MVTX2603A [ETC]
Unmanaged 24 port 10/100Mb + 2 port 1Gb Ethernet switch ; 非网管型24端口10 / 100兆+ 2端口千兆以太网交换机\n型号: | MVTX2603A |
厂家: | ETC |
描述: | Unmanaged 24 port 10/100Mb + 2 port 1Gb Ethernet switch
|
文件: | 总111页 (文件大小:1374K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MVTX2603
Integrated 10/100/1000 Mbps Ethernet Switch
Data Sheet
DS5764
Issue 7
October 2002
Features
Ordering Information
•
•
•
Integrated Single-Chip 10/100/1000 Mbps
Ethernet Switch
MVTX2603AG
553 Pin BGA
24 10/100 Mbps Autosensing, Fast Ethernet
Ports with RMII or Serial Interface (7WS)
-40°C to +85°C
2 Gigabit Ports with GMII, PCS, 10/100 and
stacking (2G per port) interface options per port
•
•
Supports per-system option to enable flow control
for best effort frames even on QoS-enabled ports
Load sharing among trunked ports can be based
on source MAC and/or destination MAC. The
Gigabit trunking group has one more option,
based on source port.
•
•
Serial interface for configuration
Supports two Frame Buffer Memory domains with
SRAM at 100 MHz
•
Supports memory size 2 MB, or 4 MB
• For 24+2, two SRAM domains (2 MB or 4 MB) are
required.
•
•
Port Mirroring to a dedicated port or port 23
Built-in reset logic triggered by system
• For 24+2 stacking (2G per stacking port), two ZBT
domains (2 MB or 4 MB) are required.
malfunction
•
•
•
•
Applies centralized shared memory architecture
Up to 64K MAC addresses
•
•
I2C EEPROM for configuration
Traffic Classification
Maximum throughput is 6.4 Gbps non-blocking
• 4 transmission priorities for Fast Ethernet ports with 2
dropping levels
High performance packet forwarding (9.524M
packets per second) at full wire speed
• Classification based on:
•
•
•
Full Duplex Ethernet IEEE 802.3x Flow Control
Backpressure flow control for Half Duplex ports
-
-
-
-
Port based priority
VLAN Priority field in VLAN tagged frame
DS/TOS field in IP packet
Supports Ethernet multicasting and broadcasting
and flooding control
UDP/TCP logical ports: 8 hard-wired and 8
Frame Data Buffer A
SRAM (1M / 2M)
Frame Data Buffer B
SRAM (1M / 2M)
FDB Interface
LED
Search
Engine
MCT
Link
FCB
Frame Engine
GMII/
GMII/
24 x 10 /100
PCS
PCS
Port
24
Management
Module
Parallel/
Serial
RMII
Port
25
Ports 0 - 23
Figure 1 - MVTX2603AG System Block Diagram
1
MVTX2603
Data Sheet
programmable ports, including one programmable range
• The precedence of the above classifications is programmable.
QoS Support
•
• Supports IEEE 802.1p/Q Quality of Service with 4 transmission priority queues with delay bounded, strict priority, and
WFQ service disciplines
• Provides 2 levels of dropping precedence with WRED mechanism
• User controls the WRED thresholds.
• Buffer management: per class and per port buffer reservations
• Port-based priority: VLAN priority in a tagged frame can be overwritten by the priority of Port VLAN ID.
•
•
3 port trunking groups, one for the 2 Gigabit ports, and two groups for 10/100 ports, with up to 4 10/100
ports per group
Full set of LED signals provided by a serial interface, or 6 LED signals dedicated to Gigabit port status only
(without serial interface)
•
•
•
Hardware auto-negotiation through serial management interface (MDIO) for Ethernet ports
Hardware auto-negotiation through serial management interface (MDIO) for Ethernet ports
Built-In Self Test for internal and external SRAM
Description
The MVTX2603AG is a high density, low cost, high performance, non-blocking Ethernet switch chip. A single
chip provides 24 ports at 10/100 Mbps, 2 ports at 1000 Mbps. The Gigabit ports can also support 10/100M and
2G stacking modes.
The chip supports up to 64K MAC addresses. The centralized shared memory architecture permits a very high
performance packet forwarding rate at up to 9.524M packets per second at full wire speed. The chip is
optimized to provide low-cost, high-performance workgroup switching.
Two Frame Buffer Memory domains utilize cost-effective, high-performance synchronous SRAM with aggregate
bandwidth of 12.8 Gbps to support full wire speed on all ports simultaneously. In the 24+2 stacking (2G per
stacking port) configuration, 2 ZBT domains are needed.
With delay bounded, strict priority, and/or WFQ transmission scheduling, and WRED dropping schemes, the
MVTX2603AG provides powerful QoS functions for various multimedia and mission-critical applications. The
chip provides 4 transmission priorities (8 priorities per Gigabit port) and 2 levels of dropping precedence. Each
packet is assigned a transmission priority and dropping precedence based on the VLAN priority field in a VLAN
tagged frame, or the DS/TOS field, or the UDP/TCP logical port fields in IP packets. The MVTX2603AG
recognizes a total of 16 UDP/TCP logical ports, 8 hard-wired and 8 programmable (including one programmable
range).
The MVTX2603AG supports 3 groups of port trunking/load sharing. One group is dedicated to the two Gigabit
ports, and the other two groups to 10/100 ports, where each 10/100 group can contain up to 4 ports. Port
trunking/load sharing can be used to group ports between interlinked switches to increase the effective network
bandwidth.
In half-duplex mode, all ports support backpressure flow control, to minimize the risk of losing data during long
activity bursts. In full-duplex mode, IEEE 802.3x flow control is provided. The MVTX2603AG also supports a
per-system option to enable flow control for best effort frames, even on QoS-enabled ports.
The Physical Coding Sublayer (PCS) is integrated on-chip to provide a direct 10-bit interface for connection to
SERDES chips. The PCS can be bypassed to provide a GMII interface.
The MVTX2603AG is fabricated using 0.25 micron technology. Inputs, however, are 3.3 V tolerant, and the
outputs are capable of directly interfacing to LVTTL levels. The MVTX2603AG is packaged in a 553-pin Ball
Grid Array package.
2
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Table of Contents
Features ...................................................................................................................................1
Description ...............................................................................................................................2
1.0 Block Functionality..........................................................................................................11
1.1 Frame Data Buffer (FDB) Interfaces..........................................................................................................11
1.2 GMII/PCS MAC Module (GMAC) ..............................................................................................................11
1.3 Physical Coding Sublayer (PCI) Interface .................................................................................................11
1.4 10/100 MAC Module (RMAC)....................................................................................................................11
1.5 Configuration Interface Module .................................................................................................................12
1.6 Frame Engine............................................................................................................................................12
1.7 Search Engine...........................................................................................................................................12
1.8 LED Interface.............................................................................................................................................12
1.9 Internal Memory.........................................................................................................................................12
2.0 System Configuration......................................................................................................12
2.1 Configuration Mode ...................................................................................................................................12
2.2 I2C Interface..............................................................................................................................................12
2.2.1 Start Condition .................................................................................................................................12
2.2.2 Address............................................................................................................................................13
2.2.3 Data Direction ..................................................................................................................................13
2.2.4 Acknowledgment..............................................................................................................................13
2.2.5 Data..................................................................................................................................................13
2.2.6 Stop Condition..................................................................................................................................13
2.3 Synchronous Serial Interface ....................................................................................................................13
2.3.1 Write Command ...............................................................................................................................14
2.3.2 Read Command...............................................................................................................................14
2.4 Stacking.....................................................................................................................................................14
3.0 MVTX2603AG Data Forwarding Protocol.......................................................................14
3.1 Unicast Data Frame Forwarding................................................................................................................14
3.2 Multicast Data Frame Forwarding .............................................................................................................15
4.0 Memory Interface..............................................................................................................16
4.1 Overview....................................................................................................................................................16
4.2 ZBT Support ..............................................................................................................................................16
4.3 Detailed Memory Information ....................................................................................................................16
4.4 Memory Requirements ..............................................................................................................................17
5.0 Search Engine ..................................................................................................................17
5.1 Search Engine Overview...........................................................................................................................17
5.2 Basic Flow .................................................................................................................................................17
5.3 Search, Learning, and Aging.....................................................................................................................18
5.3.1 MAC Search.....................................................................................................................................18
5.3.2 Learning ...........................................................................................................................................18
5.3.3 Aging................................................................................................................................................18
5.4 Quality of Service ......................................................................................................................................18
5.5 Priority Classification Rule.........................................................................................................................19
5.6 Port Based VLAN ......................................................................................................................................20
5.7 Memory Configurations .............................................................................................................................20
6.0 Frame Engine....................................................................................................................24
6.1 Data Forwarding Summary........................................................................................................................24
6.2 Frame Engine Details................................................................................................................................24
6.2.1 FCB Manager...................................................................................................................................24
6.2.2 Rx Interface......................................................................................................................................24
6.2.3 RxDMA.............................................................................................................................................24
Zarlink Semiconductor Inc.
3
MVTX2603
Data Sheet
Table of Contents
6.2.4 TxQ Manager ...................................................................................................................................24
6.3 Port Control................................................................................................................................................25
6.4 TxDMA.......................................................................................................................................................25
7.0 Quality of Service and Flow Control.............................................................................. 25
7.1 Model.........................................................................................................................................................25
7.2 Four QoS Configurations...........................................................................................................................26
7.3 Delay Bound ..............................................................................................................................................27
7.4 Strict Priority and Best Effort......................................................................................................................27
7.5 Weighted Fair Queuing..............................................................................................................................28
7.6 Shaper .......................................................................................................................................................28
7.7 WRED Drop Threshold Management Support...........................................................................................29
7.8 Buffer Management ...................................................................................................................................29
7.8.1 Dropping When Buffers Are Scarce .................................................................................................30
7.9 MVTX2603AG Flow Control Basics...........................................................................................................31
7.9.1 Unicast Flow Control ........................................................................................................................31
7.9.2 Multicast Flow Control......................................................................................................................31
7.10 Mapping to IETF Diffserv Classes ...........................................................................................................32
8.0 Port Trunking ................................................................................................................... 33
8.1 Features and Restrictions..........................................................................................................................33
8.2 Unicast Packet Forwarding........................................................................................................................33
8.3 Multicast Packet Forwarding......................................................................................................................33
8.4 Trunking.....................................................................................................................................................34
9.0 Port Mirroring................................................................................................................... 34
9.1 Port Mirroring Features..............................................................................................................................34
9.2 Setting Registers for Port Mirroring............................................................................................................34
10.0 TBI Interface................................................................................................................... 35
11.0 GPSI (7WS) Interface..................................................................................................... 36
11.1 11.1GPSI Connection..............................................................................................................................36
11.2 SCAN LINK and SCAN COL interface.....................................................................................................37
12.0 LED Interface.................................................................................................................. 37
12.1 LED Interface Introduction .......................................................................................................................37
12.2 Port Status...............................................................................................................................................37
12.3 LED Interface Timing Diagram.................................................................................................................38
13.0 Register Definition......................................................................................................... 39
13.1 MVTX2603AG Register Description ........................................................................................................39
13.2 Group 0 Address MAC Ports Group ........................................................................................................43
13.2.1 ECR1Pn: Port N Control Register ..................................................................................................43
13.2.2 ECR2Pn: Port N Control Register ..................................................................................................44
13.2.3 GGControl – Extra GIGA Port Control............................................................................................45
13.3 Group 1 Address VLAN Group ................................................................................................................46
13.3.1 AVTCL – VLAN Type Code Register Low......................................................................................46
13.3.2 AVTCH – VLAN Type Code Register High ....................................................................................46
13.3.3 PVMAP00_0 – Port 00 Configuration Register 0 ...........................................................................46
13.3.4 PVMAP00_1 – Port 00 Configuration Register 1 ...........................................................................46
13.3.5 PVMAP00_2 – Port 00 Configuration Register 2 ...........................................................................46
13.3.6 PVMAP00_3 – Port 00 Configuration Register 3 ...........................................................................47
13.4 Port Configuration Register......................................................................................................................47
13.4.1 PVMODE........................................................................................................................................48
13.4.2 TRUNK0_MODE– Trunk group 0 mode.........................................................................................48
4
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Table of Contents
13.4.3 TRUNK1_MODE – Trunk group 1 mode........................................................................................49
13.4.4 TRUNK1_HASH0 – Trunk group 1 hash result 0 destination port number....................................49
13.4.5 TX_AGE – Tx Queue Aging timer..................................................................................................49
13.5 Group 4 Address Search Engine Group..................................................................................................49
13.5.1 AGETIME_LOW – MAC address aging time Low..........................................................................49
13.5.2 AGETIME_HIGH –MAC address aging time High .........................................................................50
13.5.3 V_AGETIME – VLAN to Port aging time........................................................................................51
13.5.4 SE_OPMODE – Search Engine Operation Mode..........................................................................51
13.6 Group 5 Address Buffer Control/QOS Group ..........................................................................................51
13.6.1 FCBAT – FCB Aging Timer............................................................................................................51
13.6.2 QOSC – QOS Control....................................................................................................................51
13.6.3 FCR – Flooding Control Register...................................................................................................52
13.6.4 AVPML – VLAN Priority Map .........................................................................................................53
13.6.5 AVPMM – VLAN Priority Map ........................................................................................................53
13.6.6 AVPMH – VLAN Priority Map.........................................................................................................53
13.6.7 TOSPML – TOS Priority Map.........................................................................................................55
13.6.8 TOSPMM – TOS Priority Map........................................................................................................55
13.6.9 TOSPMH – TOS Priority Map ........................................................................................................55
13.6.10 AVDM – VLAN Discard Map ........................................................................................................56
13.6.11 TOSDML – TOS Discard Map......................................................................................................56
13.6.12 BMRC - Broadcast/Multicast Rate Control...................................................................................57
13.6.13 UCC – Unicast Congestion Control..............................................................................................57
13.6.14 MCC – Multicast Congestion Control...........................................................................................57
13.6.15 PR100 – Port Reservation for 10/100 ports .................................................................................58
13.6.16 PRG – Port Reservation for Giga ports........................................................................................58
13.6.17 SFCB – Share FCB Size..............................................................................................................59
13.6.18 C2RS – Class 2 Reserve Size .....................................................................................................59
13.6.19 C3RS – Class 3 Reserve Size .....................................................................................................59
13.6.20 C4RS – Class 4 Reserve Size .....................................................................................................59
13.6.21 C5RS – Class 5 Reserve Size .....................................................................................................59
13.6.22 C6RS – Class 6 Reserve Size .....................................................................................................60
13.6.23 C7RS – Class 7 Reserve Size .....................................................................................................60
13.6.24 Classes Byte Limit Set 0..............................................................................................................60
13.6.25 Classes Byte Limit Set 1..............................................................................................................60
13.6.26 Classes Byte Limit Set 2..............................................................................................................60
13.6.27 Classes Byte Limit Set 3..............................................................................................................61
13.6.28 Classes Byte Limit Giga Port 1 ....................................................................................................61
13.6.29 Classes Byte Limit Giga Port 2 ....................................................................................................61
13.6.30 Classes WFQ Credit Set 0...........................................................................................................62
13.6.31 Classes WFQ Credit Set 1...........................................................................................................62
13.6.32 Classes WFQ Credit Set 2...........................................................................................................62
13.6.33 Classes WFQ Credit Set 3...........................................................................................................63
13.6.34 Classes WFQ Credit Port G1.......................................................................................................63
13.6.35 Classes WFQ Credit Port G2.......................................................................................................63
13.6.36 Class 6 Shaper Control Port G1...................................................................................................64
13.6.37 Class 6 Shaper Control Port G2...................................................................................................64
13.6.38 RDRC0 – WRED Rate Control 0..................................................................................................64
13.6.39 RDRC1 – WRED Rate Control 1..................................................................................................64
13.6.40 User Defined Logical Ports and Well Known Ports......................................................................65
13.7 Group 6 Address MISC Group ................................................................................................................70
13.7.1 MII_OP0 – MII Register Option 0...................................................................................................70
13.7.2 MII_OP1 – MII Register Option 1...................................................................................................70
Zarlink Semiconductor Inc.
5
MVTX2603
Data Sheet
Table of Contents
13.7.3 FEN – Feature Register .................................................................................................................71
13.7.4 MIIC0 – MII Command Register 0..................................................................................................71
13.7.5 MIIC1 – MII Command Register 1..................................................................................................71
13.7.6 MIIC2 – MII Command Register 2..................................................................................................72
13.7.7 MIIC3 – MII Command Register 3..................................................................................................72
13.7.8 MIID0 – MII Data Register 0...........................................................................................................72
13.7.9 MIID1 – MII Data Register 1...........................................................................................................72
13.7.10 LED Mode – LED Control.............................................................................................................72
13.7.11 CHECKSUM - EEPROM Checksum............................................................................................73
13.8 Group 7 Address Port Mirroring Group...................................................................................................73
13.8.1 MIRROR1_SRC – Port Mirror source port .....................................................................................73
13.8.2 MIRROR1_DEST – Port Mirror destination....................................................................................74
13.8.3 MIRROR2_SRC – Port Mirror source port .....................................................................................74
13.8.4 MIRROR2_DEST – Port Mirror destination....................................................................................74
13.9 Group F Address CPU Access Group .....................................................................................................74
13.9.1 GCR-Global Control Register.........................................................................................................74
13.9.2 DCR-Device Status and Signature Register ..................................................................................75
13.9.3 DCR1-Giga port status...................................................................................................................75
13.9.4 DPST – Device Port Status Register..............................................................................................76
13.9.5 DTST – Data read back register.....................................................................................................77
13.9.6 DA – DA Register...........................................................................................................................77
13.10 TBI Registers.........................................................................................................................................77
13.10.1 Control Register ...........................................................................................................................77
13.10.2 Status Register.............................................................................................................................78
13.10.3 Advertisement Register................................................................................................................78
13.10.4 Link Partner Ability Register.........................................................................................................79
13.10.5 Expansion Register ......................................................................................................................79
13.10.6 Extended Status Register.............................................................................................................80
14.0 BGA and Ball Signal Descriptions ............................................................................... 81
14.1 BGA Views...............................................................................................................................................81
14.1.1 Encapsulated View.........................................................................................................................81
14.1.2 Power and Ground Distribution ......................................................................................................82
14.2 Ball – Signal Descriptions........................................................................................................................83
14.2.1 Ball Signal Descriptions..................................................................................................................83
14.3 Ball – Signal Name ..................................................................................................................................91
14.4 AC/DC Timing..........................................................................................................................................97
14.4.1 Absolute Maximum Ratings............................................................................................................97
14.4.2 DC Electrical Characteristics..........................................................................................................98
14.4.3 Recommended Operation Conditions ............................................................................................98
14.5 Local Frame Buffer SBRAM Memory Interface........................................................................................98
14.5.1 Local SBRAM Memory Interface....................................................................................................98
14.6 Local Switch Database SBRAM Memory Interface................................................................................100
14.6.1 Local SBRAM Memory Interface:.................................................................................................100
14.7 AC Characteristics.................................................................................................................................102
14.7.1 Reduced Media Independent Interface ........................................................................................102
14.7.2 LED Interface ...............................................................................................................................107
14.7.3 SCANLINK SCANCOL Output Delay Timing ...............................................................................107
14.7.4 MDIO Input Setup and Hold Timing .............................................................................................108
14.7.5 I2C Input Setup Timing.................................................................................................................109
14.7.6 Serial Interface Setup Timing.......................................................................................................110
6
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
List of Figures
Figure 1 - MVTX2603AG System Block Diagram ...................................................................................................1
Figure 2 - Data Transfer Format for I2C Interface .................................................................................................12
Figure 3 - Write Command ....................................................................................................................................14
Figure 4 - Read Command ...................................................................................................................................14
Figure 5 - MVTX2603AG SRAM Interface Block Diagram (DMAs for 10/1000 Ports Only) ..................................16
Figure 6 - Memory Map .........................................................................................................................................17
Figure 7 - Priority Classification Rule ....................................................................................................................19
Figure 8 - Memory Configuration For: 2 banks, 1 layer, 2MB total .......................................................................22
Figure 9 - Memory Configuration For: 2 banks, 2 Layer, 4MB total ......................................................................22
Figure 10 - Memory Configuration For: 2 banks, 1 layer, 4MB .............................................................................22
Figure 11 - Memory Configuration For: 2 banks, 2 layers, 4MB total ....................................................................23
Figure 12 - Memory Configuration For: 2 banks, 1 layer, 4MB .............................................................................23
Figure 13 - Buffer Partition Scheme Used to Implement MVTX2603AG Buffer Management ..............................30
Figure 14 - TBI Connection ...................................................................................................................................35
Figure 15 - GPSI (7WS) mode connection diagram ..............................................................................................36
Figure 16 - SCAN LINK and SCAN COLLISON status diagram ...........................................................................37
Figure 17 - Timing Diagram of LED Interface .......................................................................................................38
Figure 18 - BGA View ...........................................................................................................................................81
Figure 19 - Power and Ground Distribution View ..................................................................................................82
Figure 20 - Local Memory Interface – Input setup and hold timing .......................................................................99
Figure 21 - Local Memory Interface - Output valid delay timing ............................................................................99
Figure 22 - Local Memory Interface – Input setup and hold timing .....................................................................100
Figure 23 - Local Memory Interface - Output valid delay timing ..........................................................................101
Figure 24 - AC Characteristics – Reduced Media Independent Interface ...........................................................102
Figure 25 - AC Characteristics – Reduced Media Independent Interface ...........................................................102
Figure 26 - AC Characteristics- GMII ..................................................................................................................103
Figure 27 - AC Characteristics – Gigabit Media Independent Interface ..............................................................103
Figure 28 - AC Characteristics – Gigabit Media Independent Interface ..............................................................103
Figure 29 - Gigabit TBI Interface Transmit Timing ..............................................................................................104
Figure 30 - Gigabit TBI Interface Receive Timing ...............................................................................................104
Figure 31 - AC Characteristics- GMII ..................................................................................................................105
Figure 32 - AC Characteristics – Gigabit Media Independent Interface ..............................................................105
Figure 33 - Gigabit TBI Interface Transmit Timing ..............................................................................................106
Figure 34 - Gigabit TBI Interface Timing .............................................................................................................106
Figure 35 - AC Characteristics – LED Interface ..................................................................................................107
Figure 36 - SCANLINK SCANCOL Output Delay Timing ....................................................................................107
Figure 37 - SCANLINK, SCANCOL Setup Timing ..............................................................................................107
Figure 38 - MDIO Input Setup and Hold Timing ..................................................................................................108
Figure 39 - MDIO Output Delay Timing ..............................................................................................................108
Figure 40 - I2C Input Setup Timing .....................................................................................................................109
Figure 41 - I2C Output Delay Timing ..................................................................................................................109
Figure 42 - Serial Interface Setup Timing ...........................................................................................................110
Figure 43 - Serial Interface Output Delay Timing ................................................................................................110
Zarlink Semiconductor Inc.
7
MVTX2603
Data Sheet
8
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
List of Tables
Table 1 - Memory Configuration ..........................................................................................................................17
Table 2 - PVMAP Register ...................................................................................................................................20
Table 3 - Supported Memory Configurations (Pipeline SBRAM Mode) ...............................................................20
Table 4 - Supported Memory Configurations (ZBT Mode) ...................................................................................21
Table 5 - Options for Memory Configuration ........................................................................................................21
Table 6 - Two-dimensional World Traffic .............................................................................................................25
Table 7 - Four QoS Configurations for a 10/100 Mbps Port ................................................................................26
Table 8 - Four QoS Configurations for a Gigabit Port ..........................................................................................27
Table 9 - WRED Drop Thresholds .......................................................................................................................29
Table 10 - Mapping between MVTX2603AG and IETF Diffserv Classes for Gigabit Ports ..................................32
Table 11 - Mapping between MVTX2603AG and IETF Diffserv Classes for 10/100 Ports ..................................32
Table 12 - MVTX2603AG Features Enabling IETF Diffserv Standards ...............................................................32
Table 13 - AC Characteristics – Local frame buffer SBRAM Memory Interface ...............................................100
Table 14 - AC Characteristics – Local Switch Database SBRAM Memory Interface .........................................101
Table 15 - AC Characteristics – Reduced Media Independent Interface ...........................................................102
Table 16 - Output Delay Timing .........................................................................................................................104
Table 17 - Input Setup Timing ............................................................................................................................104
Table 18 - AC Characteristics – Gigabit Media Independent Interface ..............................................................105
Table 19 - Output Delay Timing .........................................................................................................................106
Table 20 - Input Setup Timing ............................................................................................................................106
Table 21 - AC Characteristics – LED Interface ..................................................................................................107
Table 22 - SCANLINK, SCANCOL Timing .........................................................................................................108
Table 23 - MDIO Timing .....................................................................................................................................108
Table 24 - I2C Timing ........................................................................................................................................109
Table 25 - Serial Interface Timing ......................................................................................................................110
Zarlink Semiconductor Inc.
9
MVTX2603
Data Sheet
10
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
1.0
1.1
Block Functionality
Frame Data Buffer (FDB) Interfaces
The FDB interface supports pipelined synchronrous burst SRAM (SBRAM) memory at 100 MHz. To ensure a
non-blocking switch, two memory domains are required. Each domain has a 64 bit wide memory bus. At 100
MHz, the aggregate memory bandwidth is 12.8 Gbps, which is enough to support 24 10/100 Mbps and 2 Gigabit
ports at full wire speed switching. For 24+ 2 stacking application, ZBT memory at 125 MHz is required.
The Switching Database is also located in the external SBRAM; it is used for storing MAC addresses and their
physical port number. It is duplicated and stored in both memory domains. Therefore, when the system updates
the contents of the switching database, it has to write the entry to both domains at the same time.
1.2
GMII/PCS MAC Module (GMAC)
The GMII/PCS Media Access Control (MAC) module provides the necessary buffers and control interface
between the Frame Engine (FE) and the external physical device (PHY).
The MVTX2603AG GMAC implements both GMII and MII interfaces, which offers a simple migration from
10/100 to 1G. The GMAC of the MVTX2603AG meets the IEEE 802.3Z specification. It is able to operate in
10M/100M either Half or Full Duplex mode with a back pressure/flow control mechanism or in 1G full duplex
mode with flow control mechanism. Furthermore, it will automatically retransmit upon collision for up to 16 total
transmissions. PHY addresses for GMAC are 01h and 02h.
1.3
Physical Coding Sublayer (PCI) Interface
For the MVTX2603AG, the 1000BASE-X PCI Interface is designed internally and may be utilized in the absence
of a GMII. The PCS incorporates all the functions required by the GMII to include encoding (decoding) 8B GMII
data to (from) 8B/10B TBI format for PHY communication and generating Collision Detect (COL) signals for
half-duplex mode. It also manages the Auto negotiation process by informing the management entity that the
PHY is ready for communications. The on-chip TBI may be disabled if TBI exists within the Gigabit PHY. The
TBI interface provides a uniform interface for all 1000 Mbps PHY implementations.
The PCS comprises the PCS Transmit, Synchronization, PCS Receive, and Auto negotiation processes for
1000BASE-X.
The PCS Transmit process sends the TBI signals TXD [9:0] to the physical medium and generates the GMII
Collision Detect (COL) signal based on whether a reception is occurring simultaneously with transmission.
Additionally, the Transmit process generates an internal “transmitting” flag and monitors Auto negotiation to
determine whether to transmit data or to reconfigure the link.
The PCS Synchronization process determines whether or not the receive channel is operational.
The PCS Receive process generates RXD [7:0] on the GMII from the TBI data [9:0], and the internal “receiving”
flag for use by the Transmit processes.
The PCS Auto negotiation process allows the MVTX2603AG to exchange configuration information between
two devices that share a link segment, and to automatically configure the link for the appropriate speed of
operation for both devices.
1.4
10/100 MAC Module (RMAC)
The 10/100 Media Access Control module provides the necessary buffers and control interface between the
Frame Engine (FE) and the external physical device (PHY). The MVTX2603AG has two interfaces, RMII or
Serial (only for 10M). The 10/100 MAC of the MVTX2603AG device meets the IEEE 802.3 specification. It is
able to operate in either Half or Full Duplex mode with a back pressure/flow control mechanism. In addition, it
will automatically retransmit upon collision for up to 16 total transmissions. The PHY address for 24 10/100
MAC are from 08h to 1fh.
Zarlink Semiconductor Inc.
11
MVTX2603
Data Sheet
1.5
Configuration Interface Module
The MVTX2603AG supports a serial and an I2C interface, which provides an easy way to configure the system.
Once configured, the resulting configuration can be stored in an I2C EEPROM.
1.6
Frame Engine
The main function of the frame engine is to forward a frame to its proper destination port or ports. When a frame
arrives, the frame engine parses the frame header (64 bytes) and formulates a switching request, which is sent
to the search engine, to resolve the destination port. The arriving frame is moved to the FDB. After receiving a
switch response from the search engine, the frame engine performs transmission scheduling based on the
frame’s priority. The frame engine forwards the frame to the MAC module when the frame is ready to be sent.
1.7
Search Engine
The Search Engine resolves the frame’s destination port or ports according to the destination MAC address
(L2). It also performs MAC learning, priority assignment, and trunking functions.
1.8
LED Interface
The LED interface provides a serial interface for carrying 24+2 port status signals. It can also provide direct
status pins (6) for the two Gigabit ports.
1.9
Internal Memory
Several internal tables are required and are described as follows:
•
•
Frame Control Block (FCB) - Each FCB entry contains the control information of the associated frame
stored in the FDB, e.g. frame size, read/write pointer, transmission priority, etc.
MCT Link Table - The MCT Link Table stores the linked list of MCT entries that have collisions in the
external MAC Table. The external MAC table is located in the FDB Memory.
Note: the external MAC table is located in the external SBRAM Memory.
