PXI-5142 [NI]

14-Bit 100 MS/s Digitizer with Onboard Signal Processing; 14位100 MS / s数字化仪具有板载信号处理
PXI-5142
型号: PXI-5142
厂家: National Instruments    National Instruments
描述:

14-Bit 100 MS/s Digitizer with Onboard Signal Processing
14位100 MS / s数字化仪具有板载信号处理

文件: 总77页 (文件大小:1265K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NI PXI/PCI-5142 Specifications  
14-Bit 100 MS/s Digitizer with Onboard Signal Processing  
̭͈Ρ΅νιϋΠ͉ͅȂ඾ུ
βȜΐ͜
܄
̞̳ͦ̀͘͘ȃ  
This document lists the specifications for the NI PXI/PCI-5142 (NI 5142)  
high-speed digitizer. Unless otherwise noted, the following conditions were  
used for each specification:  
All filter settings  
All impedance selections  
Sample clock set to 100 MS/s  
Typical values are used to define an average unit measured at ambient  
temperatures of 15 °C to 35 °C. Specifications are subject to change  
without notice. For the most recent NI 5142 specifications, visit ni.com/  
manuals.  
To access NI 5142 documentation, navigate to Start»All Programs»  
National Instruments»NI-SCOPE»Documentation.  
Hot Surface If the NI 5142 has been in use, the device or the shield may exceed safe  
handling temperatures and may cause burns. Allow the NI 5142 to cool before touching the  
shield or removing the device from the chassis or PC. Refer to the Environment section for  
operating temperatures.  
Contents  
Vertical.................................................................................................... 2  
Analog Input (Channel 0 and Channel 1) ........................................ 2  
Horizontal................................................................................................ 13  
Sample Clock................................................................................... 13  
Phase-Locked Loop (PLL) Reference Clock................................... 16  
CLK IN (Sample Clock and Reference Clock Input,  
Front Panel Connector)................................................................. 16  
CLK OUT (Sample Clock and Reference Clock Output,  
Front Panel Connector)................................................................. 17  
Trigger .....................................................................................................17  
Reference (Stop) Trigger..................................................................17  
TRIG (External Trigger, Front Panel Connector) ............................19  
PFI 0 and PFI 1 (Programmable Function Interface,  
AUX Front Panel Connectors)..............................................................20  
TClk Specifications .................................................................................21  
Waveform Specifications ........................................................................22  
Onboard Signal Processing (OSP)...........................................................23  
Calibration ...............................................................................................31  
Power.......................................................................................................31  
Software...................................................................................................32  
Environment ............................................................................................32  
NI PXI-5142.....................................................................................32  
NI PCI-5142 .....................................................................................33  
Safety, Electromagnetic Compatibility, and CE Compliance .................34  
Safety................................................................................................34  
Electromagnetic Compatibility.........................................................34  
CE Compliance.................................................................................34  
Environmental Management ............................................................35  
Physical....................................................................................................35  
Front Panel Connectors ....................................................................35  
Dimensions and Weight ...................................................................36  
Where to Go for Support .........................................................................38  
Vertical  
Analog Input (Channel 0 and Channel 1)  
Specification  
Value  
Two (simultaneously sampled)  
Comments  
Number of  
Channels  
Connector  
BNC  
Impedance and Coupling  
Input  
Impedance  
50 Ω 2.0%  
1 MΩ 0.75% in parallel  
with a typical capacitance selectable.  
of 27 pF 2 pF  
Software  
Input Coupling  
AC, DC, GND  
AC coupling  
available on  
1 MΩ only.  
NI PXI/PCI-5142 Specifications  
2
ni.com  
Specification  
Value  
Comments  
Voltage Levels  
Full Scale (FS)  
Input Range and  
Programmable  
Vertical Offset  
50 Ω  
Vertical Offset  
1 MΩ  
Vertical  
–10 dBm to  
+24 dBm in  
50 Ω mode.  
Range  
Range  
Offset Range  
(V)  
(Vpk-pk  
)
Range (V)  
(Vpk-pk  
0.2  
0.4  
1
)
0.2  
0.4  
1
0.1  
0.2  
0.5  
1
0.1  
0.2  
0.5  
1
2
2
4
2
4
2
10  
10  
20  
5
Maximum Input  
Overload  
50 Ω  
7 Vrms with |Peaks| 10 V  
1 MΩ  
|Peaks| 42 V  
© National Instruments Corporation  
3
NI PXI/PCI-5142 Specifications  
Specification  
Accuracy  
Value  
Comments  
Resolution  
14 bits  
Range  
DC Accuracy  
(Programmable  
Vertical  
Within 5 °C of  
self-calibration  
temperature.  
(Vpk-pk  
)
50 Ω and 1 MΩ  
0.2, 0.4  
NI PXI-5142:  
(0.65% of Input + 1.0 mV)  
Offset = 0 V)  
NI PCI-5142:  
(0.65% of Input + 2.0 mV)  
1
2
NI PXI-5142:  
(0.65% of Input + 1.2 mV)  
NI PCI-5142:  
(0.65% of Input + 2.0 mV)  
NI PXI-5142:  
(0.65% of Input + 1.6 mV)  
NI PCI-5142:  
(0.65% of Input + 2.0 mV)  
4, 10  
NI PXI/PCI-5142:  
(0.65% of Input + 8.0 mV)  
20  
NI PXI/PCI-5142:  
(1 MΩ only)  
(0.65% of Input + 13.0 mV)  
Programmable  
Vertical Offset  
Accuracy  
0.4% of offset setting  
Within 5 °C of  
self-calibration  
temperature.  
DC Drift  
Range  
(Vpk-pk  
)
50 Ω and 1 MΩ  
0.2, 0.4, 1, and 2  
(0.057% of Input + 0.006% of FS  
+ 100 μV) per °C  
4, 10, and  
20 (1 MΩ only)  
(0.057% of Input + 0.006% of FS  
+ 900 µV) per °C  
AC Amplitude  
Accuracy  
50 Ω  
1 MΩ  
Within 5 °C of  
self-calibration  
temperature.  
0.06 dB  
( 0.7%) at 50 kHz  
0.09 dB  
( 1.0%) at 50 kHz  
NI PXI/PCI-5142 Specifications  
4
ni.com  
Specification  
Value  
Comments  
Crosstalk,  
Typical  
–100 dB at 10 MHz  
CH 0 to/from  
CH 1, External  
Trigger to CH 0  
or CH 1.  
Bandwidth and Transient Response  
Bandwidth  
(–3 dB)  
Range  
Filters off.  
(Vpk-pk  
)
50 Ω and 1 MΩ  
* 78 MHz above  
40 ºC.  
All ranges  
except 0.2  
100 MHz  
0.2  
80 MHz up to 40 ºC*  
Rise/Fall Time,  
Typical  
Range  
(Vpk-pk  
)
50 Ω and 1 MΩ  
All ranges  
except 0.2  
3.5 ns  
0.2  
4.2 ns  
Bandwidth  
Limit Filters  
Noise Filter  
Antialias Filter  
Only one filter  
can be enabled  
at any given  
time. The  
antialias filter  
is enabled by  
default.  
20 MHz  
2-pole Bessel filter  
40 MHz (–6 dB, typical)  
35 MHz (–3 dB)  
6-pole Chebyshev filter  
AC-Coupling  
Cutoff (–3 dB)  
12 Hz  
AC coupling  
available on  
1 MΩ only.  
Passband  
Flatness  
Filter  
Settings  
Range  
(Vpk-pk  
Referenced  
to 50 kHz.  
)
50 Ω and 1 MΩ  
Filters Off  
All  
0.4 dB DC to 20 MHz  
ranges  
except  
0.2  
1 dB 20 MHz to 50 MHz  
0.2  
0.4 dB DC to 20 MHz  
1 dB 20 MHz to 40 MHz  
Antialias  
Filter On  
All  
ranges  
1.2 dB DC to 16 MHz  
1.6 dB 16 MHz to  
32 MHz  
© National Instruments Corporation  
5
NI PXI/PCI-5142 Specifications  
1.0  
0.0  
–1.0  
–2.0  
–3.0  
–4.0  
–5.0  
–6.0  
–7.0  
–8.0  
–9.0  
–10.0  
Filters Off  
Noise Filter On  
Antialias Filter On  
1 M  
10 M  
100 M 150 M  
Frequency (Hz)  
Figure 1. NI 5142 Frequency Response (Typical)  
NI PXI/PCI-5142 Specifications  
6
ni.com  
Specification  
Value  
Comments  
Spectral Characteristics  
Spurious Free  
Range  
10 MHz,  
Dynamic Range  
with Harmonics  
(SFDR), Typical  
(Vpk-pk  
0.2  
0.4  
1
)
50 Ω  
1 MΩ  
70 dBc  
70 dBc  
70 dBc  
70 dBc  
70 dBc  
60 dBc  
60 dBc  
–1 dBFSinput  
signal.  
75 dBc  
75 dBc  
75 dBc  
75 dBc  
65 dBc  
65 dBc  
N/A  
Includes the  
2nd through  
the 5th  
harmonics.  
2
Measured  
4
from DC to  
50 MHz on  
NI PXI-5142.  
10  
20  
Measured  
(1 MΩ only)  
from 5 kHz to  
50 MHz on  
NI PCI-5142.  
Total Harmonic  
Distortion  
(THD),  
Range  
10 MHz,  
–1 dBFSinput  
signal.  
(Vpk-pk  
0.2  
0.4  
1
)
50 Ω  
1 MΩ  
–75 dBc  
–75 dBc  
–75 dBc  
–73 dBc  
–63 dBc  
–63 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–58 dBc  
–58 dBc  
Typical  
Includes the  
2nd through  
the 5th  
harmonics.  
2
4
10  
20  
N/A  
(1 MΩ only)  
Intermodulation  
Distortion,  
Typical  
0.2 Vpk-pk to 2.0 Vpk-pk Ranges on 50 Ω Input  
Two tones at  
10.2 MHz and  
11.2 MHz.  
–75 dBc  
Each tone is  
–7 dBFS.  
© National Instruments Corporation  
7
NI PXI/PCI-5142 Specifications  
Specification  
Value  
50 Ω  
Filters Antialias  
Comments  
Signal-to-Noise  
Ratio (SNR),  
Typical  
1 MΩ  
Antialias  
10 MHz,  
–1 dBFSinput  
signal.  
Range  
Filters  
Off  
(Vpk-pk  
)
Off  
Filter On  
60 dB  
62 dB  
62 dB  
62 dB  
Filter On  
60 dB  
62 dB  
62 dB  
62 dB  
62 dB  
Excludes  
harmonics.  
0.2  
0.4  
1
60 dB  
62 dB  
62 dB  
62 dB  
56 dB  
61 dB  
62 dB  
62 dB  
61 dB  
Measured  
from DC to  
50 MHz.  
2
4
Signal to Noise  
and Distortion  
(SINAD),  
50 Ω  
Filters Antialias  
1 MΩ  
10 MHz,  
–1 dBFSinput  
