PXI-4072 [NI]
61⁄2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter; 61/2位数字万用表, 1.8 MS / s的隔离数字化仪和LCR表![PXI-4072](http://pdffile.icpdf.com/pdf1/p00179/img/icpdf/PXI-4_1007848_icpdf.jpg)
型号: | PXI-4072 |
厂家: | ![]() |
描述: | 61⁄2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter |
文件: | 总5页 (文件大小:718K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1
6 ⁄ -Digit Digital Multimeter, 1.8 MS/s
2
Isolated Digitizer, and LCR Meter
NI PXI-4072
• Multifunction device
Operating Systems
• Windows Vista/XP/2000
• Linux®
1
• 6 ⁄
2-digit digital multimeter
• 1.8 MS/s isolated digitizer
• LCR meter (inductance,
capacitance, and resistance)
• 20 built-in measurements
• 10- to 23-bit flexible resolution
• Built-in self-calibration
Recommended Software
• LabVIEW
• LabVIEW Real-Time Module
• LabWindows™/CVI
• LabVIEW SignalExpress
•
300 VDC/Vrms isolation
• 425 Vp AC measurements
Driver Software (included)
• NI-DMM driver
• DMM Express VI for LabVIEW
• DMM Soft Front Panel
Calibration
• Gain, temperature, and offset
self-calibration
• 2-year external calibration cycle
Mode
Capacitance
Ranges
300 pF, 1 nF, 10 nF, 100 nF, 1 µF, 10 µF
100 µF, 1000 µF, 10,000 µF
10 µH, 100 µH
Reading Rate (S/s)
Overview
20
3
40
20
3
The National Instruments PXI-4072 FlexDMM, based on the NI 4070
architecture, combines the functionality found in three common test
instruments – a digital multimeter, an LCR meter, and a digitizer. This
functionality provides engineers with the 20 most common test functions
in a compact 3U PXI module, including voltage, current, capacitance,
inductance, temperature, and resistance. Integrating these measurements
in a PXI module reduces test system size and cost, increases throughput,
and shortens test development time, making the NI PXI 4072 an
excellent fit for use in automated tests on both the production floor and
Inductance
1 mH, 10 mH
100 mH, 1 H, 5 H
Table 1. PXI-4072 Key Specifications
in an R&D environment.
1
The PXI-4072 offers a DC reading rate from 10 kS/s at 4 ⁄
2
digits
to 5 S/s at 7 digits. As a digitizer, the FlexDMM can acquire both AC-
and DC-coupled voltage and current waveforms up to 300 V and 1 A
input at a maximum sampling rate of 1.8 MS/s. As an LCR meter, the
FlexDMM delivers 0.25 percent basic accuracy for both inductance and
capacitance at measurement rates up to 40 S/s. Using the intuitive
NI-DMM instrument driver, you can quickly change from function to
function in a single application programming interface (API).
Ordering Information
NI PXI-4072............................................................................778270-01
Includes the P-1 Probe Set, NI-DMM, DMM Express VI, and DMM Soft Front Panel.
Recommended Switching and Accessories
NI PXI-2527
300 V multiplexer switch ................................................ 778572-27
NI PXI-2530
128x1 multiplexer switch..................................................778660-01
P-1 Probe Set (standard probe) ............................................761000-01
P-2 Probe Set (additional probe) ..........................................184698-01
P-3 Probe Set (banana plug to bare wire) ............................185692-01
10 A current shunt, CSM-10A ..............................................777488-02
BUY NOW!
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/dmm.
1
6 ⁄ -Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
2
Specifications
Specifications subject to change without notice.
For the most current and complete specifications, visit ni.com/modularinstruments.