2.0
2.1
System Configuration
Configuration Mode
The MVTX2603AG can be configured by EEPROM (24C02 or compatible) via an I2C interface at boot time, or
via a synchronous serial interface during operation.
2
2.2
I C Interface
The I2C interface uses two bus lines, a serial data line (SDA) and a serial clock line (SCL). The SCL line carries
the control signals that facilitate the transfer of information from EEPROM to the switch. Data transfer is 8-bit
serial and bidirectional, at 50 Kbps. Data transfer is performed between master and slave IC using a request /
acknowledgment style of protocol. The master IC generates the timing signals and terminates data transfer.
Figure 2 depicts the data transfer format.
START SLAVE ADDRESS R/W ACK DATA 1 (8 bits) ACK DATA 2 ACK
DATA M
ACK STOP
Figure 2 - Data Transfer Format for I2C Interface
2.2.1
Start Condition
Generated by the master (in our case, the MVTX2603AG). The bus is considered to be busy after the Start
condition is generated. The Start condition occurs if while the SCL line is High, there is a High-to-Low transition
of the SDA line.
Other than in the Start condition (and Stop condition), the data on the SDA line must be stable during the High
period of SCL. The High or Low state of SDA can only change when SCL is Low. In addition, when the I2C bus
is free, both lines are High.
12
Zarlink Semiconductor Inc.
Data Sheet
2.2.2 Address
MVTX2603
The first byte after the Start condition determines which slave the master will select. The slave in our case is the
EEPROM. The first seven bits of the first data byte make up the slave address.
2.2.3
Data Direction
The eighth bit in the first byte after the Start condition determines the direction (R/W) of the message. A master
transmitter sets this bit to W; a master receiver sets this bit to R.
2.2.4
Acknowledgment
Like all clock pulses, the acknowledgment-related clock pulse is generated by the master. However, the
transmitter releases the SDA line (High) during the acknowledgment clock pulse. Furthermore, the receiver
must pull down the SDA line during the acknowledge pulse so that it remains stable Low during the High period
of this clock pulse. An acknowledgment pulse follows every byte transfer.
If a slave receiver does not acknowledge after any byte, then the master generates a Stop condition and aborts
the transfer.
If a master receiver does not acknowledge after any byte, then the slave transmitter must release the SDA line
to let the master generate the Stop condition.
2.2.5
Data
After the first byte containing the address, all bytes that follow are data bytes. Each byte must be followed by an
acknowledge bit. Data is transferred MSB first.
2.2.6
Stop Condition
Generated by the master. The bus is considered to be free after the Stop condition is generated. The Stop
condition occurs if while the SCL line is High, there is a Low-to-High transition of the SDA line.
The I2C interface serves the function of configuring the MVTX2603AG at boot time. The master is the
MVTX2603AG, and the slave is the EEPROM memory.
2.3
Synchronous Serial Interface
The synchronous serial interface serves the function of configuring the MVTX2603AG not at boot time but via a
PC. The PC serves as master and the MVTX2603AG serves as slave. The protocol for the synchronous serial
interface is nearly identical to the I2C protocol. The main difference is that there is no acknowledgment bit after
each byte of data transferred.
The unmanaged MVTX2603AG uses a synchronous serial interface to program the internal registers. To reduce
the number of signals required, the register address, command and data are shifted in serially through the D0
pin. STROBE- pin is used as the shift clock. AUTOFD- pin is used as data return path.
Each command consists of four parts.
START pulse
Register Address
Read or Write command
Data to be written or read back
Any command can be aborted in the middle by sending a ABORT pulse to the MVTX2603AG.
A START command is detected when D0 is sampled high when STROBE- rise and D0 is sampled low when
STROBE- fall.
Zarlink Semiconductor Inc.
13
MVTX2603
Data Sheet
An ABORT command is detected when D0 is sampled low when STROBE- rise and D0 is sampled high when
STROBE- fall.
2.3.1
Write Command
STROBE-
2 extra clock cycles
after last transfer
transfer
D0 D1 D2 D3 D4 D5 D6 D7
D0
A
0
A
1
A2 ... A9 A10 A11 W
START
ADDRESS
COMMAND DATA
Figure 3 - Write Command
2.3.2
Read Command
STROBE-
R
0
A10 A11
A0 A1 A2 ...
A
9
D0
START
AUTOFD-
ADDRESS
COMMAND
DATA
D4
D0
D
1
D2 D3 D4 D5 D6 D7
Figure 4 - Read Command
All registers in MVTX2603AG can be modified through this synchronous serial interface.
2.4 Stacking
The two Gigabits ports can be used as link between boxes. Each Gigabit port can be accelerated to 2 Gpbs if
desired (in conjunction with ZBT memory domains at 125MHz). If both Gigabit ports are used for this purpose,
this provides a total of 4 Gbps of bandwidth between devices.
3.0
3.1
MVTX2603AG Data Forwarding Protocol
Unicast Data Frame Forwarding
When a frame arrives, it is assigned a handle in memory by the Frame Control Buffer Manager (FCB Manager).
An FCB handle will always be available, because of advance buffer reservations.
The memory (SRAM) interface consists of two 64-bit buses, connected to two SRAM banks, A and B. The
Receive DMA (RxDMA) is responsible for multiplexing the data and the address. On a port’s “turn,” the RxDMA
will move 8 bytes (or up to the end-of-frame) from the port’s associated RxFIFO into memory (Frame Data
Buffer, or FDB).
Once an entire frame has been moved to the FDB, and a good end-of-frame (EOF) has been received, the Rx
interface makes a switch request. The RxDMA arbitrates among multiple switch requests.
14
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
The switch request consists of the first 64 bytes of a frame, containing among other things, the source and
destination MAC addresses of the frame. The search engine places a switch response in the switch response
queue of the frame engine when done. Among other information, the search engine will have resolved the
destination port of the frame and will have determined that the frame is unicast.
After processing the switch response, the Transmission Queue Manager (TxQ manager) of the frame engine is
responsible for notifying the destination port that it has a frame to forward to it. But first, the TxQ manager has
to decide whether or not to drop the frame, based on global FDB reservations and usage, as well as TxQ
occupancy at the destination. If the frame is not dropped, then the TxQ manager links the frame’s FCB to the
correct per-port-per-class TxQ. Unicast TxQ’s are linked lists of transmission jobs, represented by their
associated frames’ FCB’s. There is one linked list for each transmission class for each port. There are 4
transmission classes for each of the 24 10/100 ports, and 8 classes for each of the two Gigabit ports – a total of
112 unicast queues.
The TxQ manager is responsible for scheduling transmission among the queues representing different classes
for a port. When the port control module determines that there is room in the MAC Transmission FIFO (TxFIFO)
for another frame, it requests the handle of a new frame from the TxQ manager. The TxQ manager chooses
among the head-of-line (HOL) frames from the per-class queues for that port, using a Zarlink Semiconductor
scheduling algorithm.
The Transmission DMA (TxDMA) is responsible for multiplexing the data and the address. On a port’s turn, the
TxDMA will move 8 bytes (or up to the EOF) from memory into the port’s associated TxFIFO. After reading the
EOF, the port control requests a FCB release for that frame. The TxDMA arbitrates among multiple buffer
release requests.
The frame is transmitted from the TxFIFO to the line.
3.2
Multicast Data Frame Forwarding
After receiving the switch response, the TxQ manager has to make the dropping decision. A global decision to
drop can be made, based on global FDB utilization and reservations. If so, then the FCB is released and the
frame is dropped. In addition, a selective decision to drop can be made, based on the TxQ occupancy at some
subset of the multicast packet’s destinations. If so, then the frame is dropped at some destinations but not
others, and the FCB is not released.
If the frame is not dropped at a particular destination port, then the TxQ manager formats an entry in the
multicast queue for that port and class. Multicast queues are physical queues (unlike the linked lists for unicast
frames). There are 2 multicast queues for each of the 24 10/100 ports. The queue with higher priority has room
for 32 entries and the queue with lower priority has room for 64 entries. There are 4 multicast queues for each
of the two Gigabit ports. The sizes of the queues are: 32 entries (higher priority queue, 32 entries, 32 entries
and 64 entries (lower priority queue). There is one multicast queue for every two priority classes. For the 10/100
ports to map the 8 transmit priorities into 2 multicast queues, the 2 LSB are discarded. For the gigabit ports to
map the 8 transmit priorities into 4 multicast queues, the LSB are discarded.
During scheduling, the TxQ manager treats the unicast queue and the multicast queue of the same class as one
logical queue. The older head of line of the two queues is forwarded first.
The port control requests a FCB release only after the EOF for the multicast frame has been read by all ports to
which the frame is destined.
Zarlink Semiconductor Inc.
15
MVTX2603
Data Sheet
4.0
4.1
Memory Interface
Overview
The MVTX2603AG provides two 64-bit wide SRAM banks, SRAM Bank A and SRAM Bank B, with a 64-bit bus
connected to each. Each DMA can read and write from both bank A and bank B. The following figure provides
an overview of the MVTX2603AG SRAM banks.
SRAM Bank A
SRAM Bank B
TXDMA
16-23
TXDMA
0-7
TXDMA
8-15
RXDMA
0-7
RXDMA
8-15
RXDMA
16-23
Figure 5 - MVTX2603AG SRAM Interface Block Diagram (DMAs for 10/1000 Ports Only)
ZBT Support
4.2
The MVTX2603AG supports Zero Bus Turnaround (ZBT). ZBT is a synchronous SRAM architecture that is
optimized for networking and telecommunications applications. It can significantly increase the switch’s internal
bandwidth when compared to standard Pipeline SyncBurst SRAM.
The ZBT architecture is optimized for switching and other applications with highly random READs and WRITEs.
ZBT SRAMs eliminate all idle cycles when turning the data bus around from a WRITE operation to a READ
operation (or vice versa). This feature results in dramatic performance improvements in systems that have such
traffic patterns (that is, frequent and random read and write access to the SRAM).
Please refer to the ZBT Application note for further details.
4.3
Detailed Memory Information
Because the bus for each bank is 64 bits wide, frames are broken into 8-byte granules, written to and read from
memory. The first 8-byte granule gets written to Bank A, the second 8-byte granule gets written to Bank B, and
so on in alternating fashion. When reading frames from memory, the same procedure is followed, first from A,
then from B, and so on.
The reading and writing from alternating memory banks can be performed with minimal waste of memory
bandwidth. What’s the worst case? For any speed port, in the worst case, a 1-byte-long EOF granule gets
written to Bank A. This means that a 7-byte segment of Bank A bandwidth is idle, and furthermore, the next 8-
byte segment of Bank B bandwidth is idle, because the first 8 bytes of the next frame will be written to Bank A,
not B. This scenario results in a maximum 15 bytes of waste per frame, which is always acceptable because the
interframe gap is 20 bytes.
Search engine data is written to both banks in parallel. In this way, a search engine read operation can be
performed by either bank at any time without a problem.
16
Zarlink Semiconductor Inc.
Data Sheet
4.4 Memory Requirements
MVTX2603
To speed up searching and decrease memory latency, the external MCT database is duplicated in both
memory banks. To support 64K MCT, 4 MB memory is required. Up to 2K frame buffers are supported and they
will use 3 MB of memory. The maximum system memory requirement is 4 MB. If less memory is desired, the
configuration can scale down proportionally.
Bank A
Bank B
Frame Buffer
Max MAC Address
32K
64k
1M
2M
1M
2M
1K
2K
Table 1 - Memory Configuration
1M Bank A
1M Bank B 2M Bank A 2M Bank B
0.75M
0.25M
0.75M
0.25M
1.5M
0.5M
1.5M
0.5M
Frame Data Buffer (FDR) Area
MAC Address Control Table (MCT) Area
Figure 6 - Memory Map
5.0
5.1
Search Engine
Search Engine Overview
The MVTX2603AG search engine is optimized for high throughput searching, with enhanced features to
support:
•
•
•
•
•
•
Up to 64K MAC addresses
3 groups of port trunking (1 for the two Gigabit ports, and 2 others)
Traffic classification into 4 (or 8 for Gigabit) transmission priorities, and 2 drop precedence levels
Flooding, Broadcast, Multicast Storm Control
MAC address learning and aging
Port based VLAN
5.2
Basic Flow
Shortly after a frame enters the MVTX2603AG and is written to the Frame Data Buffer (FDB), the frame engine
generates a Switch Request, which is sent to the search engine. The switch request consists of the first 64
bytes of the frame, which contain all the necessary information for the search engine to perform its task. When
the search engine is done, it writes to the Switch Response Queue, and the frame engine uses the information
provided in that queue for scheduling and forwarding.
In performing its task, the search engine extracts and compresses the useful information from the 64-byte
switch request. Among the information extracted are the source and destination MAC addresses, the
transmission and discard priorities, whether the frame is unicast or multicast. Requests are sent to the external
SRAM to locate the associated entries in the external hash table.
Zarlink Semiconductor Inc.
17
MVTX2603
Data Sheet
When all the information has been collected from external SRAM, the search engine has to compare the MAC
address on the current entry with the MAC address for which it is searching. If it is not a match, the process is
repeated on the internal MCT Table. All MCT entries other than the first of each linked list are maintained
internal to the chip. If the desired MAC address is still not found, then the result is either learning (source MAC
address unknown) or flooding (destination MAC address unknown).
In addition, port based VLAN information is used to select the correct set of destination ports for the frame (for
multicast), or to verify that the frame’s destination port is associated with the VLAN (for unicast).
If the destination MAC address belongs to a port trunk, then the trunk number is retrieved instead of the port
number. But on which port of the trunk will the frame be transmitted? This is easily computed using a hash of
the source and destination MAC addresses.
When all the information is compiled, the switch response is generated, as stated earlier.
5.3
Search, Learning, and Aging
MAC Search
5.3.1
The search block performs source MAC address and destination MAC address searching. As we indicated
earlier, if a match is not found, then the next entry in the linked list must be examined, and so on until a match is
found or the end of the list is reached.
The port based VLAN bitmap is used to determine whether the frame should be forwarded to the outgoing port.
When the egress port is not included in the ingress port VLAN bitmap, the packet is discarded.
The MAC search block is also responsible for updating the source MAC address timestamp and the VLAN port
association timestamp, used for aging.
5.3.2
Learning
The learning module learns new MAC addresses and performs port change operations on the MCT database.
The goal of learning is to update this database as the networking environment changes over time. Learning and
port change will be performed based on memory slot availability only.
5.3.3
Aging
Aging time is controlled by register 400h and 401h.
The aging module scans and ages MCT entries based on a programmable “age out” time interval. As we
indicated earlier, the search module updates the source MAC address timestamps for each frame it processes.
When an entry is ready to be aged, the entry is removed from the table.
5.4
Quality of Service
Quality of Service (QoS) refers to the ability of a network to provide better service to selected network traffic
over various technologies. Primary goals of QoS include dedicated bandwidth, controlled jitter and latency
(required by some real-time and interactive traffic), and improved loss characteristics.
Traditional Ethernet networks have had no prioritization of traffic. Without a protocol to prioritize or differentiate
traffic, a service level known as “best effort” attempts to get all the packets to their intended destinations with
minimum delay; however, there are no guarantees. In a congested network or when a low-performance
switch/router is overloaded, “best effort” becomes unsuitable for delay-sensitive traffic and mission-critical data
transmission.
The advent of QoS for packet-based systems accommodates the integration of delay-sensitive video and
multimedia traffic onto any existing Ethernet network. It also alleviates the congestion issues that have
previously plagued such “best effort” networking systems. QoS provides Ethernet networks with the
breakthrough technology to prioritize traffic and ensure that a certain transmission will have a guaranteed
minimum amount of bandwidth.
18
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Extensive core QoS mechanisms are built into the MVTX2603AG architecture to ensure policy enforcement and
buffering of the ingress port, as well as weighted fair-queue (WFQ) scheduling at the egress port.
In the MVTX2603AG, QoS-based policies sort traffic into a small number of classes and mark the packets
accordingly. The QoS identifier provides specific treatment to traffic in different classes, so that different quality
of service is provided to each class. Frame and packet scheduling and discarding policies are determined by
the class to which the frames and packets belong. For example, the overall service given to frames and packets
in the premium class will be better than that given to the standard class; the premium class is expected to
experience lower loss rate or delay.
The MVTX2603AG supports the following QoS techniques:
•
•
•
In a port-based setup, any station connected to the same physical port of the switch will have the same
transmit priority.
In a tag-based setup, a 3-bit field in the VLAN tag provides the priority of the packet. This priority can be
mapped to different queues in the switch to provide QoS.
In a TOS/DS-based set up, TOS stands for “Type of Service” that may include “minimize delay,” “maximize
throughput,” or “maximize reliability.” Network nodes may select routing paths or forwarding behaviours that
are suitably engineered to satisfy the service request.
•
In a logical port-based set up, a logical port provides the application information of the packet. Certain
applications are more sensitive to delays than others; using logical ports to classify packets can help speed
up delay sensitive applications, such as VoIP.
5.5
Priority Classification Rule
Figure 7 on page 19 shows the MVTX2603AG priority classification rule
Yes
Use Default Port Settings
Fix Port Priority ?
No
Yes
TOS Precedence over VLAN?
(FCR Register, Bit 7)
Use Default Port Settings
No
No
No
No
IP Frame ?
IP
VLAN Tag ?
Yes
Yes
Use Logical Port
Yes
Use Logical Port
Yes
No
Use TOS
Use VLAN Priority
Figure 7 - Priority Classification Rule
Zarlink Semiconductor Inc.
19
MVTX2603
Data Sheet
5.6
Port Based VLAN
An administrator can use the PVMAP Registers to configure the MVTX2603AG for port-based VLAN. For
example, ports 1-3 might be assigned to the Marketing VLAN, ports 4-6 to the Engineering VLAN, and ports 7-9
to the Administrative VLAN. The MVTX2603AG determines the VLAN membership of each packet by noting the
port on which it arrives. From there, the MVTX2603AG determines which outgoing port(s) is/are eligible to
transmit each packet, or whether the packet should be discarded.
Destination Port Numbers Bit Map
Port Registers
26
0
…
2
1
1
1
0
0
Register for Port #0
PVMAP00_0[7:0] to PVMAP00_3[2:0]
Register for Port #1
0
0
1
0
0
0
1
0
PVMAP01_0[7:0] to PVMAP01_3[2:0]
Register for Port #2
PVMAP02_0[7:0] to PVMAP02_3[2:0]
…
Register for Port #26
0
0
0
0
PVMAP26_0[7:0] to PVMAP26_3[2:0]
Table 2 - PVMAP Register
For example, in the above table, a 1 denotes that an outgoing port is eligible to receive a packet from an
incoming port. A 0 (zero) denotes that an outgoing port is not eligible to receive a packet from an incoming port.
In this example
•
•
•
Data packets received at port #0 are eligible to be sent to outgoing ports 1 and 2
Data packets received at port #1 are eligible to be sent to outgoing ports 0, and 2
Data packets received at port #2 are not eligible to be sent to ports 0 and 1
5.7
Memory Configurations
The MVTX2603AG supports the following memory configurations. SBRAM modes support 1M and 2M
configurations, while ZBT mode supports 4M configurations, 2M per domain (bank). For detail connection
information, please reference the memory application note.
1 M per bank
(Bootstrap pin
2 M per bank
(Bootstrap pin
Configuration
Connections
TSTOUT7 = open)
TSTOUT7 = pull down)
Single Layer
Two 128K x 32
Two 256K x 32
SRAM/bank
Connect 0E# and WE#
(Bootstrap pin
SRAM/bank or
TSTOUT13 = open)
One 128 K x 64 SRAM/bank
Double Layer
NA
Four 128K x 32
SRAM/bank or
Connect 0E0# and
(Bootstrap pin
WE0# Connect 0E1#
TSTOUT13 = pull down)
Two 128 K x 64 SRAM/bank and WE1#
Table 3 - Supported Memory Configurations (Pipeline SBRAM Mode)
20
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Configuration
2 M per bank
Connections
Connect ADS# to Layer 0 chipselect
Single Layer
Two 256 K x 32 ZBT SRAM/bank
(Bootstrap pin
or One 256 K x 64 ZBT SRAM/bank pin
TSTOUT13 = open)
Double Layer
Four 128 K x 32 ZBT SRAM/bank
Connect ADS# to Layer 0 chipselect
(Bootstrap pin
or Two 128 K x 64 ZBT SRAM/bank pin
TSTOUT13 = pull down)
and 0E# to Layer 1 chipselect pin
Table 4 - Supported Memory Configurations (ZBT Mode)
Frame data Buffer
Only Bank A
1M 2M
Bank A and Bank B
1M/bank 2M/bank
Bank A and Bank B
1M/bank 2M/bank
(SRAM) (SRAM) (SRAM)
(SRAM) (ZBT SRAM) (ZBT SRAM)
MVTX2601
MVTX2602
MVTX2603
X
X
X
X
X
X
X
X
X
X
MVTX2603
X (125Mhz)
X (125Mhz)
(Gigabit ports in 2giga mode)
MVTX2604
X
X
MVTX2604
X (125Mhz)
X (125Mhz)
(Gigabit ports in 2giga mode)
Table 5 - Options for Memory Configuration
Bank B (1M One Layer)
Bank A (1M One Layer)
Data LB_D[63:32]
Data LA_D[63:32]
Data LA_D[31:0]
SRAM
Data LB_D[31:0]
SRAM
Memory
128K
Memory
128K
32 bits
Memory
128K
32 bits
Memory
128K
32 bits
32 bits
Address LB_A[19:3]
Address LA_A[19:3]
Zarlink Semiconductor Inc.
21
MVTX2603
Data Sheet
Figure 8 - Memory Configuration For: 2 banks, 1 layer, 2MB total
BANK A (2M Two Layers)
BANK B (2M Two Layers)
Data LA_D[63:32]
Data LB_D[63:32]
Data LA_D[31:0]
Data LB_D[31:0]
SRAM
Memory
128 K
SRAM
Memory
128 K
SRAM
Memory
128 K
SRAM
Memory
128 K
32 bits
32 bits
32 bits
32 bits
SRAM
Memory
128 K
SRAM
Memory
128 K
SRAM
Memory
128 K
SRAM
Memory
128 K
32 bits
32 bits
32 bits
32 bits
Address LA_A[19:3]
Address LB_A[19:3]
Bootstraps: TSTOUT7 = Pull Down, TSTOUT13 = Pull Down, TSTOUT4 = Open
Figure 9 - Memory Configuration For: 2 banks, 2 Layer, 4MB total
BANK A (2M One Layer)
BANK B (2M One Layer)
Data LA_D[63:32]
Data LB_D[63:32]
Data LA_D[31:0]
Data LB_D[31:0]
SRAM
Memory
256 K
SRAM
Memory
256 K
Memory
256 K
Memory
256 K
32 bits
32 bits
32 bits
32 bits
Address LA_A[20:3]
Address LB_A[20:3]
Bootstraps: TSTOUT7 = Pull Down, TSTOUT13 = Open, TSTOUT4 = Open
Figure 10 - Memory Configuration For: 2 banks, 1 layer, 4MB
22
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
BANK A (2M Two Layers)
BANK B (2M Two Layers)
Data LA_D[63:32]
Data LB_D[63:32]
Data LA_D[31:0]
Data LB_D[31:0]
ZBT
ZBT
ZBT
ZBT
Memory
128 K
32 bits
Memory
128 K
32 bits
Memory
128 K
32 bits
Memory
128 K
32 bits
ZBT
ZBT
ZBT
ZBT
Memory
128 K
32 bits
Memory
128 K
32 bits
Memory
128 K
32 bits
Memory
128 K
32 bits
Address LA_A[19:3]
Address LB_A[19:3]
Figure 11 - Memory Configuration For: 2 banks, 2 layers, 4MB total
BANK A (2M One Layer)
BANK B (2M One Layer)
Data LA_D[63:32]
Data LB_D[63:32]
Data LA_D[31:0]
Data LB_D[31:0]
ZBT
ZBT
ZBT
ZBT
Memory
256 K
32 bits
Memory
256 K
32 bits
Memory
256 K
32 bits
Memory
256 K
32 bits
Address LA_A[20:3]
Address LB_A[20:3]
Bootstraps: TSTOUT7 = Pull Down, TSTOUT13 = Open, TSTOUT4 = Pull Down
Figure 12 - Memory Configuration For: 2 banks, 1 layer, 4MB
Zarlink Semiconductor Inc.
23
MVTX2603
Data Sheet
6.0
6.1
Frame Engine
Data Forwarding Summary
•
When a frame enters the device at the RxMAC, the RxDMA will move the data from the MAC RxFIFO to the
FDB. Data is moved in 8-byte granules in conjunction with the scheme for the SRAM interface.
•
•
A switch request is sent to the Search Engine. The Search Engine processes the switch request.
A switch response is sent back to the Frame Engine and indicates whether the frame is unicast or multicast,
and its destination port or ports.
•
A Transmission Scheduling Request is sent in the form of a signal notifying the TxQ manager. Upon
receiving a Transmission Scheduling Request, the device will format an entry in the appropriate
Transmission Scheduling Queue (TxSch Q) or Queues. There are 4 TxSch Q for each 10/100 port (and 8
per Gigabit port), one for each priority. Creation of a queue entry either involves linking a new job to the
appropriate linked list if unicast, or adding an entry to a physical queue if multicast.
•
When the port is ready to accept the next frame, the TxQ manager will get the head-of-line (HOL) entry of
one of the TxSch Qs, according to the transmission scheduling algorithm (to ensure per-class quality of
service). The unicast linked list and the multicast queue for the same port-class pair are treated as one
logical queue. The older HOL between the two queues goes first. For 10/100 ports multicast queue 0 is
associated with unicast queue 0 and multicast queue 1 is associated with unicast queue 2. For Gigabit ports
multicast queue 0 is associated with unicast queue 0, multicast queue 1 with unicast queue 2, multicast
queue 2 with unicast queue 4 and multicast queue 3 with unicast queue 6.
•
The TxDMA will pull frame data from the memory and forward it granule-by-granule to the MAC TxFIFO of
the destination port.
6.2
Frame Engine Details
This section briefly describes the functions of each of the modules of the MVTX2603AG frame engine.
6.2.1 FCB Manager
The FCB manager allocates FCB handles to incoming frames, and releases FCB handles upon frame
departure. The FCB manager is also responsible for enforcing buffer reservations and limits. The default values
can be determined by referring to Chapter 8. In addition, the FCB manager is responsible for buffer aging, and
for linking unicast forwarding jobs to their correct TxSch Q. The buffer aging can be enabled or disabled by the
bootstrap pin and the aging time is defined in register FCBAT.
6.2.2
Rx Interface
The Rx interface is mainly responsible for communicating with the RxMAC. It keeps track of the start and end of
frame and frame status (good or bad). Upon receiving an end of frame that is good, the Rx interface makes a
switch request.
6.2.3
RxDMA
The RxDMA arbitrates among switch requests from each Rx interface. It also buffers the first 64 bytes of each
frame for use by the search engine when the switch request has been made.
6.2.4
TxQ Manager
First, the TxQ manager checks the per-class queue status and global reserved resource situation, and using
this information, makes the frame dropping decision after receiving a switch response. If the decision is not to
drop, the TxQ manager requests that the FCB manager link the unicast frame’s FCB to the correct per-port-per-
class TxQ. If multicast, the TxQ manager writes to the multicast queue for that port and class. The TxQ
manager can also trigger source port flow control for the incoming frame’s source if that port is flow control
enabled. Second, the TxQ manager handles transmission scheduling; it schedules transmission among the
queues representing different classes for a port. Once a frame has been scheduled, the TxQ manager reads
the FCB information and writes to the correct port control module.
24
Zarlink Semiconductor Inc.
Data Sheet
6.3 Port Control
MVTX2603
The port control module calculates the SRAM read address for the frame currently being transmitted. It also
writes start of frame information and an end of frame flag to the MAC TxFIFO. When transmission is done, the
port control module requests that the buffer be released.
6.4
TxDMA
The TxDMA multiplexes data and address from port control, and arbitrates among buffer release requests from
the port control modules.
7.0
7.1
Quality of Service and Flow Control
Model
Quality of service is an all-encompassing term for which different people have different interpretations. In
general, the approach to quality of service described here assumes that we do not know the offered traffic
pattern. We also assume that the incoming traffic is not policed or shaped. Furthermore, we assume that the
network manager knows his applications, such as voice, file transfer, or web browsing, and their relative
importance. The manager can then subdivide the applications into classes and set up a service contract with
each. The contract may consist of bandwidth or latency assurances per class. Sometimes it may even reflect an
estimate of the traffic mix offered to the switch. As an added bonus, although we do not assume anything about
the arrival pattern, if the incoming traffic is policed or shaped, we may be able to provide additional assurances
about our switch’s performance.
Table 6 on page 25 shows examples of QoS applications with three transmission priorities, but best effort (P0)
traffic may form a fourth class with no bandwidth or latency assurances. Gigabit ports actually have eight total
transmission priorities.
Total
Low Drop Probability
(low-drop)
High Drop Probability
(high-drop)
Goals
Assured Bandwidth
(user defined)
Highest transmission 50 Mbps
priority, P3
Apps: phone calls, circuit
emulation.
Apps: training video.
Latency: < 1 ms.
Latency: < 1 ms.
Drop: No drop if P3 not
oversubscribed.
Drop: No drop if P3 not
oversubscribed; first P3 to
drop otherwise.
Middle transmission
priority, P2
37.5 Mbps
12.5 Mbps
100 Mbps
Apps: interactive apps, Web
business.
Apps: non-critical interactive
apps.
Latency: < 4-5 ms.
Drop: No drop if P2 not
oversubscribed.
Latency: < 4-5 ms.
Drop: No drop if P2 not
oversubscribed; firstP2 to
drop otherwise.
Low transmission
priority, P1
Apps: emails, file backups.
