REDIN120-48 [RECOM]
DC OK Indicator LED with Relay Contacts;![REDIN120-48](http://pdffile.icpdf.com/pdf2/p00331/img/icpdf/REDIN120_2038145_icpdf.jpg)
型号: | REDIN120-48 |
厂家: | ![]() |
描述: | DC OK Indicator LED with Relay Contacts |
文件: | 总8页 (文件大小:2646K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
• Universal AC Input (85-264VAC)
• Protections: SCP, OVP, OLP, OTP
• DC OK Indicator LED with Relay Contacts
• 150% (180W) peak load capacity
• Built-in active PFC,PF>0,95
Features
AC/DC Converter
DIN Rail
Series
• High effciency up to 92.5%
REDIN120
120 Watt
DIN-Rail
Description
These DIN-rail mounted power supplies have a robust case, 4mm screw terminal connectors and use
high reliability components to give a long, trouble-free life. The REDIN120 can be end mounted to
save rail space or side mounted for use in low-profile cabinets. The units can deliver up to 150%
start-up power and allow n+1 parallel operation to increase the continuous output current or for supply
redundancy. Relay contacts simplify DC OK monitoring. The REDIN120 series is designed for
demanding commercial and industrial applications with UL508, UL60950, IEC60950 CB report and
CE (LVD + EMC + RoHS) certifications. They come with a full 5-year warranty.
Power
Supply
Selection Guide
Part
Number
nom. Input
Voltage Range
Output
Voltage
Output
Adjustability
Rated
Current
Efficiency
typ.
230VAC full load
[%]
[VAC]
[VDC]
12
24
[VDC]
12-14
24-28
48-56
[A]
8.33
5
REDIN120-12
REDIN120-24
REDIN120-48
100-240
100-240
100-240
89.5
91.5
92.5
48
2.5
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
85VAC
264VAC
Absolute Maximum Input
Voltage
300VAC
375VDC
max. 3s
115VAC, full load
230VAC, full load
12Vout
1.5A
0.65A
Input Current
18V
35V
65V
40A
60A
Return Voltage Immunity
24Vout
48Vout
E224736
115VAC, cold start
230VAC, cold start
Inrush Current
115VAC
230VAC
1.5W
1.2W
3W
3W
No Load Power Consumption
UL60950-1 Certified
UL508 Certified
IEC/EN60950-1 Certified
Input Frequency Range
Output Voltage Trimming
47Hz
63Hz
+16.67%
115VAC
230VAC
0.99
0.95
Power Factor
Start-up time
Hold-up time
115VAC, full load
230VAC, full load
500ms
250ms
115VAC, full load
230VAC, full load
20ms
20ms
40ms
40ms
0 - 70°C
-25°C
100mVp-p
200mVp-p
12Vout
24Vout
Ripple and Noise(1)
0 - 70°C
-25°C
120mVp-p
240mVp-p
-25°C - 70°C 48Vout
240mVp-p
Notes:
Note1: Measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated
with a 0.1µF & 10µF parallel capacitor.
continued on next page
www.recom-power.com
REV.: 0/2016
PDR-1
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
REDIN120-12
Efficiency vs. Load
Power Dissipation vs Load
25
100
90
80
70
60
50
40
30
20
10
0
20
15
10
5
115VAC
230VAC
264VAC
115VAC
230VAC
0
0
0
2
4
6
8
2
4
6
8
Load Current [A]
Load Current [A]
Power Factor vs Load over Vin
Input Current vs Load
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1.4
1.2
1
0.8
0.6
0.4
0.2
0
115VAC
230VAC
Iin 115VAC [A]
Iin 230VAC [A]
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
Load Current [A]
Load Current [A]
REDIN120-24
Efficiency vs. Load
Power Dissipation vs Load
100
90
80
70
60
50
40
30
20
10
25
20
15
10
5
115VAC
230VAC
264VAC
115VAC
230VAC
0
0
0
0
1
2
3
4
5
1
3
4
5
2
Load Current [A]
Load Current [A]
Power Factor vs Load over Vin
Input Current vs Load
1.4
1.2
1
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0.8
0.6
0.4
0.2
115VAC
230VAC
Iin 115VAC [A]
Iin 230VAC [A]
0
0
0
1
2
3
4
5
1
2
3
4
5
Load Current [A]
continued on next page
REV.: 0/2016
Load Current [A]
PDR-2
www.recom-power.com
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
REDIN120-48
Efficiency vs. Load
Power Dissipation vs Load
25
100
90
80
70
60
50
40
30
20
10
0
20
15
10
5
115VAC
230VAC
264VAC
115VAC
230VAC
0
0
0.5
1
1.5
2
2.5
0
0.5
1
1.5
2
2.5
Load Current [A]
Load Current [A]
Input Current vs Load
Power Factor vs Load over Vin
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1.4
1.2
1
0.8
0.6
0.4
0.2
0
115VAC
230VAC
Iin 115VAC [A]
Iin 230VAC [A]
0
0.5
1
1.5
2
2.5
0
0.5
1
1.5
2
2.5
Load Current [A]
Load Current [A]
REGULATION
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
0.25% typ. ꢀ 1% max.
