• Universal AC Input (85-264VAC)  
• Protections: SCP, OVP, OLP, OTP  
• DC OK Indicator LED with Relay Contacts  
• 150% (360W) peak load capacity  
• Built-in active PFC,PF>0.95  
Features  
AC/DC Converter  
DIN Rail  
Series  
• High effciency up to 94%  
REDIN240  
240 Watt  
DIN-Rail  
Description  
These DIN-rail mounted power supplies have a robust case, 4mm screw terminal connectors and use  
high reliability components to give a long, trouble-free life. The REDIN240 can be end mounted to save  
rail space or side mounted for use in low-profile cabinets. The units can deliver up to 150% start-up  
power and allow n+1 parallel operation to increase the continuous output current or for supply redun-  
dancy. Relay contacts simplify DC OK monitoring. The REDIN240 series is designed for demanding  
commercial and industrial applications with UL508, UL60950, IEC60950 CB report and CE (LVD + EMC  
+ RoHS) certifications. They come with a full 5-year warranty.  
Power  
Supply  
Selection Guide  
Part  
nom. Input  
Voltage Range  
[VAC]  
Output  
Voltage  
[VDC]  
Output  
Adjustability  
[VDC]  
Rated  
Current  
[A]  
Efficiency  
typ.  
Number  
[%]  
REDIN240-24  
REDIN240-48  
100-240  
100-240  
24  
48  
24-28  
48-56  
10  
5
94.35  
93.7  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Input Voltage Range  
85VAC  
264VAC  
Absolute Maximum Input  
Voltage  
300VAC  
375VDC  
max. 3 seconds  
full load, 115VAC  
full load, 230VAC  
2.28A  
1.13A  
3.0A  
1.5A  
Input Current  
Inrush Current  
cold start at 25°C, 115VAC  
cold start at 25°C, 230VAC  
15A  
32A  
20A  
40A  
85-264VAC  
230VAC  
2.2W  
1.8W  
4W  
3W  
No Load Power Consumption  
Input Frequency Rang e  
Output Trim  
47Hz  
63Hz  
24Vout  
48Vout  
24V  
48V  
28V  
56V  
E224736  
115VAC  
230VAC  
0.99  
0.95  
Power Factor  
Start-up time  
115VAC  
24Vout  
1.48s  
1.27s  
230VAC  
3s  
UL60950-1 Certified  
UL508 Certified  
115VAC  
48Vout  
1.45s  
1.25s  
230VAC  
IEC/EN60950-1 Certified  
24Vout  
230VAC  
48Vout  
20ms  
20ms  
26.28ms  
24.74ms  
16.62ms  
26.27ms  
Hold-up time  
Rise time  
24Vout  
230VAC  
48Vout  
100ms  
0 - 70°C  
24Vout  
-25°C  
240mVp-p  
480mVp-p  
Ripple & Noise(1)  
-25 - 70°C 48Vout  
480mVp-p  
Notes:  
Note1: Measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated  
with a 0.1µF & 10µF parallel capacitor.  
continued on next page  
www.recom-power.com  
REV.: 1/2016  
PDR-1  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
REDIN240-24  
Efficiency vs. Load  
Power Dissipation vs Load  
25  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
20  
15  
10  
5
115VAC  
230VAC  
264VAC  
115VAC  
230VAC  
0
0
2
4
6
8
10  
12  
Load Current [A]  
0
2
4
6
8
10  
Input Current vs Load  
Power Factor vs Load over Vin  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
2.5  
2
1.5  
1
0.5  
0
115VAC  
230VAC  
Iin 115VAC [A]  
Iin 230VAC [A]  
0
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
0
2
4
6
8
10  
12  
Load Current [%]  
Load Current [A]  
REDIN240-48  
Efficiency vs. Load  
Power Dissipation vs Load  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
25  
20  
15  
10  
5
115VAC  
230VAC  
264VAC  
115VAC  
230VAC  
0
0
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Load Current [A]  
Load Current [A]  
Input Current vs Load  
Power Factor vs Load over Vin  
2.5  
2
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
1.5  
1
0.5  
Iin 115VAC [A]  
Iin 230VAC [A]  
115VAC  
230VAC  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
0
1
2
3
4
5
6
Load Current [%]  
Load Current [A]  
PDR-2  
REV.: 1/2016  
www.recom-power.com  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
REGULATION  
Parameter  
Condition  
Value  
24Vout  
48Vout  
0.4% typ. / 3% max.  
0.3% typ. / 3% max.  
Output Accuracy  
24Vout  
48Vout  
0.03% typ. / 0.5% max.  
0.04% typ. / 0.5% max.  