Latency: < 16 ms desired, but
not critical.
Apps: casual web browsing.
Latency: < 16 ms desired, but
not critical.
Drop: No drop if P1 not
oversubscribed.
Drop: No drop if P1 not
oversubscribed; first to drop
otherwise.
Total
Table 6 - Two-dimensional World Traffic
Zarlink Semiconductor Inc.
25
MVTX2603
Data Sheet
A class is capable of offering traffic that exceeds the contracted bandwidth. A well-behaved class offers traffic at
a rate no greater than the agreed-upon rate. By contrast, a misbehaving class offers traffic that exceeds the
agreed-upon rate. A misbehaving class is formed from an aggregation of misbehaving microflows. To achieve
high link utilization, a misbehaving class is allowed to use any idle bandwidth. However, such leniency must not
degrade the quality of service (QoS) received by well-behaved classes.
As Table 6 illustrates, the six traffic types may each have their own distinct properties and applications. As
shown, classes may receive bandwidth assurances or latency bounds. In the table, P3, the highest transmission
class, requires that all frames be transmitted within 1 ms, and receives 50% of the 100 Mbps of bandwidth at
that port.
Best-effort (P0) traffic forms a fourth class that only receives bandwidth when none of the other classes have
any traffic to offer. It is also possible to add a fourth class that has strict priority over the other three; if this class
has even one frame to transmit, then it goes first. In the MVTX2603AG, each 10/100 Mbps port will support four
total classes, and each 1000 Mbps port will support eight classes. We will discuss the various modes of
scheduling these classes in the next section.
In addition, each transmission class has two subclasses, high-drop and low-drop. Well-behaved users should
rarely lose packets. But poorly behaved users – users who send frames at too high a rate – will encounter frame
loss, and the first to be discarded will be high-drop. Of course, if this is insufficient to resolve the congestion,
eventually some low-drop frames are dropped, and then all frames in the worst case.
Table 6 shows that different types of applications may be placed in different boxes in the traffic table. For
example, casual web browsing fits into the category of high-loss, high-latency-tolerant traffic, whereas VoIP fits
into the category of low-loss, low-latency traffic.
7.2
Four QoS Configurations
There are four basic pieces to QoS scheduling in the MVTX2603AG: strict priority (SP), delay bound, weighted
fair queuing (WFQ), and best effort (BE). Using these four pieces, there are four different modes of operation,
as shown in Table 4, “Supported Memory Configurations (ZBT Mode),” and Table 6, “Two-dimensional World
Traffic,” . For 10/100 Mbps ports, these modes are selected by the following registers:
QOSC24 [7:6]
QOSC28 [7:6]
QOSC32 [7:6]
QOSC36 [7:6]
CREDIT_C00
CREDIT_C10
CREDIT_C20
CREDIT_C30
P3
P2
P1
P0
Op1 (default)
Op2
Delay Bound
BE
BE
SP
Delay Bound
WFQ
Op3
SP
Op4
WFQ
Table 7 - Four QoS Configurations for a 10/100 Mbps Port
26
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
These modes are selected by QOSC40 [7:6] and QOSC48 [7:6] for the first and second gigabit ports, respectively.
P7
P6
P5
P4
P3
P2
P1
BE
BE
P0
Op1 (default)
Op2
Delay Bound
SP
Delay Bound
WFQ
Op3
SP
Op4
WFQ
Table 8 - Four QoS Configurations for a Gigabit Port
The default configuration for a 10/100 Mbps port is three delay-bounded queues and one best-effort queue. The
delay bounds per class are 0.8 ms for P3, 2 ms for P2, and 12.8 ms for P1. For a 1 Gbps port, we have a default
of six delay-bounded queues and two best-effort queues. The delay bounds for a 1 Gbps port are 0.16 ms for
P7 and P6, 0.32 ms for P5, 0.64 ms for P4, 1.28 ms for P3, and 2.56 ms for P2. Best effort traffic is only served
when there is no delay-bounded traffic to be served. For a 1 Gbps port, where there are two best-effort queues,
P1 has strict priority over P0.
We have a second configuration for a 10/100 Mbps port in which there is one strict priority queue, two delay
bounded queues, and one best effort queue. The delay bounds per class are 3.2 ms for P2 and 12.8 ms for P1.
If the user is to choose this configuration, it is important that P3 (SP) traffic be either policed or implicitly
bounded (e.g. if the incoming P3 traffic is very light and predictably patterned). Strict priority traffic, if not
admission-controlled at a prior stage to the MVTX2603AG, can have an adverse effect on all other classes’
performance. For a 1 Gbps port, P7 and P6 are both SP classes, and P7 has strict priority over P6. In this case,
the delay bounds per class are 0.32 ms for P5, 0.64 ms for P4, 1.28 ms for P3, and 2.56 ms for P2.
The third configuration for a 10/100 Mbps port contains one strict priority queue and three queues receiving a
bandwidth partition via WFQ. As in the second configuration, strict priority traffic needs to be carefully
controlled. In the fourth configuration, all queues are served using a WFQ service discipline.
7.3
Delay Bound
In the absence of a sophisticated QoS server and signaling protocol, the MVTX2603AG may not know the mix
of incoming traffic ahead of time. To cope with this uncertainty, our delay assurance algorithm dynamically
adjusts its scheduling and dropping criteria, guided by the queue occupancies and the due dates of their head-
of-line (HOL) frames. As a result, we assure latency bounds for all admitted frames with high confidence, even
in the presence of system-wide congestion. Our algorithm identifies misbehaving classes and intelligently
discards frames at no detriment to well-behaved classes. Our algorithm also differentiates between high-drop
and low-drop traffic with a weighted random early drop (WRED) approach. Random early dropping prevents
congestion by randomly dropping a percentage of high-drop frames even before the chip’s buffers are
completely full, while still largely sparing low-drop frames. This allows high-drop frames to be discarded early,
as a sacrifice for future low-drop frames. Finally, the delay bound algorithm also achieves bandwidth partitioning
among classes.
7.4
Strict Priority and Best Effort
When strict priority is part of the scheduling algorithm, if a queue has even one frame to transmit, it goes first.
Two of our four QoS configurations include strict priority queues. The goal is for strict priority classes to be used
for IETF expedited forwarding (EF), where performance guarantees are required. As we have indicated, it is
important that strict priority traffic be either policed or implicitly bounded, so as to keep from harming other
traffic classes.
When best effort is part of the scheduling algorithm, a queue only receives bandwidth when none of the other
classes have any traffic to offer. Two of our four QoS configurations include best effort queues. The goal is for
best effort classes to be used for non-essential traffic, because we provide no assurances about best effort
Zarlink Semiconductor Inc.
27
MVTX2603
Data Sheet
performance. However, in a typical network setting, much best effort traffic will indeed be transmitted, and with
an adequate degree of expediency.
Because we do not provide any delay assurances for best effort traffic, we do not enforce latency by dropping
best effort traffic. Furthermore, because we assume that strict priority traffic is carefully controlled before
entering the MVTX2603AG, we do not enforce a fair bandwidth partition by dropping strict priority traffic. To
summarize, dropping to enforce bandwidth or delay does not apply to strict priority or best effort queues. We
only drop frames from best effort and strict priority queues when global buffer resources become scarce.
7.5
Weighted Fair Queuing
In some environments – for example, in an environment in which delay assurances are not required, but precise
bandwidth partitioning on small time scales is essential, WFQ may be preferable to a delay-bounded scheduling
discipline. The MVTX2603AG provides the user with a WFQ option with the understanding that delay
assurances can not be provided if the incoming traffic pattern is uncontrolled. The user sets four WFQ “weights”
(eight for Gigabit ports) such that all weights are whole numbers and sum to 64. This provides per-class
bandwidth partitioning with error within 2%.
In WFQ mode, though we do not assure frame latency, the MVTX2603AG still retains a set of dropping rules
that helps to prevent congestion and trigger higher level protocol end-to-end flow control.
As before, when strict priority is combined with WFQ, we do not have special dropping rules for the strict priority
queues, because the input traffic pattern is assumed to be carefully controlled at a prior stage. However, we do
indeed drop frames from SP queues for global buffer management purposes. In addition, queue P0 for a 10/100
port (and queues P0 and P1 for a Gigabit port) are treated as best effort from a dropping perspective, though
they still are assured a percentage of bandwidth from a WFQ scheduling perspective. What this means is that
these particular queues are only affected by dropping when the global buffer count becomes low.
7.6
Shaper
Although traffic shaping is not a primary function of the MVTX2603AG, the chip does implement a shaper for
expedited forwarding (EF). Our goal in shaping is to control the peak and average rate of traffic exiting the
MVTX2603AG. Shaping is limited to the two Gigabit ports only, and only to class P6 (the second highest
priority). This means that class P6 will be the class used for EF traffic. If shaping is enabled for P6, then P6
traffic must be scheduled using strict priority. With reference to Table 8 only the middle two QoS configurations
may be used.
Peak rate is set using a programmable whole number, no greater than 64. For example, if the setting is 32, then
the peak rate for shaped traffic is 32/64 * 1000 Mbps = 500 Mbps. Average rate is also a programmable whole
number, no greater than 64, and no greater than the peak rate. For example, if the setting is 16, then the
average rate for shaped traffic is 16/64 * 1000 Mbps = 250 Mbps. As a consequence of the above settings in our
example, shaped traffic will exit the MVTX2603AG at a rate always less than 500 Mbps, and averaging no
greater than 250 Mbps. See Programming QoS Registers application note for more information.
Also, when shaping is enabled, it is possible for a P6 queue to explode in length if fed by a greedy source. The
reason is that a shaper is by definition not work-conserving; that is, it may hold back from sending a packet
even if the line is idle. Though we do have global resource management, we do nothing to prevent this situation
locally. We assume SP traffic is policed at a prior stage to the MVTX2603AG.
28
Zarlink Semiconductor Inc.
Data Sheet
7.7 WRED Drop Threshold Management Support
MVTX2603
To avoid congestion, the Weighted Random Early Detection (WRED) logic drops packets according to specified
parameters. The following table summarizes the behavior of the WRED logic.
Table 9 - WRED Drop Thresholds
Px is the total byte count, in the priority queue x. The WRED logic has three drop levels, depending on the value
of N, which is based on the number of bytes in the priority queues. If delay bound scheduling is used, N equals
P3*16+P2*4+P1. If using WFQ scheduling, N equals P3+P2+P1. Each drop level from one to three has defined
high-drop and low-drop percentages, which indicate the minimum and maximum percentages of the data that
can be discarded. The X, Y Z percent can be programmed by the register RDRC0, RDRC1. In Level 3, all
packets are dropped if the bytes in each priority queue exceed the threshold. Parameters A, B, C are the byte
count thresholds for each priority queue. They can be programmed by the QOS control register (refer to the
register group 5.)
7.8
Buffer Management
Because the number of FDB slots is a scarce resource, and because we want to ensure that one misbehaving
source port or class cannot harm the performance of a well-behaved source port or class, we introduce the
concept of buffer management into the MVTX2603AG. Our buffer management scheme is designed to divide
the total buffer space into numerous reserved regions and one shared pool, as shown in Figure 13 on page 30.
As shown in the figure, the FDB pool is divided into several parts. A reserved region for temporary frames
stores frames prior to receiving a switch response. Such a temporary region is necessary, because when the
frame first enters the MVTX2603AG, its destination port and class are as yet unknown, and so the decision to
drop or not needs to be temporarily postponed. This ensures that every frame can be received first before
subjecting them to the frame drop discipline after classifying.
Six reserved sections, one for each of the first six priority classes, ensure a programmable number of FDB slots
per class. The lowest two classes do not receive any buffer reservation. Furthermore, even for 10/100 Mbps
ports, a frame is stored in the region of the FDB corresponding to its class. As we have indicated, the eight
classes use only four transmission scheduling queues for 10/100 Mbps ports, but as far as buffer usage is
concerned, there are still eight distinguishable classes.
Another segment of the FDB reserves space for each of the 26 ports ethernet port. Two parameters can be set,
one for the source port reservation for 10/100 Mbps ports, and one for the source port reservation for 1 Gbps
ports. These 26 reserved regions make sure that no well-behaved source port can be blocked by another
misbehaving source port.
In addition, there is a shared pool, which can store any type of frame. The frame engine allocates the frames
first in the six priority sections. When the priority section is full or the packet has priority 1 or 0, the frame is
allocated in the shared poll. Once the shared poll is full the frames are allocated in the section reserved for the
source port.
Zarlink Semiconductor Inc.
29
MVTX2603
Data Sheet
The following registers define the size of each section of the frame data buffer:
PR100- Port Reservation for 10/100 Ports
PRG- Port Reservation for Giga Ports
SFCB- Share FCB Size
C2RS- Class 2 Reserve Size
C3RS- Class 3 Reserve Size
C4RS- Class 4 Reserve Size
C5RS- Class 5 Reserve Size
C6RS- Class 6 Reserve Size
C7RS- Class 7 Reserve Size
temporary
reservation
shared pool
S
per-class
reservation
per-source
reservations
per-source
reservations
(2G)
(24 10/100M, CPU)
Figure 13 - Buffer Partition Scheme Used to Implement MVTX2603AG Buffer Management
Dropping When Buffers Are Scarce
7.8.1
Summarizing the two examples of local dropping discussed earlier in this chapter:
•
If a queue is a delay-bounded queue, we have a multi-level WRED drop scheme, designed to control delay
and partition bandwidth in case of congestion.
•
If a queue is a WFQ-scheduled queue, we have a multi-level WRED drop scheme, designed to prevent
congestion.
In addition to these reasons for dropping, we also drop frames when global buffer space becomes scarce. The
function of buffer management is to make sure that such dropping causes as little blocking as possible.
30
Zarlink Semiconductor Inc.
Data Sheet
7.9 MVTX2603AG Flow Control Basics
MVTX2603
Because frame loss is unacceptable for some applications, the MVTX2603AG provides a flow control option.
When flow control is enabled, scarcity of buffer space in the switch may trigger a flow control signal; this signal
tells a source port that is sending a packet to this switch, to temporarily hold off.
While flow control offers the clear benefit of no packet loss, it also introduces a problem for quality of service.
When a source port receives an Ethernet flow control signal, all microflows originating at that port, well-behaved
or not, are halted. A single packet destined for a congested output can block other packets destined for
uncongested outputs. The resulting head-of-line blocking phenomenon means that quality of service cannot be
assured with high confidence when flow control is enabled.
In the MVTX2603AG, each source port can independently have flow control enabled or disabled. For flow
control enabled ports, by default all frames are treated as lowest priority during transmission scheduling. This is
done so that those frames are not exposed to the WRED Dropping scheme. Frames from flow control enabled
ports feed to only one queue at the destination, the queue of lowest priority. What this means is that if flow
control is enabled for a given source port, then we can guarantee that no packets originating from that port will
be lost, but at the possible expense of minimum bandwidth or maximum delay assurances. In addition, these
“downgraded” frames may only use the shared pool or the per-source reserved pool in the FDB; frames from
flow control enabled sources may not use reserved FDB slots for the highest six classes (P2-P7).
The MVTX2603AG does provide a system-wide option of permitting normal QoS scheduling (and buffer use) for
frames originating from flow control enabled ports. When this programmable option is active, it is possible that
some packets may be dropped, even though flow control is on. The reason is that intelligent packet dropping is
a major component of the MVTX2603AG’s approach to ensuring bounded delay and minimum bandwidth for
high priority flows.
7.9.1
Unicast Flow Control
For unicast frames, flow control is triggered by source port resource availability. Recall that the MVTX2603AG’s
buffer management scheme allocates a reserved number of FDB slots for each source port. If a programmed
number of a source port’s reserved FDB slots have been used, then flow control Xoff is triggered.
Xon is triggered when a port is currently being flow controlled, and all of that port’s reserved FDB slots have
been released.
Note that the MVTX2603AG’s per-source-port FDB reservations assure that a source port that sends a single
frame to a congested destination will not be flow controlled.
7.9.2
Multicast Flow Control
In unmanaged mode, flow control for multicast frames is triggered by a global buffer counter. When the system
exceeds a programmable threshold of multicast packets, Xoff is triggered. Xon is triggered when the system
returns below this threshold.
In managed mode, per-VLAN flow control is used for multicast frames. In this case, flow control is triggered by
congestion at the destination. How so? The MVTX2603AG checks each destination to which a multicast packet
is headed. For each destination port, the occupancy of the lowest-priority transmission multicast queue
(measured in number of frames) is compared against a programmable congestion threshold. If congestion is
detected at even one of the packet’s destinations, then Xoff is triggered.
In addition, each source port has a 26-bit port map recording which port or ports of the multicast frame’s fanout
were congested at the time Xoff was triggered. All ports are continuously monitored for congestion, and a port is
identified as uncongested when its queue occupancy falls below a fixed threshold. When all those ports that
were originally marked as congested in the port map have become uncongested, then Xon is triggered, and the
26-bit vector is reset to zero.
The MVTX2603AG also provides the option of disabling VLAN multicast flow control.
Zarlink Semiconductor Inc.
31
MVTX2603
Data Sheet
Note: If per-Port flow control is on, QoS performance will be affected. To determine the most efficient way to
program, please refer to the QoS Application Note.
7.10
Mapping to IETF Diffserv Classes
The mapping between priority classes discussed in this chapter and elsewhere is shown below.
P7
P6
EF
P5
P4
P3
P2
P1
P0
VTX
NM
AF0
AF1
AF2
AF3
BE0
BE1
IETF
Table 10 - Mapping between MVTX2603AG and IETF Diffserv Classes for Gigabit Ports
As the table illustrates, P7 is used solely for network management (NM) frames. P6 is used for expedited
forwarding service (EF). Classes P2 through P5 correspond to an assured forwarding (AF) group of size 4.
Finally, P0 and P1 are two best effort (BE) classes.
For 10/100 Mbps ports, the classes of Table 12 are merged in pairs—one class corresponding to NM+EF, two
AF classes, and a single BE class.
VTX
P3
P2
P1
P0
IETF
NM+EF
AF0
AF1
BE0
Table 11 - Mapping between MVTX2603AG and IETF Diffserv Classes for 10/100 Ports
Features of the MVTX2603AG that correspond to the requirements of their associated IETF classes are summarized
in the table below.
Network management (NM) and
Expedited forwarding (EF)
•
•
•
•
Global buffer reservation for NM and EF
Shaper for EF traffic on 1 Gbps ports
Option of strict priority scheduling
No dropping if admission controlled
Assured forwarding (AF)
•
•
•
Four AF classes for 1 Gbps ports
Programmable bandwidth partition, with option of WFQ service
Option of delay-bounded service keeps delay under fixed levels even
if not admission-controlled
•
•
Random early discard, with programmable levels
Global buffer reservation for each AF class
Best effort (BE)
•
•
Two BE classes for 1 Gbps ports
Service only when other queues are idle means that QoS not
adversely affected
Random early discard, with programmable levels
Traffic from flow control enabled ports automatically classified as BE
•
•
Table 12 - MVTX2603AG Features Enabling IETF Diffserv Standards
32
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
8.0
8.1
Port Trunking
Features and Restrictions
A port group (i.e. trunk) can include up to 4 physical ports, but all of the ports in a group must be in the same
MVTX2603AG.
The two Gigabit ports may also be trunked together. There are three trunk groups total, including the option to
trunk Gigabit ports.
Load distribution among the ports in a trunk for unicast is performed using hashing based on source MAC
address and destination MAC address. Three other options include source MAC address only, destination MAC
address only, and source port (in bidirectional ring mode only). Load distribution for multicast is performed
similarly.
If a VLAN includes any of the ports in a trunk group, all the ports in that trunk group should be in the same VLAN
member map.
The MVTX2603AG also provides a safe fail-over mode for port trunking automatically. If one of the ports in the
trunking group goes down, the MVTX2603AG will automatically redistribute the traffic over to the remaining
ports in the trunk.
8.2
Unicast Packet Forwarding
The search engine finds the destination MCT entry, and if the status field says that the destination port found
belongs to a trunk, then the group number is retrieved instead of the port number. In addition, if the source
address belongs to a trunk, then the source port’s trunk membership register is checked.
A hash key, based on some combination of the source and destination MAC addresses for the current packet, selects
the appropriate forwarding port.
8.3
Multicast Packet Forwarding
For multicast packet forwarding, the device must determine the proper set of ports from which to transmit the
packet based on the VLAN index and hash key.
Two functions are required in order to distribute multicast packets to the appropriate destination ports in a port
trunking environment.
Determining one forwarding port per group. For multicast packets, all but one port per group, the forwarding
port, must be excluded. Preventing the multicast packet from looping back to the source trunk.
The search engine needs to prevent a multicast packet from sending to a port that is in the same trunk group
with the source port. This is because, when we select the primary forwarding port for each group, we do not
take the source port into account. To prevent this, we simply apply one additional filter, so as to block that
forwarding port for this multicast packet.
Zarlink Semiconductor Inc.
33
MVTX2603
Data Sheet
8.4
Trunking
3 trunk groups are supported. Groups 0 and 1 can trunk up to 4 10/100 ports. Group 2 can trunk 2 Gigabit ports.
The supported combinations are shown in the following table.
Group 0
Port 0
Port 1
Port 2
Port 3
X
X
X
X
X
X
X
X
X
Select via trunk0_mode register
Group 1
Port 4
Port 5
Port 6
X
Port 7
X
X
X
X
X
Select via trunk1_mode register
Group 2
Port 25(Giga 0)
X
Port 26 (Giga 1)
X
The trunks are individually enabled/disabled by controlling pin trunk 0,1,2.
9.0
9.1
Port Mirroring
Port Mirroring Features
The received or transmitted data of any 10/100 port in the MVTX2603AG chip can be “mirrored” to any other
port. We support two such mirrored source-destination pairs. A mirror port cannot also serve as a data port.
Please refer to the Port Mirroring Application note for further details.
9.2
Setting Registers for Port Mirroring
•
MIRROR1_SRC: Sets the source port for the first port mirroring pair. Bits [4:0] select the source port to be
mirrored. An illegal port number is used to disable mirroring (which is the default setting). Bit [5] is used to
select between ingress (Rx) or egress (Tx) data.
•
•
MIRROR1_DEST: Sets the destination port for the first port mirroring pair. Bits [4:0] select the destination
port to be mirrored. The default is port 23.
MIRROR2_SRC: Sets the source port for the second port mirroring pair. Bits [4:0] select the source port to
be mirrored. An illegal port number is used to disable mirroring (which is the default setting). Bit [5] is used
to select between ingress (Rx) or egress (Tx) data.
•
MIRROR2_DEST: Sets the destination port for the second port mirroring pair. Bits [4:0] select the
destination port to be mirrored. The default is port 0.
34
Zarlink Semiconductor Inc.
Data Sheet
10.0 TBI Interface
MVTX2603
The TBI interface can be used for 1000Mbps fiber operation. In this mode, the MVTX2604 is connected to the
Serdes as shown in Figure 14. There are two TBI interfaces in the MVTX2604 devices. To enable to TBI
function, the corresponding TXEN and TXER pins need to be boot strapped. See Ball – Signal Description for
details.
M25/26_TXD[9:0]
M25/26_TXCLK
T[9:0]
REFCLK
MVTX2603
SERDES
M25/26_RXD[9:0]
M25/26_RXCLK
M25/26_COL
R[9:0]
RBC0
RBC1
Figure 14 - TBI Connection
Zarlink Semiconductor Inc.
35
MVTX2603
Data Sheet
11.0
11.1
GPSI (7WS) Interface
11.1GPSI Connection
The 10/100 RMII ethernet port can function in GPSI (7WS) mode when the corresponding TXEN pin is strapped
low with a 1K pull down resistor. In this mode, the TXD[0], TXD[1], RXD[0] and RXD[1] serve as TX data, TX
clock, RX data and RX clock respectively. The link status and collision from the PHY are multiplexed and shifted
into the switch device through external glue logic. The duplex of the port can be controlled by programming the
ECR register.
The GPSI interface can be operated in port based VLAN mode only
crs
rxd
CRS_DV
RXD[0]
RXD[1]
TXD[1]
rx_clk
tx_clk
txd
link0
col0
Port 0
Ethernet
PHY
TXD[0]
TXEN
txen
link1
link2
col1
col2
260X
link23
col23
Port 23
Ethernet
PHY
Link
Serializer
(CPLD)
Collision
Serializer
(CPLD)
Figure 15 - GPSI (7WS) mode connection diagram
36
Zarlink Semiconductor Inc.
Data Sheet
11.2 SCAN LINK and SCAN COL interface
MVTX2603
An external CPLD logic is required to take the link signals and collision signals from the GPSI PHYs and shift
them into the switch device. The switch device will drive out a signature to indicate the start of the sequence.
After that, the CPLD should shift in the link and collision status of the PHYS as shown in the figure. The extra
link status indicates the polarity of the link signal. One indicates the polarity of the link signal is active high.
scan_clk
scan_link/
scan_col
25 cycles for link/
24 cycles for col
Drived by VTX260x
Driven by MVTX260x
Drived by CPLD
Driven by CPLD
tal 32 cles period
Total 3cy2 cycles period
To
Figure 16 - SCAN LINK and SCAN COLLISON status diagram
12.0
12.1
LED Interface
LED Interface Introduction
A serial output channel provides port status information from the MVTX2603AG chips. It requires three
additional pins:
•
•
•
LED_CLK at 12.5 MHz
LED_SYN a sync pulse that defines the boundary between status frames
LED_DATA a continuous serial stream of data for all status LEDs that repeats once every frame time
A non-serial interface is also allowed, but in this case, only the Gigabit ports will have status LEDs.
A low cost external device (44 pin PAL) is used to decode the serial data and to drive an LED array for display.
This device can be customized for different needs.
12.2
Port Status
In the MVTX2603AG, each port has 8 status indicators, each represented by a single bit. The 8 LED status
indicators are
•
•
•
•
•
•
•
•
Bit 0: Flow control
Bit 1:Transmit data
Bit 2: Receive data
Bit 3: Activity (where activity includes either transmission or reception of data)
Bit 4: Link up
Bit 5: Speed (1= 100 Mb/s; 0= 10 Mb/s)
Bit 6: Full-duplex
Bit 7: Collision
Eight clocks are required to cycle through the eight status bits for each port.
Zarlink Semiconductor Inc.
37
MVTX2603
Data Sheet
When the LED_SYN pulse is asserted, the LED interface will present 256 LED clock cycles with the clock
cycles providing information for the following ports.
Port 0 (10/100): cycles #0 to cycle #7
Port 1 (10/100): cycles#8 to cycle #15
Port 2 (10/100): cycle #16 to cycle #23
...
Port 22 (10/100): cycle #176 to cycle #183
Port 23 (10/100): cycle #184 to cycle #191
Port 24 (Gigabit 0): cycle #192 to cycle #199
Port 25 (Gigabit 1): cycle #200 to cycle #207
Byte 26 (additional status): cycle #208 to cycle #215
Byte 27 (additional status): cycle #216 to cycle #223
Cycles #224 to 256 present data with a value of zero.
The first two bits of byte 26 provides the speed information for the Gigabit ports while the remainder of byte 26
and byte 27 provides bit status
•
26[0]: G0 port (1= port 24 is operating at Gigabit speed; 0= speed is either 10 or 100 Mb/s depending on
speed bit of Port 24)
•
26[1]: G1 port (1= port 25 is operating at Gigabit speed; 0= speed is either 10 or 100 Mb/s depending on
speed bit of Port 25)
•
•
•
•
•
•
•
•
26[2]: initialization done
26[3]: initialization start
26[4]: checksum ok
26[5]: link_init_complete
26[6]: bist_fail
26[7]: ram_error
27[0]: bist_in_process
27[1]: bist_done
12.3
LED Interface Timing Diagram
The signal from the MVTX2603AG to the LED decoder is shown in Figure 17.
Figure 17 - Timing Diagram of LED Interface
38
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.0
13.1
Register Definition
MVTX2603AG Register Description
2
CPU Addr
(Hex)
I C Addr
Register
Description
R/W
Default
Notes
(Hex)
0. ETHERNET Port Control Registers Substitute [N] with Port number (0..18)
ECR1P”N”
ECR2P”N”
Port Control Register 1 for Port N
Port Control Register 2 for Port N
0000 + 2 x N
001 + 2 x N
R/W 000-018
R/W 01B-033
020
000
1. VLAN Control Registers Substitute [N] with Port number (0..1A)
AVTCL
VLAN Type Code Register Low
VLAN Type Code Register High
Port “N” Configuration Register 0
Port “N” Configuration Register 1
Port “N” Configuration Register 2
Port “N” Configuration Register 3
VLAN Operating Mode
100
R/W 036
000
081
0FF
0FF
0FF
007
000
000
AVTCH
101
R/W 037
PVMAP”N”_0
PVMAP”N”_1
PVMAP”N”_2
PVMAP”N”_3
PVMODE
102 + 4N
103 + 4N
104 + 4N
105 + 4N
170
R/W 038-052
R/W 053-06D
R/W 06E-088
R/W 089-0A3
R/W 0A4
PVROUTE7-0
VLAN Router Group Enable
171-178
R/W NA
2. TRUNK Control Registers
TRUNK0_L
Trunk Group 0 Low
200
201
202
203
R/W NA
R/W NA
R/W NA
R/W 0A5
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W 0A6
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
000
000
000
003
000
001
002
003
000
000
000
003
004
005
006
007
003
TRUNK0_M
Trunk Group 0 Medium
Trunk Group 0 High
Trunk Group 0 Mode
TRUNK0_H
TRUNK0_ MODE
TRUNK0_ HASH0
TRUNK0_ HASH1
TRUNK0_ HASH2
TRUNK0_ HASH3
TRUNK1_L
Trunk Group 0 Hash 0 Destination Port 204
Trunk Group 0 Hash 1 Destination Port 205
Trunk Group 0 Hash 2 Destination Port 206
Trunk Group 0 Hash 3 Destination Port 207
Trunk Group 1 Low
Trunk Group 1 Medium
Trunk Group 1 High
Trunk Group 1 Mode
208
209
20A
20B
TRUNK1_M
TRUNK1_H
TRUNK1_ MODE
TRUNK1_ HASH0
TRUNK1_ HASH1
TRUNK1_ HASH2
TRUNK1_ HASH3
TRUNK2_ MODE
Trunk Group 1 Hash 0 Destination Port 20C
Trunk Group 1 Hash 1 Destination Port 20D
Trunk Group 1 Hash 2 Destination Port 20E
Trunk Group 1 Hash 3 Destination Port 20F
Trunk Group 2 Mode
210
Zarlink Semiconductor Inc.