signal.  
Range  
Filters  
Off  
Antialias  
Filter On  
(Vpk-pk  
)
Off  
Filter On  
60 dB  
62 dB  
62 dB  
62 dB  
Typical  
Includes  
harmonics.  
0.2  
0.4  
1
60 dB  
62 dB  
62 dB  
62 dB  
56 dB  
60 dB  
61 dB  
61 dB  
60 dB  
59 dB  
61 dB  
61 dB  
61 dB  
61 dB  
Measured  
from DC to  
50 MHz.  
2
4
00  
–10  
–20  
30  
–40  
–50  
–60  
–70  
80  
–90  
–100  
–110  
10.24 MHz, –1 dBFS Input Signal  
0
5 M 10 M 15 M 20 M 25 M 30 M 35 M 40 M 45 M 50 M  
Frequency (Hz)  
Figure 2. NI 5142 Dynamic Performance, 50 Ω, 1 Vpk-pk Range (Typical)  
NI PXI/PCI-5142 Specifications  
8
ni.com  
Specification  
Value  
50 Ω  
Comments  
50 Ω  
terminator  
connected  
to input.  
RMS Noise  
(Noise Filter On)  
Range  
(Vpk-pk  
)
1 MΩ  
0.2  
NI PXI-5142:  
46 μVrms  
(0.023% FS)  
NI PXI-5142:  
60 μVrms  
(0.030% FS)  
NI PCI-5142:  
56 μVrms  
(0.028% FS)  
NI PCI-5142:  
72 μVrms  
(0.036% FS)  
0.4  
1
92 μVrms  
92 μVrms  
(0.023% FS)  
(0.023% FS)  
230 μVrms  
(0.023% FS)  
230 μVrms  
(0.023% FS)  
2
460 μVrms  
(0.023% FS)  
460 μVrms  
(0.023% FS)  
4
920 μVrms  
(0.023% FS)  
920 μVrms  
(0.023% FS)  
10  
2.3 mVrms  
2.3 mVrms  
(0.023% FS)  
(0.023% FS)  
20  
4.6 mVrms  
(0.023% FS)  
N/A  
(1 MΩ only)  
© National Instruments Corporation  
9
NI PXI/PCI-5142 Specifications  
Specification  
Value  
50 Ω  
Comments  
50 Ω  
terminator  
connected  
to input.  
RMS Noise  
(Antialias  
Filter On)  
Range  
(Vpk-pk  
)
1 MΩ  
0.2  
NI PXI-5142:  
66 μVrms  
(0.033% FS)  
NI PXI-5142:  
80 μVrms  
(0.040% FS)  
NI PCI-5142:  
82 μVrms  
(0.041% FS)  
NI PCI-5142:  
96 μVrms  
(0.048% FS)  
0.4  
1
100 μVrms  
120 μVrms  
(0.025% FS)  
(0.030% FS)  
250 μVrms  
(0.025% FS)  
300 μVrms  
(0.030% FS)  
2
500 μVrms  
(0.025% FS)  
600 μVrms  
(0.030% FS)  
4
1 mVrms  
1.2 mVrms  
(0.025% FS)  
(0.030% FS)  
10  
2.5 mVrms  
3 mVrms  
(0.025% FS)  
(0.030% FS)  
20  
6 mVrms  
(0.030% FS)  
N/A  
(1 MΩ only)  
NI PXI/PCI-5142 Specifications  
10  
ni.com  
Specification  
Value  
50 Ω  
Comments  
50 Ω  
terminator  
connected  
to input.  
RMS Noise  
(Filters Off)  
Range  
(Vpk-pk  
)
1 MΩ  
0.2  
NI PXI-5142:  
66 μVrms  
(0.033% FS)  
NI PXI-5142:  
110 μVrms  
(0.055% FS)  
NI PCI-5142:  
90 μVrms  
(0.045% FS)  
NI PCI-5142:  
110 μVrms  
(0.055% FS)  
0.4  
1
100 μVrms  
160 μVrms  
(0.025% FS)  
(0.040% FS)  
250 μVrms  
(0.025% FS)  
300 μVrms  
(0.030% FS)  
2
500 μVrms  
(0.025% FS)  
600 μVrms  
(0.030% FS)  
4
1 mVrms  
1.6 mVrms  
(0.025% FS)  
(0.040% FS)  
10  
2.5 mVrms  
3 mVrms  
(0.025% FS)  
(0.030% FS)  
20  
6 mVrms  
(0.030% FS)  
N/A  
(1 MΩ only)  
© National Instruments Corporation  
11  
NI PXI/PCI-5142 Specifications  
60 n  
55 n  
50 n  
45 n  
40 n  
35 n  
30 n  
25 n  
20 n  
15 n  
10 n  
5 n  
1 n  
1 k  
10 k  
100 k  
1 M  
10 M  
24 M  
Frequency (Hz)  
Figure 3. Representation of NI 5142 Spectral Noise Density on 0.2 V Range,  
Noise Filter Enabled, 1 MΩ Input Impedance  
–145.000  
–147.500  
–150.000  
–152.500  
1.0 k  
10.0 k  
100.0 k  
1.0 M  
10.0 M  
50.0 M  
Frequency (Hz)  
Figure 4. Representation of NI 5142 Spectral Noise Density on 0.2 V Range,  
Full Bandwidth, 50 Ω Input Impedance  
NI PXI/PCI-5142 Specifications  
12  
ni.com  
Horizontal  
Sample Clock  
Specification  
Value  
Comments  
Sources  
NI PXI-5142  
NI PCI-5142  
* Internal Sample Clock is  
locked to the Reference  
Clock or derived from the  
onboard VCXO.  
Internal, Onboard  
Clock (internal  
VCXO)*  
Internal, Onboard Clock  
(internal VCXO)*  
External, CLK IN (front  
panel SMB connector)  
External, CLK IN  
(front panel  
SMB connector)  
External,  
PXI Star Trigger  
(backplane  
connector)  
Onboard Clock (Internal VCXO)  
Sample Rate  
Range  
Real-Time  
Sampling  
(Single Shot)  
Random Interleaved  
Sampling (RIS)  
* In normal operation mode  
(non-OSP mode), divide by  
n decimation is used for all  
rates less than 100 MS/s.  
For more information about  
Sample Clock and  
1.526 kS/s to  
100 MS/s*  
200 MS/s to 2 GS/s in  
multiples of 100 MS/s  
decimation, refer to the  
NI High-Speed Digitizers  
Help.  
Non-OSP decimation does  
not protect the acquired data  
from undersampling  
aliasing. Non-OSP  
decimation and OSP  
decimation are mutually  
exclusive (that is, they  
cannot be used at the same  
time).  
Phase Noise  
Density,  
Typical  
<–100 dBc/Hz at 100 Hz  
<–120 dBc/Hz at 1 kHz  
<–130 dBc/Hz at 10 kHz  
10 MHz input signal  
© National Instruments Corporation  
13  
NI PXI/PCI-5142 Specifications  
Specification  
Value  
Comments  
Sample Clock  
Jitter, Typical  
1 ps rms (100 Hz to 100 kHz)  
2 ps rms (100 Hz to 1 MHz)  
Includes the effects of  
the converter aperture  
uncertainty and the clock  
circuitry jitter. Excludes  
trigger jitter.  
Timebase  
Frequency  
100 MHz  
Timebase  
Accuracy  
Not Phase-Locked  
to Reference Clock  
Phase-Locked to  
Reference Clock  
25 ppm  
Equal to the Reference  
Clock accuracy  
Sample Clock  
Delay Range  
1 Sample Clock period  
10 ps  
Sample Clock  
Delay  
Resolution  
External Sample Clock  
Sources NI PXI-5142  
NI PCI-5142  
CLK IN (front panel CLK IN (front panel  
SMB connector)  
SMB connector)  
PXI Star Trigger  
(backplane  
connector)  
NI PXI/PCI-5142 Specifications  
14  
ni.com  
Specification  
Value  
Comments  
Frequency  
Range  
30 MHz to 105 MHz (CLK IN)  
30 MHz to 80 MHz (PXI Star Trigger)  
In normal operation mode  
(non-OSP mode), divide by  
n decimation is available  
where 1 n 65,535.  
For more information about  
Sample Clock and  
decimation, refer to the  
NI High-Speed Digitizers  
Help.  
Non-OSP decimation does  
not protect the acquired data  
from undersampling  
aliasing. Non-OSP  
decimation and OSP  
decimation are mutually  
exclusive (that is, they  
cannot be used at the same  
time).  
Duty Cycle  
Tolerance  
45% to 55%  
Sample Clock Exporting  
Exported  
Sample Clock  
Destinations  
Maximum  
Frequency  
* Decimated Sample Clock  
only.  
Destination  
CLK OUT (front panel  
SMB connector)  
105 MHz  
PXI_Trig <0..6>  
(backplane connector)*  
20 MHz  
PFI <0..1> (front panel 9-pin 25 MHz  
mini-circular DIN  
connector)*  
RTSI<0..6>*  
20 MHz  
© National Instruments Corporation  
15  
NI PXI/PCI-5142 Specifications  
Phase-Locked Loop (PLL) Reference Clock  
Specification  
Sources  
Value  
Comments  
NI PXI-5142  
NI PCI-5142  
PXI_CLK10 (backplane  
connector)  
RTSI 7  
CLK IN (front panel SMB  
CLK IN (front panel SMB connector)  
connector)  
Frequency Range  
1 MHz to 20 MHz in 1 MHz increments.  
Default of 10 MHz.  
The PLL Reference Clock frequency has to be accurate  
to 50 ppm.  
Duty Cycle  
Tolerance  
45% to 55%  
Exported  
NI PXI-5142  
NI PCI-5142  
Reference Clock  
Destinations  
CLK OUT (front panel  
SMB connector)  
CLK OUT (front panel  
SMB connector)  
PFI <0..1> (front panel  
9-pin mini-circular  
DIN connector)  
PFI <0..1> (front panel  
9-pin mini-circular  
DIN connector)  
PXI_Trig <0..7>  
RTSI <0..7>  
(backplane connector)  
CLK IN (Sample Clock and Reference Clock Input,  
Front Panel Connector)  
Specification  
Value  
Comments  
Input Voltage  
Range  
Sine wave: 0.65 Vpk-pk to 2.8 Vpk-pk (0 dBm to 13 dBm)  
Square wave: 0.2 Vpk-pk to 2.8 Vpk-pk  
Maximum Input  
Overload  
7 Vrms with |Peaks| 10 V  
Overvoltage and  
reverse polarity  
protected.  
Impedance  
Coupling  
50 Ω  
AC  
NI PXI/PCI-5142 Specifications  
16  
ni.com  
CLK OUT (Sample Clock and Reference Clock Output,  
Front Panel Connector)  
Specification  
Output Impedance  
Logic Type  
Value  
Comments  
50 Ω  
3.3 V CMOS  
48 mA  
Maximum Drive  
Current  
Trigger  
Reference (Stop) Trigger  
Specification  
Value  
Comments  
Trigger Types  
and Sources  
Types  
Sources  
Refer to the  
following  
sections and  
NI High-Speed  
Digitizers Help  
for more  
informationabout  
what sources are  
available for each  
trigger type.  
Edge, Window, Hysteresis,  
Video, Digital, Immediate,  
and Software  
CH 0, CH 1, TRIG,  
PXI_Trig <0..6>,  
PFI <0..1>,  
PXI Star Trigger, Software,  
and RTSI <0..6>  
TDC  
On  
Onboard Clock  
100 ps  
10 ns  
External Clock  
N/A  
TDC = Time  
to Digital  
Conversion  
Circuit.  
Time  
Resolution  
Off  
External Clock Period  
Rearm Time  
10 μs  
TDC  
Holdoff set to 0  
Rearm Time  
On  
Off  
2 μs  
© National Instruments Corporation  
17  
NI PXI/PCI-5142 Specifications  
Specification  
Value  
Onboard Clock  
Comments  
Holdoff  
TDC  
On  
External Clock  
N/A  
10 μs to 171.79 s  
2 μs to 171.79 s  
Off  
200 × (External Clock  
Period) to  
(232 – 1) × (External Clock  
Period)  
Analog Trigger (Edge, Window, and Hysteresis Trigger Types)  
Sources  
CH 0 (front panel BNC connector)  
CH 1 (front panel BNC connector)  
TRIG (front panel BNC connector)  
Trigger Level  
Range  
CH 0, CH 1  
100% FS  
TRIG (External Trigger)  
5 V  
Trigger Level  
Resolution  
10 bits (1 in 1,024)  
Edge Trigger  
Sensitivity  
CH 0, CH 1  
TRIG (External Trigger)  
2.5% FS up to 50 MHz,  
increasing to 5% FS at  
100 MHz  
0.25 Vpk-pk up to 100 MHz,  
increasing to 1 Vpk-pk at  
200 MHz  
Level  
CH 0, CH 1  
TRIG (External Trigger)  
Accuracy,  
Typical  
3.5% FS up to 10 MHz  
0.35 V ( 3.5% FS) up to  
10 MHz  
Jitter  
80 ps rms  
Within 5 °C of  
self-calibration  
temperature.  
Trigger  
Filters  
Low-Frequency  
(LF) Reject  
High-Frequency  
(HF) Reject  
50 kHz  
50 kHz  
NI PXI/PCI-5142 Specifications  
18  
ni.com  
Specification  
Value  
Comments  
Digital Trigger (Digital Trigger Type)  
Sources  
NI PXI-5142  