Line Regulation  
Load Regulation  
0% to 100% load  
0.3% typ. / 1.0% max.  
1% typ. / 5% max.  
Transient Response  
100Hz & 1kHz, 50% duty, 25% load step change  
PROTECTION  
Parameter  
Condition  
Value  
T5A, slow blow type  
Input Fuse  
Short Circuit Protection (SCP)  
continuous, auto recovery  
24Vout  
48Vout  
29-33VDC, constant voltage auto recovery  
58-63VDC, constant voltage auto recovery  
Over Voltage Protection (OVP)  
Over Voltage Category (OVC)  
Over Load Protection (OLP)  
OVC II  
Limit the current by constant power circuit  
105 5°C , detect on Heat-sink of power transistor; shut down  
O/P , auto recovery after temperature goes down  
3.0KVAC / 1minute  
Over Temperature Protection (OTP)  
I/P to O/P  
I/P to PE  
O/P to PE  
Isolation Voltage  
2.5KVAC / 1minute  
0.5kVAC / 1minute  
Isolation Resistance  
Leakage Current  
10MW min.  
I/P to O/P  
I/P to PE  
0.25mA max.  
3.5mA max.  
ON  
OFF  
Vout up to 90% of rated Vout  
Vout down to 80% of rated Vout  
Power OK LED  
Relay Contact Rating  
Max. 30V/1A or 60V/0.3 or 30VAC/0.3A Resitive Load  
Overload Capability  
Time (x) [s]  
Pout (y) [%]  
150  
3
4
140  
y
7
130  
45  
120  
100  
0
x
60  
Time [s]  
www.recom-power.com  
REV:: 1/2016  
PDR-3  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
ENVIRONMENTAL  
Parameter  
Condition  
with derating  
Value  
-25°C to +70°C  
0.3%/°C  
Operating Temperature Range  
Temperature Coefficient  
Operating Altitude  
Operating Humidity  
IP Rating  
3000m  
non-condensing  
20% - 90% RH  
IP X0  
Pollution Degree (PD)  
Shock  
PD 2  
10-500Hz 2G, 60min.  
10G /11ms, along x,y and z axis  
300 x 10³ hours  
Vibration  
MTBF  
MIL-HDBK-217F, full load, 25°C  
Thermal Dertating  
100  
80  
60  
40  
20  
0
Pout 115VAC cont.  
Pout 230VAC cont.  
-25 -20 -10  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature [°C]  
SAFETY AND CERTIFICATIONS  
Certificate Type  
Report / File Number  
Standard  
UL60950-1, 2nd Edition, 2014  
CSA C22.2 No. 60950-1-07, 2nd Edition, 2014  
Information Technology Equipment, General Requirements for Safety  
E224736  
UL508, 17th Edition, 2013  
CSA C22.2 No. 107.1-01, 3rd Edition, 2011  
Industrial Control Equipment  
E470721  
IEC60950-1, 2nd Edition 2005, +AM1:2009 + AM2:2013  
EN60950-1:2006, + A11:2009 + A1:2010 + A12:2011  
+ A2:2013  
NTEK-  
2016NT02244417S  
Information Technology Equipment - General Requirments for Safety  
EMC Compliance  
Report / Condition  
Standard / Criterion  
Information technology equipment - Radio disturbance characteristics -  
Limits and methods of measurement  
EN55022:2010 + AC:2011, Class B  
Information technology equipment - Immunity characteristics - Limits and  
methods of measurement  
EN55024:2010 + A1:2015  
Limitations on the amount of electromagnetic intererence allowed from  
digital and electronic devices  
47 CFR FCC Part 15, Subpart B: 2016  
ESD Electrostatic discharge immunity test  
Air 8kV, Contact 4kV  
3V/m  
EN61000-4-2, Criteria B, 2009  
EN61000-4-3, Criteria A, 2006  
Radiated, radio-frequency, electromagnetic field immunity test  
continued on next page  
PDR-4  
REV.: 1/2016  
www.recom-power.com  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
Fast Transient and Burst Immunity  
AC Power Port: L+N+PE 1kV  
EN61000-4-4, Criteria B, 2012  
EN61000-4-5, Criteria B, 2014  
EN61000-4-6, Criteria A, 2014  
EN61000-4-8, Criteria A, 2010  
Surge Immunity  
AC Power Port L-N 1kV, L-PE + N-PE 2kV  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
AC Power Port 3V  
50Hz, 1A/m  
Voltage Dips >95%  
Voltage Dips 30%  
Voltage Interruptions >95%  
EN61000-4-11, Criteria B, 2004  
EN61000-4-11, Criteria C, 2004  
EN61000-4-11, Criteria C, 2004  
Voltage Dips and Interruptions  
Limits of Harmonic Current Emissions  
Voltage Fluctuations & Flicker  
EN61000-3-2, Criteria A, 2014  