39
MVTX2603
Data Sheet
2
CPU Addr
(Hex)
I C Addr
Register
Description
R/W
Default
Notes
(Hex)
TRUNK2_ HASH0
TRUNK2_ HASH1
Trunk Group 2 Hash 0 Destination Port 211
Trunk Group 2 Hash 1 Destination Port 212
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
019
01A
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
0FF
Multicast_ HASH0-0 Multicast hash result 0 mask byte 0
Multicast_ HASH0-1 Multicast hash result 0 mask byte 1
Multicast_ HASH0-2 Multicast hash result 0 mask byte 2
Multicast_ HASH0-3 Multicast hash result 0 mask byte 3
Multicast_ HASH1-0 Multicast hash result 1 mask byte 0
Multicast_ HASH1-1 Multicast hash result 1 mask byte 1
Multicast_ HASH1-2 Multicast hash result 1 mask byte 2
Multicast_ HASH1-3 Multicast hash result 1 mask byte 3
Multicast_ HASH2-0 Multicast hash result 2 mask byte 0
Multicast_ HASH2-1 Multicast hash result 2 mask byte 1
Multicast_ HASH2-2 Multicast hash result 2 mask byte 2
Multicast_ HASH2-3 Multicast hash result 2 mask byte 3
Multicast_ HASH3-0 Multicast hash result 3 mask byte 0
Multicast_ HASH3-1 Multicast hash result 3 mask byte 1
Multicast_ HASH3-2 Multicast hash result 3 mask byte 2
Multicast_ HASH3-3 Multicast hash result 3 mask byte 3
3. CPU Port Configuration
220
221
222
223
224
225
226
227
228
229
22A
22B
22C
22D
22E
22F
MAC0
CPU MAC Address byte 0
CPU MAC Address byte 1
CPU MAC Address byte 2
CPU MAC Address byte 3
CPU MAC Address byte 4
CPU MAC Address byte 5
Interrupt Mask 0
300
301
302
303
304
305
306
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
R/W NA
000
000
000
000
000
000
000
000
000
N/A
008
MAC1
MAC2
MAC3
MAC4
MAC5
INT_MASK0
INTP_MASK”N”
RQS
Interrupt Mask for MAC Port 2N, 2N+1
Receive Queue Select
310+N (310 -313) R/W NA
323
324
325
R/W NA
RO NA
RQSS
Receive Queue Status
TX_AGE
Transmission Queue Aging Time
R/W 0A7
4. Search Engine Configurations
AGETIME_LOW MAC Address Aging Time Low
400
R/W 0A8
2M:05C/
4M:02E
40
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
2
CPU Addr
(Hex)
I C Addr
Register
Description
R/W
Default
Notes
(Hex)
AGETIME_ HIGH
V_AGETIME
SE_OPMODE
SCAN
MAC Address Aging Time High
VLAN to Port Aging Time
Search Engine Operating Mode
Scan control register
401
R/W 0A9
R/W NA
R/W NA
R/W NA
000
Off
402
403
404
000
000
5. Buffer Control and QOS Control
FCBAT
QOSC
FCB Aging Timer
500
501
502
503
504
505
506
507
508
509
50A
50B
50C
R/W 0AA
R/W 0AB
R/W 0AC
R/W 0AD
R/W 0AE
R/W 0AF
R/W 0B0
R/W 0B1
R/W 0B2
R/W 0B3
R/W 0B4
R/W 0B5
R/W 0B6
0FF
000
008
000
000
000
000
000
000
000
000
000
QOS Control
FCR
Flooding Control Register
VLAN Priority Map Low
VLAN Priority Map Middle
VLAN Priority Map High
TOS Priority Map Low
TOS Priority Map Middle
TOS Priority Map High
VLAN Discard Map
AVPML
AVPMM
AVPMH
TOSPML
TOSPMM
TOSPMH
AVDM
TOSDML
BMRC
TOS Discard Map
Broadcast/Multicast Rate Control
Unicast Congestion Control
UCC
2M:008/
4M:010
MCC
Multicast Congestion Control
50D
50E
R/W 0B7
R/W 0B8
050
PR100
Port Reservation for 10/100 Ports
2M:024/
4M:036
SFCB
Share FCB Size
510
R/W 0BA
2M:014/
4M:064
C2RS
C3RS
C4RS
C5RS
C6RS
C7RS
QOSC”N”
Class 2 Reserve Size
Class 3 Reserve Size
Class 4 Reserve Size
Class 5 Reserve Size
Class 6 Reserve Size
Class 7 Reserve Size
QOS Control (N=0 - 5)
QOS Control (N=6 - 11)
QOS Control (N=12 - 23)
QOS Control (N=24 - 59)
511
R/W 0BB
R/W 0BC
R/W 0BD
R/W 0BE
R/W 0BF
R/W 0C0
R/W 0C1-0C6
R/W NA
000
000
000
000
000
000
000
000
000
000
512
513
514
515
516
517- 51C
51D- 522
523- 52E
52F- 552
R/W 0C7-0D2
R/W NA
Zarlink Semiconductor Inc.
41
MVTX2603
Data Sheet
2
CPU Addr
(Hex)
I C Addr
Register
Description
QOS Control (N=0 59)
R/W
Default
Notes
(Hex)
QOSC”N”
RDRC0
RDRC1
517 512
R/W 0C1-0D2
R/W 0FB
000
08F
088
WRED Drop Rate Control 0
WRED Drop Rate Control 1
553
554
R/W 0FC
USER_
User Define Logical Port “N” Low
(N=0-7)
580 + 2N
R/W 0D6-0DD 000
PORT”N”_LOW
USER_
User Define Logical Port “N” High
581 + 2N
590
R/W 0DE-0E5 000
PORT”N”_HIGH
USER_ PORT1:0_
PRIORITY
User Define Logic Port 1 and 0 Priority
User Define Logic Port 3 and 2 Priority
User Define Logic Port 5 and 4 Priority
User Define Logic Port 7 and 6 Priority
R/W 0E6
R/W 0E7
R/W 0E8
R/W 0E9
000
000
000
000
USER_ PORT3:2_
PRIORITY
591
USER_ PORT5:4_
PRIORITY
592
USER_
593
PORT7:6_PRI
ORITY
USER_PORT_
ENABLE
User Define Logic Port Enable
594
595
596
597
R/W 0EA
R/W 0EB
R/W 0EC
R/W 0ED
000
000
000
000
WLPP10
WLPP32
WLPP54
Well known Logic Port Priority for 1
and 0
Well known Logic Port Priority for 3
and 2
Well known Logic Port Priority for 5
and 4
WLPP76
WLPE
Well-known Logic Port Priority for 7 & 6 598
R/W 0EE
R/W 0EF
R/W 0F4
R/W 0F5
R/W 0D3
R/W 0D4
R/W 0D5
R/W NA
000
000
000
000
000
000
000
000
Well known Logic Port Enable
User Define Range Low Bit7:0
User Define Range Low Bit 15:8
User Define Range High Bit 7:0
User Define Range High Bit 15:8
User Define Range Priority
599
RLOWL
59A
RLOWH
59B
RHIGHL
59C
RHIGHH
RPRIORITY
CPUQOSC1~3
59D
59E
Byte limit for TxQ on CPU port
5A0-5A2
6. MISC Configuration Registers
MII_OP0
MII_OP1
FEN
MII Register Option 0
600
601
602
603
604
R/W 0F0
R/W 0F1
R/W 0F2
R/W N/A
R/W N/A
000
000
010
000
000
MII Register Option 1
Feature Registers
MIIC0
MII Command Register 0
MII Command Register 1
MIIC1
42
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
2
CPU Addr
(Hex)
I C Addr
Register
Description
R/W
Default
Notes
(Hex)
MIIC2
MIIC3
MIID0
MIID1
LED
MII Command Register 2
MII Command Register 3
MII Data Register 0
605
606
607
608
609
R/W N/A
R/W N/A
000
000
N/A
N/A
000
000
000
RO
RO
N/A
N/A
MII Data Register 1
LED Control Register
Device id and test
R/W 0F3
R/W N/A
R/W 0FF
DEVICE
SUM
60A
60B
EEPROM Checksum Register
7. Port Mirroring Controls
MIRROR1_SRC
MIRROR1_ DEST
MIRROR2_SRC
MIRROR2_ DEST
Port Mirror 1 Source Port
700
701
702
703
R/W N/A
R/W N/A
R/W N/A
R/W N/A
07F
017
0FF
000
Port Mirror 1 Destination Port
Port Mirror 2 Source Port
Port Mirror 2 Destination Port
F. Device Configuration Register
GCR
DCR
DCR1
DPST
DTST
DA
Global Control Register
F00
F01
F02
F03
F04
FFF
R/W N/A
000
N/A
N/A
000
N/A
DA
Device Status and Signature Register
Giga Port status
RO
RO
N/A
N/A
Device Port Status Register
Data read back register
DA Register
R/W N/A
RO
RO
N/A
N/A
13.2
Group 0 Address MAC Ports Group
13.2.1 ECR1Pn: Port N Control Register
2
•
•
I C Address h000-01A; CPU Address: 0000+2xN
2
Accessed by serial interface and I C (R/W)
7
6
5
4
3
2
1
0
Sp State
A-FC
Port Mode
Zarlink Semiconductor Inc.
43
MVTX2603
Data Sheet
Bit [0]
•
•
1 - Flow Control Off
0 - Flow Control On
• When Flow Control On:
• In half duplex mode, the MAC transmitter applies back pressure for flow control.
• In full duplex mode, the MAC transmitter sends Flow Control frames when
necessary. The MAC receiver interprets and processes incoming flow control
frames. The Flow Control Frame Received counter is incremented whenever a
flow control is received.
• When Flow Control off:
• In half duplex mode, the MAC Transmitter does not assert flow control by sending
flow control frames or jamming collision.
• In full duplex mode, the Mac transmitter does not send flow control frames. The
MAC receiver does not interpret or process the flow control frames. The Flow
Control Frame Received counter is not incremented.
Bit [1]
•
•
1 - Half Duplex - Only 10/100 mode
0 - Full Duplex
Bit [2]
•
•
1 - 10Mbps
0 - 100Mbps
Bit [4:3]
•
•
•
00 - Automatic Enable Auto Neg. This enables hardware state machine for
auto-negotiation.
01 - Limited Disable auto Neg. This disables hardware for speed auto-
negotiation. Poll MII for link status.
10 - Link Down. Disable auto Neg. state machine and force link down
(disable the port)
•
•
11 - Link Up. User ERC1 [2:0] for config.
Bit [5]
Asymmetric Flow Control Enable
• 0 - Disable asymmetric flow control
• 1 - Enable asymmetric flow control
•
•
Asymmetric Flow Control Enable. When this bit is set and flow control is on
(bit[0] = 0, don't send out a flow control frame. But MAC receiver interprets
and process flow control frames. Default is 0
Bit [7:6]
SS - Spanning tree state Default is 11
• 00 – Blocking:
• 01 - Listening:
• 10 - Learning:
Frame is dropped
Frame is dropped
Frame is dropped. Source MAC address is learned.
• 11 - Forwarding: Frame is forwarded. Source MAC address is learned.
13.2.2 ECR2Pn: Port N Control Register
2
•
•
I C Address: h01B-035; CPU Address: h0001+2xN
2
Accessed by and serial interface and I C (R/W)
7
6
5
4
2
1
0
QoS Sel
Reserve
DisL
Ftf
Futf
44
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit[0]:
Bit[1]:
Bit[2]:
Bit[3]:
•
•
•
•
Filter untagged frame (Default 0)
• 0: Disable
• 1: All untagged frames from this port are discarded
Filter Tag frame (Default 0)
• 0: Disable
• 1: All tagged frames from this port are discarded
Learning Disable (Default 0)
• 1 Learning is disabled on this port
• 0 Learning is enabled on this port
Must be set to ‘1’
Bit
•
•
•
QOS mode selection (Default 00)
[5:4:]
Determines which of the 4 sets of QoS settings is used for 10/100 ports.
Note that there are 4 sets of per-queue byte thresholds, and 4 sets of WFQ
ratios programmed. These bits select among the 4 choices for each 10/100
port. Refer to QoS Application Note.
• 00: select class byte limit set 0 and classes WFQ credit set 0
• 01: select class byte limit set 1 and classes WFQ credit set 1
• 10: select class byte limit set 2 and classes WFQ credit set 2
• 11: select class byte limit set 3 and classes WFQ credit set 3
Bit[7:6]
•
Reserved
13.2.3 GGControl – Extra GIGA Port Control
•
•
CPU Address: h036
Accessed by serial interface (R/W)
7
6
5
4
3
2
1
0
DF
DI
MiiB
RstA
DF
MiiA
RstA
Bit[0]:
Bit[1]:
•
•
Reset GIGA port A
• 0: Normal operation (default)
• 1: Reset Gigabit port A
GIGA port A use MII interface (10/100M)
• 0: Gigabit port operations at 1000 mode
• 1: Gigabit port operations at 10/100 mode
Bit[2]:
Bit[3]:
•
•
Reserved - Must be zero
GIGA port A direct flow control (MAC to MAC connection). The
MVTX2603AG supports direct flow control mechanism, the flow control frame
is therefore not sent through the Gigabit port data path.
• 0: Direct flow control disabled (default)
• 1: Direct flow control enabled
Bit[4]:
•
Reset GIGA port B
• 0: Normal operation (default)
• 1: Reset Gigabit port B
Zarlink Semiconductor Inc.
45
MVTX2603
Data Sheet
Bit[5]:
•
•
•
GIGA port B use MII interface (10/100M)
• 0: Gigabit port operates at 1000 mode
• 1: Gigabit port operates at 10/100 mode
Bit[6]:
Bit[7]:
Device information attach enable for Gigabit port B
• 0: Disable preamble stack device ID insertion (default)
• 1: Insert stack device ID into the preamble (must be enabled for ring mode).
GIGA port B direct flow control (MAC to MAC connection). The
MVTX2603AG supports direct flow control mechanism, the flow control frame
is therefore not sent through the Gigabit port data path.
• 0: Direct flow control disabled (default)
• 1: Direct flow control enabled
13.3
Group 1 Address VLAN Group
13.3.1 AVTCL – VLAN Type Code Register Low
2
•
•
I C Address h036; CPU Address: h100
2
Accessed by serial interface and I C (R/W)
Bit[7:0]:
•
VLANType_LOW: Lower 8 bits of the VLAN type code (Default 00)
13.3.2 AVTCH – VLAN Type Code Register High
2
•
•
I C Address h037; CPU Address: h101
2
Accessed by serial interface and I C (R/W)
Bit[7:0]:
•
VLANType_HIGH: Upper 8 bits of the VLAN type code (Default is 81)
13.3.3 PVMAP00_0 – Port 00 Configuration Register 0
2
•
•
I C Address h038, CPU Address: h102
2
Accessed by serial interface and I C (R/W)
Bit[7:0]:
•
VLAN Mask for ports 7 to 0 (Default FF)
This register indicates the legal egress ports. A “1” on bit 7 means that the packet can be sent to port 7. A “0” on
bit 7 means that any packet destined to port 7 will be discarded. This register works with registers 1, 2 and 3 to
form a 27 bit mask to all egress ports.
13.3.4 PVMAP00_1 – Port 00 Configuration Register 1
2
•
•
I C Address h39, CPU Address: h103
2
Accessed by serial interface and I C (R/W)
Bit[7:0]:
•
VLAN Mask for ports 15 to 8 (Default is FF)
13.3.5 PVMAP00_2 – Port 00 Configuration Register 2
2
•
•
I C Address h3A, CPU Address: h104
2
Accessed by serial interface and I C (R/W)
46
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit [7:0]:
•
VLAN Mask for ports 23 to 16 (Default FF)
13.3.6 PVMAP00_3 – Port 00 Configuration Register 3
2
•
•
I C Address h3b, CPU Address: h105
2
Accessed by serial interface and I C (R/W)
7
6
5
3
2
0
FP en
Drop
Default tx priority
VLAN Mask
Bit [2:0]:
Bit [5:3]:
VLAN Mask for ports 26 to 24 (Default 7) (Port 24 is not used)
Default Transmit priority. Used when Bit[7] = 1 (Default 0)
•
•
•
•
•
•
•
•
000 Transmit Priority Level 0 (Lowest)
001 Transmit Priority Level 1
010 Transmit Priority Level 2
011 Transmit Priority Level 3
100 Transmit Priority Level 4
101 Transmit Priority Level 5
110 Transmit Priority Level 6
111 Transmit Priority Level 7 (Highest)
Bit [6]:
Bit [7]:
Default Discard priority (Default 0)
•
•
0 - Discard Priority Level 0 (Lowest)
1 - Discard Priority Level 7(Highest)
Enable Fix Priority (Default 0)
•
0 Disable fix priority. All frames are analysed. Transmit Priority and
Discard Priority are based on VLAN Tag, TOS field or Logical Port.
•
1 Transmit Priority and Discard Priority are based on values programmed
in bit [6:3]
13.4
Port Configuration Register
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PVMAP01_0,1,2,3 I C Address h3C,3D,3E,3F; CPU Address:h106,107,108,109)
2
PVMAP02_0,1,2,3 I C Address h40,41,42,43; CPU Address:h10A, 10B, 10C, 10D)
2
PVMAP03_0,1,2,3 I C Address h44,45,46,47; CPU Address:h10E, 10F, 110, 111)
2
PVMAP04_0,1,2,3 I C Address h48,49,4A,4B; CPU Address:h112, 113, 114, 115)
2
PVMAP05_0,1,2,3 I C Address h4C,4D,4E,4F; CPU Address:h116, 117, 118, 119)
2
PVMAP06_0,1,2,3 I C Address h50,51,52,53; CPU Address:h11A, 11B, 11C, 11D)
2
PVMAP07_0,1,2,3 I C Address h54,55,56,57; CPU Address:h11E, 11F, 120, 121)
2
PVMAP08_0,1,2,3 I C Address h58,59,5A,5B; CPU Address:h122, 123, 124, 125)
2
PVMAP09_0,1,2,3 I C Address h5C,5D,5E,5F; CPU Address:h126, 127, 128, 129)
2
PVMAP10_0,1,2,3 I C Address h60,61,62,63; CPU Address:h12A, 12B, 12C, 12D)
2
PVMAP11_0,1,2,3 I C Address h64,65,66,67; CPU Address:h12E, 12F, 130, 131)
2
PVMAP12_0,1,2,3 I C Address h68,69,6A,6B; CPU Address:h132, 133, 134, 135)
2
PVMAP13_0,1,2,3 I C Address h6C,6D,6E,6F; CPU Address:h136, 137, 138, 139)
2
PVMAP14_0,1,2,3 I C Address h70,71,72,73; CPU Address:h13A, h13B, 13C, 13D)
Zarlink Semiconductor Inc.
47
MVTX2603
Data Sheet
2
•
•
•
•
•
•
•
•
•
•
•
•
PVMAP15_0,1,2,3 I C Address h74,75,76,77; CPU Address:h13E, 13F, 140, 141)
2
PVMAP16_0,1,2,3 I C Address h78,79,7A,7B; CPU Address:h142, 143, 144, 145)
2
PVMAP17_0,1,2,3 I C Address h7C,7D,7E,7F; CPU Address:h146, 147, 148, 149)
2
PVMAP18_0,1,2,3 I C Address h80,81,82,83; CPU Address:h14A, 14B, 14C, 14D)
2
PVMAP19_0,1,2,3 I C Address h84,85,86,87; CPU Address:h14E, 14F, 150, 151)
2
PVMAP20_0,1,2,3 I C Address h88,89,8A,8B; CPU Address:h152, 153, 154, 155)
2
PVMAP21_0,1,2,3 I C Address h8C,8D,8E,8F; CPU Address:h156, 157, 158, 159)
2
PVMAP22_0,1,2,3 I C Address h90,91,92,93; CPU Address:h15A, 15B, 15C, 15D)
2
PVMAP23_0,1,2,3 I C Address h94,95,96,97; CPU Address:h15E, 15F, 160, 161)
2
PVMAP24_0,1,2,3 I C Address h98,99,9A,9B; CPU Address:h162, 163, 164, 165) (Not used)
2
PVMAP25_0,1,2,3 I C Address h9C,9D,9E,9F; CPU Address:h166, 167, 168, 169) (Gigabit port 1)
2
PVMAP26_0,1,2,3 I C Address hA0,A1,A2,A3; CPU Address:h16A, 16B, 16C, 16D) (Gigabit port 2)
13.4.1 PVMODE
2
•
•
I C Address: h0A4, CPU Address: h170
2
Accessed by serial interface, and I C (R/W)
7
0
DF
SL
Bit [0]:
Bit [1]:
•
•
Reserved
Must be ‘0’
•
Slow learning
Same function as SE_OP MODE bit 7. Either bit can enable the function; both need to
be turned off to disable the feature.
Bit [2]:
•
Disable dropping frames with destination MAC addresses 0180C2000001 to
0180C200000F
• 0: Drop all frames in the range
• 1: Treats frames as multicast
• 1: Disable reset PCS
Bit [3]:
Bit [4]:
• 0: Enable reset PCS. PCS FIFO will be reset when receiving a PCS symbol error.
•
•
Support MAC address 0
• 0: MAC address 0 is not learned.
• 1: MAC address 0 is learned.
Bit [7:5]:
Reserved
13.4.2 TRUNK0_MODE– Trunk group 0 mode
2
•
•
I C Address: h0A5; CPU Address: h203
2
Accessed by serial interface and I C (R/W)
7
3
2
1
0
Hash Select
Port Select
48
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit [1:0]:
•
•
Port selection in unmanaged mode. Input pin TRUNK0 enable/disable
trunk group 0.
• 00 Reserved
• 01 Port 0 and 1 are used for trunk 0
• 10 Port 0,1 and 2 are used for trunk 0
• 11 Port 0,1,2 and 3 are used for trunk 0
Bit [3:2]
Hash Select. The Hash selected is valid for Trunk 0, 1 and 2. (Default
00)
• 00 Use Source and Destination Mac Address for hashing
• 01 Use Source Mac Address for hashing
• 10 Use Destination Mac Address for hashing
• 11 Use source destination MAC address and ingress physical port number
for hashing
Note: Trunk group 2 (two gigabit ports) is enabled/disabled using input pin TRUNK2.
13.4.3 TRUNK1_MODE – Trunk group 1 mode
2
•
•
I C Address: h0A6; CPU Address: h20B
2
Accessed by serial interface and I C (R/W)
7
3
2
1
0
Port Select
Bit [1:0]:
•
Port selection in unmanaged mode. Input pin TRUNK1
enable/disable trunk group 1.
•
•
•
•
00 Reserved
01 Port 4 and 5 are used for trunk1
10 Reserved
11 Port 4,5,6 and 7 are used for trunk1
13.4.4 TRUNK1_HASH0 – Trunk group 1 hash result 0 destination port number
•
•
•
CPU Address: h20C
Accessed by serial interface (R/W)
Bit [4:0]
Hash result 0 destination port number (Default 04)
13.4.5 TX_AGE – Tx Queue Aging timer
2
•
•
I C Address: h07;CPU Address: h325
Accessed by serial interface (RW)
7
5
0
Tx Queue Agent
•
•
•
Bit[5:0]: Unit of 100ms (Default 8)
Disable transmission queue aging if value is zero. Aging timer for all ports and queues.
For no packet loss flow control, this register must be set to 0.
13.5
Group 4 Address Search Engine Group
13.5.1 AGETIME_LOW – MAC address aging time Low
Zarlink Semiconductor Inc.
49
MVTX2603
Data Sheet
2
•
I C Address: h0A8; CPU Address: h400
2
•
•
•
Accessed by serial interface and I C (R/W)
Bit [7:0] Low byte of the MAC address aging timer.
MAC address aging is enable/disable by boot strap TSTOUT9
13.5.2 AGETIME_HIGH –MAC address aging time High
2
•
•
•
•
•
I C Address: h0A9; CPU Address: h401
2
Accessed by serial interface and I C (R/W)
Bit [7:0]: High byte of the MAC address aging timer.
The default setting provide 300 seconds aging time. Aging time is based on the following equation:
{AGETIME_TIME,AGETIME_LOW} X (# of MAC address entries in the memory x 100µsec). Number of
MAC entries = 32K when 1MB is used per bank. Number of MAC entries = 64K when 2MB is used per bank.
50
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.5.3 V_AGETIME – VLAN to Port aging time
•
•
•
CPU Address: h402
Accessed by serial interface (R/W)
Bit [7:0] (Default FF) Reserved
13.5.4 SE_OPMODE – Search Engine Operation Mode
•
•
•
CPU Address: h403
Accessed by serial interface (R/W)
{SE_OPMODE} X(# of entries 100usec)
7
6
5
4
3
2
1
0
SL
DMS
Bit [0]:
Bit [1]:
Bit [2]:
Bit [3]:
Bit [4]:
Bit [5]:
Bit [6]:
•
•
•
•
•
•
•
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Disable MCT speedup aging
• 1 – Disable speedup aging when MCT resource is low.
• 0 – Enable speedup aging when MCT resource is low.
Bit [7]:
•
Slow Learning
• 1– Enable slow learning. Learning is temporary disabled when search
demand is high
• 0 – Learning is performed independent of search demand
13.6
Group 5 Address Buffer Control/QOS Group
13.6.1 FCBAT – FCB Aging Timer
2
•
I C Address: h0AA; CPU Address: h500
7
0
FCBAT
FCB Aging time. Unit of 1ms. (Default FF)
This function is for buffer aging control. It is used to configure the aging
time, and can be enabled/ disabled through bootstrap pin. It is not
recommended to use this function for normal operation.
Bit [7:0]:
•
•
13.6.2 QOSC – QOS Control
2
•
•
I C Address: h0AB; CPU Address: h501
2
Accessed by serial interface and I C (R/W)
Zarlink Semiconductor Inc.
51
MVTX2603
Data Sheet
7
6
5
4
0
L
Tos-d
Tos-p
VF1c
Bit [0]:
Bit [4]:
•
•
QoS frame lost is OK. Priority will be available for flow control enabled
source only when this bit is set (Default 0)
Per VLAN Multicast Flow Control (Default 0)
• 0 - Disable
• 1 - Enable
Bit [5]:
Bit [6]:
•
•
Reserved
Select TOS bits for Priority (Default 0)
• 0 - Use TOS [4:2] bits to map the transmit priority
• 1 - Use TOS [7:5] bits to map the transmit priority
Bit [7]:
•
Select TOS bits for Drop Priority (Default 0)
• 0 - Use TOS[4:2] bits to map the drop priority
• 1 - Use TOS[7:5] bits to map the drop priority
13.6.3 FCR – Flooding Control Register
2
•
•
I C Address: h0AC; CPU Address: h502
2
Accessed by serial interface and I C (R/W)
7
6
4
3
0
Tos
TimeBase
U2MR
Bit [3:0]:
•
•
U2MR: Unicast to Multicast Rate. Units in terms of time base defined in
bits [6:4]. This is used to limit the amount of flooding traffic. The value
in U2MR specifies how many packets are allowed to flood within the
time specified by bit [6:4]. To disable this function, program U2MR to 0.
(Default = 8)
Bit [6:4]:
TimeBase:
000 = 100us
001 = 200us
010 = 400us
011 = 800us
100 = 1.6ms
101 = 3.2ms
110 = 6.4ms
111 = 100us (same as 000)
•
(Default = 000)
52
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit [7]:
•
Select VLAN tag or TOS (IP packets) to be preferentially picked to map
transmit priority and drop priority (Default = 0).
• 0 – Select VLAN Tag priority field over TOS
• 1 – Select TOS over VLAN tag priority field
13.6.4 AVPML – VLAN Priority Map
2
•
•
I C Address: h0AD; CPU Address: h503
2
Accessed by serial interface and I C (R/W)
7
6
5
3
2
0
Registers AVPML, AVPMM, and AVPMH allow the eight VLAN priorities to map into eight internal level transmit
priorities. Under the internal transmit priority, seven is highest priority where as zero is the lowest. This feature
allows the user the flexibility of redefining the VLAN priority field. For example, programming a value of 7 into bit
2:0 of the AVPML register would map VLAN priority 0 into internal transmit priority 7. The new priority is used
inside the 2603. When the packet goes out it carries the original priority.
Bit [2:0]:
Bit [5:3]:
Bit [7:6]:
•
•
•
Priority when the VLAN tag priority field is 0 (Default 0)
Priority when the VLAN tag priority field is 1 (Default 0)
Priority when the VLAN tag priority field is 2 (Default 0)
13.6.5 AVPMM – VLAN Priority Map
2
•
•
I C Address: h0AE, CPU Address: h504
2
Accessed by serial interface and I C (R/W)
7
6
4
3
1
0
•
Map VLAN priority into eight level transmit priorities:
Bit [0]:
•
•
•
•
Priority when the VLAN tag priority field is 2 (Default 0)
Priority when the VLAN tag priority field is 3 (Default 0)
Priority when the VLAN tag priority field is 4 (Default 0)
Priority when the VLAN tag priority field is 5 (Default 0)
Bit [3:1]:
Bit [6:4]:
Bit [7]:
13.6.6 AVPMH – VLAN Priority Map
2
•
•
I C Address: h0AF, CPU Address: h505
2
Accessed by serial interface and I C (R/W)
7
6
4
3
1
0
Map VLAN priority into eight level transmit priorities:
Bit [1:0]:
•
Priority when the VLAN tag priority field is 5 (Default 0)
Zarlink Semiconductor Inc.