DC Functions
DC Voltage ±(ppm of reading ꢀ ppm of range)
Tempco/°C
Without
Self-Cal
4 + 5
2 + 1
1 + 1
With
Input
24 Hr
Tcal ±1 °C
10 + 10
6 + 2
4 + 2
6 + 2
90-Day
Tcal ±± °C
30 + 20
20 + 6
20 + 6
30 + 6
2-Year
Tcal ±± °C
40 + 20
25 + 6
25 + 6
35 + 6
Self-Cal
0.3 + 0.3
0.3 + 0.3
0.3 + 0.3
0.3 + 0.3
0.3 + 0.3
Range
100 mV
1 V
Resolution
100 nV
1 µV
Resistance
>10 GΩ,10 MΩ
>10 GΩ,10 MΩ
>10 GΩ,10 MΩ
10 MΩ
10 V
10 µV
100 V
300 V
100 µV
1 mV
4 + 1
4 + 3
10 MΩ
6 + 6
30 + 20
35 + 20
DC Current ±(ppm of reading ꢀ ppm of range)
Range
20 mA
200 mA
1 A
Resolution
10 nA
100 nA
1 µA
Burden Voltage (typical)
<20 mV
Noise (ppm of range rms)
2-Year
Tempco/°C
20
3
3
400 + 75
400 + 20
500 + 20
8 + 1
8 + 0.2
8 + 0.4
<200 mV
<800 mV
Resistance (4- and 2-wire) ±(ppm of reading ꢀ ppm of range)
Tempco/°C
Without
Self-Cal
8 + 1
8 + 0.1
8 + 0.1
8 + 0.5
8 + 1
30 + 3
200 + 10
With
Self-Cal
0.8 + 1
0.8 + 0.1
0.8 + 0.1
0.8 + 0.5
0.8 + 1
Max Test
Voltage
100 mV
1 V
1 V
1 V
10 V
10 V
10 V
24 Hr
Tcal ±1 °C
15 + 10
12 + 2
12 + 2
15 + 2
20 + 2
100 + 2
900 + 20
90-Day
Tcal ±± °C
50 + 10
50 + 3
50 + 3
50 + 6
60 + 10
200 + 10
1,800 + 40
2-Year
Tcal ±± °C
80 + 10
80 + 3
80 + 3
80 + 6
90 + 10
400 + 10
2,000 + 40
Range
100 Ω
1 kΩ
Resolution
100 µΩ
1 mΩ
Test Current
1 mA
1 mA
10 kΩ
100 kΩ
1 MΩ
10 mΩ
100 mΩ
1 Ω
100 µA
10 µA
10 µA
10 MΩ
100 MΩ
10 Ω
100 Ω
1 µA
1 µA || 10 MΩ
30 + 3
200 + 10
Diode Test
Range
Resolution
Test Current
Accuracy
10 V
10 µV
1 µA, 10 µA, 100 µA, 1 mA
Add 20 ppm of reading to 10 VDC voltage specifications
AC Functions
Digits
6 ⁄2
Reading Rate
0.25 S/s
2.5 S/s
25 S/s
100 S/s
Bandwidth
1 Hz to 300 kHz
10 Hz to 300 kHz
100 Hz to 300 kHz
400 Hz to 300 kHz
20 to 300 kHz
1
1
6 ⁄
2
1
6 ⁄
2
1
6 ⁄
2
1
5 ⁄
2
1.0 kS/s
AC Voltage 2-Year ± (% of reading ꢀ % of range), 23 °C ±± °C
Range (rms)
50 mV
500 mV
5 V
Peak Voltage
105 mV
1.05 V
Resolution
100 nV
1 µV
1 to 40 Hz
0.1 + 0.04
40 Hz to 20 kHz 20 to ±0 kHz ±0 to 100 kHz
100 to 300 kHz
0.05 + 0.04
0.09 + 0.04
0.5 + 0.08
3 + 0.1
0.1 + 0.01
0.05 + 0.02
0.09 + 0.02
0.5 0.02
3 + 0.05
10.5 V
10 µV
50 V
300 V
105 V
450 V
100 µV
1 mV
Tempco/°C
0.001 + 0.001
0.001 + 0.001
0.001 + 0.001 0.001 + 0.001
0.01 + 0.01
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
1
6 ⁄ -Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
2
AC Current 2-Year ±(% of reading ꢀ % of range)
Range (rms)
10 mA
100 mA
1 A
Peak Current
20 mA
200 mA
2 A
Resolution
10 nA
100 nA
1 µA
Burden Voltage (rms)
<10 mV
1 Hz to 20 kHz
0.04 + 0.02
0.04 + 0.02
0.1 + 0.02
Tempco/°C
0.001 + 0.0001
0.001 + 0.0001
0.001 + 0.0001
<100 mV
<800 mV
Frequency and Period
Input Range
50 mV to 300 V
Frequency Range
1 Hz to 500 kHz
Period Range
1 s to 2 µs
Resolution
2-Year Accuracy % of Reading
1
6 ⁄
2
digits
0.01
Capacitance and Inductance (PXI-4072 only)
Capacitance ±(% of reading ꢀ % of range), 23 °C ±10 °C
Range
300 pF
1 nF
10 nF
100 nF
1 µF
Resolution
0.05 pF
0.1 pF
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
1 µF
2-year
Tempco/°C (0 to ±± °C) Effective Test Current
Effective Frequency
Default Model
Parallel
Parallel
Parallel
Parallel
Series
0.15 + 0.5
0.15 + 0.1
0.15 + 0.1
0.15 + 0.1
0.18 + 0.1
0.18 + 0.1
0.18 + 0.1
0.18 + 0.1
0.18 + 0.1
0.01 + 0.025
0.01 + 0.003
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
0.01 + 0.001
160 nA
330 nA
330 nA
3.3 µA
100 µA
1 mA
1 mA
1 mA
1 mA
3 kHz
