• Universal AC Input (85-264VAC)
• Long 7 Year Warranty
• Protections: SCP, OVP, OCP, OTP
• 100% Full Load burn-in test
Features
AC/DC Converter
• DC OK Indicator LED with Relay Contacts
• cooling by free air convection, 5000m operation
• UL, CSA & CE certified with CB Report
REDIN45
45 Watt
DIN-Rail
Power
Supply
Description
This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life.The
power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay
contacts simplify DC OK monitoring and the units can deliver 60W start-up power. The REDIN series is
fully certified for industrial use and carries a 7-year warranty.
Selection Guide
Part
Number
Input
Output
Output
Rated
Efficiency
typ.
Max.
Capacitive Load
(µF)
Voltage Range Voltage Trimming Voltage Current
(VAC)
85-264
85-264
(VDC)
12
24
(VDC)
12-15
24-28
(A)
3.75
1.875
(%)
85
86
REDIN45-12
REDIN45-24
18800
4700
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
all operating conditions
85VAC
264VAC
300VAC
375VDC
max. Input Voltage
max. 1 second
Output Voltage Adjustment
(Factory Setting) (1)
12Vout
24Vout
12-15VDC (12V 5ꢀ)
24-28VDC (24V 5ꢀ)
full load, 115VAC
full load, 230VAC
1.35A
0.75A
Input Current
E224736
cold start at 25°C, 115VAC
cold start at 25°C, 230VAC
40A
60A
Inrush Current
standard (with Relay)
/NR option (no Relay)
<1000mW
<500mW
No Load Power Consumption
Start Up time
Rise time
cold start, 230VAC
cold start, 230VAC
500ms
20ms
1000ms
CB-Report
UL-60950-1 Certified
UL-508 Certified
IEC-60950-1 Certified
EN-60715 Compliant
EN-50022 Compliant
CSA C22.2 No. 60950-1-07 Certified
full load, 115VAC
full load, 230VAC
20ms
50ms
Hold-up time
Input Frequency Range
Operating Frequency Range
Efficiency
47Hz
63Hz
65kHz
see Selection Guide
12Vout
24Vout
60mVp-p
75mVp-p
Output Ripple and Noise(2)
Over Load
all operating conditions
140ꢀ for 5 seconds max.
Notes:
Note1: For more details refer to Vadj. Derating Graph
Note2: Ripple and Noise are measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated with 0.1µF &
47µF parallel capacitor.
continued on next page
Refer to Applications Notes
www.recom-power.com
REV.: 3/2016
PA-1
REDIN45
AC/DC Converter
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
Series
Efficiency vs. Load
REDIN45-12
REDIN45-24
90
90
80
70
60
50
80
70
60
50
40
40
30
20
10
0
85VAC
85VAC
30
20
10
0
115VAC
230VAC
264VAC
115VAC
230VAC
264VAC
3
3.75
1.5 1.875
0
1
2
0
0.5
1
Load (A)
Load (A)
Vadj. Derating
100
80
45W max.
Vadj.
12
(24)
15
(28)
Output Voltage (V)
REGULATION
Parameter
Condition
Value
Line Regulation
Load Regulation
Transient Response(3)
0.1 typ. / 1ꢀ max.
0.1 typ. / 1ꢀ max.
12Vout (step load change: 1.875A - 3.75A)
24Vout (step load change: 0.937A - 1.875A)
5ꢀ typ.
5ꢀ typ.
Dwell Time
Slew Rate
100Hz & 1kHz 50ꢀ duty
0.5A / µs
Notes:
Note3:
Transient Response + E-CAP loading 3300µF. Other specs with resistive load only.
PROTECTION
Parameter
Input Fuse
Condition
Value
T2.5A, slow blow type
Short Circuit Protection (SCP)
Hiccup
auto-recovery after fault condition
12Vout
24Vout
18VDC max., shut-down latch-off o/p voltage, re-power on to recover
35VDC max., shut-down latch-off o/p voltage, re-power on to recover
Over Voltage Protection (OVP)
Over Current Protection (OCP)
150ꢀ typ., auto-recovery after fault condition
Over Temperature Protection (OTP)
detect on inside ambient
105°C 5ꢀ, shut-down latch-off o/p voltage, re-power on to recover
I/P to O/P
I/P to FG
O/P to FG
3.75kVAC / 1 minute
1.88kVAC / 1 minute
0.5kVAC / 1 minute
100MW min.
Isolation Voltage
Isolation Resistance
Leakage Current
500VDC, 70ꢀ RH, I/P to O/P; I/P to FG; O/P to FG
240VAC
<1.0mA
Relay Contacts
LED/Relay
1A, 30VDC / 120VAC
ON if Vout = 11-16V (12V) / 22-30V (24V)
Power OK LED
PA-2
REV.: 3/2016
www.recom-power.com
REDIN45
AC/DC Converter
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
Series
ENVIRONMENTAL
Parameter
Condition
with derating
Value
-20°C to +70°C (see graph)
20ꢀ - 90ꢀRH
Operating Temperature Range
Operating Humidity
Vibration
non-condensing
10-500Hz 2G, 60min.