53
MVTX2603
Data Sheet
Bit [4:2]:
Bit [7:5]:
•
•
Priority when the VLAN tag priority field is 6 (Default 0)
Priority when the VLAN tag priority field is 7 (Default 0)
54
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.6.7 TOSPML – TOS Priority Map
2
•
•
I C Address: h0B0, CPU Address: h506
2
Accessed by serial interface and I C (R/W)
7
0
Map TOS field in IP packet into eight level transmit priorities
Bit [2:0]:
Bit [5:3]:
Bit [7:6]:
•
•
Priority when the TOS field is 0 (Default 0)
Priority when the TOS field is 1 (Default 0)
Priority when the TOS field is 2 (Default 0)
13.6.8 TOSPMM – TOS Priority Map
2
•
•
I C Address: h0B1, CPU Address: h507
2
Accessed by serial interface and I C (R/W)
7
0
Map TOS field in IP packet into four level transmit priorities
Bit [0]:
•
•
•
•
Priority when the TOS field is 2 (Default 0)
Priority when the TOS field is 3 (Default 0)
Priority when the TOS field is 4 (Default 0)
Priority when the TOS field is 5 (Default 0)
Bit [3:1]:
Bit [6:4]:
Bit [7]:
13.6.9 TOSPMH – TOS Priority Map
2
•
•
I C Address: h0B2, CPU Address: h508
2
Accessed by serial interface and I C (R/W)
7
0
Map TOS field in IP packet into four level transmit priorities:
Bit [1:0]:
Bit [4:2]:
Bit [7:5]:
•
•
•
Priority when the TOS field is 5 (Default 0)
Priority when the TOS field is 6 (Default 0)
Priority when the TOS field is 7 (Default 0)
Zarlink Semiconductor Inc.
55
MVTX2603
Data Sheet
13.6.10 AVDM – VLAN Discard Map
2
•
•
I C Address: h0B3, CPU Address: h509
2
Accessed by serial interface and I C (R/W)
7
0
Map VLAN priority into frame discard when low priority buffer usage is above threshold
Bit [0]:
Bit [1]:
Bit [2]:
Bit [3]:
Bit [4]:
Bit [5]:
Bit [6]:
Bit [7]:
•
•
•
•
•
•
•
•
Frame drop priority when VLAN tag priority field is 0 (Default 0)
Frame drop priority when VLAN tag priority field is 1 (Default 0)
Frame drop priority when VLAN tag priority field is 2 (Default 0)
Frame drop priority when VLAN tag priority field is 3 (Default 0)
Frame drop priority when VLAN tag priority field is 4 (Default 0)
Frame drop priority when VLAN tag priority field is 5 (Default 0)
Frame drop priority when VLAN tag priority field is 6 (Default 0)
Frame drop priority when VLAN tag priority field is 7 (Default 0)
13.6.11 TOSDML – TOS Discard Map
2
•
•
I C Address: h0B4, CPU Address: h50A
2
Accessed by serial interface and I C (R/W)
7
0
Map TOS into frame discard when low priority buffer usage is above threshold
Bit [0]:
Bit [1]:
Bit [2]:
Bit [3]:
Bit [4]:
Bit [5]:
Bit [6]:
Bit [7]:
•
•
•
•
•
•
•
•
Frame drop priority when TOS field is 0 (Default 0)
Frame drop priority when TOS field is 1 (Default 0)
Frame drop priority when TOS field is 2 (Default 0)
Frame drop priority when TOS field is 3 (Default 0)
Frame drop priority when TOS field is 4 (Default 0)
Frame drop priority when TOS field is 5 (Default 0)
Frame drop priority when TOS field is 6 (Default 0)
Frame drop priority when TOS field is 7 (Default 0)
56
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.6.12 BMRC - Broadcast/Multicast Rate Control
2
•
•
I C Address: h0B5, CPU Address: h50B
2
Accessed by serial interface and I C (R/W)
7
0
Broadcast Rate
Multicast Rate
•
This broadcast and multicast rate defines for each port the number of packet allowed to be forwarded within
a specified time. Once the packet rate is reached, packets will be dropped. To turn off the rate limit,
program the field to 0. Timebase is based on register 502 [6:4].
Bit [3:0]:
•
Multicast Rate Control Number of multicast packets allowed within the
time defined in bits 6 to 4 of the Flooding Control Register (FCR).
(Default 0).
Bit [7:4]:
•
Broadcast Rate Control Number of broadcast packets allowed within
the time defined in bits 6 to 4 of the Flooding Control Register (FCR).
(Default 0)
13.6.13 UCC – Unicast Congestion Control
2
•
•
I C Address: h0B6, CPU Address: h50C
2
Accessed by serial interface and I C (R/W)
7
0
Unicast congest threshold
Bit [7:0]:
•
Number of frame count. Used for best effort dropping at B% when
destination port’s best effort queue reaches UCC threshold and shared
pool is all in use. Granularity 1 frame. (Default: h10 for 2 MB/bank or h08
for 1 MB/bank)
13.6.14 MCC – Multicast Congestion Control
2
•
•
I C Address: h0B7, CPU Address: h50D
2
Accessed by serial interface and I C (R/W)
7
5
4
0
FC reaction prd
Multicast congest threshold
Bit [4:0]:
Bit [7:5]:
•
•
In multiples of two. Used for triggering MC flow control when
destination multicast port’s best effort queue reaches MCC threshold.
(Default 0x10)
Flow control reaction period (Default 2) Granularity 4uSec.
Zarlink Semiconductor Inc.
57
MVTX2603
Data Sheet
13.6.15 PR100 – Port Reservation for 10/100 ports
2
•
•
I C Address: h0B8, CPU Address: h50E
2
Accessed by serial interface and I C (R/W)
7
4
3
0
Buffer low thd
SP Buffer reservation
Bit [3:0]:
•
•
Per port buffer reservation.
Define the space in the FDB reserved for each 10/100 port. Expressed
in multiples of 4 packets. For each packet 1536 bytes are reserved in
the memory.
Bits [7:4]:
•
•
Expressed in multiples of 4 packets. Threshold for dropping all best
effort frames when destination port best efforts queues reach UCC
threshold and shared pool all used and source port reservation is at or
below the PR100[7:4] level. Also the threshold for initiating UC flow
control.
Default:
• h36 for 24+2 configuration with memory 2MB/bank;
• h24 for 24+2 configuration with 1MB/bank;
13.6.16 PRG – Port Reservation for Giga ports
2
•
•
I C Address: h0B9, CPU Address: h50F
2
Accessed by serial interface and I C (R/W)
7
3
0
Buffer low thd
SP buffer reservation
Bit [3:0]:
•
•
Per source port buffer reservation.
Define the space in the FDB reserved for each Gigabit port. Expressed
in multiples of 16 packets. For each packet 1536 bytes are reserved in
the memory.
Bits [7:4]:
•
•
Expressed in multiples of 16 packets. Threshold for dropping all best
effort frames when destination port best effort queues reach UCC
threshold and shared pool is all used and source port reservation is at
or below the PRG[7:4] level. Also the threshold for initiating UC flow
control.
Default:
• H58 for memory 2MB/bank;
• H35 for 1MB/bank;
58
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.6.17 SFCB – Share FCB Size
2
•
•
I C Address: h0BA, CPU Address: h510
2
Accessed by serial interface and I C (R/W)
7
0
Shared buffer size
Bits [7:0]:
•
•
Expressed in multiples of 4 packets. Buffer reservation for shared pool.
Default:
• h64 for 24+2 configuration with memory of 2MB/bank;
• h14 for 24+2 configuration with memory of 1MB/bank;
13.6.18 C2RS – Class 2 Reserve Size
2
•
•
I C Address: h0BB, CPU Address: h511
2
Accessed by serial interface and I C (R/W)
7
0
0
0
0
Class 2 FCB Reservation
Buffer reservation for class 2 (third lowest priority). Granularity 1. (Default 0)
•
13.6.19 C3RS – Class 3 Reserve Size
2
•
•
I C Address: h0BC, CPU Address: h512
Accessed by serial interface and I C (R/W)
2
7
Class 3 FCB Reservation
Buffer reservation for class 3. Granularity 1. (Default 0)
•
13.6.20 C4RS – Class 4 Reserve Size
2
•
•
I C Address: h0BD, CPU Address: h513
Accessed by serial interface and I C (R/W)
2
7
Class 4 FCB Reservation
Buffer reservation for class 4. Granularity 1. (Default 0)
•
13.6.21 C5RS – Class 5 Reserve Size
2
•
•
I C Address: h0BE; CPU Address: h514
Accessed by serial interface and I C (R/W)
2
7
Class 5 FCB Reservation
Buffer reservation for class 5. Granularity 1. (Default 0)
•
Zarlink Semiconductor Inc.
59
MVTX2603
Data Sheet
13.6.22 C6RS – Class 6 Reserve Size
2
•
•
I C Address: h0BF; CPU Address h515
2
Accessed by serial interface and I C (R/W)
7
0
0
Class 6 FCB Reservation
Buffer reservation for class 6 (second highest priority). Granularity 1. (Default 0)
•
13.6.23 C7RS – Class 7 Reserve Size
2
•
•
I C Address: h0C0; CPU Address: h516
Accessed by serial interface and I C (R/W)
2
7
Class 7 FCB Reservation
Buffer reservation for class 7 (highest priority). Granularity 1. (Default 0)
•
13.6.24 Classes Byte Limit Set 0
2
•
•
•
•
Accessed by serial interface and I C (R/W)
2
C — QOSC00 – BYTE_C01 (I C Address h0C1, CPU Address 517)
2
B — QOSC01 – BYTE_C02 (I C Address h0C2, CPU Address 518)
2
A — QOSC02 – BYTE_C03 (I C Address h0C3, CPU Address 519)
QOSC00 through QOSC02 represents one set of values A-C for a 10/100 port when using the Weighted
Random Early Drop (WRED) Scheme described in Chapter 7.7. There are four such sets of values A-C
specified in Classes Byte Limit Set 0, 1, 2, and 3.
Each 10/ 100 port can choose one of the four Byte Limit Sets as specified by the QoS Select field located in bits
5 to 4 of the ECR2n register. The values A-C are per-queue byte thresholds for random early drop. QOSC02
represents A, and QOSC00 represents C.
Granularity when Delay bound is used: QOSC02: 128 bytes, QOSC01: 256 bytes. QOSC00: 512 bytes.
Granularity when WFQ is used: QOSC02: 512 bytes, QOSC01: 512 bytes, QOSC00: 512 bytes.
13.6.25 Classes Byte Limit Set 1
2
•
Accessed by serial interface and I C (R/W)
2
C - QOSC03 – BYTE_C11 (I C Address h0C4, CPU Address 51a)
2
B - QOSC04 – BYTE_C12 (I C Address h0C5, CPU Address 51b)
2
A - QOSC05 – BYTE_C13 (I C Address h0C6, CPU Address 51c)
QOSC03 through QOSC05 represents one set of values A-C for a 10/100 port when using the Weighted
Random Early Detect (WRED) Scheme.
Granularity when Delay bound is used: QOSC05: 128 bytes, QOSC04: 256 bytes. QOSC03: 512 bytes.
Granularity when WFQ is used: QOSC05: 512 bytes, QOSC04: 512 bytes, QOSC03: 512 bytes.
13.6.26 Classes Byte Limit Set 2
2
•
Accessed by serial interface and I C (R/W)
C - QOSC06 – BYTE_C21 (CPU Address 51d)
B - QOSC07 – BYTE_C22 (CPU Address 51e)
60
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
A - QOSC08 – BYTE_C23 (CPU Address 51f)
QOSC06 through QOSC08 represents one set of values A-C for a 10/100 port when using the Weighted
Random Early Detect (WRED) Scheme.
Granularity when Delay bound is used: QOSC08: 128 bytes, QOSC07: 256 bytes. QOSC06: 512 bytes.
Granularity when WFQ is used: QOSC08: 512 bytes, QOSC07: 512 bytes, QOSC06: 512 bytes.
13.6.27 Classes Byte Limit Set 3
2
•
Accessed by serial interface and I C (R/W)
C - QOSC09 – BYTE_C31 (CPU Address 520)
B - QOSC10 – BYTE_C32 (CPU Address 521)
A - QOSC11 – BYTE_C33 (CPU Address 522)
QOSC09 through QOSC011 represents one set of values A-C for a 10/100 port when using the Weighted
Random Early Detect (WRED) Scheme.
Granularity when Delay bound is used: QOSC11: 128 bytes, QOSC10: 256 bytes. QOSC09: 512 bytes.
Granularity when WFQ is used: QOSC11: 512 bytes, QOSC10: 512 bytes, QOSC09: 512 bytes.
13.6.28 Classes Byte Limit Giga Port 1
2
•
Accessed by serial interface and I C (R/W)
2
F - QOSC12 – BYTE_C2_G1 (I C Address h0C7, CPU Address 523)
2
E - QOSC13 – BYTE_C3_G1 (I C Address h0C8, CPU Address 524)
2
D - QOSC14 – BYTE_C4_G1 (I C Address h0C9, CPU Address 525)
2
C - QOSC15 – BYTE_C5_G1 (I C Address h0CA, CPU Address 526)
2
B - QOSC16 – BYTE_C6_G1 (I C Address h0CB, CPU Address 527)
2
A - QOSC17 – BYTE_C7_G1 (I C Address h0CC, CPU Address 528)
QOSC12 through QOSC17 represent the values A-F for Gigabit port 24. They are per-queue byte thresholds for
random early drop. QOSC17 represents A, and QOSC12 represents F.
Granularity when Delay bound is used: QOSC17 and QOSC16: 256 bytes, QOSC15 and QOSC14: 512 bytes,
QOSC13 and QOSC12: 1024 bytes.
Granularity when WFQ is used: QOSC17 to QOSC12: 1024 bytes
13.6.29 Classes Byte Limit Giga Port 2
2
•
Accessed by serial interface and I C (R/W)
2
F - QOSC18 – BYTE_C2_G2 (I C Address h0CD, CPU Address 529)
2
E - QOSC19 – BYTE_C3_G2 (I C Address h0CE, CPU Address 52a)
2
D - QOSC20 – BYTE_C4_G2 (I C Address h0CF, CPU Address 52b)
2
C - QOSC21 – BYTE_C5_G2 (I C Address h0D0, CPU Address 52c)
2
B - QOSC22 – BYTE_C6_G2 (I C Address h0D1, CPU Address 52d)
2
A - QOSC23 – BYTE_C7_G2 (I C Address h0D2, CPU Address 52e)
QOSC18 through QOSC23 represent the values A-F for Gigabit port 2. They are per-queue byte thresholds for
random early drop. QOSC23 represents A, and QOSC18 represents F.
Zarlink Semiconductor Inc.
61
MVTX2603
Data Sheet
Granularity when Delay Bound is used: QOSC23 and QOSC22: 256 bytes, QOSC21 and QOSC20: 512 bytes,
QOSC19 and QOSC18: 1024 bytes.
Granularity when WFQ is used: QOSC18 to QOSC23: 1024 bytes
13.6.30 Classes WFQ Credit Set 0
•
Accessed by serial interface (R/W)
W3 - QOSC24[5:0] – CREDIT_C00 (CPU Address 52f)
W2 - QOSC25[5:0] – CREDIT_C01 (CPU Address 530)
W1 - QOSC26[5:0] – CREDIT_C02 (CPU Address 531)
W0 - QOSC27[5:0] – CREDIT_C03 (CPU Address 532)
QOSC24 through QOSC27 represents one set of WFQ parameters for a 10/100 port. There are four such sets
of values. The granularity of the numbers is 1, and their sum must be 64. QOSC27 corresponds to W0, and
QOSC24 corresponds to W3.
•
•
•
QOSC24[7:6]: Priority service type for the ports select this parameter set. Option 1 to 4.
QOSC25[7]: Priority service allow flow control for the ports select this parameter set.
QOSC25[6]: Flow control pause best effort traffic only
Both flow control allow and flow control best effort only can take effect only the priority type is WFQ.
13.6.31 Classes WFQ Credit Set 1
•
Accessed by serial interface (R/W)
W3 - QOSC28[5:0] – CREDIT_C10 (CPU Address 533)
W2 - QOSC29[5:0] – CREDIT_C11 (CPU Address 534)
W1 - QOSC30[5:0] – CREDIT_C12 (CPU Address 535)
W0 - QOSC31[5:0] – CREDIT_C13 (CPU Address 536)
QOSC28 through QOSC31 represents one set of WFQ parameters for a 10/100 port. There are four such sets
of values. The granularity of the numbers is 1, and their sum must be 64. QOSC31 corresponds to W0, and
QOSC28 corresponds to W3.
QOSC28[7:6]: Priority service type for the ports select this parameter set. Option 1 to 4.
QOSC29[7]: Priority service allow flow control for the ports select this parameter set.
QOSC29[6]: Flow control pause best effort traffic only
13.6.32 Classes WFQ Credit Set 2
•
Accessed by serial interface (R/W)
W3 - QOSC32[5:0] – CREDIT_C20 (CPU Address 537)
W2 - QOSC33[5:0] – CREDIT_C21 (CPU Address 538)
W1 - QOSC34[5:0] – CREDIT_C22 (CPU Address 539)
W0 - QOSC35[5:0] – CREDIT_C23 (CPU Address 53a)
QOSC35 through QOSC32 represents one set of WFQ parameters for a 10/100 port. There are four such sets
of values. The granularity of the numbers is 1, and their sum must be 64. QOSC35 corresponds to W0, and
QOSC32 corresponds to W3.
•
•
•
QOSC32[7:6]: Priority service type for the ports select this parameter set. Option 1 to option 4.
QOSC33[7]: Priority service allow flow control for the ports select this parameter set.
QOSC33[6]: Flow Control pause best effort traffic only
62
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.6.33 Classes WFQ Credit Set 3
•
Accessed by serial interface (R/W)
W3 - QOSC36[5;0] – CREDIT_C30 (CPU Address 53b)
W2 - QOSC37[5:0] – CREDIT_C31 (CPU Address 53c)
W1 - QOSC38[5:0] – CREDIT_C32 (CPU Address 53d)
W0 - QOSC39[5:0] – CREDIT_C33 (CPU Address 53e)
QOSC39 through QOSC36 represents one set of WFQ parameters for a 10/100 port. There are four such sets
of values. The granularity of the numbers is 1, and their sum must be 64. QOSC39 corresponds to W0, and
QOSC36 corresponds to W3.
•
•
•
QOSC36[7:6]: Priority service type for the ports select this parameter set. Option 1 to option 4.
QOSC37[7]: Priority service allow flow control for the ports select this parameter set.
QOSC37[6]: Flow Control pause best effort traffic only
13.6.34 Classes WFQ Credit Port G1
•
Accessed by serial interface (R/W)
W7 - QOSC40[5:0] – CREDIT_C0_G1 (CPU Address 53F)
[7:6] - Priority service type. Option 1 to 4.
W6 - QOSC41[5:0] – CREDIT_C1_G1 (CPU Address 540)
[7]: Priority service allow flow control for the ports select this parameter set.
[6]: Flow Control pause best effort traffic only
W5 - QOSC42[5:0] – CREDIT_C2_G1 (CPU Address 541)
W4 - QOSC43[5:0] – CREDIT_C3_G1 (CPU Address 542)
W3 - QOSC44[5:0] – CREDIT_C4_G1 (CPU Address 543)
W2 - QOSC45[5:0] – CREDIT_C5_G1 (CPU Address 544)
W1 - QOSC46[5:0] – CREDIT_C6_G1 (CPU Address 545)
W0 - QOSC47[5:0] – CREDIT_C7_G1 (CPU Address 546)
QOSC40 through QOSC47 represents the set of WFQ parameters for Gigabit port 24. The granularity of the
numbers is 1, and their sum must be 64. QOSC47 corresponds to W0, and QOSC40 corresponds to W7. In the
2G trunk configuration, the sum of all values QOSC40 through QOSC47 must equal 128.
13.6.35 Classes WFQ Credit Port G2
•
Accessed by serial interface (R/W)
W7 - QOSC48[5:0] – CREDIT_C0_G2 (CPU Address 547)
[7:6] - Priority service type. Option 1 to 4.
W6 - QOSC49[5:0] – CREDIT_C1_G2 (CPU Address 548)
[7]: Priority service allow flow control for the ports select this parameter set.
[6]: Flow Control pause best effort traffic only
W5 - QOSC50[5:0] – CREDIT_C2_G2 (CPU Address 549)
W4 - QOSC51[5:0] – CREDIT_C3_G2 (CPU Address 54a)
W3 - QOSC52[5:0] – CREDIT_C4_G2 (CPU Address 54b)
Zarlink Semiconductor Inc.
63
MVTX2603
Data Sheet
W2 - QOSC53[5:0] – CREDIT_C5_G2 (CPU Address 54c)
W1 - QOSC54[5:0] – CREDIT_C6_G2 (CPU Address 54d)
W0 - QOSC55[5:0] – CREDIT_C7_G2 (CPU Address 54e)
QOSC48 through QOSC55 represents the set of WFQ parameters for Gigabit port 25. The granularity of the
numbers is 1, and their sum must be 64. QOSC55 corresponds to W0, and QOSC48 corresponds to W7. In the
2G trunk configuration, the sum of all values QOSC48 through QOSC55 must equal 128.
13.6.36 Class 6 Shaper Control Port G1
•
Accessed by serial interface (R/W)
• QOSC56[5:0] – TOKEN_RATE_G1 (Address 54f). Programs the average rate for Gigabit port 1. When equal to 0,
shaper is disable. Granularity is 1.
• QOSC57[7:0] – TOKEN_LIMIT_G1 (Address 550). Programs the maximum counter for Gigabit port1. Granularity is
16 bytes.
Shaper is implemented to control the peak and average rate for outgoing traffic with priority 6 (queue 6). Shaper
is limited to gigabit ports and queue P6 when it is in strict priority. QOSC41 programs the peak rate for Gigabit
port 1. See Programming QoS Registers application note for more information.
13.6.37 Class 6 Shaper Control Port G2
•
Accessed by serial interface (R/W)
• QOSC58[5:0] – TOKEN_RATE_G2 (CPU Address 551). Programs the average rate for Gigabit port 2. When equal to
0, shaper is disable. Granularity is 1.
• QOSC59[7:0] – TOKEN_LIMIT_G2 (CPU Address 552). Programs the maximum counter for Gigabit port2.
Granularity is 16 bytes.
Shaper is implemented to control the peak and average rate for outgoing traffic with priority 6 (queue 6). Shaper
is limited to gigabit ports and queue P6 when it is in strict priority. QOSC49 programs the peak rate for Gigabit
port 2. See Programming QoS Registers application note for more information.
13.6.38 RDRC0 – WRED Rate Control 0
2
•
•
I C Address: h0FB, CPU Address: h553
c
Accessed by serial Interface and I C (R/W)
7
0
X Rate
Y Rate
Bits [7:4]:
Bits[3:0]:
•
•
Corresponds to the frame drop percentage X% for WRED. Granularity
6.25%.
Corresponds to the frame drop percentage Y% for WRED. Granularity
6.25%.
See Programming QoS Registers application note for more information.
13.6.39 RDRC1 – WRED Rate Control 1
2
•
•
I C Address: h0FC, CPU Address: h554
2
Accessed by serial Interface and I C (R/W)
7
0
Z Rate
B Rate
64
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bits [7:4]:
Bits[3:0]:
•
•
Corresponds to the frame drop percentage Z% for WRED. Granularity
6.25%.
Corresponds to the best effort frame drop percentage B%, when
shared pool is all in use and destination port best effort queue reaches
UCC. Granularity 6.25%.
See Programming QoS Register application note for more information.
13.6.40 User Defined Logical Ports and Well Known Ports
The MVTX2600AG supports classifying packet priority through layer 4 logical port information. It can be setup
by 8 Well Known Ports, 8 User Defined Logical Ports, and 1 User Defined Range. The 8 Well Known Ports
supported are
•
•
•
•
•
•
•
•
0:23
1:512
2:6000
3:443
4:111
5:22555
6:22
7:554
Their respective priority can be programmed via Well_Known_Port [7:0] priority register. Well_Known_Port_
Enable can individually turn on/off each Well Known Port if desired.
Similarly, the User Defined Logical Port provides the user programmability to the priority, plus the flexibility to
select specific logical ports to fit the applications. The 8 User Logical Ports can be programmed via User_Port
0-7 registers. Two registers are required to be programmed for the logical port number. The respective priority
can be programmed to the User_Port [7:0] priority register. The port priority can be individually
enabled/disabled via User_Port_Enable register.
The User Defined Range provides a range of logical port numbers with the same priority level. Programming is
similar to the User Defined Logical Port. Instead of programming a fixed port number, an upper and lower limit
need to be programmed, they are: {RHIGHH, RHIGHL} and {RLOWH, RLOWL} respectively. If the value in the
upper limit is smaller or equal to the lower limit, the function is disabled. Any IP packet with a logical port that is
less than the upper limit and more than the lower limit will use the priority specified in RPRIORITY.
13.6.40.1USER_PORT0_(0~7) – User Define Logical Port (0~7)
2
•
•
•
•
•
•
•
•
•
USER_PORT_0 - I C Address h0D6 + 0DE; CPU Address 580(Low) + 581(High)
2
USER_PORT_1 - I C Address h0D7 + 0DF; CPU Address 582 + 583
2
USER_PORT_2 - I C Address h0D8 + 0E0; CPU Address 584 + 585
2
USER_PORT_3 - I C Address h0D9 + 0E1; CPU Address 586 + 587
2
USER_PORT_4 - I C Address h0DA + 0E2; CPU Address 588 + 589
2
USER_PORT_5 - I C Address h0DB + 0E3; CPU Address 58a + 58b
2
USER_PORT_6 - I C Address h0DC + 0E4; CPU Address 58c + 58d
2
USER_PORT_7 - I C Address h0DD + 0E5; CPU Address 58e + 58f
2
Accessed by serial interface and I C (R/W)
7
0
TCP/UDP Logic Port Low
Zarlink Semiconductor Inc.
65
MVTX2603
Data Sheet
7
0
TCP/UDP Logic Port High
66
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
•
(Default 00) This register is duplicated eight times from PORT 0 through PORT 7 and allows the definition of
eight separate ports.
13.6.40.2USER_PORT_[1:0]_PRIORITY - User Define Logic Port 1 and 0 Priority
2
•
•
I C Address: h0E6, CPU Address: h590
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 1
The chip allows the definition of the priority
Drop
Priority 0
Drop
•
Bits[3:0]:
Bits [7:4]:
•
•
Priority setting, transmission + dropping, for logic port 0
Priority setting, transmission + dropping, for logic port 1 (Default 00)
13.6.40.3USER_PORT_[3:2]_PRIORITY - User Define Logic Port 3 and 2 Priority
2
•
•
I C Address: h0E7, CPU Address: h591
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 3
Drop
Priority 2
Drop
13.6.40.4USER_PORT_[5:4]_PRIORITY - User Define Logic Port 5 and 4 Priority
2
•
•
I C Address: h0E8, CPU Address: h592
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 5
Drop
Priority 4
Drop
•
(Default 00)
13.6.40.5USER_PORT_[7:6]_PRIORITY - User Define Logic Port 7 and 6 Priority
2
•
•
I C Address: h0E9, CPU Address: h593
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 7
Drop
Priority 6
Drop
•
(Default 00)
13.6.40.6USER_PORT_ENABLE [7:0] – User Define Logic 7 to 0 Port Enables
2
•
•
I C Address: h0EA, CPU Address: h594
2
Accessed by serial interface and I C (R/W)
7
6
5
4
3
2
1
0
P7
P6
P5
P4
P3
P2
P1
P0
•
(Default 00)
Zarlink Semiconductor Inc.
67
MVTX2603
Data Sheet
13.6.40.7WELL_KNOWN_PORT [1:0] PRIORITY- Well Known Logic Port 1 and 0 Priority
2
•
•
I C Address: h0EB, CPU Address: h595
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 1
Drop
Priority 0
Drop
•
•
•
Priority 0 - Well known port 23 for telnet applications.
Priority 1 - Well known port 512 for TCP/UDP
(Default 00)
13.6.40.8WELL_KNOWN_PORT [3:2] PRIORITY- Well Known Logic Port 3 and 2 Priority
2
•
•
I C Address: h0EC, CPU Address: h596
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 3
Drop
Priority 2
Drop
•
•
•
Priority 2 - Well known port 6000 for XWIN.
Priority 3 - Well known port 443 for http. sec
(Default 00)
13.6.40.9WELL_KNOWN_PORT [5:4] PRIORITY- Well Known Logic Port 5 and 4 Priority
2
•
•
I C Address: h0ED, CPU Address: h597
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 5
Drop
Priority 4
Drop
•
•
•
Priority 4 - Well known port 111 for sun rpe.
Priority 5 - Well known port 22555 for IP Phone call setup.
(Default 00)
13.6.40.10WELL_KNOWN_PORT [7:6] PRIORITY- Well Known Logic Port 7 and 6 Priority
2
•
•
I C Address: h0EE, CPU Address: h598
2
Accessed by serial interface and I C (R/W)
7
5
4
3
1
0
Priority 7
Drop
Priority 6
Drop
•
•
•
Priority 6 - Well known port 22 for ssh.
Priority 7 - Well known port 554 for rtsp.