0.1% typ. ꢀ 0.5% max.
0.25% typ. ꢀ 1.0% max.
1% typ. ꢀ 5% max.
0% to 100% load
Transient Response
100Hz & 1kHz, 50% duty
PROTECTION
Parameter
Input Fuse
Condition
internal
Value
T5A, slow blow type
Short Circuit Protection (SCP)
Hiccup Mode (current limit)
12Vout
24Vout
48Vout
15-18VDC, Hiccup Mode
29-33VDC, Hiccup Mode
58-65VDC, Hiccup Mode
Over Voltage Protection (OVP)
Over Voltage Category (OVC)
Over Load Protection (OLP)
OVC II
Constant power (current limit)
100 5°C, detect on Heat-sink of power transistorꢁ shut down
OꢀP, auto recovery after temperature goes down
Vout up to 90% of rated Vout
Over Temperature Protection (OTP)
ON (green)
OFF (red)
Power OK LED
Vout down to 80% of rated Vout
Relay Contact Rating
Max. 30Vꢀ1A or 60Vꢀ0.3 or 30VACꢀ0.3A Resitive Load
continued on next page
REV.: 0/2016
www.recom-power.com
PDR-3
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
IꢀP to OꢀP
IꢀP to PE
OꢀP to PE
3.0kVAC ꢀ 1minute
2.5kVAC ꢀ 1minute
0.5kVAC ꢀ 1minute
10MW min.
Isolation Voltage
Isolation Resistance
Leakage Current
IꢀP to OꢀP
IꢀP to PE, 240VAC 50Hz
0.1mA typ. ꢀ 0.25mA max.
1.0mA max.
Overload Capability
y
Time (x) [s]
Pout (y) [%]
180
1
4
150
7
140
100
45
120
0
x
60
Time [s]
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range
Temperature Coefficient
Operating Altitude
Operating Humidity
IP Rating
with derating
-25°C to +70°C
0.03%ꢀ°C
3000m
non-condensing
20% - 90% RH
IP20
Pollution Degree (PD)
Shock
PD2
10-500Hz 2G, 60min.
Vibration
10G ꢀ11ms, along x,y and z axis
300 x 10³ hours
MTBF
MIL-HDBK-217F, full load, 25°C
Derating Graph
100
80
60
40
20
0
Pout 115VAC cont.
Pout 230VAC cont.