NI PCI-5142  
PXI_Trig <0..6> (backplane RTSI <0..6>  
connector)  
PFI<0..1> (front panel 9-pin  
PFI<0..1> (front panel 9-pin mini-circular DIN  
mini-circular DIN  
connector)  
connector)  
PXI Star Trigger (backplane  
connector)  
Video Trigger (Video Trigger Type)  
Sources  
CH 0 (front panel BNC connector)  
CH 1 (front panel BNC connector)  
TRIG (front panel BNC connector)  
Specific Line  
Types  
Any Line  
Specific Field  
Standard  
Negative sync of NTSC, PAL, or SECAM signal  
TRIG (External Trigger, Front Panel Connector)  
Specification  
Value  
Connector  
BNC  
Impedance  
1 MΩ in parallel with 22 pF  
Coupling  
AC, DC  
12 Hz  
AC-Coupling Cutoff (–3 dB)  
Input Voltage Range  
5 V  
Maximum Input Overload  
|Peaks| 42 V  
© National Instruments Corporation  
19  
NI PXI/PCI-5142 Specifications  
PFI 0 and PFI 1 (Programmable Function Interface,  
AUX Front Panel Connectors)  
Specification  
Connector  
Value  
9-pin mini-circular DIN  
Bi-directional  
Direction  
As an Input (Trigger)  
Destinations  
Start Trigger (Acquisition Arm)  
Reference (Stop) Trigger  
Arm Reference Trigger  
Advance Trigger  
150 kΩ  
Input Impedance  
VIH  
VIL  
2.0 V  
0.8 V  
Maximum Input Overload –0.5 V, 5.5 V  
Maximum Frequency  
25 MHz  
As an Output (Event)  
Sources  
Start Trigger (Acquisition Arm)  
Reference (Stop) Trigger  
End of Record  
Done (End of Acquisition)  
Probe Compensation (1 kHz, 50% duty cycle square wave,  
PFI 1 only)  
Output Impedance  
Logic Type  
50 Ω  
3.3 V CMOS  
24 mA  
Maximum Drive Current  
Maximum Frequency  
25 MHz  
NI PXI/PCI-5142 Specifications  
20  
ni.com  
TClk Specifications  
National Instruments TClk synchronization method and the NI-TClk driver  
are used to align the sample clocks on any number of SMC-based modules  
in a chassis. For more information about TClk synchronization, refer to the  
NI-TClk Synchronization Help, which is located within the NI High-Speed  
Digitizers Help.  
Specifications are valid for any number of modules installed in one  
NI PXI-1042 chassis.  
All parameters set to identical values for each SMC-based module.  
Sample Clock set to 100 MS/s and all filters are disabled.  
For other configurations, including multichassis systems, contact  
NI Technical Support at ni.com/support.  
Note Although you can use NI-TClk to synchronize nonidentical modules, these  
specifications apply only to synchronizing identical modules.  
Specification  
Value  
Comments  
Intermodule SMC Synchronization Using NI-TClk for Identical Modules (Typical)  
Skew  
500 ps  
Caused by clock and analog  
path delay differences.  
No manual adjustment  
performed.  
Skew After Manual 5 ps  
Adjustment  
For information about  
manual adjustment, refer to  
the Synchronization  
Repeatability Optimization  
topic in the NI-TClk  
Synchronization Help.  
For additional help with the  
adjustment process, contact  
NI Technical Support at  
ni.com/support.  
Sample Clock  
Delay/Adjustment  
Resolution  
5 ps  
© National Instruments Corporation  
21  
NI PXI/PCI-5142 Specifications  
Waveform Specifications  
Specification  
Value  
Comments  
Onboard Memory Size 64 MB per Channel  
Option  
32 megasamples  
per channel*  
*Assumes 2-byte  
samples. In  
Complex data  
256 MB per Channel  
Option  
128 megasamples  
per channel*  
processing mode  
(onlyavailablewhen  
usingonboardsignal  
processing), each  
sample is 4 bytes,  
so this number is  
halved.  
Minimum Record  
Length  
1 Sample  
Number of Pretrigger  
Samples  
Zero up to full Record Length  
Zero up to full Record Length  
Single-record mode  
and multiple-record  
mode.  
Number of Posttrigger  
Samples  
Single-record mode  
and multiple-record  
mode.  
Maximum Number of  
Records in Onboard  
Memory  
64 MB/channel  
256 MB/channel  
100,000†  
100,000†  
It is possible to  
exceed these  
numbers if you fetch  
records while  
acquiring data. For  
more information,  
refer to the  
NI High-Speed  
Digitizers Help.  
Real Data  
Complex Data  
Processing Mode  
Processing Mode  
(Record Length ×  
(Record Length ×  
Allocated Onboard  
Memory per Record  
2 bytes/S) + 200 bytes, 4 bytes/S) + 200 bytes,  
rounded up to next  
rounded up to next  
multiple of 128 bytes  
multiple of 128 bytes  
or  
or  
512 bytes, whichever  
is greater  
512 bytes, whichever  
is greater  
NI PXI/PCI-5142 Specifications  
22  
ni.com  
Onboard Signal Processing (OSP)  
ADC/  
Timing  
Engine  
I Data  
Stream  
Filtering  
and  
x
Onboard  
Memory  
CH 0  
CH 1  
Digital  
Gain  
Digital  
Offset  
Eq. FIR  
Filter  
Decimation  
Complex  
Interleaver  
Filtering  
and  
Decimation  
x
Q Data  
Stream  
Digital  
Gain  
Digital  
Offset  
Data Processing  
Mode Selection  
Trigger  
Detector at  
DDC Output  
To Trigger  
Multiplexer  
Frequency  
Translation  
Filtering and  
Decimation  
Onboard Signal Processing (DDC)  
Figure 5. NI 5142 Onboard Signal Processing Block Diagram  
Note To use onboard signal processing (OSP) on the NI 5142, the DDC Enabled  
property/attribute must be set to True.  
The following four OSP operations are available:  
Send one IF signal to CH 0 and perform quadrature downconversion  
on the signal (complex data is returned).  
Send I and Q baseband signals to CH 0 and CH 1 and perform  
alias-protected decimation (complex data is returned).  
Send a signal to CH 0 and perform alias-protected decimation  
(real data is returned).  
Send a signal to CH 0 and perform real downconversion on the signal  
(real data is returned).  
© National Instruments Corporation  
23  
NI PXI/PCI-5142 Specifications  
Specification  
OSP General  
Value  
Comments  
Number of Digital  
Downconverters  
(DDCs)  
1
Data Processing  
Modes  
1. Real (I path only)  
2. Complex (IQ)  
Complex mode is used  
for both IQ baseband  
decimation and  
quadrature  
downconversion.  
OSP Decimation  
Range  
1, 2, 4, 6, 8, 10  
OSP decimation protects  
acquired data from  
12 to 4,096 (Multiples of 4)  
4,096 to 8,192 (Multiples of 8)  
8,192 to 16,384 (Multiples of 16)  
high-frequency aliasing  
within the ADC Nyquist  
zone, whereas non-OSP  
decimation does not.  
Non-OSP decimation  
and OSP decimation are  
mutually exclusive (that  
is, they cannot be used at  
the same time).  
Internal Sample  
Clock Timebase  
External Sample  
Clock Timebase  
For sample rates less  
than 6.1 kS/s, use an  
external sample clock or  
perform additional  
Sample Rate Range  
Bandwidth  
6.1 kS/s – 100 MS/s Sample Clock  
(Real or Complex)  
Timebase/OSP  
Decimation  
software decimation.  
Real Flat Bandwidth  
= 0.4 × Sample Rate  
Example: Complex  
bandwidth is 40 MHz  
with a Complex Sample  
Rate of 50 MS/s.  
Complex Flat Bandwidth  
= 0.8 × Sample Rate  
Digital Gain and Offset  
Digital Gain and  
Offset Resolution  
18 bits  
Digital Gain Range  
–1.5 to +1.5  
| Values | <1 attenuate user data  
Digital Offset Range  
(–0.4 × Vertical Range) to  
(+0.4 × Vertical Range)  
Applied after Digital  
Gain  
NI PXI/PCI-5142 Specifications  
24  
ni.com  
Specification  
Output  
Value  
Comments  
(ADC Data × Digital Gain) + Digital Offset  
(–0.5 × Vertical Range)  
Output ≤  
(+0.5 × Vertical Range)  
Numerically-Controlled Oscillator (NCO)  
Internal Sample  
Clock Timebase  
External Sample  
Clock Timebase  
Undersampling can be  
used for carrier  
frequencies >50 MHz.  
0 – 50 MHz  
0 Hz to  
Frequency Range  
(0.5 × Sample  
Clock Timebase)  
Frequency Resolution 355 nHz  
Sample Clock  
Timebase / 248  
I and Q Phase  
Resolution  
0.0055 º  
1 ms  
Tuning Time  
Digital Performance  
Maximum NCO Spur  
<–100 dBFS  
<0.1 dB  
Decimating Filter  
Passband Ripple  
Passband is from 0 to  
(0.4 × IQ Rate).  
Decimating Filter  
Out of Band  
Suppression  
>80 dB  
Stopband suppression  
from (0.6 × IQ Rate).  
© National Instruments Corporation  
25  
NI PXI/PCI-5142 Specifications  
Specification  
Value  
Comments  
IF Demodulation Performance (Typical)  
Modulation  
Configuration  
Measurement Type  
Value  
62 dB  
GSM Physical  
Layer 1, 2, 8  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
<0.2% rms  
52 dB  
W-CDMA Physical Modulation Error Ratio (MER)  
Layer 1, 3, 8  
Error Vector Magnitude (EVM)  
<0.4% rms  
48 dB  
DVB Physical  
Layer 1, 4, 8  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
<0.4% rms  
39 dB  
20 MSymbols/s,  
64 QAM 1, 5, 8  
<0.8% rms  
36 dB  
26.09 MSymbols/s, Modulation Error Ratio (MER)  
64 QAM1, 6, 8  
30 MHz bandwidth  
40 MHz bandwidth  
Error Vector Magnitude (EVM)  
<1.0% rms  
32 dB  
34.78 MSymbols/s  
64 QAM 1, 7, 8  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
<1.6% rms  
1 Vertical Range = 1 (Vpk-pk), Input Impedance = 50 Ω, no analog filter, 25 MHz carrier  
2 Sample Rate = 1.25 MS/s, MSK modulation, 270.833 kSymbols/s, Gaussian, BT = 0.3  
3 Sample Rate = 6.25 MS/s, QPSK modulation, 3.84 MSymbols/s, root raised cosine, alpha = 0.22  
4 Sample Rate = 10 MS/s, 32 QAM modulation, 6.92 MSymbols/s, root raised cosine, alpha = 0.15  
5 Sample Rate = 50 MS/s, 64 QAM modulation, 20 MSymbols/s, root raised cosine, alpha = 0.15  
6 Sample Rate = 50 MS/s, 64 QAM Modulation, 26.09 MSymbols/s. root raised cosine, alpha = 0.15  
7 Sample Rate = 50 MS/s, 64 QAM Modulation, 34.78 MSymbols/s. root raised cosine, alpha = 0.15  
8 Demodulation, including resampling (sample rate conversion) and pulse shaping, was done with the NI Modulation Toolkit  
in the host PC/controller.  
NI PXI/PCI-5142 Specifications  
26  
ni.com  
Specification  
Value  
Comments  