(Default 00)
68
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.6.40.11WELL KNOWN_PORT_ENABLE [7:0] – Well Known Logic 7 to 0 Port Enables
2
•
•
I C Address: h0EF, CPU Address: h599
2
Accessed by serial interface and I C (R/W)
7
6
5
4
3
2
1
0
P7
P6
P5
P4
P3
P2
P1
P0
• 1 - Enable
• 0 - Disable
(Default 00)
•
13.6.40.12RLOWL – User Define Range Low Bit 7:0
2
•
•
•
I C Address: h0F4, CPU Address: h59a
2
Accessed by serial interface and I C (R/W)
(Default 00)
13.6.40.13RLOWH – User Define Range Low Bit 15:8
2
•
•
•
I C Address: h0F5, CPU Address: h59b
2
Accessed by serial interface and I C (R/W)
(Default 00)
13.6.40.14RHIGHL – User Define Range High Bit 7:0
2
•
•
•
I C Address: h0D3, CPU Address: h59c
2
Accessed by serial interface and I C (R/W)
(Default 00)
13.6.40.15RHIGHH – User Define Range High Bit 15:8
2
•
•
•
I C Address: h0D4, CPU Address: h59d
2
Accessed by serial interface and I C (R/W)
(Default 00)
13.6.40.16RPRIORITY – User Define Range Priority
2
•
•
I C Address: h0D5, CPU Address: h59e
2
Accessed by serial interface and I C (R/W)
7
3
0
Range Transmit Priority
Drop
•
RLOW and RHIGH form a range for logical ports to be classified with priority specified in RPRIORITY.
Bit[3:1]
Bits[0]:
•
•
Transmit Priority
Drop Priority
Zarlink Semiconductor Inc.
69
MVTX2603
Data Sheet
13.7
Group 6 Address MISC Group
13.7.1 MII_OP0 – MII Register Option 0
2
•
•
I C Address: hF0, CPU Address:h600
2
Accessed by serial interface and I C (R/W)
7
6
5
4
0
hfc
1prst
Vendor Spc. Reg Addr
Bits [7]:
•
Half duplex flow control feature
• 0 = Half duplex flow control always enable
• 1 = Half duplex flow control by negotiation
Bits[6]:
Bits[5]:
•
•
Link partner reset auto-negotiate disable
Disable jabber detection. This is for HomePNA application or any serial
operation slower than 10Mbps.
• 1 = disable
• 0 = enable
Bit[4:0]:
•
Vendor specified link status register address (null value means don’t
use it) (Default 00); used when the Linkup bit position in the PHY is
non-standard.
13.7.2 MII_OP1 – MII Register Option 1
2
•
•
I C Address: hF1, CPU Address:h601
2
Accessed by serial interface and I C (R/W)
7
4
3
0
Speed bit location
Duplex bit location
Bits[3:0]:
Bits [7:4]:
•
Duplex bit location in vendor specified register
•
•
Speed bit location in vendor specified register
(Default 00)
70
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.7.3 FEN – Feature Register
2
•
•
I C Address: hF2, CPU Address: h602
2
Accessed by serial interface and I C (R/W)
7
0
DML
MII
Reserved (Default 0)
DS
Bits [0]:
•
•
Bits[1]:
Bit [2]:
Reserved (Default 0)
•
•
Support DS EF Code. (Default 0)
When 101110 is detected in DS field (TOS [7:2]), the frame priority is
set for 110 and drop is set for 0.
Bit [3]:
Bit [4]:
Bit [5]:
Bit [6]:
•
•
•
•
Reserved (Default 0)
Reserved (Default 1)
Reserved (Default 0)
Disable MII Management State Machine
• 0: Enable MII Management State Machine (Default 0)
• 1: Disable MII Management State Machine
Bit [7]:
•
Disable using MCT link list structure
• 0: Enable using MCT Link List structure (Default 0)
• 1: Disable using MCT Link List structure
13.7.4 MIIC0 – MII Command Register 0
•
•
•
CPU Address: h603
Accessed by serial interface only (R/W)
Bit [7:0] MII Data [7:0]
Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY, and no VALID; then
program MII command.
13.7.5 MIIC1 – MII Command Register 1
•
•
•
CPU Address: h604
Accessed by serial interface only (R/W)
Bit [7:0] MII Data [15:8]
Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then
program MII command.
Zarlink Semiconductor Inc.
71
MVTX2603
Data Sheet
13.7.6 MIIC2 – MII Command Register 2
•
•
CPU Address :h605
Accessed by serial interface only (R/W)
7
0
Mii OP
Register address
Bits [4:0]:
Bit [6:5]
•
•
REG_AD – Register PHY Address
OP – Operation code “10” for read command and “01” for write
command
Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then
program MII command. Writing to this register will initiate a serial management cycle to the MII management
interface. For detail information, please refer to the PHY Control Application Note.
13.7.7 MIIC3 – MII Command Register 3
•
•
CPU Address: h606
Accessed by serial interface only (R/W)
7
0
Rdy
Valid
PHY address
Bits [4:0]:
•
•
•
PHY_AD – 5 Bit PHY Address
Bit [6]
Bit [7]
VALID – Data Valid from PHY (Read Only)
RDY – Data is returned from PHY (Ready Only)
Note: Before programming MII command: set FEN[6], check MIIC3, making sure no RDY and no VALID; then
program MII command.
13.7.8 MIID0 – MII Data Register 0
•
•
•
CPU Address: h607
Accessed by serial interface only (RO)
Bit [7:0] MII Data [7:0]
13.7.9 MIID1 – MII Data Register 1
•
•
•
CPU Address: h608
Accessed by serial interface only (RO)
Bit [7:0] MII Data [15:8]
13.7.10 LED Mode – LED Control
•
•
CPU Address: h609
2
Accessed by serial interface and I C (R/W)
7
0
Clock rate
Hold Time
72
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit [0]
•
•
Reserved (Default 0)
Bit[2:1]:
Hold time for LED signal (Default= 00)
• 00=8msec 01=16msec
10=32msec 11=64msec
Bit[4:3]:
•
LED clock frequency (Default 0)
For 100MHz SCLK
00=100M/8=12.5 MHz
01=100M/16= 6.25 MHz
11=100M/64=1.5625 MHz
10=100M/32=3.125 MHz
For 125MHz SCLK
00=125M/64=1953 KHz
10=125M/512=244 KHz
01=125M/128=977KHz
11=125M/1024=122KHz
Bit[6]:
Bit[7]:
•
•
Reserved. Must be 0. (Default 0)
Reserved. Must be 0. (Default 0)
13.7.11 CHECKSUM - EEPROM Checksum
2
•
•
I C Address: FF, CPU Address: h60b
2
Accessed by serial interface and I C (R/W)
Bit [7:0]:
•
(Default 0)
Before requesting that the MVTX2603AG updates the EEPROM device, the correct checksum needs to be
calculated and written into this checksum register. When the MVTX2604AG boots from the EEPROM the
checksum is calculated and the value must be zero. If the checksum is not zeroed the MVTX2604AG does not
start and pin CHECKSUM_OK is set to zero.
The checksum formula is:
FF
2
Σ I C register = 0
I=0
13.8
Group 7 Address Port Mirroring Group
13.8.1 MIRROR1_SRC – Port Mirror source port
•
•
CPU Address: h700
Accessed by serial interface (R/W) (Default 7F)
7
0
OV
I/O
Src Port Select
Bit [4:0]:
•
Source port to be mirrored. Use illegal port number to disable mirroring
Bit [5]:
Bit [7]:
•
•
1 – select ingress data
0 – select egress data
•
Must be ‘1’
Zarlink Semiconductor Inc.
73
MVTX2603
Data Sheet
13.8.2 MIRROR1_DEST – Port Mirror destination
•
•
CPU Address: h701
Accessed by serial interface (R/W) (Default 17)
7
0
Dest Port Select
Bit [4:0]:
•
Port Mirror Destination
13.8.3 MIRROR2_SRC – Port Mirror source port
•
•
CPU Address: h702
Accessed by serial interface (R/W) (Default FF)
7
0
I/O
Src Port Select
Bit [4:0]:
Bit [5]:
•
Source port to be mirrored. Use illegal port number to disable mirroring
•
•
1 – select ingress data
0 – select egress data
Bit [7]
•
Must be 1
13.8.4 MIRROR2_DEST – Port Mirror destination
•
•
CPU Address: h703
Accessed by serial interface (R/W) (Default 00)
7
0
Dest Port Select
Bit [4:0]:
•
Port Mirror Destination
13.9
Group F Address CPU Access Group
13.9.1 GCR-Global Control Register
•
•
CPU Address: hF00
Accessed by serial interface. (R/W)
7
0
Reset
Store configuration (Default = 0)
Bist
SR
SC
Bit [0]:
Bit[1]:
•
•
Write ‘1’ followed by ‘0’ to store configuration into external EEPROM
•
•
Store configuration and reset (Default = 0)
Write ‘1’ to store configuration into external EEPROM and reset chip
74
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit[2]:
•
•
Start BIST (Default = 0)
Write ‘1’ followed by ‘0’ to start the device’s built-in self-test. The result
is found in the DCR register.
Bit[3]:
Bit[4]:
•
•
Soft Reset (Default = 0)
Write ‘1’ to reset chip
•
Reserved.
13.9.2 DCR-Device Status and Signature Register
•
•
CPU Address: hF01
Accessed by serial interface. (RO)
7
0
Revision
Signature
RE
BinP
BR
BW
2
Bit [0]:
Bit[1]:
•
•
1: Busy writing configuration to I C
2
0: Not busy writing configuration to I C
2
•
•
1: Busy reading configuration from I C
0: Not busy reading configuration from I C
2
Bit[2]:
•
•
1: BIST in progress
0: BIST not running
Bit[3]:
•
•
1: RAM Error
0: RAM OK
Bit[5:4]:
Bit [7:6]:
•
•
Device Signature
01: MVTX2603AG device
•
•
•
Revision
00: Initial Silicon
01: XA1 Silicon
13.9.3 DCR1-Giga port status
•
•
CPU Address: hF02
Accessed by serial interface (RO)
7
3
2
1
0
CIC
GIGA1
GIGA0
Bit [1:0]:
•
•
•
•
•
Giga port 0 strap option
00 – 100Mb MII mode
01 – 2G mode
10 – GMII
11 – PCS
Zarlink Semiconductor Inc.
75
MVTX2603
Data Sheet
Bit[3:2]
•
•
•
•
•
Giga port 1 strap option
00 – 100Mb MII mode
01 – 2G mode
10 – GMII
11 – PCS
Bit [7]
•
Chip initialization completed
13.9.4 DPST – Device Port Status Register
•
•
CPU Address: hF03
Accessed by serial interface (R/W)
Bit[4:0]:
•
Read back index register. This is used for selecting what to read back from
DTST. (Default 00)
5’b00000 - Port 0 Operating mode and Negotiation status
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5’b00001 - Port 1 Operating mode/Neg status
5’b00010 - Port 2 Operating mode/Neg status
5’b00011 - Port 3 Operating mode/Neg status
5’b00100 - Port 4 Operating mode/Neg status
5’b00101 - Port 5 Operating mode/Neg status
5’b00110 - Port 6 Operating mode/Neg status
5’b00111 - Port 7 Operating mode/Neg status
5’b01000 - Port 8 Operating mode/Neg status
5’b01001 - Port 9 Operating mode/Neg status
5’b01010 - Port 10 Operating mode/Neg status
5’b01011 - Port 11 Operating mode/Neg status
5’b01100 - Port 12 Operating mode/Neg status
5’b01101 - Port 13 Operating mode/Neg status
5’b01110 - Port 14 Operating mode/Neg status
5’b01111 - Port 15 Operating mode/Neg status
5’b10000 - Port 16 Operating mode/Neg status
5’b10001 - Port 17 Operating mode/Neg status
5’b10010 - Port 18 Operating mode/Neg status
5’b00011 - Port 19 Operating mode/Neg status
5’b10100 - Port 20 Operating mode/Neg status
5’b10101 - Port 21 Operating mode/Neg status
5’b10110 - Port 22 Operating mode/Neg status
5’b10111 - Port 23 Operating mode/Neg status
5’b11000 - Port 24 Operating mode/Neg status (CPU port -Not used)
5’b11001 - Port 25 Operating mode/Neg status (Gigabit port 1)
5’b11010 - Port 26 Operating mode/Neg status (Gigabit port 2)
76
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
13.9.5 DTST – Data read back register
•
•
•
CPU Address: hF04
Accessed by serial interface (RO)
This register provides various internal information as selected in DPST bit[4:0]. Refer to the PHY Control
Application Note.
MD
Info
Sig
Giga
Inkdn
FE
Fdpx
FcEn
When bit is 1
•
•
•
•
•
•
•
•
Bit[0] – Flow control enable
Bit[1] – Full duplex port
Bit[2] – Fast Ethernet port (if not gigabit port)
Bit[3] – Link is down
Bit[4] – Giga port
Bit[5] – Signal detect (when PCS interface mode)
Bit[6] – 2G signal detect (2G mode only)
Bit[7] – Module detected (for hot swap purpose)
13.9.6 DA – DA Register
•
•
•
CPU Address: hFFF
Accessed by CPU and serial interface (RO)
Always return 8’h DA. Indicate the serial port connection is good.
13.10
TBI Registers
Two sets of TBI registers are used for configure the two Gigabit ports if they are operating in TBI mode. These
TBI registers are located inside the switching chip and they are accessed through the MII command and MII
data registers.
13.10.1 Control Register
•
•
MII Address: h00
Read/Write
Bit [15]
Reset PCS logic and all TBI registers
1 = Reset.
0 = Normal operation.
Bit [14]
Bit [13]
Bit [12]
Reserved. Must be programmed with “0”.
Speed selection (See bit 6 for complete details)
•
•
•
Auto Negotiation Enable
1 = Enable auto-negotiation process.
0 = Disable auto-negotiation process (Default).
Bit [11:10]
Bit [9]
•
Reserved. Must be programmed with “0”
•
•
•
Restart Auto Negotiation.
1 = Restart auto-negotiation process.
0 = Normal operation (Default).
Bit [8:7]
•
Reserved.
Zarlink Semiconductor Inc.
77
MVTX2603
Data Sheet
Bit [6]
•
•
Speed Selection
-
-
-
-
-
Bit[6][13]
1 1 = Reserved
0 =1000Mb/s (Default)
1
0
=100Mb/s
=10Mb/s
0
Bit [5:0]
Reserved. Must be programmed with “0”.
13.10.2 Status Register
•
•
MII Address: h01
Read Only
Bit [15:9]
Bit [8]
Reserved. Always read back as “0”.
Reserved. Always read back as “1”.
Reserved. Always read back as “0”.
Bit [7:6]
Bit [5]
•
•
•
Auto-Negotiation Complete
1 = Auto-negotiation process completed.
0 = Auto-negotiation process not completed.
Bit [4]
Bit [3]
Bit [2]
•
•
Reserved. Always read back as “0”
Reserved. Always read back as “1”
•
•
•
Link Status
1 = Link is up.
0 = Link is down.
Bit [1]
Bit [0]
•
•
Reserved. Always read back as “0”.
Reserved. Always read back as “1”.
13.10.3 Advertisement Register
•
•
MII Address: h04
Read/Write
Bit [15]
Next Page
1 = Has next page capabilities.
0 = Do not has next page capabilities (Default).
Bit [14]
Reserved. Always read back as “0”. Read Only.
Remote Fault. Default is “0”.
Bit [13:12]
Bit [11:9]
Bit [8:7]
Bit [6]
•
•
Reserved. Always read back as “0”. Read Only.
Pause. Default is “00”
•
•
•
Half Duplex
1 = Support half duplex (Default).
0 = Do not support half duplex.
78
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Bit [5]
•
•
•
Full duplex
1 = Support full duplex (Default).
0 = Do not support full duplex.
Bit [4:0]
•
Reserved. Always read back as “0”. Read Only.
13.10.4 Link Partner Ability Register
•
•
MII Address: h05
Read Only
Bit [15]
Next Page
1 = Has next page capabilities.
0 = Do not has next page capabilities.
Bit [14]
Acknowledge
Remote Fault.
Bit [13:12]
Bit [11:9]
Bit [8:7]
Bit [6]
•
•
Reserved. Always read back as “0”.
Pause.
•
•
•
Half Duplex
1 = Support half duplex.
0 = Do not support half duplex.
Bit [5]
•
•
•
Full duplex
1 = Support full duplex.
0 = Do not support full duplex.
Bit [4:0]
•
Reserved. Always read back as “0”.
13.10.5 Expansion Register
•
•
MII Address: h06
Read Only
Bit [15:2]
Bit [1]
•
Reserved. Always read back as “0”.
•
•
•
Page Received.
1 = A new page has been received.
0 = A new page has not been received.
Bit [0]
•
Reserved. Always read back as “0”.
Zarlink Semiconductor Inc.
79
MVTX2603
Data Sheet
13.10.6 Extended Status Register
•
•
MII Address: h15
Read Only
Bit [15]
Bit [14]
Bit [13:0]
•
•
•
1000 Full Duplex
1 = Support 1000 full duplex operation (Default).
0 = Do not support 1000 full duplex operation.
•
•
•
1000 Half Duplex
1 = Support 1000 half duplex operation (Default).
0 = Do not support 1000 half duplex operation.
•
Reserved. Always read back as “0”.
80
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
14.0
14.1
BGA and Ball Signal Descriptions
BGA Views
14.1.1 Encapsulated View
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
L A _ D L A _ D L A _ D L A _ D L A _ D L A _ A L A _ O L A _ A L A _ A L A _ A L A _ A L A _ D L A _ D L A _ D L A _ D L A _ D R E S E R E S E T R U N R E S E R E S E
S T R O T S T O
A
B
C
S C L S D A
4
7
1 0 1 3 1 5 E 0 _ 1 3 1 6 1 9 3 3 3 6 3 9 4 2 4 5 R V E D R V E D K 1 R V E D R V E D
4
8
B E
D 0
U T 7
L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ A L A _ O L A _ A L A _ A L A _ A L A _ A L A _ D L A _ D L A _ D L A _ D L A _ D R E S E R E S E L A _ D R E S E R E S E T R U N R E S E
1 2 1 4 D S C _ E 1 _ 1 2 1 5 1 8 3 2 3 5 3 8 4 1 4 4 R V E D R V E D 6 2 R V E D R V E D K 2 R V E D
T S T O T S T O
U T 8 U T 3
1
3
6
9
7
L A _ C L A _ D L A _ D L A _ D L A _ D L A _ D L A _ A L A _ O L A _ W T _ M O L A _ A L A _ A L A _ A L A _ A L A _ D L A _ D L A _ D L A _ D R E S E R E S E R E S E T R U N R E S E R E S E A U T O T S T O T S T O T S T O T S T O
L K 1 1 E _ E _ D E 1 1 1 1 4 1 7 2 0 3 4 3 7 4 0 4 3 R V E D R V E D R V E D K 0 R V E D R V E D F D U T 1 1 U T 9 U T 4 U T 0
0
2
5
8
3
A G N L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ A L A _ A L A _ W L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D S C A N S C A N T S T O T S T O T S T O T S T O T S T O T S T O
D
E
F
D
1 7
1 9
2 1
2 3
2 5
2 7
2 9
3 1
6
1 0
E 0 _
4 9
5 1
5 3
5 5
5 7
5 9
6 1
6 3
4 7
C O L C L K U T 1 4 U T 1 3 U T 1 2 U T 1 0 U T 5 U T 1
S C A N
L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ A L A _ A L A _ W L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D L A _ D R E S E L A _ D
S C A N T S T O M 2 6 _ M 2 6 _
L I N K U T 1 5 C R S T X E R
T S T O T S T O
U T 6 U T 2
S C L K
M O D
1 6
1 8
2 0
2 2
2 4
2 6
2 8
3 0
5
9
E 1 _
4 8
5 0
5 2
5 4
5 6
5 8
6 0 R V E D 4 6
E
M 2 6 _
M 2 6 _
T X C L
T X E N
K
M 2 6 _ M 2 6 _ M 2 6 _
M T X R X D R X C L
A V C R E S I S C A N L B _ D L B _ D
V D D V D D V D D V D D V D D
C
N _
E N
6 3
6 2
3 3 3 3 3 3 3 3 3 3
C L K
V
K
R E S E
T O U T
_
M 2 6 _ M 2 6 _ M 2 6 _
L B _ C
L K
L B _ D L B _ D L B _ D
M 2 6 _ M 2 6 _
R X E R C O L
G
H
J
T X D 1 T X D 1 R X D 1
4 7 6 1 6 0
4
5
5
M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _
L B _ D L B _ D L B _ D L B _ D L B _ D
4 6 4 5 4 4 5 9 5 8
T X D 1 T X D 1 R X D 1 R X D 1 R X D 1
2
3
2
3
4
M 2 6 _ M 2 6 _
M 2 6 _ M 2 6 _
L B _ D L B _ D L B _ D L B _ D L B _ D
4 3 4 2 4 1 5 7 5 6
M 2 6 _
R X D 9
T X D 1 T X D 1
R X D 1 R X D 1
0
1
0
1
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _
T X D 9 T X D 8 R X D 6 R X D 7 R X D 8
K
L
V D D V D D
V D D V D D
4 0
3 9
3 8
5 5
5 4
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _
T X D 4 T X D 6 R X D 3 R X D 4 R X D 5
3 7 3 6 3 5 5 3 5 2
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _ M 2 6 _
T X D 7 T X D 5 R X D 0 R X D 1 R X D 2
M
N
P
V D D
V D D
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V S S V S S V S S V S S V S S V S S V S S
V D D
V D D
3 4
3 3
3 2
5 1
5 0
G R E F
L B _ A L B _ A L B _ A L B _ D L B _ D V D D
V D D M 2 6 _ M 2 6 _
_ C L K
1 8 1 9 2 0 4 9 4 8 3 3
3 3 T X D 2 T X D 3
1
G R E F
M D I O _ C L K
0
L B _ A L B _ A L B _ A L B _ W L B _ V D D
1 5 1 6 1 7 E 0 _ W E 1 _ 3 3
V D D M 2 6 _ M 2 6 _
3 3 T X D 0 T X D 1
L B _ A L B _ A L B _ A L B _ A L B _ A V D D
V D D M 2 5 _ M 2 5 _
M _ C L
R
T
M D C
K
1 0
1 1
1 2
1 3
1 4
3 3
3 3
C R S T X E R
M 2 5 _
M 2 5 _
T X C L
T X E N
K
M 2 5 _ M 2 5 _ M 2 5 _
M T X R X D R X C L
L B _ A L B _ A L B _ A L B _ A L B _ A V D D
V D D
3 3
5
6
7
8
9
3 3
C L K
V
K
M 2 5 _ M 2 5 _ M 2 5 _
L B _ O L B _ O T _ M O L B _ D L B _ D V D D
V D D
3 3
M 2 5 _ M 2 5 _
R X E R C O L
U
V
V D D
V D D
V D D
V D D
T X D 1 T X D 1 R X D 1
E 0 _
E 1 _ D E 0
3 1
3 0
3 3
4
5
5
M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _
L B _ A L B _ O L B _ W L B _ D L B _ D
T X D 1 T X D 1 R X D 1 R X D 1 R X D 1
D S C _ E _ E _ 2 9 2 8
2
3
2
3
4
M 2 5 _ M 2 5 _
M 2 5 _ M 2 5 _
L B _ D L B _ A L B _ A L B _ D L B _ D
M 2 5 _
R X D 9
W
Y
T X D 1 T X D 1
R X D 1 R X D 1
1 5
3
4
2 7
2 6
0
1
0
1
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _
R X D 6 T X D 8 T X D 9 R X D 7 R X D 8
V D D V D D
V D D V D D
1 4 1 3 1 2 2 5 2 4
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _
T X D 6 T X D 7 R X D 3 R X D 4 R X D 5
A
A
1 1
1 0
9
2 3
2 2
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _ M 2 5 _
T X D 4 T X D 5 R X D 0 R X D 1 R X D 2
A
B
8
7
6
2 1
2 0
L B _ D L B _ D L B _ D L B _ D L B _ D
M 2 5 _ M 2 5 _ M 2 3 _ M 2 3 _ M 2 3 _
T X D 2 T X D 3 C R S R X D 0 R X D 1
A
C
5
4
3
1 9
1 8
L B _ D L B _ D L B _ D L B _ D L B _ D
V D D V D D V D D V D D V D D
3 3 3 3 3 3 3 3 3 3
M 2 5 _ M 2 5 _ M 2 3 _ M 2 3 _ M 2 3 _
T X D 0 T X D 1 T X D 1 T X D 0 T X E N
A
D
2
1
0
1 7
1 6
M 0 _ T M 0 _ T M 0 _ T M 3 _ T M 3 _ T M 3 _ R M 5 _ T M 5 _ T M 5 _ R M 8 _ T M 8 _ T M 8 _ R M 1 0 _ M 1 0 _ M 1 0 _ M 1 3 _ M 1 6 _ M 1 5 _ M 1 6 _ M 1 5 _ M 1 5 _ M 1 8 _ M 1 8 _ M 1 8 _ M 2 0 _ M 2 0 _ M 2 0 _ M 2 2 _
X E N X D 0 X D 1 X D 1 X E N X D 0 X D 1 X E N X D 0 X D 1 X E N X D 0 T X D 1 T X E N R X D 0 T X D 1 T X D 0 T X D 1 R X D 1 T X E N R X D 0 T X D 1 T X E N R X D 0 T X D 1 T X E N R X D 0 R X D 1
A
E
M 0 _ R M 0 _ R M 0 _ C M 3 _ T M 3 _ C M 3 _ R M 5 _ T M 5 _ C M 5 _ R M 8 _ T M 8 _ C M 8 _ R M 1 0 _ M 1 0 _ M 1 0 _ M 1 3 _ M 1 3 _ M 1 3 _ M 1 4 _ M 1 6 R M 1 5 _ M 1 7 _ M 1 7 _ M 1 8 _ M 2 0 _ M 2 0 _ M 2 0 _ M 2 2 _ M 2 2 _
A F
X D 1 X D 0
R S
X D 0
R S
X D 1 X D 0
R S
X D 1 X D 0
R S
X D 1 T X D 0 C R S R X D 1 T X D 0 C R S R X D 1 C R S X D 0 R X D 1 R X D 0 C R S R X D 1 T X D 0 C R S R X D 1 R X D 0 C R S
M 1 _ T M 1 _ T M 1 _ T M 2 _ T M 2 _ C M 4 _ T M 4 _ C M 6 _ T M 6 _ C M 7 _ T M 7 _ C M 9 _ T M 9 _ C M 1 1 _ M 1 1 _ M 1 2 _ M 1 2 _ M 1 4 _ M 1 5 _ M 1 6 _ M 1 6 _ M 1 8 _ M 1 8 _ M 1 9 _ M 1 9 _ M 2 1 _ M 2 1 _ M 2 2 _ M 2 2 _
A
G
X E N X D 0 X D 1 X D 1
R S
X D 1
R S
X D 1
R S
X D 1
R S
X D 1
R S T X D 1 C R S T X D 1 C R S T X D 1 T X D 0 T X D 1 C R S T X D 0 C R S T X D 1 C R S T X D 1 C R S T X E N T X D 0
M 1 _ R M 1 _ C M 2 _ T M 2 _ R M 4 _ T M 4 _ R M 6 _ T M 6 _ R M 7 _ T M 7 _ R M 9 _ T M 9 _ R M 1 1 _ M 1 1 _ M 1 2 _ M 1 2 _ M 1 4 _ M 1 4 _ M 1 3 _ M 1 5 _ M 1 7 _ M 1 7 _ M 1 9 _ M 1 9 _ M 2 1 _ M 2 1 _ M 2 2 _
A
H
X D 0
R S
X D 0 X D 0 X D 0 X D 0 X D 0 X D 0 X D 0 X D 0 X D 0 X D 0 T X D 0 R X D 0 T X D 0 R X D 0 T X D 0 R X D 0 R X D 0 C R S T X D 0 R X D 1 T X D 0 R X D 0 T X D 0 R X D 0 T X D 1
M 1 _ R M 2 _ T M 2 _ R M 4 _ T M 4 _ R M 6 _ T M 6 _ R M 7 _ T M 7 _ R M 9 _ T M 9 _ R M 1 1 _ M 1 1 _ M 1 2 _ M 1 2 _ M 1 4 _ M 1 4 _ M 1 6 _ M 1 3 _ M 1 7 _ M 1 7 _ M 1 9 _ M 1 9 _ M 2 1 _ M 2 1 _
X D 1 X E N X D 1 X E N X D 1 X E N X D 1 X E N X D 1 X E N X D 1 T X E N R X D 1 T X E N R X D 1 T X E N R X D 1 T X E N T X E N T X E N T X D 1 T X E N R X D 1 T X E N R X D 1
A J
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
Figure 18 - BGA View
Zarlink Semiconductor Inc.
