REDIN240-48 [RECOM]
Universal AC Input;![REDIN240-48](http://pdffile.icpdf.com/pdf2/p00335/img/icpdf/REDIN240-48_2061122_icpdf.jpg)
型号: | REDIN240-48 |
厂家: | ![]() |
描述: | Universal AC Input |
文件: | 总8页 (文件大小:609K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
• Universal AC Input (85-264VAC)
• Protections: SCP, OVP, OLP, OTP
• DC OK Indicator LED with Relay Contacts
• 150% (360W) peak load capacity
• Built-in active PFC,PF>0.95
Features
AC/DC Converter
DIN Rail
Series
• High effciency up to 94%
REDIN240
240 Watt
DIN-Rail
Description
These DIN-rail mounted power supplies have a robust case, 4mm screw terminal connectors and use
high reliability components to give a long, trouble-free life. The REDIN240 can be end mounted to save
rail space or side mounted for use in low-profile cabinets. The units can deliver up to 150% start-up
power and allow n+1 parallel operation to increase the continuous output current or for supply redun-
dancy. Relay contacts simplify DC OK monitoring. The REDIN240 series is designed for demanding
commercial and industrial applications with UL508, UL60950, IEC60950 CB report and CE (LVD + EMC
+ RoHS) certifications. They come with a full 5-year warranty.
Power
Supply
Selection Guide
Part
nom. Input
Voltage Range
[VAC]
Output
Voltage
[VDC]
Output
Adjustability
[VDC]
Rated
Current
[A]
Efficiency
typ.
Number
[%]
REDIN240-24
REDIN240-48
100-240
100-240
24
48
24-28
48-56
10
5
94.35
93.7
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
85VAC
264VAC
Absolute Maximum Input
Voltage
300VAC
375VDC
max. 3 seconds
full load, 115VAC
full load, 230VAC
2.28A
1.13A
3.0A
1.5A
Input Current
Inrush Current
cold start at 25°C, 115VAC
cold start at 25°C, 230VAC
15A
32A
20A
40A
85-264VAC
230VAC
2.2W
1.8W
4W
3W
No Load Power Consumption
Input Frequency Rang e
Output Trim
47Hz
63Hz
24Vout
48Vout
24V
48V
28V
56V
E224736
115VAC
230VAC
0.99
0.95
Power Factor
Start-up time
115VAC
24Vout
1.48s
1.27s
230VAC
3s
UL60950-1 Certified
UL508 Certified
115VAC
48Vout
1.45s
1.25s
230VAC
IEC/EN60950-1 Certified
24Vout
230VAC
48Vout
20ms
20ms
26.28ms
24.74ms
16.62ms
26.27ms
Hold-up time
Rise time
24Vout
230VAC
48Vout
100ms
0 - 70°C
24Vout
-25°C
240mVp-p
480mVp-p
Ripple & Noise(1)
-25 - 70°C 48Vout
480mVp-p
Notes:
Note1: Measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated
with a 0.1µF & 10µF parallel capacitor.
continued on next page
www.recom-power.com
REV.: 1/2016
PDR-1
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
REDIN240-24
Efficiency vs. Load
Power Dissipation vs Load
25
100
90
80
70
60
50
40
30
20
10
0
20
15
10
5
115VAC
230VAC
264VAC
115VAC
230VAC
0
0
2
4
6
8
10
12
Load Current [A]
Input Current vs Load
Power Factor vs Load over Vin
1.2
1.0
0.8
0.6
0.4
0.2
0
2.5
2
1.5
1
0.5
0
115VAC
230VAC
Iin 115VAC [A]
Iin 230VAC [A]
0
10
20
30
40
50
60
70
80
90 100
0
2
4
6
8
10
12
Load Current [%]
Load Current [A]
REDIN240-48
Efficiency vs. Load
Power Dissipation vs Load
100
90
80
70
60
50
40
30
20
10
25
20
15
10
5
115VAC
230VAC
264VAC
115VAC
230VAC
0
0
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Load Current [A]
Load Current [A]
Input Current vs Load
Power Factor vs Load over Vin
2.5
2
1.2
1.0
0.8
0.6
0.4
0.2
0
1.5
1
0.5
Iin 115VAC [A]
Iin 230VAC [A]
115VAC
230VAC
0
0
10
20
30
40
50
60
70
80
90 100
0
1
2
3
4
5
6
Load Current [%]
Load Current [A]
PDR-2
REV.: 1/2016
www.recom-power.com
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
REGULATION
Parameter
Condition
Value
24Vout
48Vout
0.4% typ. / 3% max.