IQ Baseband Demodulation Performance (Typical)  
Modulation  
Configuration  
Measurement Type  
Value  
41 dB  
GSM  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
Modulation Error Ratio (MER)  
Error Vector Magnitude (EVM)  
Physical Layer 1, 2, 6, 7  
<0.8% rms  
41 dB  
W-CDMA  
Physical Layer 1, 3, 6, 7  
<0.9% rms  
40 dB  
DVB  
Physical Layer 1, 4, 6, 7  
<0.9% rms  
33 dB  
20 MSymbols/s  
64 QAM 1, 5, 6, 7  
<1.4% rms  
1 Vertical Range = 1 (Vpk-pk), Input Impedance = 50 Ω, no analog filter  
2 Sample Rate = 1.25 MS/s, MSK modulation, 270.833 kSymbols/s, Gaussian, BT = 0.3  
3 Sample Rate = 6.25 MS/s, QPSK modulation, 3.84 MSymbols/s, root raised cosine, alpha = 0.22  
4 Sample Rate = 10 MS/s, 32 QAM modulation, 6.92 MSymbols/s, root raised cosine, alpha = 0.15  
5 Sample Rate = 50 MS/s, 64 QAM modulation, 20 MSymbols/s, root raised cosine, alpha = 0.15  
6 Demodulation, including resampling (sample rate conversion) and pulse shaping, done with the NI Modulation Toolkit in  
the host PC/controller.  
7 This is a measurement of system performance. The IQ Baseband generation was implemented with two TClk synchronized  
NI PXI-5421 arbitrary waveform generators.  
Specification  
Value  
Comments  
Waveform Acquisition Times  
Maximum Acquisition Time  
64 ΜΒ  
0.336 s  
256 ΜΒ  
For Complex  
(IQ) mode, the  
acquisition time  
is halved.  
Sample Rate = 100 MS/s,  
OSP Disabled  
1.34 s  
Sample Rate = 1 MS/s,  
33.6 s  
2 min, 14 s  
Real Mode, OSP Enabled  
Sample Rate = 100 kS/s,  
Real Mode, OSP Enabled  
5 min, 36 s  
22 min, 22 s  
© National Instruments Corporation  
27  
NI PXI/PCI-5142 Specifications  
10  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
0
10  
20  
30  
40  
50  
Frequency (MHz)  
Figure 6. Decimation Filter Frequency Response (Real Mode),  
Sample Rate = 10 MS/s  
NI PXI/PCI-5142 Specifications  
28  
ni.com  
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–120  
27.5  
22.5 23  
24  
25  
26  
27  
Frequency (MHz )  
Figure 7. GSM Physical Layer 1, 2  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–125  
10  
15  
20  
25  
30  
35  
40  
Frequency (MHz )  
Figure 8. W-CDMA Physical Layer 1, 3  
1 Vertical Range = 1 (Vpk-pk), input impedance = 50 Ω, no analog filter, 25 MHz carrier  
2 Sample Rate = 4.17 MS/s, MSK modulation, 270.833 kSymbols/s, Gaussian, BT = 0.3  
3 Sample Rate = 25 MS/s, QPSK modulation, 3.84 MSymbols/s, root raised cosine, alpha = 0.22  
4 Sample Rate = 25 MS/s, 32 QAM modulation, 6.92 MSymbols/s, root raised cosine, alpha = 0.15  
5 Sample Rate = 50 MS/s, 64 QAM modulation, 20 MSymbols/s, root raised cosine, alpha = 0.15  
© National Instruments Corporation  
29  
NI PXI/PCI-5142 Specifications  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–115  
10  
15  
20  
25  
30  
35  
40  
Frequency (MHz )  
Figure 9. DVB Physical Layer 1, 4  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
Frequency (MHz)  
Figure 10. 20 MSymbols/s 64 QAM 1, 5  
1 Vertical Range = 1 (Vpk-pk), input impedance = 50 Ω, no analog filter, 25 MHz carrier  
2 Sample Rate = 4.17 MS/s, MSK modulation, 270.833 kSymbols/s, Gaussian, BT = 0.3  
3 Sample Rate = 25 MS/s, QPSK modulation, 3.84 MSymbols/s, root raised cosine, alpha = 0.22  
4 Sample Rate = 25 MS/s, 32 QAM modulation, 6.92 MSymbols/s, root raised cosine, alpha = 0.15  
5 Sample Rate = 50 MS/s, 64 QAM modulation, 20 MSymbols/s, root raised cosine, alpha = 0.15  
NI PXI/PCI-5142 Specifications  
30  
ni.com  
Calibration  
Specification  
Value  
Self-Calibration  
Self-calibration is done on software command. The calibration  
corrects for gain, offset, frequency response, triggering, and timing  
adjustment errors for all input ranges.  
External Calibration  
(Factory Calibration)  
The external calibration calibrates the VCXO and the voltage  
reference. Appropriate constants are stored in nonvolatile memory.  
Interval for External  
Calibration  
2 years  
Warm-Up Time  
15 minutes  
Power  
Specification  
Typical Value  
NI PXI-5142  
1.0 A  
NI PCI-5142  
3.4 A  
+3.3 VDC  
+5 VDC  
1.7 A  
2.7 A  
+12 VDC  
–12 VDC  
Total Power  
800 mA  
270 mA  
24.7 W  
110 mA  
0 A  
26.1 W  
© National Instruments Corporation  
31  
NI PXI/PCI-5142 Specifications  
Software  
Specification  
Value  
Driver Software  
NI-SCOPE 3.0 or later.  
NI-SCOPE is an IVI-compliant driver that allows you to configure, control,  
and calibrate the NI 5142. NI-SCOPE provides application programming  
interfaces for many development environments.  
Application  
Software  
NI-SCOPE provides programming interfaces, documentation, and examples  
for the following application development environments:  
LabVIEW  
LabWindows/CVI™  
Measurement Studio  
Microsoft Visual C/C++  
Microsoft Visual Basic  
Interactive Soft  
Front Panel and  
Configuration  
The Scope Soft Front Panel 2.4 or later supports interactive control of the  
NI 5142. The Scope Soft Front Panel is included on the NI-SCOPE CD.  
National Instruments Measurement & Automation Explorer (MAX) also  
provides interactive configuration and test tools for the NI 5142. MAX is  
included on the NI-SCOPE CD.  
Environment  
NI PXI-5142  
Note To ensure that the NI PXI-5142 cools effectively, follow the guidelines in  
the Maintain Forced Air Cooling Note to Users included in the NI PXI-5142 kit.  
The NI PXI-5142 is intended for indoor use only.  
Specification  
Value  
Comments  
Operating  
Temperature  
0 ºC to +55 ºC in all NI PXI chassis except the following:  
0 ºC to +45 ºC when installed in an NI PXI-1000/B or  
PXI-101x chassis.  
Meets IEC-60068-2-1 and IEC-60068-2-2.  
Storage  
Temperature  
–40 ºC to +71 ºC. Meets IEC-60068-2-1 and  
IEC-60068-2-2.  
NI PXI/PCI-5142 Specifications  
32  
ni.com  
Specification  
Value  
Comments  
Operating Relative  
Humidity  
10% to 90%, noncondensing. Meets IEC-60068-2-56.  
Storage Relative  
Humidity  
5% to 95%, noncondensing. Meets IEC-60068-2-56.  
Operating Shock  
30 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test  
profile developed in accordance with MIL-PRF-28800F.  
Storage Shock  
50 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test  
profile developed in accordance with MIL-PRF-28800F.  
Operating Vibration 5 Hz to 500 Hz, 0.31 grms. Meets IEC-60068-2-64.  
Storage  
5 Hz to 500 Hz, 2.46 grms. Meets IEC-60068-2-64.  
Test profile exceeds requirements of MIL-PRF-28800F,  
Class B.  
Vibration  
Altitude  
2,000 m maximum (at 25 °C ambient temperature)  
2
Pollution Degree  
NI PCI-5142  
Note To ensure that the NI PCI-5142 cools effectively, make sure that the chassis in which  
it is used has active cooling that provides at least some airflow across the PCI card cage.  
To maximize airflow and extend the life of the device, leave any adjacent PCI slots empty.  
Refer to the Maintain Forced Air Cooling Note to Users included in the NI PCI-5142 kit  
for important cooling information. The NI PCI-5142 is intended for indoor use only.  
Specification  
Operating  
Value  
Comments  
0 ºC to +45 ºC. Meets IEC-60068-2-1 and IEC-60068-2-2.  
Temperature  
Storage  
Temperature  
–40 ºC to +71 ºC. Meets IEC-60068-2-1 and  
IEC-60068-2-2.  
Operating Relative  
Humidity  
10% to 90%, noncondensing. Meets IEC-60068-2-56.  
Storage Relative  
Humidity  
5% to 95%, noncondensing. Meets IEC-60068-2-56.  
Storage Shock  
50 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test  
profile developed in accordance with MIL-PRF-28800F.  
© National Instruments Corporation  
33  
NI PXI/PCI-5142 Specifications  
Specification  
Storage  
Value  
Comments  
5 Hz to 500 Hz, 2.46 grms. Meets IEC-60068-2-64.  
Test profile exceeds requirements of MIL-PRF-28800F,  
Class B.  
Vibration  
Altitude  
2,000 m maximum (at 25 °C ambient temperature)  
2
Pollution Degree  
Safety, Electromagnetic Compatibility,  
and CE Compliance  
Safety  
This product is designed to meet the requirements of the following  
standards of safety for electrical equipment for measurement, control,  
and laboratory use:  
IEC 61010-1, EN 61010-1  
UL 61010-1, CSA 61010-1  
Note For UL and other safety certifications, refer to the product label or visit ni.com/  
certification, search by model number or product line, and click the appropriate link  
in the Certification column.  
Electromagnetic Compatibility  
This product is designed to meet the requirements of the following  
standards of EMC for electrical equipment for measurement, control,  
and laboratory use:  
EN 61326 EMC requirements; Minimum Immunity  
EN 55011 Emissions; Group 1, Class A  
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A  
Note For EMC compliance, operate this device with RG223/U or equivalent shielded  
cable. Operate according to product documentation  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives, as amended for CE marking, as follows:  
2006/95/EC; Low-Voltage Directive (safety)  
2004/108/EC; Electromagnetic Compatibility Directive (EMC)  
NI PXI/PCI-5142 Specifications  
34  
ni.com  
Note Refer to the Declaration of Conformity (DoC) for this product for any additional  
regulatory compliance information. To obtain the DoC for this product, visit ni.com/  
certification, search by model number or product line, and click the appropriate link  
in the Certification column.  
Environmental Management  
National Instruments is committed to designing and manufacturing  
products in an environmentally responsible manner. NI recognizes that  
eliminating certain hazardous substances from our products is beneficial  
not only to the environment but also to NI customers.  