81
MVTX2603
Data Sheet
14.1.2 Power and Ground Distribution
The following figure provides an encapsulated view of the power and ground distribution
1
2
3
4
5
6
7
8
9
1 0
1 1
13
1 2
16
1 3
1 9
1 4
33
1 5
3 6
1 6
3 9
1 7
42
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
LA_ D LA_D LA_D LA_ D LA_D LA_ A LA_ O LA_A LA_ A LA_ A LA_A LA_ D LA_ D LA_D LA_ D LA_D RESE RESE TRUN MIRR MIRR
STRO TSTO
BE UT7
SCL SDA
A
B
C
4
7
1 0
13
1 5
4
E0
8
4 5 RVED RVED K1
OR4 OR1
LA_D LA_ D LA_D LA_D LA_ D LA_D LA_ A LA_ O LA_A LA_ A LA_ A LA_A LA_ D LA_ D LA_D LA_ D LA_D RESE RESE LA_D MIRR MIRR TRUN RESE
TSTO TSTO
UT8 UT3
D0
1
3
6
9
12 1 4 DSC E1 12 15 1 8 32 3 5 3 8 41 4 4 RVED RVED 6 2 OR5 OR2 K2 RVED
7
LA_ C LA_D LA_ D LA_D LA_D LA_ D LA_A LA_ O LA WT_ MO LA_ A LA_ A LA_A LA_ A LA_ D LA_D LA_ D LA_D RESE RESE RESE TRUN MIRR MIRR AUTO TSTO TSTO TSTO TSTO
LK 11 E_ E_ DE1 11 14 1 7 20 3 4 3 7 40 4 3 RVED RVED RVED K0 OR3 OR0 FD UT1 1 UT9 UT4 UT0
0
2
5
8
3
AGN LA_D LA_ D LA_D LA_D LA_ D LA_D LA_ D LA_ D LA_A LA_ A LA WLA_D LA_ D LA_ D LA_D LA_ D LA_D LA_D LA_ D LA_D SCAN SCAN TSTO TSTO TSTO TSTO TSTO TSTO
D
D
1 7
19
2 1
2 3
25
2 7
2 9
31
6
10
E0
4 9
51
5 3
5 5
57
5 9
6 1
63
4 7
COL CLK UT14 UT13 UT1 2 UT10 UT5 UT1
SCAN
LA_D LA_ D LA_D LA_D LA_ D LA_D LA_ D LA_ D LA_A LA_ A LA WLA_D LA_ D LA_ D LA_D LA_ D LA_D LA_D RESE LA_D
SCAN TSTO M2 6_ M26 _
LINK UT15 CRS TXER
TSTO TSTO
UT6 UT2
SCLK
E
F
MOD
1 6
18
2 0
2 2
24
2 6
2 8
30
5
9
E1
4 8
50
5 2
5 4
56
5 8
6 0 RVED 4 6
E
M2 6_
M26 _
M2 6_ M2 6_ M26 _
MTX RXD RXCL
AVC RESI SCAN LB_D LB_D
VDD VDD VDD VDD VDD
TXCL
TXEN
K
C
N_
EN
6 3
6 2
3 3 33 3 3 3 3 33
CLK
V
K
RESE
TOUT
_
M2 6_ M26 _ M2 6_
LB_ C
LK
LB_ D LB_D LB_D
M2 6_ M26 _
RXER COL
G
H
TXD1 TXD1 RXD1
47 6 1 6 0
4
5
5
M2 6_ M26 _ M2 6_ M2 6_ M26 _
TXD1 TXD1 RXD1 RXD1 RXD1
LB_ D LB_D LB_ D LB_D LB_D
4 6 4 5 44 5 9 5 8
2
3
2
3
4
M2 6_ M26 _
M2 6_ M26 _
LB_ D LB_D LB_ D LB_D LB_D
M2 6_
RXD9
J
TXD1 TXD1
RXD1 RXD1
4 3
4 2
41
5 7
5 6
0
1
0
1
LB_ D LB_D LB_ D LB_D LB_D
M2 6_ M26 _ M2 6_ M2 6_ M26 _
TXD9 TXD8 RXD6 RXD7 RXD8
VDD VDD
VDD VDD
K
L
4 0
3 9
38
5 5
5 4
LB_ D LB_D LB_ D LB_D LB_D
M2 6_ M26 _ M2 6_ M2 6_ M26 _
TXD4 TXD6 RXD3 RXD4 RXD5
3 7 3 6 35 5 3 5 2
LB_ D LB_D LB_ D LB_D LB_D
M2 6_ M26 _ M2 6_ M2 6_ M26 _
TXD7 TXD5 RXD0 RXD1 RXD2
VDD
VDD
VSS VSS VSS VSS VSS VSS VSS
VSS VSS VSS VSS VSS VSS VSS
VDD
VDD
M
N
P
3 4
3 3
32
5 1
5 0
D_ CO D_CO GREF
LB_ A LB_A LB_ A LB_D LB_D VDD
VDD M2 6_ M26 _
NFIG NFIG _CLK
1 8
1 9
20
4 9
4 8
33
3 3 TXD2 TXD3
1
0
1
GREF
_CLK
0
LB_ A LB_A LB_ A LB WLB_
VDD
33
VDD M2 6_ M26 _
3 3 TXD0 TXD1
VSS VSS VSS VSS VSS VSS VSS
VSS VSS VSS VSS VSS VSS VSS
VSS VSS VSS VSS VSS VSS VSS
MDIO
1 5 1 6 17 E0 WE1
LB_ A LB_A LB_ A LB_A LB_A VDD
VDD M2 5_ M25 _
M_CL
MDC
R
1 0
1 1
12
1 3
1 4
33
3 3
CRS TXER
K
M2 5_
M2 5_ M2 5_ M25 _
MTX RXD RXCL
LB_ A LB_A LB_ A LB_A LB_A VDD
VDD
3 3
M25 _
T
TXCL
TXEN
5
6
7
8
9
33
K
CLK
V
K
M2 5_ M25 _ M2 5_
LB_ O LB_O T_MO LB_D LB_D VDD
VDD
3 3
M2 5_ M25 _
RXER COL
VDD
VDD
VSS VSS VSS VSS VSS VSS VSS
VSS VSS VSS VSS VSS VSS VSS
VDD
VDD
U
V
TXD1 TXD1 RXD1
E0
E1
DE0
3 1
3 0
33
4
5
5
M2 5_ M25 _ M2 5_ M2 5_ M25 _
LB_ A LB_O LB WLB_D LB_D
TXD1 TXD1 RXD1 RXD1 RXD1
DSC E_ E_ 2 9 2 8
2
3
2
3
4
M2 5_ M25 _
M2 5_ M25 _
LB_ D LB_A LB_ A LB_D LB_D
M2 5_
RXD9
W
Y
TXD1 TXD1
RXD1 RXD1
1 5
3
4
2 7
2 6
0
1
0
1
LB_ D LB_D LB_ D LB_D LB_D
M2 5_ M25 _ M2 5_ M2 5_ M25 _
RXD6 TXD8 TXD9 RXD7 RXD8
VDD VDD
VDD VDD
1 4 1 3 12 2 5 2 4
LB_ D LB_D LB_ D LB_D LB_D
M2 5_ M25 _ M2 5_ M2 5_ M25 _
TXD6 TXD7 RXD3 RXD4 RXD5
A
A
1 1
1 0
9
2 3
2 2
LB_ D LB_D LB_ D LB_D LB_D
M2 5_ M25 _ M2 5_ M2 5_ M25 _
TXD4 TXD5 RXD0 RXD1 RXD2
A
B
8
7
6
2 1
2 0
LB_ D LB_D LB_ D LB_D LB_D
M2 5_ M25 _ M2 3_ M2 3_ M23 _
TXD2 TXD3 CRS RXD0 RXD1
A
C
5
4
3
1 9
1 8
LB_ D LB_D LB_ D LB_D LB_D
VDD VDD VDD VDD VDD
3 3 33 3 3 3 3 33
M2 5_ M25 _ M2 3_ M2 3_ M23 _
TXD0 TXD1 TXD1 TXD0 TXEN
A
D
2
1
0
1 7
1 6
M0_ T M0 _T M0_ T M3 _ T M3 _T M3_ R M5 _ T M5 _T M5_ R M8 _T M8 _T M8_ R M1 0_ M10 _ M10 _ M1 3_ M16 _ M1 5 _ M1 6_ M15 _ M1 5 _ M1 8_ M18 _ M1 8_ M2 0_ M20 _ M2 0_ M2 2_
XEN XD0 XD1 XD1 XEN XD0 XD1 XEN XD0 XD1 XEN XD0 TXD1 TXEN RXD0 TXD1 TXD0 TXD1 RXD1 TXEN RXD0 TXD1 TXEN RXD0 TXD1 TXEN RXD0 RXD1
A
E
M0_ R M0 _R M0_ C M3 _ T M3 _C M3_ R M5 _ T M5 _C M5_ R M8 _T M8 _C M8_ R M1 0_ M10 _ M10 _ M1 3_ M13 _ M1 3 _ M1 4_ M16 R M1 5 _ M1 7_ M17 _ M1 8_ M2 0_ M20 _ M2 0_ M2 2_ M22 _
AF
XD1 XD0
RS XD0
RS XD1 XD0
RS XD1 XD0
RS XD1 TXD0 CRS RXD1 TXD0 CRS RXD1 CRS XD0 RXD1 RXD0 CRS RXD1 TXD0 CRS RXD1 RXD0 CRS
M1_ T M1 _T M1_ T M2 _ T M2 _C M4_ T M4 _ C M6 _T M6_ C M7 _T M7 _C M9_ T M9 _C M11 _ M11 _ M1 2_ M12 _ M1 4 _ M1 5_ M16 _ M1 6 _ M1 8_ M18 _ M1 9_ M1 9_ M21 _ M2 1_ M2 2_ M22 _
A
G
XEN XD0 XD1 XD1
RS XD1 RS XD1
RS XD1
RS XD1 RS TXD1 CRS TXD1 CRS TXD1 TXD0 TXD1 CRS TXD0 CRS TXD1 CRS TXD1 CRS TXEN TXD0
M1 _R M1_ C M2 _ T M2 _R M4_ T M4 _ R M6 _T M6_ R M7 _T M7 _R M9_ T M9 _R M11 _ M11 _ M1 2_ M12 _ M1 4 _ M1 4_ M13 _ M1 5 _ M1 7_ M17 _ M1 9_ M1 9_ M21 _ M2 1_ M2 2_
A
H
XD0
RS XD0 XD0 XD0 XD0 XD0 XD0 XD0 XD0 XD0 XD0 TXD0 RXD0 TXD0 RXD0 TXD0 RXD0 RXD0 CRS TXD0 RXD1 TXD0 RXD0 TXD0 RXD0 TXD1
M1_ R M2 _ T M2 _R M4_ T M4 _ R M6 _T M6_ R M7 _T M7 _R M9_ T M9 _R M11 _ M11 _ M1 2_ M12 _ M1 4 _ M1 4_ M16 _ M1 3 _ M1 7_ M17 _ M1 9_ M1 9_ M21 _ M2 1_
XD1 XEN XD1 XEN XD1 XEN XD1 XEN XD1 XEN XD1 TXEN RXD1 TXEN RXD1 TXEN RXD1 TXEN TXEN TXEN TXD1 TXEN RXD1 TXEN RXD1
AJ
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
Figure 19 - Power and Ground Distribution View
82
Zarlink Semiconductor Inc.
Data Sheet
14.2 Ball – Signal Descriptions
MVTX2603
All pins are CMOS type; all Input Pins are 5 Volt tolerance; and all Output Pins are 3.3 CMOS drive.
14.2.1 Ball Signal Descriptions
Ball Signal Descriptions Table
Ball No(s)
Symbol
I/O
Description
P_DATA[15:8][5:0
]
I/O with pull up
Not used. Leave unconnected
C19, B19, A19, C20, B20, A20,
C21, E20, B22, A22, C23, B23,
A23, C24
B25
P_INT#
Output
Not used
2
2
I C Interface (0) Note: In unmanaged mode, Use I C and Serial control interface to configure the system
2
SCL
SDA
Output
I C Data Clock
A24
2
I/O-TS with pull up
I C Data I/O
A25
Serial Control Interface
STROBE
Input with weak internal Serial Strobe Pin
pull up
A26
D0
Input
Serial Data Input
B26
AUTOFD
Output with pull up
Serial Data Output (AutoFD)
C25
Frame Buffer Interface
LA_D[63:0]
I/O-TS with pull up
Frame Bank A– Data Bit [63:0]
D20, B21, D19, E19,D18, E18,
D17, E17, D16, E16, D15, E15,
D14, E14, D13, E13, D21, E21,
A18, B18, C18, A17, B17, C17,
A16, B16, C16, A15, B15, C15,
A14, B14, D9, E9, D8, E8, D7,
E7, D6, E6, D5, E5, D4, E4, D3,
E3, D2, E2, A7, B7, A6, B6, C6,
A5, B5, C5, A4, B4, C4, A3, B3,
C3, B2, C2
LA_A[20:3]
LA_ADSC#
Output
Frame Bank A – Address Bit [20:3]
C14, A13, B13, C13, A12, B12,
C12, A11, B11, C11, D11, E11,
A10, B10, D10, E10, A8, C7
Output with pull up
Frame Bank
Control
A
Address Status
B8
LA_CLK
LA_WE#
Output
Frame Bank A Clock Input
C1
C9
Output with pull up
Frame Bank A Write Chip Select for
one layer SRAM application
LA_WE0#
Output with pull up
Frame Bank A Write Chip Select for
lower layer of two layers SRAM
application
D12
Zarlink Semiconductor Inc.
83
MVTX2603
Data Sheet
Ball Signal Descriptions Table (continued)
LA_WE1#
Output with pull up
Frame Bank A Write Chip Select for
upper layer of two layers SRAM
application
E12
LA_OE#
Output with pull up
Output with pull up
Frame Bank A Read Chip Select for
one layer SRAM application
C8
A9
LA_OE0#
Frame Bank A Read Chip Select for
lower layer of two layers SRAM
application
LA_OE1#
Output with pull up
I/O-TS with pull up.
Frame Bank A Read Chip Select for
upper layer of two layers SRAM
application
B9
LB_D[63:0]
Frame Bank B– Data Bit [63:0]
F4, F5, G4, G5, H4, H5, J4, J5,
K4, K5, L4, L5, M4, M5, N4, N5,
G3, H1, H2, H3, J1, J2, J3, K1,
K2, K3, L1, L2, L3, M1, M2, M3,
U4, U5, V4, V5, W4, W5, Y4,
Y5, AA4, AA5, AB4, AB5, AC4,
AC5, AD4, AD5, W1, Y1, Y2,
Y3, AA1, AA2, AA3, AB1, AB2,
AB3, AC1, AC2, AC3, AD1,
AD2, AD3
LB_A[20:3]
LB_ADSC#
Output
Frame Bank B – Address Bit [20:3]
N3, N2, N1, P3, P2, P1, R5, R4,
R3, R2, R1, T5, T4, T3, T2, T1,
W3, W2
Output with pull up
Frame Bank
Control
B
Address Status
V1
LB_CLK
LB_WE#
Output
Frame Bank B Clock Input
G1
V3
Output with pull up
Frame Bank B Write Chip Select for
one layer SRAM application
LB_WE0#
LB_WE1#
Output with pull up
Output with pull up
Frame Bank B Write Chip Select for
lower layer of two layers SRAM
application
P4
P5
Frame Bank B Write Chip Select for
upper layer of two layers SRAM
application
LB_OE#
Output with pull up
Output with pull up
Frame Bank B Read Chip Select for
one layer SRAM application
V2
U1
LB_OE0#
Frame Bank B Write Chip Select for
lower layer of two layers SRAM
application
LB_OE1#
Output with pull up
Frame Bank B Write Chip Select for
upper layer of two layers SRAM
application
U2
Fast Ethernet Access Ports [23:0] RMII
M_MDC
Output
MII Management Data Clock
(Common for all MII Ports [23:0])
–
R28
84
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball Signal Descriptions Table (continued)
M_MDIO
I/O-TS with pull up
MII Management Data I/O
–
P28
(Common for all MII Ports –[23:0]))
Reference Input Clock
M_CLKI
Input
R29
M[23:0]_RXD[1]
Input with weak internal Ports [23:0] – Receive Data Bit [1]
pull up resistors.
AC29, AE28, AJ27, AF27,
AJ25, AF24, AH23, AE19,
AF21, AJ19, AF18, AJ17, AJ15,
AF15, AJ13, AF12, AJ11, AJ9,
AF9, AJ7, AF6, AJ5, AJ3, AF1
M[23:0]_RXD[0]
Input with weak internal Ports [23:0] – Receive Data Bit [0]
pull up resistors
AC28, AF28, AH27, AE27,
AH25, AE24, AF22, AF20,
AE21, AH19, AH20, AH17,
AH15, AE15, AH13, AE12,
AH11, AH9, AE9, AH7, AE6,
AH5, AH2, AF2
M[23:0]_CRS_DV
Input with weak internal Ports [23:0] – Carrier Sense and
pull down resistors. Receive Data Valid
AC27, AF29, AG27, AF26,
AG25, AG23, AF23, AG21,
AH21, AF19, AF17, AG17,
AG15, AF14, AG13, AF11,
AG11, AG9, AF8, AG7, AF5,
AG5, AH3, AF3
M[23:0]_TXEN
M[23:0]_TXD[1]
I/O- TS with pull up, slew Ports [23:0] – Transmit Enable
Strap option for RMII/GPSI
AD29, AG28, AJ26, AE26,
AJ24, AE23, AJ22, AJ20, AE20,
AJ18, AJ21, AJ16, AJ14, AE14,
AJ12, AE11, AJ10, AJ8, AE8,
AJ6, AE5, AJ4, AG1, AE1
Output, slew
Ports [23:0] – Transmit Data Bit [1]
AD27, AH28, AG26, AE25,
AG24, AE22, AJ23, AG20,
AE18, AG18, AE16, AG16,
AG14, AE13, AG12, AE10,
AG10, AG8, AE7, AG6, AE4,
AG4, AG3, AE3
M[23:0]_TXD[0]
Output, slew
Ports [23:0] – Transmit Data Bit [0]
AD28, AG29, AH26, AF25,
AH24, AG22, AH22, AE17,
AG19, AH18, AF16, AH16,
AH14, AF13, AH12, AF10,
AH10, AH8, AF7, AH6, AF4,
AH4, AG2, AE2
GMII Gigabit Ethernet Access Ports 0 & 1
M25_TXD[15:0]
Transmit Data Bit [15:0]
U26, U25, V26, V25, W26,
W25, Y27, Y26, AA26, AA25,
AB26, AB25, AC26, AC25,
AD26, AD25
Output
M25_RX_DV
M25_RX_ER
Input w/ pull down
Input w/ pull up
Receive Data Valid
Receive Error
T28
U28
Zarlink Semiconductor Inc.
85
MVTX2603
Data Sheet
Ball Signal Descriptions Table (continued)
M25_CRS
Input w/ pull down
Input w/ pull up
Input w/ pull up
Input w/ pull up
Carrier Sense
R25
U29
T29
M25_COL
Collision Detected
Receive Clock
M25_RXCLK
M25_RXD[15:0]
Receive Data Bit [15:0]
U27, V29, V28, V27, W29,
W28, W27, Y29, Y28, Y25,
AA29, AA28, AA27, AB29,
AB28, AB27
M25_TX_EN
M25_TX_ER
M25_ TXCLK
GREF_CLK0
M26_TXD[15:0]
Output w/ pull up
Output w/ pull up
Output
Transmit Data Enable
Transmit Error
T26
R26
T25
P29
Gigabit Transmit Clock
Input w/ pull up
Gigabit Reference Clock
Transmit Data Bit [15:0]
G26, G25, H26, H25, J26, J25,
K25, K26, M25, L26, M26, L25,
N26, N25, P26, P25
Output
M26_RX_DV
M26_RX_ER
M26_CRS
Input w/ pull down
Input w/ pull up
Input w/ pull down
Input w/ pull up
Input w/ pull up
Input w/ pull up
Receive Data Valid
Receive Error
F28
G28
E25
G29
F29
Carrier Sense
M26_COL
Collision Detected
Receive Clock
M26_RXCLK
M26_RXD[15:0]
Receive Data Bit [15:0]
G27,H29, H28, H27, J29, J28,
J27, K29, K28, K27, L29, L28,
L27, M29, M28, M27
M26_TX_EN
M26_TX_ER
M26_ TXCLK
GREF_CLK1
Output w/ pull up
Output w/ pull up
Output
Transmit Data Enable
Transmit Error
F26
E26
Gigabit Transmit Clock
Gigabit Reference Clock
F25
Input w/ pull up
N29
LED Interface
C29
LED_CLK/TSTOU I/O- TS with pull up
T0
LED Serial Interface Output Clock
LED_SYN/TSTO
UT1
I/O- TS with pull up
D29
E29
B28
LED Output Data Stream Envelope
LED Serial Data Output Stream
LED_BIT/TSTOU
T2
I/O- TS with pull up
G1_RXTX#/TSTO I/O- TS with pull up
UT3
LED for Gigabit port 1 (receive +
transmit)
G1_DPCOL#/TST I/O- TS with pull up
OUT4
C28
LED for Gigabit port 1 (full duplex +
collision)
86
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball Signal Descriptions Table (continued)
G1_LINK#/TSTO
UT5
I/O- TS with pull up
D28
LED for Gigabit port 1
G2_RXTX#/TSTO I/O- TS with pull up
UT6
E28
LED for Gigabit port 2 (receive +
transmit)
G2_DPCOL#/TST I/O- TS with pull up
OUT7
A27
LED for Gigabit port 2 (full duplex +
collision)
G2_LINK#/TSTO
UT8
I/O- TS with pull up
I/O- TS with pull up
I/O- TS with pull up
I/O- TS with pull up
I/O- TS with pull up
I/O- TS with pull up
B27
C27
D27
C26
D26
D25
D24
E24
LED for Gigabit port 2
INIT_DONE/TST
OUT9
System start operation
Start initialization
INIT_START/TST
OUT10
CHECKSUM_OK/
TSTOUT11
EEPROM read OK
FCB_ERR/TSTO
UT12
FCB memory self test fail
MCT memory self test fail
Processing memory self test
Memory self test done
MCT_ERR/TSTO
UT13
BIST_IN_PRC/TS I/O- TS with pull up
TOUT14
BIST_DONE/TST
OUT15
I/O- TS with pull up
Trunk Enable
TRUNK0
TRUNK1
TRUNK2
Input w/ weak internal Trunk Port Enable
pull down resistors
C22
Input w/ weak internal Trunk Port Enable
pull down resistors
A21
B24
Input w/ weak internal Trunk Port Enable
pull down resistors
Test Facility
T_MODE0
I/O-TS
Test Pin – Set Mode upon Reset,
U3
and provides NAND Tree test output
during test mode (Pull Up)
Zarlink Semiconductor Inc.
87
MVTX2603
Data Sheet
Ball Signal Descriptions Table (continued)
T_MODE1
I/O-TS
Test Pin – Set Mode upon Reset,
and provides NAND Tree test output
during test mode (Pull Up)
C10
T_MODE1 T_MODE0
0
0
1
1
0
1
0
1
NandTree
Reserved
Reserved
Regular
operation
T_MODE0 and T_MODE1 are used
for manufacturing tests. The signals
should both be set to 1 for regular
operation.
SCAN_EN
Input with pull down
Input with pull down
Scan Enable
F3
0 - Normal mode (unconnected)
1 - Enables Test mode.
SCANMODE
E27
0 - Normal mode (unconnected)
System Clock, Power, and Ground Pins
SCLK
VDD
Input
System Clock at 100 MHz
+2.5 Volt DC Supply
E1
Power
K12, K13, K17,K18 M10, N10,
M20, N20, U10, V10, U20, V20,
Y12, Y13, Y17, Y18
VDD33
VSS
Power
+3.3 Volt DC Supply
Ground
F13, F14, F15, F16, F17, N6,
P6, R6, T6, U6, N24, P24, R24,
T24, U24, AD13, AD14, AD15,
AD16, AD17
Power Ground
M12, M13, M14, M15, M16,
M17, M18, N12, N13, N14, N15,
N16, N17, N18, P12, P13, P14,
P15, P16, P17, P18, R12, R13,
R14, R15, R16, R17, R18, T12,
T13, T14, T15, T16, T17, T18,
U12, U13, U14, U15, U16, U17,
U18, V12, V13, V14, V15, V16,
V17, V18,
AVCC
AGND
Analog Power
Analog Ground
Used for the PLL
Used for the PLL
F1
D1
MISC
D22
SCANCOL
SCANCLK
Input
Scans the Collision signal of Home
PHY
Input/ output
Clock for scanning Home PHY
collision and link
D23
88
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball Signal Descriptions Table (continued)
SCANLINK
Input
Link up signal from Home PHY
E23
F2
RESIN#
Input
Reset Input
Reset PHY
Reserved
RESETOUT_
Reserved
Output
I/O-TS
G2
B22
Bootstrap Pins (Default= pull up, 1= pull up 0= pull down)
After reset TSTOUT0 to TSTOUT15 are used by the LED interface.
TSTOUT0
Default: Active High (1)
Default: Enable (1)
Default: (1)
GIGA Link polarity
C29
0 - Active low
1 - Active high
TSTOUT1
RMII MAC Power Saving Enable
D29
0 - No power saving
1 - Power saving
TSTOUT2
TSTOUT3
Must be 0. Use external pull down
E29
B28
Default: Disable Hot Module detect enable
Swap (1)
0 - Hot swap enable
1 - Hot swap disable
TSTOUT4
TSTOUT5
Default: SBRAM (1)
Default: SCLK (1)
Default: (1)
Memory is SBRAM/ZBT
C28
D28
0 - ZBT
1 – Pipeline SBRAM
Scan Speed
0 - ¼ SCLK(HPNA)
1 - SCLK
TSTOUT6
TSTOUT7
Reserved
E28
A27
Default: 128K x 32 or Memory Size
128K x 64 (1)
0 - 256K x 32 or 256K x 64
(4M total)
1 - 128K x 32 or 128K x 64
(2M total)
TSTOUT8
TSTOUT9
Default: Not Installed (1)
EEPROM Installed
B27
C27
0 - EEPROM installed
1 - EEPROM not installed
Default:
MCT
aging MCT Aging
enable (1)
0 - MCT aging disable
1 - MCT aging enable
Zarlink Semiconductor Inc.
89
MVTX2603
Data Sheet
Ball Signal Descriptions Table (continued)
TSTOUT10
Default:
FCB
aging FCB Aging
0 - FCB aging disable
D27
enable (1)
1 - FCB aging enable
TSTOUT11
Default: Timeout reset Timeout Reset
enable (1)
C26
0 - Time out reset disable
1 - Time out reset enable. Issue reset
if any state machine did not go back
to idle for 5 Sec.
TSTOUT12
TSTOUT13
Default: Normal (1)
Default: Single depth (1)
Default: (1)
Test Speed Up
D26
D25
0 - Enable test speed up. Do not use.
1 - Disable test speed up
FDB RAM depth (1 or 2 layers)
0 - Two layers
1 - One layer
TSTOUT14
TSTOUT15
Reserved. Leave unconnected
D24
E24
Default:
Normal SRAM Test Mode
operation
0 - Enable test mode
1 - Normal operation
G0_TXEN
Default: PCS
Giga0
T26
Mode: G0_TXEN G0_TXER
0
0
1
1
0
1
0
1
MII
2G
GMII
PCS
G0_TXER
G1_TXEN
Default: PCS
Default: PCS
R26
F26
Giga0
Mode: G1_TXEN G1_TXER
0
0
1
1
0
1
0
1
MII
2G
GMII
PCS
G1_TXER
Default: PCS
Default: RMII
E26
M[23:0]_TXEN
0 – GPSI
1 - RMII
AD29, AG28, AJ26, AE26,
AJ24, AE23, AJ22, AJ20, AE20,
AJ18, AJ21, AJ16, AJ14, AE14,
AJ12, AE11, AJ10, AJ8, AE8,
AJ6, AE5, AJ4, AG1, AE1,
90
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball Signal Descriptions Table (continued)
P_D[9]
Default: PLL Enable
PLL enable for LA_CLK and
LB_CLK.
C21
0 – Disable PLL, Use delay specified
by P_D[15:10] strap option
1 – Enable PLL
P_D[15:13]
Default: 111
Programmable delay for internal
OE_CLK from SCLK input when
PLL is disabled. The OE_CLK is
used for generating the OE0 and
OE1 signals
C19, B19, A19
Suggested value is 001.
P_D[12:10]
Default: 111
Programmable delay for LA_CLK
and LB_CLK from internal OE_CLK
when PLL is disabled. The LA_CLK
and LB_CLK delay from SCLK is the
sum of the delay programmed in
here and the delay in P_D[15:13].
C20, B20, A20
Suggested value is 011.
Notes:
# =
Active low signal
Input =
In-ST =
Output =
Out-OD=
I/O-TS =
I/O-OD =
Input signal
Input signal with Schmitt-Trigger
Output signal (Tri-State driver)
Output signal with Open-Drain driver
Input & Output signal with Tri-State driver
Input & Output signal with Open-Drain driver
14.3
Ball – Signal Name
Ball – Signal Name Table
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
A9
LA_D[63]
LA_D[62]
LA_D[61]
LA_D[60]
LA_D[59]
LA_D[58]
LA_D[57]
D3
LA_D[19]
LA_D[18]
LA_D[17]
LA_D[16]
LA_D[15]
LA_D[14]
LA_D[13]
LA_OE0#
LA_OE1#
LB_D[63]
LB_D[62]
LB_D[61]
LB_D[60]
LB_D[59]
D20
E3
D2
E2
A7
B7
A6
B9
F4
F5
G4
G5
H4
B21
D19
E19
D18
E18
D17
Zarlink Semiconductor Inc.