0.3% typ. / 3% max.
Output Accuracy
24Vout
48Vout
0.03% typ. / 0.5% max.
0.04% typ. / 0.5% max.
Line Regulation
Load Regulation
0% to 100% load
0.3% typ. / 1.0% max.
1% typ. / 5% max.
Transient Response
100Hz & 1kHz, 50% duty, 25% load step change
PROTECTION
Parameter
Condition
Value
T5A, slow blow type
Input Fuse
Short Circuit Protection (SCP)
continuous, auto recovery
24Vout
48Vout
29-33VDC, constant voltage auto recovery
58-63VDC, constant voltage auto recovery
Over Voltage Protection (OVP)
Over Voltage Category (OVC)
Over Load Protection (OLP)
OVC II
Limit the current by constant power circuit
105 5°C , detect on Heat-sink of power transistor; shut down
O/P , auto recovery after temperature goes down
3.0KVAC / 1minute
Over Temperature Protection (OTP)
I/P to O/P
I/P to PE
O/P to PE
Isolation Voltage
2.5KVAC / 1minute
0.5kVAC / 1minute
Isolation Resistance
Leakage Current
10MW min.
I/P to O/P
I/P to PE
0.25mA max.
3.5mA max.
ON
OFF
Vout up to 90% of rated Vout
Vout down to 80% of rated Vout
Power OK LED
Relay Contact Rating
Max. 30V/1A or 60V/0.3 or 30VAC/0.3A Resitive Load
Overload Capability
Time (x) [s]
Pout (y) [%]
150
3
4
140
y
7
130
45
120
100
0
x
60
Time [s]
www.recom-power.com
REV:: 1/2016
PDR-3
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
ENVIRONMENTAL
Parameter
Condition
with derating
Value
-25°C to +70°C
0.3%/°C
Operating Temperature Range
Temperature Coefficient
Operating Altitude
Operating Humidity
IP Rating
3000m
non-condensing
20% - 90% RH
IP X0
Pollution Degree (PD)
Shock
PD 2
10-500Hz 2G, 60min.
10G /11ms, along x,y and z axis
300 x 10³ hours
Vibration
MTBF
MIL-HDBK-217F, full load, 25°C
Thermal Dertating
100
80
60
40
20
0
Pout 115VAC cont.
Pout 230VAC cont.
-25 -20 -10
0
10
20
30
40
50
60
70
80
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E224736
UL508, 17th Edition, 2013
CSA C22.2 No. 107.1-01, 3rd Edition, 2011
Industrial Control Equipment
E470721
IEC60950-1, 2nd Edition 2005, +AM1:2009 + AM2:2013
EN60950-1:2006, + A11:2009 + A1:2010 + A12:2011
+ A2:2013
NTEK-
2016NT02244417S
Information Technology Equipment - General Requirments for Safety
EMC Compliance
Report / Condition
Standard / Criterion
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
EN55022:2010 + AC:2011, Class B
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
EN55024:2010 + A1:2015
Limitations on the amount of electromagnetic intererence allowed from
digital and electronic devices
47 CFR FCC Part 15, Subpart B: 2016
ESD Electrostatic discharge immunity test
Air 8kV, Contact 4kV
3V/m
EN61000-4-2, Criteria B, 2009
EN61000-4-3, Criteria A, 2006
Radiated, radio-frequency, electromagnetic field immunity test
continued on next page
PDR-4
REV.: 1/2016
www.recom-power.com
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
Fast Transient and Burst Immunity
AC Power Port: L+N+PE 1kV
EN61000-4-4, Criteria B, 2012
EN61000-4-5, Criteria B, 2014
EN61000-4-6, Criteria A, 2014
EN61000-4-8, Criteria A, 2010
Surge Immunity
AC Power Port L-N 1kV, L-PE + N-PE 2kV
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
AC Power Port 3V
50Hz, 1A/m
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
EN61000-4-11, Criteria B, 2004
EN61000-4-11, Criteria C, 2004
EN61000-4-11, Criteria C, 2004
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
Voltage Fluctuations & Flicker
EN61000-3-2, Criteria A, 2014
EN61000-3-3, Clause 5, 2013
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case
Cover
Aluminium
Nickel plated steel
Material
Package Dimension (LxWxH)
Package Weight
without mounting clip
114.26 x 46.0 x 124.4mm
810g typ.