For additional environmental information, refer to the NI and the  
Environment Web page at ni.com/environment. This page contains the  
environmental regulations and directives with which NI complies, as well  
as any other environmental information not included in this document.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling  
center. For more information about WEEE recycling centers and National Instruments  
WEEE initiatives, visit ni.com/environment/weee.htm.  
⬉ᄤֵᙃѻક∵ᶧ᥻
ㅵ⧚
⊩ ˄Ё೑  
˅
RoHS  
Ё೑ᅶ᠋  
݇Ѣ  
ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤
Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ  
DŽ
National Instruments  
National Instruments  
(RoHS)  
Ё೑  
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ  
RoHS  
ni.com/environment/rohs_china  
(For information about China RoHS compliance, go to  
.)  
Physical  
Front Panel Connectors  
Label  
CH 0  
Function  
Connector Type  
Analog Input  
Analog Input  
External Trigger  
BNC female  
BNC female  
BNC female  
SMB jack  
CH 1  
TRIG  
CLK IN  
Sample Clock Input and  
Reference Clock Input  
CLK OUT  
Sample Clock Output and  
Reference Clock Output  
SMB jack  
© National Instruments Corporation  
35  
NI PXI/PCI-5142 Specifications  
AUX I/O  
PFI 0, PFI 1  
9-pin mini-circular DIN  
NI PXI-5142 Front Panel Indicators  
Label  
Function  
For more  
information,  
refer to the  
NI High-Speed  
Digitizers Help.  
ACCESS  
The ACCESS LED indicates the status of the PCI bus and  
the interface from the NI PXI-5142 to the controller.  
ACTIVE  
The ACTIVE LED indicates the status of the onboard  
acquisition hardware of the NI PXI-5142.  
Dimensions and Weight  
NI PXI-5142  
Dimensions  
3U, One slot, PXI/cPCI Module  
21.6 × 2.0 × 13.0 cm  
(8.5 × 0.8 × 5.1 in.)  
2.0 cm  
(0.8 in.)  
13.0 cm  
(5.1 in.)  
21.6 cm  
(8.5 in.)  
Weight  
459 g (16.2 oz)  
NI PXI/PCI-5142 Specifications  
36  
ni.com  
NI PCI-5142  
Dimensions  
35.5 × 2.0 × 11.3 cm  
(14.0 × 0.8 × 4.4 in.)  
2.0 cm  
(0.8 in.)  
11.3 cm  
(4.4 in.)  
35.5 cm  
(14.0 in.)  
Weight  
470 g (16.6 oz)  
© National Instruments Corporation  
37  
NI PXI/PCI-5142 Specifications  
Where to Go for Support  
The National Instruments Web site is your complete resource for technical  
support. At ni.com/support you have access to everything from  
troubleshooting and application development self-help resources to email  
and phone assistance from NI Application Engineers.  
A Declaration of Conformity (DoC) is our claim of compliance with the  
Council of the European Communities using the manufacturer’s  
declaration of conformity. This system affords the user protection for  
electronic compatibility (EMC) and product safety. You can obtain the DoC  
for your product by visiting ni.com/certification. If your product  
supports calibration, you can obtain the calibration certificate for your  
product at ni.com/calibration.  
National Instruments corporate headquarters is located at  
11500 North Mopac Expressway, Austin, Texas, 78759-3504.  
National Instruments also has offices located around the world to help  
address your support needs. For telephone support in the United States,  
create your service request at ni.com/support and follow the calling  
instructions or dial 512 795 8248. For telephone support outside the United  
States, contact your local branch office:  
Australia 1800 300 800, Austria 43 662 457990-0,  
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,  
Canada 800 433 3488, China 86 21 5050 9800,  
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,  
Finland 358 (0) 9 725 72511, France 01 57 66 24 24,  
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,  
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400,  
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710,  
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,  
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60,  
Poland 48 22 3390150,Portugal 351 210 311 210,Russia 7 495 783 6851,  
Singapore 1800 226 5886, Slovenia 386 3 425 42 00,  
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,  
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,  
Taiwan 886 02 2377 2222, Thailand 662 278 6777,  
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545  
NI PXI/PCI-5142 Specifications  
38  
ni.com  
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on  
ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are  
trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location:  
Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents.  
© 2006–2007 National Instruments Corporation. All rights reserved.  
374300C  
Oct07  
仕様  
オンボード信号処理機能付きデジタイザ  
NI PXI/PCI-5142  
ビット  
14  
100 MS/s  
このドキュメントは、  
)高速デジタイザの仕様  
NI PXI/PCI-5142 NI 5142  
を記載しますに注記のない限り、各仕様において以下の条件が適用さ  
れます。  
すべてのフィルタ設定  
すべてのインピーダンス選択  
サンプルクロックは  
に設定  
100 MS/s  
標準値は、 ~  
15 35  
℃の周辺温度で測定される平均単位です。仕様は事  
前の通知なしに変更されることがあります新の  
の仕様につい  
NI 5142  
ては、ni.com/manuals を参照してください。  
のドキュメントにアクセスするには、スタート→すべてのプログ  
NI 5142  
ラム→  
→ドキュメントを選択しま  
National Instruments NI-SCOPE  
す。  
熱面  
を長時間使用する場合、デバイスまたはシールドは安全な取扱温度を超  
NI 5142  
え、火傷の原因になる場合がありますールドに触れる、もしくはデバイスを  
シャーシまたは から取り外す前に、 を十分に冷却してください。  
PC  
NI 5142  
動作温度については「環境」のセクションを参照してください。  
目次  
垂直軸  
.................................................................................................................................2  
アナログ入力(チャンネル およびチャンネル  
0
1 ..................................2  
水平軸  
...............................................................................................................................13  
サンプルクロック  
................................................................................................13  
位相ロックループ(  
)基準クロック  
PLL  
(サンプルクロックおよび基準クロック入力、  
.....................................................15  
CLK IN  
フロントパネルコネクタ)  
.............................................................................16  
(サンプルクロックおよび基準クロック出力、  
CLK OUT  
フロントパネルコネクタ)  
.............................................................................16  
トリガ  
...............................................................................................................................16  
基準(停止)トリガ  
...........................................................................................16  
(外部トリガ、フロントパネルコネクタ)  
TRIG  
........................................18  
および  
(プログラム可能な関数インタフェース、  
PFI 0  
PFI 1  
フロントパネルコネクタ)  
AUX  
........................................................................... 19  
仕様  
TClk  
波形仕様  
......................................................................................................................... 20  
.......................................................................................................................... 21  
オンボード信号処理(  
キャリブレーション  
OSP .................................................................................... 22  
.................................................................................................... 30  
電源  
................................................................................................................................... 30  
ソフトウェア  
環境  
................................................................................................................. 31  
................................................................................................................................... 31  
NI PXI-5142........................................................................................................... 31  
NI PCI-5142.......................................................................................................... 32  
安全性、電磁両立性、  
適合  
CE  
............................................................................... 33  
安全性  
..................................................................................................................... 33  
電磁両立性  
............................................................................................................. 33  
................................................................................................................... 33  
適合  
CE  
環境管理  
................................................................................................................. 34  
.......................................................................................................................... 34  
物理特性  
フロントパネルコネクタ  
外形寸法および重量  
.................................................................................. 34  
........................................................................................... 35  
サポート情報  
................................................................................................................. 37  
垂直軸  
アナログ入力(チャンネル およびチャンネル )  
1
0
仕様  
コメント  
チャンネル数  
(同時サンプリング)  
2
BNC  
コネクタ  
インピーダンスおよびカプリング  
入力インピーダ  
ンス  
Ω
50 ±2.0%  
Ω
1 M ±0.75%  
27 pF ±2 pF  
タンスと並列)  
ソフトウェアで  
選択可能  
のキャパシ  
入力カプリング  
カプリング  
AC DC GND  
AC  
は、  
Ω のみ  
1 M  
で有効。  
仕様  
NI PXI/PCI-5142  
2
ni.com/jp  
仕様  
コメント  
電圧レベル  
フルスケール  
Ω
Ω
50  
1 M  
–10 dBm  
+24 dBm  
)入力レン  
FS  
レンジ  
垂直オフセット  
レンジ  
垂直オフセッ  
ジおよびプログ  
ラム可能な垂直  
オフセット  
Ω モード)  
50  
レンジ( )  
トレンジ( )  
Vpk-pk  
0.2  
0.4  
1
V
Vpk-pk  
0.2  
0.4  
1
V
±0.1  
±0.2  
±0.5  
±1  
±0.1  
±0.2  
±0.5  
±1  
2
2
4
±2  
4
±2  
10  
10  
20  
±5  
最大入力過負荷  
Ω
Ω
1 M  
50  
| ピーク | ≤  
7 Vrms  
| ピーク | ≤  
42 V  
10 V  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
3
仕様  
コメント  
精度  
分解能  
ビット  
14  
精度(プロ  
グラム可能な垂  
レンジ(  
Ω および  
Ω
セルフキャリブ  
レーション実行  
DC  
