wall  
22.08.2000  
28.08.2000  
18.10.2000  
1.1  
- Add values for termination impedance and coupling coil  
1.2  
- Pin numbers in package drawing added  
- Tape and reel information added  
- Typical filter data added  
1.3  
- Change values for termination impedances from 520 ohm // -0.85 pF  
to 580 Ohm // -0.85 pF.  
Dr. Wall  
Dr. Wall  
27.11.2000  
18.04.2001  
TFS360F1  
1.4  
- Increase operating temperature range.  
- Change storage temperature range.  
- Change value for typical centre frequency.  
- Change filter name to TFS360F1  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS360F_00

Filter Specification
VECTRON

TFS360K

Filter specification
VECTRON

TFS365B

Filter specification
VECTRON

TFS368

Filter specification
VECTRON

TFS36A

Filter Specification
VECTRON

TFS36B

Filter Specification
VECTRON

TFS36C

Filter Specification
VECTRON

TFS36D

Filter Specification
VECTRON

TFS36F

Filter Specification
VECTRON

TFS37

Filter Specification
VECTRON

TFS370

Filter Specification
VECTRON

TFS374A

Filter specification
VECTRON