Dimension Drawing (mm)
12.5
38.0
DC OK +V +V -V -V
10.4
Vadj.
DC OK LED
Parallel Use
Single Use
6.85
55.0
28.3
PE
N
L
19.1
46.0
114.26
123.77
continued on next page
REV.: 1/2016
www.recom-power.com
PDR-5
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
34.0
44.0
Terminals and Wiring
Screw Connector
1-6mm2
Type
Solid Wire
Stranded Wire
1-4mm2
American Wire Gauge
Wire Stripping Length
Screwdriver (slotted / cross)
AWG17-10
8mm
3.5mm
Recommended tightening torque 0.5Nm-0.8Nm
Tolerance: X.X 0.5mm
X.XX 0.25mm
24.75
1.75
INSTALLATION
Mounting Instruction
Mounting
Releasing
1
DC OK +V +V -V -V
Vadj.
DC OK LED
Parallel Use
Single Use
N
PE
L
2
2
„Click“
1
PDR-6
REV.: 1/2016
www.recom-power.com
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
INSTALLATION
Mounting Multiple Power Supplies
DC OK +V +V -V -V
DC OK +V +V -V -V
DC OK +V +V -V -V
Vadj.
Vadj.
Vadj.
DC OK LED
DC OK LED
DC OK LED
Parallel Use
Single Use
Parallel Use
Single Use
Parallel Use
Single Use
N
L
PE
N
L
PE
N
L
PE
15mm
15mm
leave 15mm gap between supplies
Parallel Operation & Phase Redundancy
L1 L2 L3 N PE
L N PE
+
-
~
~
~
+
+V
-V
DC
OK
~
~
~
-
+
+
-
+V
-V
DC
OK
Load
-
+
-
+V
-V
DC
OK
DC OK
Single Operation:
1) Make sure that the front panel switch is set to “single Use.”
2) The output voltage can be increased by trim pot to compensate any cable losses.
Parallel Operation:
1) Make sure that the front panel switch is set to “single Use” on each power supply.
2) Adjust each power supply to the exact same output voltage with same load and cooling conditions.
3) Set the front panel switches to “Parallel Use.” Use the same wire length for each power supply (star connection) and energize all units at the
same time to avoid triggering overload protection.
Derate the maximum output power to 90% of nominal ratings.
For operation with more than three power supplies in parallel or series operation, please contact RECOM technical support for advice.
www.recom-power.com
REV.: 1/2016
PDR-7
REDIN240
AC/DC Converter
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)
Series
Application Circuit
T5A
+V
-V
L
Input
Filter
Output
Filter
Power Stage
N
E
DC
OK
Relay
OTP
Shut-
Down
Protection
LED
Vadj.
OVP
Shut-
Down
Output
Voltage
Regulation
OCP
Limit
Single /
Parallel
PACKAGKING INFORMATION
Parameter
Type
Value
140.0 x 63.0 x 142.0mm
1pcs
Packaging Dimension (LxWxH)
Packaging Quantity
cardboard box
cardboard box
Storage Temperature Range
Storage Humidity
-40°C to +85°C
5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PDR-8
REV.: 1/2016
www.recom-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明