Vpk-pk  
50  
1 M  
NI PXI-5142:  
0.2 0.4  
直オフセット  
時の温度  
以内  
=
±5  
(入力の  
±
0.65% + 1.0 mV  
0 V  
NI PCI-5142:  
(入力の  
±
0.65% + 2.0 mV  
1
2
NI PXI-5142:  
(入力の  
±
0.65% + 1.2 mV  
NI PCI-5142:  
(入力の  
±
0.65% + 2.0 mV  
NI PXI-5142:  
(入力の  
±
0.65% + 1.6 mV  
NI PCI-5142:  
(入力の  
±
0.65% + 2.0 mV  
NI PXI/PCI-5142:  
4 10  
(入力の  
±
0.65% + 8.0 mV  
NI PXI/PCI-5142:  
20 1 M  
Ω のみ)  
(入力の  
±
0.65% + 13.0 mV  
プログラム可能  
な垂直オフセッ  
トの精度  
オフセット設定の  
セルフキャリブ  
レーション実行  
±0.4%  
時の温度  
以内  
±5  
ドリフト  
レンジ(  
Ω および  
Ω
1 M  
DC  
Vpk-pk  
50  
、 、  
(入力の  
±
0.057% + FS 0.006% +  
0.2 0.4 1 2  
μ ) ℃  
100 V /  
1M  
(入力の  
±
0.057% + FS 0.006% +  
4 10 20  
Ω のみ)  
μ ) ℃  
900 V /  
振幅精度  
Ω
Ω
1 M  
セルフキャリブ  
レーション実行  
AC  
50  
±0.06dB ±0.7%  
±0.09dB ±1.0%  
時の温度  
以内  
±5  
時)  
時)  
50 kHz  
50 kHz  
クロストーク  
(標準)  
から  
–100 dB 10 MHz  
CH0  
および  
CH1  
CH1  
トリガから  
、外部  
CH0  
または  
CH0  
CH1  
仕様  
NI PXI/PCI-5142  
4
ni.com/jp  
仕様  
コメント  
帯域幅および過渡対応  
帯域幅  
レンジ(  
Ω および Ω  
1 M  
フィルタ無効時  
(–3 dB)  
Vpk-pk  
50  
℃以上の場  
78 MHz  
* 40  
100 MHz  
全レンジ  
を除く)  
0.2  
0.2  
(最高  
℃ )  
*
80 MHz  
40  
立ち上がり  
ち下がり時間  
(標準)  
レンジ(  
Ω および  
Ω
1 M  
/
Vpk-pk  
50  
3.5 ns  
全レンジ  
0.2  
を除く)  
0.2  
4.2 ns  
帯域幅リミット  
フィルタ  
ノイズフィルタ  
アンチエイリアスフィルタ 一度に つの  
1
フィルタのみ有  
20 MHz  
次ベッセルフィルタ  
40 MHz –6 dB  
、標準)  
効にすることが  
可能ンチエ  
イリアスフィル  
タはデフォルト  
で有効。  
) 次  
2
35 MHz –3 dB 6  
チェビシェフフィルタ  
12 Hz  
カプリング  
カプリング  
AC  
カットオフ  
AC  
は、  
Ω のみ  
1 M  
–3 dB  
で有効。  
通過帯域フラッ  
トネス  
フィルタ設定  
レンジ  
を基準  
50 kHz  
とする。  
( )  
Vpk-pk  
Ω および Ω  
1 M  
50  
フィルタ無効時  
全レンジ  
( を  
除く)  
±0.4 dB DC 20 MHz  
0.2  
±1 dB 20 MHz  
50 MHz  
0.2  
±0.4 dB DC 20 MHz  
40 MHz  
±1 dB 20 MHz  
アンチエイリアス 全レンジ  
フィルタ有効時  
±1.2 dB DC 16 MHz  
±1.6 dB 16 MHz  
32 MHz  
仕様  
© National Instruments Corporation  
5
NI PXI/PCI-5142  
1.0  
0.0  
–1.0  
–2.0  
–3.0  
–4.0  
–5.0  
–6.0  
–7.0  
–8.0  
–9.0  
–10.0  
䊐䉞䊦䉺  
ήലᤨ  
䊉䉟䉵䊐䉞䊦䉺  
᦭ലᤨ  
䉝䊮䉼䉣䉟䊥䉝䉴  
䊐䉞䊦䉺᦭ലᤨ  
1 M  
10 M  
100 M 150 M  
๟ᵄᢙ䋨Hz䋩  
周波数応答(標準)  
NI 5142  
1
仕様  
NI PXI/PCI-5142  
6
ni.com/jp  
仕様  
コメント  
スペクトル特性  
高調波を含むス  
プリアスフリー  
ダイナミックレ  
レンジ  
Ω
Ω
50  
1 M  
10 MHz  
入力  
–1 dBFS  
信号。  
Vpk-pk  
0.2  
0.4  
1
75 dBc  
75 dBc  
75 dBc  
75 dBc  
65 dBc  
65 dBc  
なし  
70 dBc  
70 dBc  
70 dBc  
70 dBc  
70 dBc  
60 dBc  
60 dBc  
ンジ(  
(標準)  
SFDR)  
高調波か  
ら第 高調波  
5
までを含む。  
2
NI PXI-5142  
2
から  
DC  
まで  
50 MHz  
を計測。  
4
10  
20  
NI PCI-5142  
から  
まで  
5 kHz  
50 MHz  
を計測。  
Ω のみ)  
1 M  
全高調波歪み  
標準)  
レンジ  
入力  
10 MHz  
–1 dBFS  
信号。  
THD  
Ω
Ω
1 M  
Vpk-pk  
0.2  
0.4  
1
50  
–75 dBc  
–75 dBc  
–75 dBc  
–73 dBc  
–63 dBc  
–63 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–68 dBc  
–58 dBc  
–58 dBc  
第 高調波か  
ら第 高調波  
2
5
までを含む。  
2
4
10  
20  
該当なし  
Ω のみ)  
1 M  
相互変調歪み  
(標準)  
0.2 2.0 Vpk-pk  
レンジ( Ω 入力)  
およ  
50  
10.2 MHz  
11.2 MHz  
トーン。  
各トーンは、  
–75 dBc  
2
–7 dBFS  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
7
仕様  
コメント  
Ω
Ω
SN  
50  
1 M  
10 MHz  
入力  
Signal-to-  
Noise Ratio  
(標準)  
–1 dBFS  
信号。  
フィ  
ルタ  
無効  
アンチエ  
イリアス  
フィルタ  
有効時  
アンチエ  
イリアス  
フィルタ  
有効時  
フィル  
タ無効  
高調波を除く。  
レンジ  
DC  
Vpk-pk  
0.2  
0.4  
1
まで  
50 MHz  
測定。  
60 dB  
62 dB  
62 dB  
62 dB  
60 dB  
62 dB  
62 dB  
62 dB  
56 dB  
61 dB  
62 dB  
62 dB  
61 dB  
60 dB  
62 dB  
62 dB  
62 dB  
62 dB  
Ω
2
4
SINAD Signal  
to Noise and  
Distortion  
(標準)  
Ω
50  
1 M  
10 MHz  
入力  
–1 dBFS  
信号。  
フィ  
ルタ  
無効  
アンチエ  
イリアス  
フィルタ  
有効時  
アンチエ  
イリアス  
フィルタ  
有効時  
フィル  
タ無効  
高調波を含む。  
レンジ  
DC  
Vpk-pk  
0.2  
0.4  
1
まで  
50 MHz  
測定。  
60 dB  
62 dB  
62 dB  
62 dB  
60 dB  
62 dB  
62 dB  
62 dB  
56 dB  
60 dB  
61 dB  
61 dB  
60 dB  
59 dB  
61 dB  
61 dB  
61 dB  
61 dB  
2
4
00  
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
10.24 MHz㪃㩷–1 dBFS ౉ജାภ  
–100  
–110  
0
5 M 10 M 15 M 20 M 25 M 30 M 35 M 40 M 45 M 50 M  
๟ᵄᢙ䋨Hz䋩  
の動特性、 Ω、  
1 Vpk-pk  
レンジ(標準)  
2
NI 5142  
8
50  
仕様  
NI PXI/PCI-5142  
ni.com/jp  
仕様  
コメント  
ノイズ  
(ノイズフィルタ  
有効時)  
レンジ  
Ω 終端を  
50  
入力に接続。  
RMS  
Vpk-pk  
Ω
Ω
50  
1 M  
0.2  
NI PXI-5142:  
NI PXI-5142:  
μ
μ
46 Vrms  
60 Vrms  
0.023% FS  
0.030% FS  
NI PCI-5142:  
NI PCI-5142:  
μ
μ
56 Vrms  
72 Vrms  
0.028% FS  
0.036% FS  
μ
μ
0.4  
1
92 Vrms  
92 Vrms  
0.023% FS  
0.023% FS  
μ
μ
230 Vrms  
230 Vrms  
0.023% FS  
0.023% FS  
μ
μ
2
460 Vrms  
460 Vrms  
0.023% FS  
0.023% FS  
μ
μ
4
920 Vrms  
920 Vrms  
0.023% FS  
0.023% FS  
10  
20  
2.3 mVrms  
(0.023% FS)  
2.3 mVrms  
(0.023% FS)  
4.6 mVrms  
(0.023% FS)  
該当なし  
Ω のみ)  
1 M  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
9
仕様  
コメント  
ノイズ(ア  
ンチエイリアス  
フィルタ有効時)  
レンジ  
Ω 終端を  
50  
入力に接続。  
RMS  
Vpk-pk  
Ω
Ω
50  
1 M  
0.2  
NI PXI-5142:  
NI PXI-5142:  
μ
μ
66 Vrms  
80 Vrms  
(0.033% FS)  
0.040% FS  
NI PCI-5142:  
NI PCI-5142:  
μ
μ
82 Vrms  
96 Vrms  
(0.041% FS)  
(0.048% FS)  
μ
μ
0.4  
1
100 Vrms  
120 Vrms  
0.025% FS  
0.030% FS  
μ
μ
250 Vrms  
(0.025% FS)  
300 Vrms  
0.030% FS  
μ
μ
2
500 Vrms  
600 Vrms  
0.025% FS  
0.030% FS  
4
1 mVrms  
1.2 mVrms  
(0.025% FS)  
(0.030% FS)  
10  
20  
2.5 mVrms  
(0.025% FS)  
3 mVrms  
(0.030% FS)  
6 mVrms  
(0.030% FS)  
該当なし  
Ω のみ)  
1 M  
仕様  
NI PXI/PCI-5142  
10  
ni.com/jp  
仕様  
コメント  
ノイズ  
(フィルタ無効  
時)  
レンジ  
Ω 終端を  
50  
入力に接続。  
RMS  
Vpk-pk  
Ω
Ω
50  
1 M  
0.2  
NI PXI-5142:  
NI PXI-5142:  
μ
μ
66 Vrms  
110 Vrms  
0.033% FS  
0.055% FS  
NI PCI-5142:  
NI PCI-5142:  
μ
μ
90 Vrms  
110 Vrms  
0.045% FS  
0.055% FS  
μ
μ
0.4  
1
100 Vrms  
160 Vrms  
0.025% FS  
0.040% FS  
μ
μ
250 Vrms  
300 Vrms  
0.025% FS  
0.030% FS  
μ
μ
2
500 Vrms  
600 Vrms  
0.025% FS  
0.030% FS  
4
1 mVrms  
1.6 mVrms  
(0.025% FS)  
(0.040% FS)  
10  
20  
2.5 mVrms  
(0.025% FS)  
3 mVrms  
(0.030% FS)  
6 mVrms  
(0.030% FS)  
該当なし  
Ω のみ)  
1 M  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
11  
60 n  
55 n  
50 n  
45 n  
40 n  
35 n  
30 n  
25 n  
20 n  
15 n  
10 n  
5 n  
1 n  
1 k  
10 k  
100 k  
1 M  
10 M  
24 M  
๟ᵄᢙ㧔Hz㧕  
レンジにおける  
スペクトルノイズ密度の表示、  
Ω 入力インピーダンス  
3
0.2 V  
NI 5142  
ノイズフィルタ有効時、  
1 M  
–145.000  
–147.500  
–150.000  
–152.500  
1.0 k  
10.0 k  
100.0 k  
๟ᵄᢙ䋨㪟㫑䋩  
レンジにおける  
1.0 M  
10.0 M  
50.0 M  
スペクトルノイズ密度の表示、  
4
0.2 V  
NI 5142  
帯域幅全域、 Ω 入力インピーダンス  
50  
仕様  
NI PXI/PCI-5142  
12  
ni.com/jp  
水平軸  
サンプルクロック  
仕様  
コメント  
NI PXI-5142  
NI PCI-5142  
ソース  
内部サンプルクロックは  
基準クロックにロック、ま  
*
内部、オンボード  
クロック(内部  
内部、オンボードクロッ  
*
たはオンボード  
分周して取得。  
から  
VCXO  
ク(内部  
VCXO  
VCXO  
*
外部、  
パネル  
(フロント  
コネクタ)  
CLK IN  
外部、  
ロントパネル  
コネクタ)  
(フ  
SMB  
CLK IN  
SMB  
外部、  
リガ(バックプレー  
ンコネクタ)  
スタート  
PXI  
オンボードクロック(内部  
VCXO  
サンプルレー  
ト範囲  
リアルタイムサンプ ランダムインターリーブ  
通常の操作モード(非  
モード)では、 で除  
*
OSP  
算する間引きは、  
n
リング(単発)  
サンプリング(  
RIS  
100 MS/s  
200 MS/s 2 GS/s  
1.526 kS/s  
以下のレートで使用されま  
す。サンプルクロックおよ  
びデシメーションの詳細に  
100 MS/s*  
の倍数)  
100 MS/s  
ついては速デジタ  
NI  
イザヘルプ』を参照してく  
ださい。  
モードの間引きで  
OSP  
は、集録されたデータはア  
ンダーサンプリングによる  
エイリアスから保護されま  
せん非  
モード、そし  
モードの間引きは互  
OSP  
OSP  
いに排他的であり、同時に  
使用することはできません。  
位相ノイズ密  
度(標準)  
<–100 dBc/Hz 100 Hz  
時)  
時)  
時)  
入力信号  
10 MHz  
<–120 dBc/Hz 1 kHz  
<–130 dBc/Hz 10 kHz  
サンプルク  
ロックジッタ  
(標準)  
変換器のアパーチャ不確定  
性、またクロック回路の  
ジッタの影響を含むリ  
ガジッタを除く。  
1 ps rms 100 Hz 100 kHz  
2 ps rms 100 Hz 1 MHz  
100 MHz  
タイムベース  
周波数  
仕様  
© National Instruments Corporation  
13  
NI PXI/PCI-5142  
仕様  
コメント  
タイムベース  
確度  
基準クロックへの  
位相ロックなし  
基準クロックへの  
位相ロックあり  
±25 ppm  
基準クロック精度と同等  
サンプルク  
ロック遅延  
範囲  
サンプルクロック周期  
±1  
10 ps  
サンプルク  
ロック遅延  
分解能  
外部サンプルクロック  
NI PXI-5142  
NI PCI-5142  
ソース  
(フロント  
コネク  
(フロントパネル  
コネクタ)  
CLK IN  
CLK IN  
パネル  
タ)  
SMB  
SMB  
スタートリガ  
(バックプレーン  
コネクタ)  
PXI  
周波数レンジ  
通常の操作モード(非  
モード)では、  
30 MHz 105 MHz CLK IN  
OSP  
スタートリガ)  
30 MHz 80 MHz PXI  
である場合、  
n
65,535  
n
による間引きで除算します。  
サンプルクロックおよび間  
引きの詳細については、  
高速デジタイザヘルプ』  
を参照してください。  
NI  
モードの間引きで  
OSP  
は、集録されたデータはア  
ンダーサンプリングによる  
エイリアスから保護されま  
せん非  
モード、そし  
モードの間引きは互  
OSP  
OSP  
いに排他的であり、同時に  
使用することはできません。  
デューティー  
サイクル許容  
範囲  
45 55%  
仕様  
NI PXI/PCI-5142  
14  
ni.com/jp  
仕様  
コメント  
サンプルクロックのエクスポート  
エクスポート  
したサンプル  
クロックの出  
力先  
出力先  
最大周波数  
間引きされたサンプルク  
*
ロックのみ  
105 MHz  
(フロントパネル  
コネクタ)  
CLK OUT  
SMB  
20 MHz  
25 MHz  
(バックプ  
*
PXI_Trig<0..6>  
レーンコネクタ)  
(フロントパネル  
DIN  
PFI<0..1>  
9
コネクタ)  
ピンミニサーキュラ  
*
RTSI<0..6>*  
20 MHz  
位相ロックループ(  
)基準クロック  
PLL  
仕様  
コメント  
NI PXI-5142  
NI PCI-5142  
ソース  
RTSI 7  
(バックプ  
PXI_CLK10  
レーンコネクタ)  
(フロントパネル  
コネクタ)  
CLK IN  
(フロントパネル  
コネクタ)  
CLK IN  
SMB  
SMB  
周波数範囲  
刻み)  
のデフォルト。  
1 MHz 20 MHz 1 MHz  
10 MHz  
基準クロック周波数は、  
PLL  
必要があります。  
まで正確である  
±50 ppm  
デューティーサイ  
クル許容範囲  
45 55%  
NI PXI-5142  
NI PCI-5142  
エクスポートされ  
た基準クロックの  
出力先  
(フロントパネ  
コネクタ)  
(フロントパネル  
CLK OUT  
CLK OUT  
コネクタ)  
SMB  
SMB  
(フロントパネ  
ピンミニサーキュラ  
コネクタ)  
(フロントパネル  
ピンミニサーキュラ  
PFI<0..1>  
PFI<0..1>  
9
コネクタ)  
9
DIN  
DIN  
RTSI <0..7>  
(バックプ  
PXI_Trig<0..7>  
レーンコネクタ)  
仕様  
© National Instruments Corporation  
15  
NI PXI/PCI-5142  
CLK IN  
(サンプルクロックおよび基準クロック入力ロントパネルコネクタ)  
仕様  
コメント  
入力電圧レンジ  
正弦波  
方形波  
: 0.65 Vpk-pk 2.8 Vpk-pk  
: 0.2 Vpk-pk 2.8 Vpk-pk  
0
13 dBm  
最大入力過負荷  
| ピーク | ≤  
過電圧および逆極  
性に対する保護。  
7 Vrms  
10 V  
インピーダンス  
カプリング  
Ω
50  
AC  
CLK OUT  
(サンプルクロックおよび基準クロック出力ロントパネルコネクタ)  
仕様  
コメント  
出力インピーダンス  
論理タイプ  
Ω
50  
3.3 V CMOS  
±48 mA  
最大駆動電流  
トリガ  
基準(停止)トリガꢀ  
仕様  
コメント  
トリガタイプ  
およびソース  
タイプ  
ソース  
各トリガタイプで  
使用できるソース  
の詳細について  
は、以下のセク  
ションおよび  
エッジ、ウィンドウ、ヒス  
テリシス、ビデオ、デジタ  
ル、即時、およびソフト  
ウェア  
CH 0 CH 1 TRIG  
PXI_Trig <0..6> PFI <0..1>  
スタートリガ、ソフト  
RTSI <0..6>  
PXI  