-25 -20 -10
0
10
20
30
40
50
60
70
80
Ambient Temperature [°C]
continued on next page
REV.: 0/2016
PDR-4
www.recom-power.com
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E224736
UL508, 17th Edition, 2013
CSA C22.2 No. 107.1-01, 3rd Edition, 2011
IEC60950-1, 2nd Edition 2005, +AM1:2009 + AM2:2013
EN60950-1:2006, + A11:2009 + A1:2010 + A12:2011
+ A2:2013
Industrial Control Equipment
E470721
SA1508106S 001 +
SA1508106S 002
Information Technology Equipment - General Requirments for Safety
EMC Compliance
Report / Condition
Standard / Criterion
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
EN55022, Class B, 2010
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
EN55024, Class B, 2010
Limitations on the amount of electromagnetic intererence allowed from
digital and electronic devices
47 CFR FCC Part 15, Subpart B: 2014
Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.4: 2014
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Air 8kV, Contact 4kV
EN61000-4-2, Criteria B, 2009
EN61000-4-3, Criteria A, 2006
EN61000-4-4, Criteria B, 2012
EN61000-4-5, Criteria B, 2014
EN61000-4-6, Criteria A, 2014
EN61000-4-8, Criteria A, 2010
3Vꢀm
AC Power Port: L+N+PE 1kV
AC Power Port L-N 1kV, L-PE + N-PE 2kV
AC Power Port 3V
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
50Hz, 1Aꢀm
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
EN61000-4-11, Criteria B, 2004
EN61000-4-11, Criteria C, 2004
EN61000-4-11, Criteria C, 2004
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
Voltage Fluctuations & Flicker
EN61000-3-2, Criteria A, 2014
EN61000-3-3, Clause 5: 2013
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case
Cover
Aluminium
Nickel plated steel
Material
Package Dimension (LxWxH)
Package Weight
without mounting clip
114.5 x 33.0 x 124.4mm
590g typ.
continued on next page
www.recom-power.com
REV.: 0/2016
PDR-5
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
Dimension Drawing (mm)
DC OK -V +V
10.3
Vadj.
DC OK LED
Parallel Use
Single Use
55.0
28.4
N
L
PE
33.0
114.5
124.0
43.0
41.5
Terminals and Wiring
Screw Connector
2.5-6mm2
Type
Solid Wire
Stranded Wire
2.5-4mm2
American Wire Gauge (AWG)
Wire Stripping Length
AWG10-16
8mm
Screwdriver (slotted ꢀ cross)
3.5mm
Recommended tightening torque 0.5Nm-0.8Nm
Tolerance: X.X 0.5mm
X.XX 0.25mm
PDR-6
REV.: 0/2016
www.recom-power.com
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
INSTALLATION and APPLICATION
Mounting Instruction
Mounting
Releasing
1
Vadj.
DC OK LED
Parallel Use
Single Use
2
2
„Click“
1
Mounting Multiple Power Supplies
Vadj.
Vadj.
Vadj.
DC OK LED
DC OK LED
DC OK LED
Parallel Use
Single Use
Parallel Use
Single Use
Parallel Use
Single Use
15mm
15mm
leave 15mm gap between supplies
15mm Minimum Abstand
www.recom-power.com
REV.: 0/2016
PDR-7
REDIN120
AC/DC Converter
Specifications (measured @ t = 25°C, rated Vin, rated load and after warm up)
a
Series
Parallel Operation
L1 L2 L3 N PE
L N PE
+
-
~
~
~
+
+V
-V
DC
OK
~
~
~
-
+
+
+V
-V
DC
OK
Load
-
-
+
-
+V
-V
DC
OK
DC OK
Single Operation:
1) Make sure that the front panel switch is set to “single Use.”
2) The output voltage can be increased by trim pot to compensate any cable losses.
Parallel Operation:
1) Make sure that the front panel switch is set to “single Use” on each power supply.
2) Adjust each power supply to the exact same output voltage with same load and cooling conditions.
3) Set the front panel switches to “Parallel Use.” Use the same wire length for each power supply (star connection) and energize all units at the
same time to avoid triggering overload protection.
Derate the maximum output power to 90% of nominal ratings.
For operation with more than three power supplies in parallel or series operation, please contact RECOM technical support for advice.
Application Circuit
T5A
+V
-V
L
Input
Filter
Output
Filter
Power Stage
Protection
N
E
DC
OK
Relay
OTP
Shut-
Down
LED
Vadj.
OVP
Shut-
Down
Output
Voltage
Regulation
OCP
Limit
Single /
Parallel
PACKAGKING INFORMATION
Parameter
Type
Value
140.0 x 50.0 x 142.0mm
1pcs.
Packaging Dimension (LxWxH)
Packaging Quantity
cardboard box
cardboard box
Storage Temperature Range
Storage Humidity
-40°C to +85°C
5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PDR-8
REV.: 0/2016
www.recom-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明