91
MVTX2603
Data Sheet
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
H5
LA_D[56]
LA_D[55]
LA_D[54]
LA_D[53]
LA_D[52]
LA_D[51]
LA_D[50]
LA_D[49]
LA_D[48]
LA_D[47]
LA_D[46]
LA_D[45]
LA_D[44]
LA_D[43]
LA_D[42]
LA_D[41]
LA_D[40]
LA_D[39]
LA_D[38]
LA_D[37]
LA_D[36]
LA_D[35]
LA_D[34]
LA_D[33]
LA_D[32]
LA_D[31]
LA_D[30]
LA_D[29]
LA_D[28]
LA_D[27]
B6
LA_D[12]
LA_D[11]
LA_D[10]
LA_D[9]
LA_D[8]
LA_D[7]
LA_D[6]
LA_D[5]
LA_D[4]
LA_D[3]
LA_D[2]
LA_D[1]
LA_D[0]
LA_A[20]
LA_A[19]
LA_A[18]
LA_A[17]
LA_A[16]
LA_A[15]
LA_A[14]
LA_A[13]
LA_A[12]
LA_A[11]
LA_A[10]
LA_A[9]
LA_A[8]
LA_A[7]
LA_A[6]
LA_A[5]
LA_A[4]
LB_D[58]
LB_D[57]
LB_D[56]
LB_D[55]
LB_D[54]
LB_D[53]
LB_D[52]
LB_D[51]
LB_D[50]
LB_D[49]
LB_D[48]
LB_D[47]
LB_D[46]
LB_D[45]
LB_D[44]
LB_D[43]
LB_D[42]
LB_D[41]
LB_D[40]
LB_D[39]
LB_D[38]
LB_D[37]
LB_D[36]
LB_D[35]
LB_D[34]
LB_D[33]
LB_D[32]
LB_D[31]
LB_D[30]
LB_D[29]
E17
C6
J4
D16
E16
D15
E15
D14
E14
D13
E13
D21
E21
A18
B18
C18
A17
B17
C17
A16
B16
C16
A15
B15
C15
A14
B14
D9
A5
J5
B5
K4
K5
L4
L5
M4
M5
N4
N5
G3
H1
H2
H3
J1
C5
A4
B4
C4
A3
B3
C3
B2
C2
C14
A13
B13
C13
A12
B12
C12
A11
B11
C11
D11
E11
A10
B10
D10
E10
A8
J2
J3
K1
K2
K3
L1
L2
L3
M1
M2
M3
U4
U5
V4
E9
D8
E8
D7
92
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
V5
LA_D[26]
LA_D[25]
LA_D[24]
LA_D[23]
LA_D[22]
LA_D[21]
LA_D[20]
LB_D[21]
LB_D[20]
LB_D[19]
LB_D[18]
LB_D[17]
LB_D[16]
LB_D[15]
LB_D[14]
LB_D[13]
LB_D[12]
LB_D[11]
LB_D[10]
LB_D[9]
LB_D[8]
LB_D[7]
LB_D[6]
C7
LA_A[3]
LB_D[28]
E7
B8
LA_ADSC#
LA_CLK
W4
LB_D[27]
D6
C1
W5
LB_D[26]
E6
C9
LA_WE#
Y4
LB_D[25]
D5
D12
LA_WE0#
Y5
LB_D[24]
E5
E12
LA_WE1#
AA4
LB_D[23]
D4
C8
LA_OE#
AA5
LB_D[22]
E4
U2
LB_OE1#
AH7
M[4]_RXD[0]
M[3]_RXD[0]
M[2]_RXD[0]
M[1]_RXD[0]
M[0]_RXD[0]
AB4
AB5
AC4
AC5
AD4
AD5
W1
R28
MDC
AE6
P28
MDIO
AH5
R29
M_CLK
AH2
AC29
AE28
AJ27
AF27
AJ25
AF24
AH23
AE19
AF21
AJ19
AF18
AJ17
AJ15
AF15
AJ13
AF12
AJ11
AJ9
M[23]_RXD[1]
M[22]_RXD[1]
M[21]_RXD[1]
M[20]_RXD[1]
M[19]_RXD[1]
M[18]_RXD[1]
M[17]_RXD[1]
M[16]_RXD[1]
M[15]_RXD[1]
M[14]_RXD[1]
M[13]_RXD[1]
M[12]_RXD[1]
M[11]_RXD[1]
M[10]_RXD[1]
M[9]_RXD[1]
M[8]_RXD[1]
M[7]_RXD[1]
M[6]_RXD[1]
M[5]_RXD[1]
AF2
AC27
AF29
AG27
AF26
AG25
AG23
AF23
AG21
AH21
AF19
AF17
AG17
AG15
AF14
AG13
AF11
AG11
AG9
M[23]_CRS_DV
M[22]_CRS_DV
M[21]_CRS_DV
M[20]_CRS_DV
M[19]_CRS_DV
M[18]_CRS_DV
M[17]_CRS_DV
M[16]_CRS_DV
M[15]_CRS_DV
M[14]_CRS_DV
M[13]_CRS_DV
M[12]_CRS_DV
M[11]_CRS_DV
M[10]_CRS_DV
M[9]_CRS_DV
M[8]_CRS_DV
M[7]_CRS_DV
M[6]_CRS_DV
Y1
Y2
Y3
AA1
AA2
AA3
AB1
AB2
AB3
AC1
AC2
AC3
AD1
AD2
AD3
N3
LB_D[5]
LB_D[4]
LB_D[3]
LB_D[2]
LB_D[1]
LB_D[0]
LB_A[20]
AF9
Zarlink Semiconductor Inc.
93
MVTX2603
Data Sheet
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
AF8
LB_A[19]
LB_A[18]
LB_A[17]
LB_A[16]
LB_A[15]
LB_A[14]
LB_A[13]
LB_A[12]
LB_A[11]
LB_A[10]
LB_A[9]
LB_A[8]
LB_A[7]
LB_A[6]
LB_A[5]
LB_A[4]
LB_A[3]
AJ7
M[4]_RXD[1]
M[3]_RXD[1]
M[2]_RXD[1]
M[1]_RXD[1]
M[0]_RXD[1]
M[23]_RXD[0]
M[22]_RXD[0]
M[21]_RXD[0]
M[20]_RXD[0]
M[19]_RXD[0]
M[18]_RXD[0]
M[17]_RXD[0]
M[16]_RXD[0]
M[15]_RXD[0]
M[14]_RXD[0]
M[13]_RXD[0]
M[12]_RXD[0]
M[11]_RXD[0]
M[10]_RXD[0]
M[9]_RXD[0]
M[8]_RXD[0]
M[7]_RXD[0]
M[6]_RXD[0]
M[5]_RXD[0]
M[6]_TXD[0]
M[5]_TXD[0]
M[4]_TXD[0]
M[3]_TXD[0]
M[2]_TXD[0]
M[1]_TXD[0]
M[5]_CRS_DV
N2
AF6
AG7
AF5
M[4]_CRS_DV
M[3]_CRS_DV
M[2]_CRS_DV
M[1]_CRS_DV
M[0]_CRS_DV
M[23]_TXEN
M[22]_TXEN
M[21]_TXEN
M[20]_TXEN
M[19]_TXEN
M[18]_TXEN
M[17]_TXEN
M[16]_TXEN
M[15]_TXEN
M[14]_TXEN
M[13]_TXEN
M[12]_TXEN
M[11]_TXEN
M[10]_TXEN
M[9]_TXEN
N1
P3
AJ5
AJ3
AG5
AH3
P2
AF1
P1
AC28
AF28
AH27
AE27
AH25
AE24
AF22
AF20
AE21
AH19
AH20
AH17
AH15
AE15
AH13
AE12
AH11
AH9
AF3
R5
R4
R3
R2
R1
T5
AD29
AG28
AJ26
AE26
AJ24
AE23
AJ22
AJ20
AE20
AJ18
AJ21
AJ16
AJ14
AE14
AJ12
AE11
AJ10
AJ8
T4
T3
T2
T1
W3
W2
V1
LB_ADSC#
LB_CLK
G1
V3
LB_WE#
LB_WE0#
LB_WE1#
LB_OE#
P4
M[8]_TXEN
P5
M[7]_TXEN
V2
LB_OE0#
M[5]_TXEN
M[4]_TXEN
M[3]_TXEN
M[2]_TXEN
M[1]_TXEN
M[0]_TXEN
AE9
M[6]_TXEN
U1
AE8
AJ6
AE5
AJ4
AG1
AE1
AH8
G27
M26_RXD[15]
M26_RXD[14]
M26_RXD[13]
M26_RXD[12]
M26_RXD[11]
M26_RXD[10]
AF7
H29
AH6
H28
AF4
H27
AH4
J29
AG2
J28
94
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
J27
M[23]_TXD[1]
AE2
M[0]_TXD[0]
M25_TXD[15]
M25_TXD[14]
M25_TXD[13]
M25_TXD[12]
M25_TXD[11]
M25_TXD[10]
M25_TXD[9]
M25_TXD[8]
M25_TXD[7]
M25_TXD[6]
M25_TXD[5]
M25_TXD[4]
M25_TXD[3]
M25_TXD[2]
M25_TXD[1]
M25_TXD[0]
M25_RXD[15]
M25_RXD[14]
M25_RXD[13]
M25_RXD[12]
M25_RXD[11]
M25_RXD[10]
M25_RXD[9]
M25_RXD[8]
M25_RXD[7]
M25_RXD[6]
M25_RXD[5]
M25_RXD[4]
M25_RXD[3]
M26_RXD[9]
M26_RXD[8]
M26_RXD[7]
M26_RXD[6]
M26_RXD[5]
M26_RXD[4]
M26_RXD[3]
M26_RXD[2]
M26_RXD[1]
M26_RXD[0]
M26_TXD[15]
M26_TXD[14]
M26_TXD[13]
M26_TXD[12]
M26_TXD[11]
M26_TXD[10]
M26_TXD[9]
M26_TXD[8]
M26_TXD[7]
M26_TXD[6]
M26_TXD[5]
M26_TXD[4]
M26_TXD[3]
M26_TXD[2]
M26_TXD[1]
M26_TXD[0]
M26_RX_DV
M26_RX_ER
M26_CRS
AD27
AH28
AG26
AE25
AG24
AE22
AJ23
AG20
AE18
AG18
AE16
AG16
AG14
AE13
AG12
AE10
AG10
AG8
M[22]_TXD[1]
M[21]_TXD[1]
M[20]_TXD[1]
M[19]_TXD[1]
M[18]_TXD[1]
M[17]_TXD[1]
M[16]_TXD[1]
M[15]_TXD[1]
M[14]_TXD[1]
M[13]_TXD[1]
M[12]_TXD[1]
M[11]_TXD[1]
M[10]_TXD[1]
M[9]_TXD[1]
M[8]_TXD[1]
M[7]_TXD[1]
M[6]_TXD[1]
M[5]_TXD[1]
M[4]_TXD[1]
M[3]_TXD[1]
M[2]_TXD[1]
M[1]_TXD[1]
M[0]_TXD[1]
M[23]_TXD[0]
M[22]_TXD[0]
M[21]_TXD[0]
M[20]_TXD[0]
M[19]_TXD[0]
M[18]_TXD[0]
U26
K29
K28
K27
L29
L28
L27
M29
M28
M27
G26
G25
H26
H25
J26
U25
V26
V25
W26
W25
Y27
Y26
AA26
AA25
AB26
AB25
AC26
AC25
AD26
AD25
U27
J25
K25
K26
M25
L26
M26
L25
N26
N25
P26
P25
F28
G28
E25
G29
V29
AE7
V28
AG6
V27
AE4
W29
W28
W27
Y29
AG4
AG3
AE3
AD28
AG29
AH26
AF25
AH24
AG22
Y28
Y25
AA29
AA28
AA27
M26_COL
Zarlink Semiconductor Inc.
95
MVTX2603
Data Sheet
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
F29
M[17]_TXD[0]
AB29
AB28
AB27
R26
T25
T26
T28
U28
R25
U29
T29
U18
V12
V13
V14
V15
V16
V17
V18
N14
N15
N16
N17
N18
P12
P13
P14
P15
P16
C19
M25_RXD[2]
M25_RXD[1]
M25_RXD[0]
M25_TX_ER
M25_TXCLK
M25_TX_EN
M25_RX_DV
M25_RX_ER
M25_CRS
M25_COL
M25_RXCLK
VSS
M26_RXCLK
M26_TX_EN
M26_TX_ER
M26_TXCLK
AH22
AE17
AG19
AH18
AF16
AH16
AH14
AF13
AH12
AF10
AH10
B27
M[16]_TXD[0]
F26
E26
F25
E24
D24
D25
D26
C26
D27
C27
N12
N13
K17
K18
M10
N10
M20
N20
U10
V10
U20
V20
Y12
Y13
Y17
Y18
K12
K13
M16
M[15]_TXD[0]
M[14]_TXD[0]
M[13]_TXD[0]
BIST_DONE/TSTOUT[15]
M[12]_TXD[0]
BIST_IN_PRC/TST0UT[14]
M[11]_TXD[0]
MCT_ERR/TSTOUT[13]
M[10]_TXD[0]
FCB_ERR/TSTOUT[12]
M[9]_TXD[0]
CHECKSUM_OK/TSTOUT[11]
M[8]_TXD[0]
INIT_START/TSTOUT[10]
M[7]_TXD[0]
INIT_DONE/TSTOUT[9]
G2_LINK#/TSTOUT[8]
G2_DPCOL#/TSTOUT[7]
G2_RXTX#/TSTOUT[6]
G1_LINK#/TSTOUT[5]
G1_DPCOL#/TSTOUT[4]
G1_RXTX#/TSTOUT[3]
LED_BIT/TSTOUT[2]
LED_SYN/TSTOUT[1]
LED_CLK/TSTOUT[0]
GREF_CLK1
VSS
VSS
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VSS
VSS
A27
VSS
E28
VSS
D28
C28
B28
VSS
VSS
VSS
E29
VSS
D29
C29
N29
P29
VSS
VSS
GREF_CLK0
VSS
SCAN_EN
VSS
F3
SCLK
VSS
E1
T_MODE0
VSS
U3
T_MODE1
VSS
C10
B24
TRUNK2
VSS
TRUNK1
VSS
A21
TRUNK0
VSS
C22
A26
STROBE
RESERVED
96
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
Ball – Signal Name Table (continued)
Ball
No.
Signal
Name
Ball
No.
Signal
Name
Signal Name
Ball No.
M17
D0
B19
RESERVED
RESERVED
VSS
VSS
B26
AUTOFD
SCL
A19
R13
R14
R15
R16
R17
R18
T12
T13
T14
T15
T16
M18
F16
F17
N6
VSS
C25
A24
A25
F1
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VDD33
VSS
SDA
VSS
AVCC
VSS
AGND
SCANCOL
SCANLINK
VSS
P6
D1
VSS
R6
D22
E23
E27
N28
N27
F2
VSS
T6
SCANMODE
VSS
U6
VSS
N24
P24
R24
T24
U24
AD13
AD14
AD15
AD16
AD17
F13
F14
F15
R12
B25
E20
P18
VSS
RESIN#
VSS
RESETOUT_
VSS
G2
VSS
B22
A22
C23
B23
A23
C24
D23
T27
F27
C20
B20
A20
C21
T17
T18
U12
U13
U14
RESERVED
RESERVED
VSS
RESERVED
RESERVED
RESERVED
RESERVED
SCANCLK
VSS
VSS
VSS
VSS
U15
U16
VSS
M25_MTXCLK
M26_MTXCLK
RESERVED
RESERVED
RESERVED
RESERVED
U17
M12
M13
M14
M15
P17
VSS
VSS
VSS
VSS
RESERVED
RESERVED
VSS
VSS
VSS
14.4
AC/DC Timing
14.4.1 Absolute Maximum Ratings
Storage Temperature
-65°C to +150°C
Zarlink Semiconductor Inc.
97
MVTX2603
Data Sheet
Operating Temperature
-40°C to +85°C
Supply Voltage VDD33 with Respect to V
+3.0 V to +3.6 V
SS
Supply Voltage VDD with Respect to V
Voltage on Input Pins
+2.38 V to +2.75 V
-0.5 V to (VDD33 + 0.3 V)
SS
Caution: Stress above those listed may damage the device. Exposure to the Absolute Maximum Ratings for
extended periods may affect device reliability. Functionality at or above these limits is not implied.
14.4.2 DC Electrical Characteristics
VDD33 = 3.0 V to 3.6 V (3.3v +/- 10%)
T
= -40°C to +85°C
AMBIENT
VDD = 2.5V +10% - 5%
14.4.3 Recommended Operation Conditions
Recommended Operation Conditions Table
Preliminary
Symbol
Parameter Description
Min
Typ
100
Max
Unit
f
I
I
Frequency of Operation
MHz
mA
mA
V
osc
Supply Current – @ 100 MHz (VDD33 =3.3 V)
Supply Current – @ 100 MHz (VDD =2.5 V)
Output High Voltage (CMOS)
450
DD1
DD2
1500
V
V
V
VDD33 - 0.5
OH
Output Low Voltage (CMOS)
0.5
V
OL
Input High Voltage (TTL 5V tolerant)
VDD33 x
70%
VDD33 +
2.0
V
IH-TTL
V
Input Low Voltage (TTL 5V tolerant)
VDD33 x
30%
V
IL-TTL
I
Input Leakage Current (0.1 V < V < VDD33) (all
10
µA
IH-5VT
IN
pins except those with internal pull-up/pull-down
resistors)
C
C
C
Input Capacitance
5
pF
IN
Output Capacitance
5
pF
OUT
I/O
I/O Capacitance
7
pF
θ
θ
θ
Thermal resistance with 0 air flow
Thermal resistance with 1 m/s air flow
Thermal resistance with 2m/s air flow
11.2
10.2
8.9
C/W
C/W
C/W
ja
ja
ja
14.5
Local Frame Buffer SBRAM Memory Interface
14.5.1 Local SBRAM Memory Interface
98
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
LA_CLK
L1
L2
LA_D[63:0]
Figure 20 - Local Memory Interface – Input setup and hold timing
LA_CLK
L3-max
L3-min
LA_D[63:0]
L4-max
L4-min
LA_A[20:3]
L6-max
L6-min
LA_ADSC#
L7-max
L7-min
LA_WE[1:0]#
L8-max
L8-min
LA_OE[1:0]#
L9-max
L9-min
LA_WE#
L10-max
L10-min
LA_OE#
Figure 21 - Local Memory Interface - Output valid delay timing
Zarlink Semiconductor Inc.
99
MVTX2603
Data Sheet
-100MHz
Symbol
Parameter
Min (ns)
Max (ns)
Note
L1
L2
L3
L4
L6
L7
L8
L9
L10
LA_D[63:0] input set-up time
LA_D[63:0] input hold time
LA_D[63:0] output valid delay
LA_A[20:3] output valid delay
LA_ADSC# output valid delay
LA_WE[1:0]#output valid delay
LA_OE[1:0]# output valid delay
LA_WE# output valid delay
LA_OE# output valid delay
4
1.5
1.5
2
7
7
7
7
1
7
5
C = 25pf
L
C = 30pf
L
1
C = 30pf
L
1
C = 25pf
L
-1
1
C = 25pf
L
C = 25pf
L
1
C = 25pf
L
Table 13 - AC Characteristics – Local frame buffer SBRAM Memory Interface
14.6
Local Switch Database SBRAM Memory Interface
14.6.1 Local SBRAM Memory Interface:
LB_CLK
L1
L2
LB_D[63:0]
Figure 22 - Local Memory Interface – Input setup and hold timing
100
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
LB_CLK
LB_D[31:0]
LB_A[21:2]
L3-max
L3-min
L4-max
L4-min
L6-max
L6-min
LB_ADSC#
L8-max
L8-min
LB_WE[1:0]#
L9-max
L9-min
LB_OE[1:0]#
L10-max
L10-min
LB_WE#
LB_OE#
L11-max
L11-min
Figure 23 - Local Memory Interface - Output valid delay timing
-100MHz
Symbol
Parameter
Min (ns)
Max (ns)
Note
L1
L2
LB_D[63:0] input set-up time
LB_D[63:0] input hold time
LB_D[63:0] output valid delay
LB_A[20:3] output valid delay
LB_ADSC# output valid delay
LB_WE[1:0]#output valid delay
LB_OE[1:0]# output valid delay
LB_WE# output valid delay
LB_OE# output valid delay
4
1.5
1.5
2
L3
7
7
7
7
1
7
5
C = 25pf
L
L4
C = 30pf
L
L6
1
C = 30pf
L
L8
1
C = 25pf
L
L9
-1
1
C = 25pf
L
L10
L11
C = 25pf
L
1
C = 25pf
L
Table 14 - AC Characteristics – Local Switch Database SBRAM Memory Interface
Zarlink Semiconductor Inc.
101
MVTX2603
Data Sheet
14.7
AC Characteristics
14.7.1 Reduced Media Independent Interface
M_CLKI
M[23:0]_TXEN
M6-max
M6-min
M7-max
M7-min
M[23:0] _TXD[1:0]
Figure 24 - AC Characteristics – Reduced Media Independent Interface
M_CLKI
M2
M[23:0]_RXD
M3
M4
M[23:0]_CRS_DV
M5
Figure 25 - AC Characteristics – Reduced Media Independent Interface
-50MHz
Symbol
Parameter
Note
Min (ns)
Max (ns)
M2
M3
M4
M5
M6
M7
M[23:0]_RXD[1:0] Input Setup Time
M[23:0]_RXD[1:0] Input Hold Time
M[23:0]_CRS_DV Input Setup Time
M[23:0]_CRS_DV Input Hold Time
M[23:0]_TXEN Output Delay Time
M[23:0]_TXD[1:0] Output Delay Time
4
1
4
1
2
2
11
11
C = 20 pF
L
C = 20 pF
L
Table 15 - AC Characteristics – Reduced Media Independent Interface
102
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
M25_TXCLK
M25_TXD [15:0]
M25_TX_EN]
M25_TX_ER
G12-max
G12-min
G13-max
G13-min
G14-max
G14-min
Figure 26 - AC Characteristics- GMII
M25_RXCLK
G1
G2
M25_RXD[15:0]
G3
G4
M25_RX_DV
G5
G6
M25_RX_ER
G7
G8
M25_RX_CRS
Figure 27 - AC Characteristics – Gigabit Media Independent Interface
-125Mhz
Symbol
Parameter
Note
Min (ns)
Max (ns)
G1
G2
G3
G4
G5
G6
G7
G8
M[25]_RXD[15:0] Input Setup Times
M[25]_RXD[15:0] Input Hold Times
M[25]_RX_DV Input Setup Times
M[25]_RX_DV Input Hold Times
M[25]_RX_ER Input Setup Times
M[25]_RX_ER Input Hold Times
M[25]_CRS Input Setup Times
M[25]_CRS Input Hold Times
2
1
2
1
2
1
2
1
Figure 28 - AC Characteristics – Gigabit Media Independent Interface
Zarlink Semiconductor Inc.
103
MVTX2603
Data Sheet
-125Mhz
Symbol
Parameter
Note
C = 20pf
Min (ns)
Max (ns)
G12
G13
G14
M[25]_TXD[15:0] Output Delay Times
M[25]_TX_EN Output Delay Times
M[25]_TX_ER Output Delay Times
1
1
1
6
6.5
6
L
C = 20pf
L
C = 20pf
L
Figure 28 - AC Characteristics – Gigabit Media Independent Interface (continued)
M25_TXCLK
TIMIN
M25_TXD [9:0]
TIMAX
Figure 29 - Gigabit TBI Interface Transmit Timing
M25_RXCLK
M25_COL
T2
T2
M25_RXD[9:0]
T3
T3
Figure 30 - Gigabit TBI Interface Receive Timing
Symbol
Parameter
Min (ns)
Max (ns)
Note
T1
M25_TXD[9:0] Output Delay Time
1
6
C = 20pf
L
Table 16 - Output Delay Timing
Symbol
Parameter
Min (ns)
Max (ns)
Note
T2
T3
M25_RXD[9:0] Input Setup Time
M25_RXD[9:0] Input Hold Time
3
3
Table 17 - Input Setup Timing
104
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
M26_TXCLK
M26_TXD [15:0]
M26_TX_EN]
M26_TX_ER
G12-max
G12-min
G13-max
G13-min
G14-max
G14-min
Figure 31 - AC Characteristics- GMII
M26_RXCLK
G1
G3
G5
G7
G2
G4
M26_RXD[15:0]
M26_RX_DV
M26_RX_ER
M26_RX_CRS
G6
G8
Figure 32 - AC Characteristics – Gigabit Media Independent Interface
-125Mhz
Symbol
Parameter
Min (ns)
Max (ns)
Note
G1
G2
G3
G4
G5
G6
G7
M[26]_RXD[15:0] Input Setup Times
M[26]_RXD[15:0] Input Hold Times
M[26]_RX_DV Input Setup Times
M[26]_RX_DV Input Hold Times
M[26]_RX_ER Input Setup Times
M[26]_RX_ER Input Hold Times
M[26]_CRS Input Setup Times
2
1
2
1
2
1
2
Table 18 - AC Characteristics – Gigabit Media Independent Interface
Zarlink Semiconductor Inc.
105
MVTX2603
Data Sheet
-125Mhz
Symbol
Parameter
Min (ns)
Max (ns)
Note
G8
M[26]_CRS Input Hold Times
1
1
1
1
G12
G13
G14
M[26]_TXD[15:0] Output Delay Times
M[26]_TX_EN Output Delay Times
M[26]_TX_ER Output Delay Times
6
6.5
6
C = 20pf
L
C = 20pf
L
C = 20pf
L
Table 18 - AC Characteristics – Gigabit Media Independent Interface (continued)
M26_TXCLK
TIMIN
M26_TXD [9:0]
TIMAX
Figure 33 - Gigabit TBI Interface Transmit Timing
M26_RXCLK
M26_COL
T2
T2
M26_RXD[9:0]
T3
T3
Figure 34 - Gigabit TBI Interface Timing
Symbol
Parameter
M26_TXD[9:0] Output Delay Time
Min (ns)
Max (ns)
Note:
T1
1
6
C = 20pf
L
Table 19 - Output Delay Timing
Symbol
Parameter
Min (ns)
Max (ns)
Note
T2
T3
M26_RXD[9:0] Input Setup Time
M26_RXD[9:0] Input Hold Time
3
3
Table 20 - Input Setup Timing
106
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
14.7.2 LED Interface
LED_CLK
LED_SYN
LED_BIT
LE5-max
LE5-min
LE6-max
LE6-min
Figure 35 - AC Characteristics – LED Interface
Variable FREQ.
Parameter
Symbol
Note
Min (ns)
Max (ns)
LE5
LE6
LED_SYN Output Valid Delay
LED_BIT Output Valid Delay
-1
-1
7
7
C = 30pf
L
C = 30pf
L
Table 21 - AC Characteristics – LED Interface
14.7.3 SCANLINK SCANCOL Output Delay Timing
SCANCLK
C5-max
C5-min
SCANLINK
C7-max
C7-min
SCANCOL
Figure 36 - SCANLINK SCANCOL Output Delay Timing
SCANCLK
C1
C2
SCANLINK
C3
C4
SCANCOL
Figure 37 - SCANLINK, SCANCOL Setup Timing
Zarlink Semiconductor Inc.
107
MVTX2603
Data Sheet
-25MHz
Symbol
Parameter
Note:
Min (ns)
Max (ns)
C1
C2
C3
C4
C5
C7
SCANLINK input set-up time
SCANLINK input hold time
SCANCOL input setup time
SCANCOL input hold time
SCANLINK output valid delay
SCANCOL output valid delay
20
2
20
1
0
10
10
C = 30pf
L
0
C = 30pf
L
Table 22 - SCANLINK, SCANCOL Timing
14.7.4 MDIO Input Setup and Hold Timing
MDC
D1
D2
MDIO
Figure 38 - MDIO Input Setup and Hold Timing
MDC
D3-max
D3-min
MDIO
Figure 39 - MDIO Output Delay Timing
1MHz
Symbol
Parameter
Note
Min (ns)
Max (ns)
D1
D2
D3
MDIO input setup time
MDIO input hold time
MDIO output delay time
10
2
1
20
C = 50pf
L
Table 23 - MDIO Timing
108
Zarlink Semiconductor Inc.
Data Sheet
MVTX2603
2
14.7.5 I C Input Setup Timing
SCL
SDA
S2
S1
Figure 40 - I2C Input Setup Timing
SCL
S3-max
S3-min
SDA
Figure 41 - I2C Output Delay Timing
50KHz
Symbol
Parameter
Note
Min (ns)
Max (ns)
S1
S2
SDA input setup time
SDA input hold time
SDA output delay time
20
1
S3*
4 usec
6 usec
C = 30pf
L
* Open Drain Output. Low to High transistor is controlled by external pullup resistor.
Table 24 - I2C Timing
Zarlink Semiconductor Inc.
109
MVTX2603
Data Sheet
14.7.6 Serial Interface Setup Timing
STROBE
D0
D4
D5
D1
D1
D2
D2
Figure 42 - Serial Interface Setup Timing
STROBE
D3-max
D3-min
AutoFd
Figure 43 - Serial Interface Output Delay Timing
Symbol
Parameter
Min (ns)
Max (ns)
Note
D1
D2
D3
D4
D5
D0 setup time
D0 hold time
20
3µs
1
AutoFd output delay time
Strobe low time
50
C = 100pf
L
5µs
5µs
Strobe high time
Table 25 - Serial Interface Timing
110
Zarlink Semiconductor Inc.
For more information about all Zarlink products
visit our Web Site at
www.zarlink.com
Information relating to products and services furnished herein by Zarlink Semiconductor Inc. trading as Zarlink Semiconductor or its subsidiaries (collectively
“Zarlink”) is believed to be reliable. However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the
application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may
result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under
patents or other intellectual property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified
that the use of product in certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property
rights owned by Zarlink.
This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part
of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other
information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the
capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and
suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does
not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in
significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request.
Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in an I2C System, provided that the system
conforms to the I2C Standard Specification as defined by Philips.
Zarlink and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright 2002, Zarlink Semiconductor Inc. All Rights Reserved.
TECHNICAL DOCUMENTATION - NOT FOR RESALE
相关型号:
MVTX2603AG
DATACOM, LAN SWITCHING CIRCUIT, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, MS-034, HSBGA-553
MICROSEMI
MVTX2603AG2
DATACOM, LAN SWITCHING CIRCUIT, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, LEAD FREE, MS-034, HSBGA-553
MICROSEMI
MVTX2604AG2
LAN Switching Circuit, CMOS, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, LEAD FREE, MS-034, HSBGA-553
ZARLINK
©2020 ICPDF网 联系我们和版权申明