ウェア、  
高速デジタイ  
NI  
ザヘルプ』を参照  
してください。  
TDC  
オンボード  
クロック  
時間 デジ  
TDC =  
/
タル変換回路  
外部クロック  
該当なし  
時間分解能  
ON  
100 ps  
10 ns  
OFF  
外部クロック周期  
仕様  
NI PXI/PCI-5142  
16  
ni.com/jp  
仕様  
コメント  
TDC  
ON  
リアーム時間  
ホールドオフは  
に設定  
0
μ
10 s  
リアーム時間  
μ
2 s  
OFF  
TDC  
オンボード  
クロック  
外部クロック  
ON  
μ ~  
10 s 171.79 s  
該当なし  
ホールドオフ  
OFF  
μ ~  
2 s 171.79 s  
×(外部クロック周期)  
(2 – 1)  
200  
32  
×(外部クロッ  
ク周期)  
アナログトリガ(エッジ、ウィンドウ、ヒステリシストリガタイプ)  
ソース  
(フロントパネル  
(フロントパネル  
コネクタ)  
コネクタ)  
コネクタ)  
CH 0  
CH 1  
BNC  
BNC  
BNC  
(フロントパネル  
TRIG  
トリガレベル  
範囲  
CH 0 CH 1  
(外部トリガ)  
TRIG  
100% FS  
±5 V  
トリガレベル  
分解能  
ビット(  
分の  
10  
1,024  
1
エッジトリガ  
感度  
CH0 CH1  
(外部トリガ)  
(最大 )  
TRIG  
(最大  
)~  
2.5% FS  
50 MHz  
0.25 Vpk-pk  
100 MHz  
時)  
時)  
5% FS 100 MHz  
1 Vpk-pk 200 MHz  
レベル精度  
標準)  
CH0 CH1  
(外部トリガ)  
TRIG  
(
(最大  
±0.35 V ±3.5% FS  
±3.5% FS  
10 MHz  
(最大  
10 MHz  
80 ps rms  
ジッタ  
セルフキャリブ  
レーション実行時  
の温度  
℃以内。  
±5  
トリガフィル  
低周波数( )除去  
LF  
高周波数( )除去  
HF  
50 kHz  
50 kHz  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
17  
仕様  
コメント  
デジタルトリガ(デジタルトリガタイプ)  
NI PXI-5142  
NI PCI-5142  
RTSI <0..6>  
ソース  
(バックプ  
PXI_Trig <0..6>  
レーンコネクタ)  
(フロントパネル  
DIN  
PFI<0..1>  
9
(フロントパネル  
DIN  
ピンミニサーキュラ  
コネクタ)  
PFI<0..1>  
ピンミニサーキュラ  
コネクタ)  
9
スタートリガ(バック  
PXI  
プレーンコネクタ)  
ビデオトリガ(ビデオトリガタイプ)  
ソース  
タイプ  
(フロントパネル  
(フロントパネル  
コネクタ)  
コネクタ)  
コネクタ)  
CH 0  
CH 1  
BNC  
BNC  
BNC  
(フロントパネル  
TRIG  
特定のライン  
すべてのライン  
特定のフィールド  
標準  
の負同期、  
、または  
信号  
NTSC  
PAL  
SECAM  
(外部トリガ、フロントパネルコネクタ)  
TRIG  
仕様  
BNC  
Ω(  
コネクタ  
インピーダンス  
カプリング  
と並列)  
1 M  
22 pF  
AC DC  
12 Hz  
カプリングカットオフ  
AC  
–3 dB  
±5 V  
入力電圧範囲  
最大入力過負荷  
| ピーク | ≤  
42 V  
仕様  
NI PXI/PCI-5142  
18  
ni.com/jp  
および  
(プログラム可能な関数インタフェー  
PFI 0  
PFI 1  
ス、  
フロントパネルコネクタ)  
AUX  
仕様  
コネクタ  
方向  
ピンミニサーキュラ  
9
DIN  
双方向  
入力の場合(トリガ)  
出力先  
開始トリガ(集録アーム)  
基準(停止)トリガꢀ  
アーム基準トリガ  
切り替えトリガ  
入力インピーダンス  
Ω
150 k  
2.0 V  
0.8 V  
VIH  
VIL  
最大入力過負荷  
–0.5 5.5 V  
25 MHz  
最大周波数  
出力の場合(イベント)  
ソース  
開始トリガ(集録アーム)  
基準(停止)トリガꢀ  
レコードの最後  
終了(集録の最後)  
プローブ補償(  
のみ)  
1 kHz 50%  
デューティーサイクル方形波、  
PFI 1  
出力インピーダンス  
論理タイプ  
Ω
50  
3.3 V CMOS  
±24 mA  
最大駆動電流  
25 MHz  
最大周波数  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
19  
仕様  
TClk  
ナショナルインスツルメンツの  
同期方法および  
ドライバは、  
TClk  
NI-TClk  
対応モジュールのサンプルクロックを揃えるために使  
シャーシ内の  
用されます。  
SMC  
同期の詳細については速デジタイザヘルプ』の  
NI  
同期ヘルプ』を参照してください。  
TClk  
NI-TClk  
中にある『  
仕様は、 台の  
シャーシに取り付けられている任意の数  
1
NI PXI-1042  
のモジュールに対して有効です。  
対応モジュールでは、すべてのパラメータが同じ値に設定さ  
SMC  
れています。  
サンプルクロックは  
されています。  
、またすべてのフィルタは無効に設定  
100 MS/s  
マルチシャーシシステムを含むその他の構成については、ナショナル  
インスツルメンツの技術サポート(ni.com/jp/support)までお問  
い合わせください。  
メモ  
を使用して異なるモジュールを同期できますが、これらの仕様は同一の  
NI-TClk  
モジュールを使用した場合にのみ適用されます。  
仕様  
を使用したモジュール間の  
コメント  
同期(同一モジュールを使用、標準)  
NI-TClk  
SMC  
500 ps  
スキュー  
クロックおよびアナログパ  
スでの遅延の差による動  
による調整は未実施。  
5 ps  
手動での調整後の  
スキュー  
手動による調整の詳細につ  
同期ヘル  
いては『  
NI-TClk  
プ』の「同期による再現性  
の最適化」トピックを参照  
してください調整処理に関  
するその他の情報について  
は、ナショナルインスツル  
メンツの技術サポート  
ni.com/jp/support)ま  
でお問い合わせください。  
5 ps  
サンプルクロック  
遅延 調整分解能  
/
仕様  
NI PXI/PCI-5142  
20  
ni.com/jp  
波形仕様  
仕様  
コメント  
オンボードメモリ  
サイズ  
チャンネルあたり  
64 MB  
チャンネル  
バイトサンプル  
であると仮定素  
数データ処理モード  
使用時にのみ  
OSP  
可)では、各サンプ  
32 MS/  
*
*2  
(オプション)  
チャンネルあたり  
(オプション)  
256 MB  
チャンネル  
*
128 MS/  
ルは バイトとなる  
4
ため、各メモリサイ  
ズの値は半分となり  
ます。  
最短レコード長  
サンプル  
1
プレトリガサンプル数  
ゼロから最大レコード長まで  
ゼロから最大レコード長まで  
チャンネル  
シングルレコード  
モードおよびマルチ  
プルレコードモー  
ド。  
ポストトリガサンプル  
シングルレコード  
モードおよびマルチ  
プルレコードモー  
ド。  
オンボードメモリの最  
大レコード数  
データ集録中にレ  
コードをフェッチす  
る場合、これらの数  
値を上回る可能性あ  
細について  
64 MB/  
100,000  
チャンネル  
256 MB/  
100,000  
速デジタ  
NI  
イザヘルプ』を参照  
してください。  
レコードにつき割り当  
てられたオンボードメ  
モリ  
実数データ処理モード 複素データ処理モード  
(レコード長 × バイ (レコード長 × バイ  
2
バイト、  
バイトの次の倍数  
4
バイト、  
バイトの次の倍数  
/S + 200  
/S + 200  
128  
に丸め込み  
128  
に丸め込み  
または  
または  
バイトのいずれか  
512  
大きい方  
バイトのいずれか  
512  
大きい方  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
21  
オンボード信号処理(  
OSP  
ADC/  
䉺䉟䊚䊮䉫  
䉣䊮䉳䊮  
䇭㪠䊂䊷䉺  
䉴䊃䊥䊷  
䊐䉞䊦䉺ಣℂ  
䈍䉋䈶  
㑆ᒁ䈐  
x
䉥䊮䊗䊷䊄  
䇭䊜䊝䊥  
CH 0  
䊂䉳䉺䊦  
䊂䉳䉺䊦  
䉭䉟䊮  
╬ଔFIR  
䊐䉞䊦䉺  
䇭䇭ⶄ⚛  
䉟䊮䉺䊥䊷䊋  
䉥䊐䉶䉾䊃  
䊐䉞䊦䉺ಣℂ  
䈍䉋䈶  
㑆ᒁ䈐  
x
Q䊂䊷䉺  
䉴䊃䊥䊷䊛  
CH 1  
䊂䉳䉺䊦  
䉭䉟䊮  
䊂䉳䉺䊦  
䉥䊐䉶䉾䊃  
䊂䊷䉺ಣℂ䊝䊷䊄ㆬᛯ  
DCC಴ജ  
䈮䈍䈔䉎  
䊃䊥䉧ᬌ಴  
䊃䊥䉧  
䊙䊦䉼䊒䊧䉪䉰䈻  
๟ᵄᢙᄌ឵  
䊐䉞䊦䉺ಣℂ  
䈍䉋䈶㑆ᒁ䈐  
䉥䊮䊗䊷䊄ାภಣℂ䋨DDC䋩  
オンボード信号処理ブロックダイアグラム  
NI 5142  
5
メモ  
でオンボード信号処理(  
)を使用するには、  
プロパ  
NI 5142  
OSP  
に設定されている必要があります。  
DDC Enabled  
ティ 属性が  
/
TRUE  
以下の つの  
4
信号を  
操作が利用できます。  
OSP  
に送信し、信号に対して直交ダウンコンバージョンを  
CH 0  
実行します(複素データが返されます。  
IF  
および ベースバンド信号を および  
に送信し、エイリ  
I
Q
CH 0  
アス保護の状態で間引きを行います(複素データが返されます。  
CH 1  
信号を に送信し、エイリアス保護の状態で間引きを行います  
CH 0  
(実数データが返されます。  
信号を に送信し、信号に対して実数ダウンコンバージョンを行  
CH 0  
います(複素データが返されます。  
仕様  
NI PXI/PCI-5142  
22  
ni.com/jp  
仕様  
一般  
コメント  
OSP  
1
デジタルダウンコン  
バータ数(  
DDC  
データ処理モード  
実数( パスのみ)  
I
複素数(  
複素モードは、 ベー  
1.  
2.  
IQ  
スバンドにおける間引き  
および直角ダウンコン  
バージョンの両方に使用  
されます。  
IQ  
デシメーション  
、 、 、 、 、  
1 2 4 6 8 10  
による間引きは  
のナイキストゾー  
ンで起こる高周波による  
エイリアスからデータを  
OSP  
範囲  
OSP  
の倍数)  
12 4,096 4  
ADC  
の倍数)  
4,096 8,192 8  
の倍数)  
8,192 16,384 16  
保護します非  
モード、そして  
OSP  
OSP  
モードの間引きは互いに  
排他的であり、同時に使  
用することはできませ  
ん。  
サンプルレート範囲  
内部サンプルクロッ  
クタイムベース  
外部サンプルクロッ  
未満のサンプル  
6.1 kS/s  
レートには、外部サンプ  
ルクロックを使用、もし  
くはソフトウェア上で間  
引きを行ってください。  
クタイムベース  
サンプルクロックタ  
6.1 kS/s 100 MS/s  
(実数または複素数) イムベース  
シメーション  
/OSP  
帯域幅  
実領域での平坦帯域幅  
× サンプルレート  
例 複素領域でのサンプ  
:
ルレートが  
場合、複素領域における  
= 0.4  
50 MS/s  
複素領域での平坦帯域幅  
× サンプルレート  
帯域幅は  
です。  
40 MHz  
= 0.8  
デジタルゲインおよびオフセット  
デジタルゲインおよび  
オフセット分解能  
ビット  
18  
デジタルゲイン範囲  
–1.5 +1.5  
| |  
減衰ユーザデータ  
<1  
デジタルオフセット  
範囲  
× 垂直範囲)~  
× 垂直範囲)  
デジタルゲイン後に適用  
(–0.4  
+0.4  
出力  
データ × デジタルゲイン) デジタル  
× 垂直範囲)  
(–0.5  
ADC  
オフセット  
+
出力 ≤  
× 垂直範囲)  
+0.5  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
23  
仕様  
数値制御発振器(  
周波数範囲  
コメント  
NCO  
内部サンプルクロッ  
クタイムベース  
外部サンプルクロッ アンダーサンプリングは  
キャリア周波数  
>50 MHz  
可能。  
クタイムベース  
× サンプ  
0 Hz (0.5  
の場合で使用  
0
50 MHz  
ルクロックタイム  
ベース)  
355 nHz  
周波数分解能  
サンプルクロックタ  
48  
イムベース  
/2  
および 位相分解能  
Q
°
I
0.0055  
1 ms  
調整時間  
デジタル特性  
<–100 dBFS  
<0.1 dB  
最大  
刺激  
NCO  
デシメーションフィル  
タの通過領域リプル  
~(  
×
0.4 IQ  
の通過領域。  
レート)  
0
>80 dB  
デシメーションフィル  
タの帯域外減衰量  
×
レート)から  
の阻止帯域減衰量。  
0.6 IQ  
仕様  
NI PXI/PCI-5142  
24  
ni.com/jp  
仕様  
コメント  
復調性能(標準)  
変調構成  
IF  
測定タイプ  
変調誤差比(  
GSM  
62 dB  
MER  
物理層 1, 2, 8  
<0.2% rms  
エラーベクタマグニチュード  
(EVM)  
W-CDMA  
52 dB  
変調誤差比(  
MER  
物理層 1, 3, 8  
<0.4% rms  
エラーベクタマグニチュード  
(EVM)  
DVB  
48 dB  
変調誤差比(  
MER  
物理層 1, 4, 8  
<0.4% rms  
エラーベクタマグニチュード  
(EVM)  
20 MSymbols/s,  
64 QAM 1, 5, 8  
39 dB  
変調誤差比(  
MER  
<0.8% rms  
エラーベクタマグニチュード  
(EVM)  
26.09 MSymbols/s,  
64 QAM 1, 6, 8  
36 dB  
変調誤差比(  
帯域幅  
MER  
30 MHz  
<1.0% rms  
エラーベクタマグニチュード  
(EVM)  
34.78 MSymbols/s,  
64 QAM 1, 7, 8  
32 dB  
変調誤差比(  
帯域幅  
MER  
40 MHz  
<1.6% rms  
エラーベクタマグニチュード  
(EVM)  
1
垂直レンジ  
入力インピーダンス  
Ω、アナログフィルタ無し、  
キャリア  
= 1 (Vpk-pk),  
= 50  
25 MHz  
、ガウス型、  
270.833 kSymbols/s BT = 0.3  
2
3
4
5
6
7
8
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
= 1.25 MS/s MSK  
変調、  
= 6.25 MS/s QPSK  
変調、  
、ルートコサイン、α  
3.84 MSymbols/s = 0.22  
= 10 MS/s 32 QAM  
変調、  
変調、  
変調、  
変調、  
、ルートコサイン、α  
6.92 MSymbols/s = 0.15  
= 50 MS/s 64 QAM  
、ルートコサイン、α  
20 MSymbols/s = 0.15  
= 50 MS/s 64 QAM  
、ルートコサイン、α  
、ルートコサイン、α  
26.09 MSymbols/s  
34.78 MSymbols/s  
= 0.15  
= 0.15  
= 50 MS/s 64 QAM  
リサンプリング(サンプルレート変換 およびパルス成形を含む復調は、  
)
ツールキットを使用して  
コン  
PC/  
NI Modulation  
トローラで実行。  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
25  
仕様  
コメント  
ベースバンド復調性能(標準)  
変調構成  
IQ  
測定タイプ  
GSM  
41 dB  
変調誤差比(  
MER  
物理層 1, 2, 6, 7  
<0.8% rms  
エラーベクタマグニチュード  
(EVM)  
W-CDMA  
41 dB  
変調誤差比(  
MER  
物理層 1, 3, 6, 7  
<0.9% rms  
エラーベクタマグニチュード  
(EVM)  
DVB  
40 dB  
変調誤差比(  
MER  
物理層 1, 4, 6, 7  
<0.9% rms  
エラーベクタマグニチュード  
(EVM)  
33 dB  
変調誤差比(  
20 MSymbols/s  
MER  
1, 5, 6, 7  
64 QAM  
<1.4% rms  
エラーベクタマグニチュード  
(EVM)  
1
垂直レンジ  
入力インピーダンス  
Ω、アナログフィルタ無し  
= 50  
= 1 (Vpk-pk),  
2
3
4
5
6
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
= 1.25 MS/s MSK  
変調、  
、ガウス型、  
270.833 kSymbols/s BT = 0.3  
= 6.25 MS/s QPSK  
変調、  
、ルートコサイン、α  
3.84 MSymbols/s = 0.22  
= 10 MS/s 32 QAM  
変調、  
、ルートコサイン、α  
6.92 MSymbols/s = 0.15  
= 50 MS/s 64 QAM  
変調、  
、ルートコサイン、α  
20 MSymbols/s = 0.15  
リサンプリング(サンプルレート変換 およびパルス成形を含む復調は、  
)
ツールキットを使用して  
コン  
PC/  
NI Modulation  
トローラで実行。  
7
システム性能の測定。 ベースバンド生成は、 つの  
IQ  
同期対応  
任意波形発生器モジュールで実行。  
2
TClk  
NI PXI 5421  
仕様  
波形集録時間  
コメント  
64 MB  
256 MB  
最大集録時間  
複素( )モー  
IQ  
ドでは、集録時  
間は半分となり  
ます。  
0.336 s  
1.34 s  
サンプルレート  
無効  
= 100 MS/s  
OSP  
33.6 s  
サンプルレート  
実数モード、  
2 min 14 s  
= 1 MS/s  
有効  
OSP  
サンプルレート  
実数モード、  
5 min 36 s  
22 min 22 s  
= 100 kS/s  
有効  
OSP  
仕様  
NI PXI/PCI-5142  
26  
ni.com/jp  
10  
0
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
0
10  
20  
30  
40  
50  
๟ᵄᢙ 䋨MHz䋩  
デシメーションフィルタ周波数応答(実数モード、  
6
サンプルレート  
= 10 MS/s  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
27  
–10  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–120  
27.5  
22.5 23  
24  
25  
26  
27  
๟ᵄᢙ㩷䋨㪤㪟㫑䋩  
1, 2  
物理層  
7
GSM  
–20  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–125  
10  
15  
20  
25  
30  
35  
40  
๟ᵄᢙ㩷䋨MHz䋩  
1, 3  
物理層  
W-CDMA  
8
1
垂直レンジ  
入力インピーダンス  
Ω、アナログフィルタ無し、  
、ガウス型、  
BT = 0.3  
キャリア  
= 1 (Vpk-pk),  
= 50  
25 MHz  
2
3
4
5
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
= 4.17 MS/s MSK  
変調、  
変調、  
270.833 kSymbols/s  
= 25 MS/s QPSK  
、ルートコサイン、α  