EN61000-3-3, Clause 5, 2013  
DIMENSION and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
Case  
Cover  
Aluminium  
Nickel plated steel  
Material  
Package Dimension (LxWxH)  
Package Weight  
without mounting clip  
114.26 x 46.0 x 124.4mm  
810g typ.  
Dimension Drawing (mm)  
12.5  
38.0  
DC OK +V +V -V -V  
10.4  
Vadj.  
DC OK LED  
Parallel Use  
Single Use  
6.85  
55.0  
28.3  
PE  
N
L
19.1  
46.0  
114.26  
123.77  
continued on next page  
REV.: 1/2016  
www.recom-power.com  
PDR-5  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
34.0  
44.0  
Terminals and Wiring  
Screw Connector  
1-6mm2  
Type  
Solid Wire  
Stranded Wire  
1-4mm2  
American Wire Gauge  
Wire Stripping Length  
Screwdriver (slotted / cross)  
AWG17-10  
8mm  
3.5mm  
Recommended tightening torque 0.5Nm-0.8Nm  
Tolerance: X.X 0.5mm  
X.XX 0.25mm  
24.75  
1.75  
INSTALLATION  
Mounting Instruction  
Mounting  
Releasing  
1
DC OK +V +V -V -V  
Vadj.  
DC OK LED  
Parallel Use  
Single Use  
N
PE  
L
2
2
„Click“  
1
PDR-6  
REV.: 1/2016  
www.recom-power.com  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
INSTALLATION  
Mounting Multiple Power Supplies  
DC OK +V +V -V -V  
DC OK +V +V -V -V  
DC OK +V +V -V -V  
Vadj.  
Vadj.  
Vadj.  
DC OK LED  
DC OK LED  
DC OK LED  
Parallel Use  
Single Use  
Parallel Use  
Single Use  
Parallel Use  
Single Use  
N
L
PE  
N
L
PE  
N
L
PE  
15mm  
15mm  
leave 15mm gap between supplies  
Parallel Operation & Phase Redundancy  
L1 L2 L3 N PE  
L N PE  
+
-
~
~
~
+
+V  
-V  
DC  
OK  
~
~
~
-
+
+
-
+V  
-V  
DC  
OK  
Load  
-
+
-
+V  
-V  
DC  
OK  
DC OK  
Single Operation:  
1) Make sure that the front panel switch is set to “single Use.”  
2) The output voltage can be increased by trim pot to compensate any cable losses.  
Parallel Operation:  
1) Make sure that the front panel switch is set to “single Use” on each power supply.  
2) Adjust each power supply to the exact same output voltage with same load and cooling conditions.  
3) Set the front panel switches to “Parallel Use.” Use the same wire length for each power supply (star connection) and energize all units at the  
same time to avoid triggering overload protection.  
Derate the maximum output power to 90% of nominal ratings.  
For operation with more than three power supplies in parallel or series operation, please contact RECOM technical support for advice.  
www.recom-power.com  
REV.: 1/2016  
PDR-7  
REDIN240  
AC/DC Converter  
Specifications (measured @ ta = 25°C, rated Vin, rated load and after warm up)  
Series  
Application Circuit  
T5A  
+V  
-V  
L
Input  
Filter  
Output  
Filter  
Power Stage  
N
E
DC  
OK  
Relay  
OTP  
Shut-  
Down  
Protection  
LED  
Vadj.  
OVP  
Shut-  
Down  
Output  
Voltage  
Regulation  
OCP  
Limit  
Single /  
Parallel  
PACKAGKING INFORMATION  
Parameter  
Type  
Value  
140.0 x 63.0 x 142.0mm  
1pcs  
Packaging Dimension (LxWxH)  
Packaging Quantity  
cardboard box  
cardboard box  
Storage Temperature Range  
Storage Humidity  
-40°C to +85°C  
5% - 95% RH  
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written  
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer  
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.  
PDR-8  
REV.: 1/2016  
www.recom-power.com  

相关型号:

REDIN240-24

Universal AC Input
RECOM

REDIN240-24/3AC

240 Watt 3 Phase DIN-Rail Power Supply
RECOM

REDIN240-3AC

240 Watt 3 Phase DIN-Rail Power Supply
RECOM

REDIN240-48

Universal AC Input
RECOM

REDIN45

45 Watt DIN-Rail Power Supply
RECOM

REDIN45-12

45 Watt DIN-Rail Power Supply
RECOM

REDIN45-24

45 Watt DIN-Rail Power Supply
RECOM

REDIN480

480 Watt DIN-Rail Power Supply
RECOM

REDIN480-24

480 Watt DIN-Rail Power Supply
RECOM

REDIN480-24/3AC

480 Watt 3 Phase DIN-Rail Power Supply
RECOM

REDIN480-3AC

480 Watt 3 Phase DIN-Rail Power Supply
RECOM

REDIN480-48

480 Watt DIN-Rail Power Supply
RECOM