10G / 11ms, along X, Y and Z axis
5000m
Shock
3 times each axis
see derating graph
Altitude
MTBF (+25°C)
Design Lifetime (+40°C)
MIL-HDBK-217F, 115VAC, 60Hz, 75ꢀ load
200 x 10³ hours
87.6 x 10³ hours
Derating Graph
Vin ≤ 100VAC
Vin > 100VAC
100
90
100
24VDC
24VDC
12VDC
90
80
80
12VDC
70
70
60
50
40
60
50
40
30
20
10
0
30
20
10
0
-20
-10
10
30
50
70
-20
-10
10
30
50
70
Temperature (°C)
Temperature (°C)
Typical Characteristics
REDIN45-12
REDIN45-24
35°C
50°C
35°C
5000
4000
3000
5000
4000
3000
40°C
(45W)
(45W)
2000
2000
20
40
60
80
100
20
40
60
80
100
www.recom-power.com
REV.: 3/2016
PA-3
REDIN45
AC/DC Converter
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
UL General Safety
Report / File Number
Standard
UL-60950-1, 2nd Edition
UL-1310
E224736
CSA General Safety
C22.2 No. 60950-1-07, 2nd Edition
Industrial Control Equipment
General Use Power Supplies
UL-508
C22.2 No. 107.1
E470721
IEC/EN General Safety
E224736
E224736
IEC/EN-60950-1, 2nd Edition
GB 4943.1-2011
Chinese Safety Standard
EMC Compliance
Report / Condition
Standard / Criterion
EN-55022, Class B
EN-55024, Class B
FCC15, Class B
EMI Standard
Report: HA150146
ESD
8kV Contact & Air Discharge
10V/m, 80-3000MHz, 80ꢀ AM at 1kHz
Level 2
2kV / L-N, 4kV / L, N-FG
10Vrms, 0.15-80MHz, 80ꢀ AM at 1kHz
EN-61000-4-2, Criteria A
EN-61000-4-3, Criteria A
EN-61000-4-4, Criteria A
EN-61000-4-5, Criteria A
EN-61000-4-6, Criteria A
EN-61000-4-8, Criteria A
EN-61000-4-11, Criteria A
EN-61000-4-11, Criteria B
EN-61000-4-11, Criteria B
EN-61000-3-2
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Power frequency magnetic field immunity test
Noise Immunity
40ꢀ reduction, 200ms
70ꢀ reduction, 500ms
90ꢀ reduction, 5s
Harmonic Immunity
Voltage Flicker
not applicable input below 75W
EN-61000-3-3
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Case Material
Type
Value
UL94V-0 plastic
45.1 x 92.0 x 101.2mm
332g
Paclage Dimension (WxHxD)
Package Weight
Dimension Drawing (mm)
1±1.ꢀ
+V -V
DC OK
DC OK
TRIM
Front Side
FG N
L
45.1
continued on next page
REV.: 3/2016
PA-4
www.recom-power.com
REDIN45
AC/DC Converter
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
Series
Dimension Drawing (mm)
DIN-RAIL mounting bracket
(75mm) included
7.5±±.ꢀ
75±±.ꢁ
6.ꢁ±±.ꢀ
ꢁ5±±.1
ꢀ5.±
1±±.±5
18±±.ꢀ
ꢀ5.±
INSTALLATION
END MOUNTING
SIDE MOUNTING
+V -V
DC OK
Front Side
FG N
L
End Latch
Release
Side Latch
Release
Tolerance: ±±.5ꢂꢂ
Mounting Instruction
Releasing
Mounting
1
Front Side
2
FG
N L
2
„Click“
1
continued on next page
REV.: 3/2016
www.recom-power.com
PA-5
REDIN45
AC/DC Converter
Specifications (measured at T = 25°C, 230VAC, full load and after warm up)
A
Series
Mounting Multiple Power Supplies
FG N
L
FG N
L
FG N L
0mm
0mm
no spacers between
supplies required
Functional Diagram
T2.5A
+V
L
Input
Filter
Output
Filter
Power Stage
Protection
N
-V
E
DC
OK
Relay
OTP
Shut-
Down
LED
OVP
Shut-
Down
Outoput
Voltage
Regulation
OCP
Limit
Vadj.
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
Packaging Quantity
Cardboard Box
310 x 285 x 252mm
30pcs
Storage Temperature Range
Storage Humidity
-30°C to +85°C
10ꢀ - 90ꢀ RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written