= 0.22  
3.84 MSymbols/s  
= 25 MS/s 32 QAM  
変調、  
、ルートコサイン、α  
6.92 MSymbols/s = 0.15  
、ルートコサイン、α  
20 MSymbols/s = 0.15  
= 50 MS/s 64 QAM  
変調、  
仕様  
NI PXI/PCI-5142  
28  
ni.com/jp  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
–115  
10  
15  
20  
25  
๟ᵄᢙ㩷䋨㪤㪟㫑䋩  
30  
35  
40  
1, 4  
物理層  
9
DVB  
–30  
–40  
–50  
–60  
–70  
–80  
–90  
–100  
–110  
0
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
๟ᵄᢙ㩷䋨MHz䋩  
1, 5  
10 20 MSymbols/s 64 QAM  
1
垂直レンジ  
入力インピーダンス  
Ω、アナログフィルタ無し、  
、ガウス型、  
BT = 0.3  
キャリア  
= 1 (Vpk-pk),  
= 50  
25 MHz  
2
3
4
5
サンプルレート  
サンプルレート  
サンプルレート  
サンプルレート  
= 4.17 MS/s MSK  
変調、  
変調、  
270.833 kSymbols/s  
= 25 MS/s QPSK  
、ルートコサイン、α  
= 0.22  
3.84 MSymbols/s  
= 25 MS/s 32 QAM  
変調、  
、ルートコサイン、α  
6.92 MSymbols/s = 0.15  
、ルートコサイン、α  
20 MSymbols/s = 0.15  
= 50 MS/s 64 QAM  
変調、  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
29  
キャリブレーション  
仕様  
セルフキャリブレーション  
セルフキャリブレーションはソフトウェアコマンドで実行可能で  
ャリブレーションは全入力範囲において、ゲイン、オフ  
セット、周波数応答、トリガ、タイミング調整エラーを補正しま  
す。  
外部キャリブレーション  
(工場出荷時のキャリブレー  
ション)  
外部キャリブレーションは、  
切な定数は、不揮発性メモリに保管されます。  
および基準電圧を校正しま  
VCXO  
外部キャリブレーション間  
年間  
2
ウォームアップ時間  
15  
電源  
仕様  
標準値  
NI PXI-5142  
1.0 A  
NI PCI-5142  
+3.3 VDC  
+5 VDC  
3.4 A  
2.7 A  
1.7 A  
+12 VDC  
–12 VDC  
合計電力  
800 mA  
270 mA  
24.7 W  
110 mA  
0 A  
26.1 W  
仕様  
NI PXI/PCI-5142  
30  
ni.com/jp  
ソフトウェア  
仕様  
ドライバソフト  
ウェア  
以降。  
NI-SCOPE 3.0  
NI-SCOPE  
したドライバです。  
は、  
の構成、制御、および校正を行うための  
に準拠  
NI 5142  
IVI  
には、多くの開発環境に対応するアプリ  
NI-SCOPE  
ケーションプログラミングインタフェースが搭載されています。  
アプリケーション  
ソフトウェア  
には、以下のアプリケーション開発環境にプログラミングイン  
NI-SCOPE  
タフェース、ドキュメント、サンプルが含まれます。  
• LabVIEW  
• LabWindows /CVI  
TM  
TM  
• Measurement Studio  
• Microsoft Visual C/C++  
• Microsoft Visual Basic  
対話式ソフトフロ  
ントパネルおよび  
構成  
ソフトフロントパネル  
Scope  
以降では、  
ソフトフロントパネルは  
を対話式に制御する  
に含まれ  
Scope  
2.4  
NI 5142  
ことができます。  
ています。  
NI-SCOPE CD  
また、ナショナルインスツルメンツの  
)でも  
Measurement & Automation  
Explorer MAX  
を対話式に構成、そしてテストすることが  
に含まれています。  
NI 5142  
できます。  
MAX NI-SCOPE CD  
環境  
NI PXI-5142  
メモ  
の効率的な冷却方法については、  
キットに含まれている  
NI PXI-5142  
NI PXI-5142  
『強制空冷の維持について』のガイドラインに従ってください。  
は、  
NI PXI-5142  
室内使用を意図して設計されています。  
仕様  
動作温度  
コメント  
~+  
℃(以下を除くすべてのシャーシ。  
0
0
55  
℃(  
または  
シャーシに取  
+45  
NI PXI-1000/B  
PXI-101x  
り付けた場合。  
IEC-60068-2-1 IEC-60068-2-2  
に準拠。  
保管周辺温度  
–40 +71  
℃。  
に準拠。  
IEC-60068-2-1 IEC-60068-2-2  
動作時の相対湿度  
(結露なきこと)  
に準拠。  
10 90%  
IEC-60068-2-56  
仕様  
© National Instruments Corporation  
31  
NI PXI/PCI-5142  
仕様  
コメント  
保管時の相対湿度  
(結露なきこと)  
に準拠。  
5
95%  
IEC-60068-2-56  
動作衝撃  
、半正弦波、  
パルス。  
に準拠。  
30 g  
11 ms  
IEC-60068-2-27  
に従って開発されたテストプロファイ  
MIL-PRF-28800F  
ル。  
保管時衝撃  
、半正弦波、  
パルス。  
に準拠。  
50 g  
11 ms  
IEC-60068-2-27  
に従って開発されたテストプロファイ  
MIL-PRF-28800F  
ル。  
動作振動  
保管振動  
に準拠。  
5
5
500 Hz 0.31 grms IEC-60068-2-64  
に準拠。テスト  
の要件以上。  
500 Hz 2.46 grms IEC-60068-2-64  
プロファイルは、  
MIL-PRF-28800F Class B  
高度  
最高  
(周辺温度  
2.000 m  
℃時)  
25  
2
汚染度  
NI PCI-5142  
メモ  
に対して効率的な冷却を行うには、少なくとも  
カードへの通気  
NI PCI-5142  
PCI  
が確保できる能動冷却を付属するシャーシを使用してください気の確保やデ  
バイスの寿命に影響を与えないために、隣接している スロットにはデバイ  
PCI  
スを取り付けないでください要な冷却情報については、  
キット  
は、  
NI PCI-5142  
NI PCI-5142  
に含まれる『強制空冷の維持について』を参照してください。  
屋内での使用を意図して設計されています。  
仕様  
動作温度  
コメント  
℃。  
に準拠。  
0
+45  
IEC-60068-2-1 IEC-60068-2-2  
保管温度  
–40 +71  
℃。  
に準拠。  
IEC-60068-2-1 IEC-60068-2-2  
動作時の相対湿度  
保管時の相対湿度  
保管時衝撃  
(結露なきこと。  
に準拠。  
10 90%  
IEC-60068-2-56  
(結露なきこと。  
に準拠。  
5
95%  
IEC-60068-2-56  
、半正弦波、  
50 g  
パルス。  
に準拠。  
11 ms  
IEC-60068-2-27  
に従って開発されたテストプロファイ  
MIL-PRF-28800F  
ル。  
保管振動  
~ 、  
プロファイルは、  
に準拠。テスト  
の要件以上。  
5
500 Hz 2.46 grms IEC-60068-2-64  
MIL-PRF-28800F Class B  
高度  
最高  
(周辺温度  
2.000 m  
℃時)  
25  
2
汚染度  
仕様  
NI PXI/PCI-5142  
32  
ni.com/jp  
安全性、電磁両立性、  
適合  
CE  
安全性  
この製品は、以下の安全規格と、計測、制御、研究用電気機器に対する規  
格の要求事項を満たすように設計されています。  
IEC 61010-1 EN 61010-1  
UL 61010-1 CSA 61010-1  
メモ  
および他の安全保証については、製品のラベルを参照するか、ni.com/  
UL  
certification(英語)にアクセスしてモデル番号または製品ラインで検索  
し、保証の欄の該当するリンクをクリックしてください。  
電磁両立性  
この製品は、以下の  
規格と、計測、制御、研究用電気機器に対する  
EMC  
規格の要件を満たすように設計されています。  
必要条件、最小イミュニティ  
EN 61326 EMC  
エミッション(  
Group 1 Class A  
EN 55011  
、および  
パート  
エミッション(  
CE C-Tick ICES  
FCC  
15  
Class A  
メモ  
に適合させるには、このデバイスを  
または同等のシールドケー  
EMC  
RG223/U  
ブルと一緒に使用し品のドキュメントに従って動作してください  
適合  
CE  
この製品は、以下のように、  
マーク改正に基づいて、該当する  
CE  
事会指令による基本的要件に適合しています。  
EC  
、低電圧指令(安全性)  
2006/95/EC  
2004/108/EC  
、電磁両立性指令  
(EMC)  
メモ  
この製品のその他のコンプライアンス情報については、適合宣言(  
)をご  
DoC  
覧くださいの製品の適合宣言を入手するには、ni.com/certification  
(英語)にアクセスして型番または製品ラインで検索し、該当するリンクをク  
リックしてください。  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
33  
環境管理  
ナショナルインスツルメンツは、環境に考慮した製品の開発および製造に  
取り組んでいますショナルインスツルメンツは、弊社の製品から特定  
の有害性物質を排除することは、環境だけではなくお客様にも有益である  
ことを認識しています。  
環境情報に関する詳細は、ni.com/environment で  
NI and the  
(英語)のウェブページをご覧いただけますのページに  
Environment  
は、 が準拠している規制と規格や、このドキュメントには含まれてい  
NI  
ない環境情報についてが説明されています。  
廃電気電子機器  
(WEEE)  
欧州のお客様へ 製品寿命を過ぎたすべての製品は、必ず  
リサイクルセンターへ  
リサイクルセンターおよびナショナルインスツルメンツの  
WEEE  
送付してください。  
WEEE  
への対応に関する詳細は、ni.com/environment/weee.htm(英語)を参照して  
WEEE  
ください。  
⬉ᄤֵᙃѻક∵ᶧ᥻
ㅵ⧚
⊩ ˄Ё೑  
˅
RoHS  
Ё೑ᅶ᠋  
݇Ѣ  
ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤
Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ  
DŽ
National Instruments  
National Instruments  
(RoHS)  
Ё೑  
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ  
RoHS  
ni.com/environment/rohs_china  
(For information about China RoHS compliance, go to  
.)  
物理特性  
フロントパネルコネクタ  
ラベル  
関数  
アナログ入力  
コネクタタイプ  
CH 0  
メス  
BNC  
BNC  
BNC  
SMB  
CH 1  
TRIG  
アナログ入力  
外部トリガ  
メス  
メス  
CLK IN  
サンプルクロック入力およ  
び基準クロック入力  
ジャック  
CLK OUT  
AUX I/O  
サンプルクロック出力およ  
び基準クロック出力  
ジャック  
SMB  
PFI 0 PFI 1  
ピンミニサーキュラ  
9
DIN  
仕様  
NI PXI/PCI-5142  
34  
ni.com/jp  
フロントパネル表示器  
NI PXI-5142  
ラベル  
機能  
詳細については、  
高速デジタイ  
ザヘルプ』を参照  
してください。  
NI  
アクセス  
は、  
バスおよび  
ローラまでのインタフェースのステータスを示します。  
からコント  
ACCESS LED  
PCI  
NI PXI-5142  
アクティブ  
は、 のオンボード集録ハード  
ACTIVE LED  
NI PXI-5142  
ウェアのステータスを示します。  
外形寸法および重量  
NI PXI-5142  
外形寸法  
3U 1  
スロット、  
×
モジュール  
PXI/cPCI  
×
21.6 2.0 13.0 cm  
×
×
(8.5 0.8 5.1 in.)  
2.0 cm  
(0.8 in.)  
13.0 cm  
(5.1 in.)  
21.6 cm  
(8.5 in.)  
459 g (16.2 oz)  
重量  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
35  
NI PCI-5142  
×
×
35.5 2.0 11.3 cm  
外形寸法  
×
×
(14.0 0.8 4.4 in.)  
2.0 cm  
(0.8 in.)  
11.3 cm  
(4.4 in.)  
35.5 cm  
(14.0 in.)  
470 g (16.6 oz)  
重量  
仕様  
NI PXI/PCI-5142  
36  
ni.com/jp  
サポート情報  
技術サポートリソースの一覧は、ナショナルインスツルメンツのウェブサ  
イトでご覧いただけますni.com/jp/support では、トラブルシュー  
ティングやアプリケーション開発のセルフヘルプリソースから、ナショナ  
ルインスツルメンツのアプリケーションエンジニアの メール 電話の連  
E
/
絡先(  
す。  
)まで、あらゆるリソースを参照することができま  
0120-527196  
適合宣言( )とは、その会社の自己適合宣言を用いた、さまざまな  
Doc  
欧州閣僚理事会指令への適合の宣言のことです。 この制度により、電磁  
に対するユーザ保護や製品の安全性に関する情報が提供さ  
適合性(  
EMC)  
ni.com/certification  
れます使用の製品の適合宣言は、 (英語)  
から入手できます使用の製品でキャリブレーションがサポートされて  
いる場合、ni.com/calibration からその製品の  
Calibration  
(英語)を入手してご利用になることもできます。  
Certificate  
ナショナルインスツルメンツでは、米国本社(  
11500 North Mopac  
)および各国の現地オフィスに  
Expressway, Austin, Texas, 78759-3504  
てお客様にサポート対応しています本国内でのサポートについては、  
サービスリクエストを ni.com/jp/support で作成するか、  
(フリーダイヤル)または  
(大代表)にお電  
0120-527196  
03-5472-2970  
話ください。日本国外での電話サポートについては、各国の営業所にご連  
絡ください。  
イスラエル  
インド  
、イタリア  
972 3 6393737  
91 80 41190000  
39 02 41309277  
、英国  
44 0 1635 523545  
オーストラリア  
、オーストリア  
1800 300 800  
43 662 457990-0  
オランダ  
韓国  
ナダ  
31 (0) 348 433 466  
82 02 3451 3400  
800 433 3488  
、シンガポール  
ウェーデン  
、スロベニア  
1800 226 5886  
スイス  
41 56 2005151  
46 (0) 8 587 895 00  
386 3 425 42 00  
スペイン  
タイ  
34 91 640 0085  
、台湾  
、中国  
662 278 6777  
886 02 2377 2222  
86 21 5050 9800  
チェコ  
、デンマーク  
420 224 235 774  
45 45 76 26 00  
ドイツ  
ルコ  
49 89 7413130  
90 212 279 3031  
ニュージーランド  
、ノルウェー  
0800 553 322  
47 (0) 66 90 76 60  
フィンランド  
、フランス  
358 (0) 9 725 72511  
01 57 66 24 24  
ベルギー  
、ブラジル  
32 (0) 2 757 0020  
55 11 3262 3599  
ポーランド  
マレーシア  
メキシコ  
ルトガル  
48 22 3390150  
1 800 887710  
01 800 010 0793  
7 495 783 6851  
351 210 311 210  
、南アフリカ  
27 0 11 805 8197  
961 (0) 1 33 28 28  
、レバノン  
ロシア  
仕様  
NI PXI/PCI-5142  
© National Instruments Corporation  
37  
、および  
National Instruments NI ni.com  
LabVIEW National Instruments Corporation  
(米国ナショナルインスツルメンツ社)の商標です。  
の商標の詳細については、  
National Instruments  
ni.com/legal の「  
」セクションを参照してください。本文書中に記載されたその他の  
Terms of Use  
製品名および企業名は、それぞれの企業の商標または商号です。  
の製品を保護  
National Instruments  
する特許については、ソフトウェアに含まれている特許情報(ヘルプ→特許情報)  
patents.txt ファイル、または ni.com/patents のうち、該当するリソースから参照してください。  
に含まれている  
CD  
.
© 2006–2007 National Instruments Corporation. All rights reserved  
374300C-01  
2007 10  

相关型号:

PXI-5404

9 kHz to 105 MHz sine wave/DC to 100 MHz clock/1.07 μHz frequency resolution
NI

PXI-5422

200 MS/s, 16-Bit Arbitrary Waveform Generator
NI

PXI-5441

100 MS/s, 16-bit Arbitrary Waveform Generator with Onboard Signal Processing
NI

PXI-5670

250 kHz to 2.7 GHz/8, 32 or 256 MB memory
NI

PXI-5671

250 kHz to 2.7 GHz/16-bit resolution, 100 MS/s arbitrary waveform generation
NI

PXI-6052E

Converter IC
ETC

PXI-6509

Low-Cost Industrial Digital I/O-5 V TTL/CMOS
NI

PXI-6529

24 or 48 channel-to-channel optically isolated inputs and solid-state relay outputs
NI

PXI-6541

100 and 50 MHz Digital Waveform Generator/Analyzers
NI

PXI-665X

PXI and PXI Express Timing and Synchronization Control
NI

PXI-6682

GPS, IEEE 1588, and IRIG-B Timing and Synchronization Modules for PXI and PXI Express
NI

PXI-7901

PXI specifications Rev. 2.2 compliant
ETC