3 kHz
3 kHz
3 kHz
1 kHz
1 kHz
91 Hz
91 Hz
91 Hz
10 µF
Series
Series
Series
Series
100 µF
1,000 µF
10,000 µF
Inductance ±(% of reading ꢀ % of range), 23 °C ±10 °C
Range
10 µH
100 µH
1 mH
10 mH
100 mH
1 H
Resolution
1 nH
10 nH
100 nH
1 µH
10 µH
2-year
0.5 + 1
Tempco/°C (0 to ±± °C) Effective Test Current
Effective Frequency
30 kHz
Default Model
Series
0.01 + 0.01
0.01 + 0.01
330 µA
330 µA
330 µA
3.3 µA
33 µA
0.2 + 0.1
0.2 + 0.1
0.15 + 0.1
0.15 + 0.1
0.18 + 0.1
0.18 + 0.1
30 kHz
3 kHz
3 kHz
273 Hz
273 Hz
273 Hz
Series
Series
Series
Series
Series
Series
0.01 + 0.001
0.005 + 0.001
0.005 + 0.001
0.007 + 0.001
0.007 + 0.001
100 µH
1 mH
3.3 µA
330 nA
5 H
Capacitance and Inductance, General Specifications
Mode
Capacitance
Ranges
300 pF, 1 nF, 10 nF, 100 nF, 1 µF, 10 µF
100 µF, 1,000 µF, 10,000 µF
10 µH, 100 µH
Reading Rate
20 S/s
3 S/s
40 S/s
20 S/s
3 S/s
Inductance
1 mH, 10 mH
100 mH, 1 H, 5 H
Isolated Digitizer Mode
Acquisition System
Available sample rates..........................................................
Variable resolution................................................................. 10 to 23 bits
1.8 MS/s
n
5
,
where n = 1, 2, 3,…1.8 x 10
Available functions ................................................................ Voltage and current
Voltage ranges....................................................................... 100 mV to 300 V (DC or AC coupled)
Current ranges ....................................................................... 20 mA to 1 A
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
1
6 ⁄ -Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
2
DC Voltage ±(ppm of reading ꢀ ppm of range)
Range
100 mV
1 V
10 V
100 V
300 V
Input Impedance Flatness Error (20 kHz) Bandwidth (-3 dB) THD 1 kHz Signal (-1 dBFS) THD 1 kHz Signal (-1 dBFS)
>10 GΩ,1 MΩ
>10 GΩ,1 MΩ
>10 GΩ,1 MΩ
1 MΩ
-0.03 dB
-0.03 dB
-0.03 dB
-0.03 dB
-0.03 dB
300 kHz
300 kHz
300 kHz
300 kHz
300 kHz
-104 dB
-109 dB
-96 dB
-96 dB
-98 dB
-78 dB
-83 dB
-70 dB
-70 dB
-72 dB
1 MΩ
DC Current ±(ppm of reading ꢀ ppm of range)
Range
20 mA
200 mA
1 A
Resolution
10 nA
100 nA
1 µA
Burden Voltage (typical)
<20 mV
Flatness Error (20 kHz)
0.01 dB
Bandwidth (-3 dB)
430 kHz
<200 mV
<800 mV
0.01 dB
0.01 dB
430 kHz
400 kHz
Certifications and Compliance
Safety
IEC 61010-1; EN 61010-1; UL 61010-1; CSA 61010-1
Installation category.............................................................. II
Pollution degree.....................................................................
Electromagnetic compatibility
2
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
4
NI Services and Support
NI has the services and support to meet
Local Sales and Technical Support
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure
using NI products. Visit ni.com/training.
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • 800 813 3693
*342574B-01*
342574B-01
2007-9223-101-D-A
National Instruments • info@ni.com
© 2007 National Instruments Corporation. All rights reserved. CVI, FlexDMM, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI,
®
and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Linux is the registered trademark of Linus Torvalds
in the U.S. and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a
business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
相关型号:
©2020 ICPDF网 联系我们和版权申明