TFS468G [VECTRON]

Filter specification; 过滤器规格
TFS468G
型号: TFS468G
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器
文件: 总5页 (文件大小:270K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 468g.doc  
Version 1.1  
27.06.2006  
VI TELEFILTER  
Filter specification  
TFS 468G  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
490 || -4,3 pF  
680 || -4,2 pF  
Output:  
Characteristics  
Remark:  
The nominal frequency f is fixed at 468,0 MHz. The insertion loss a is defined as loss value determined at f Reference level for the relative  
N
e
N.  
attenuation a of the TFS 468G is the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the  
rel  
e
c
dB filter attenuation level relative to the insertion loss a . All specified data are met within the operating temperature range.  
e
D a t a  
typ. value  
tolerance / limit  
a
= a  
min  
10,2  
dB  
max.  
14,0  
dB  
Insertion loss  
e
(reference level)  
fN  
-
468,0  
fN ± 4,5  
1,0  
MHz  
MHz  
dB  
Nominal frequency  
Passband  
PB  
-
0,5  
dB  
max.  
Pass band ripple  
a
Relative attenuation  
rel  
f
f
±
±
4,5  
5
MHz  
MHz  
0,5  
2,1  
dB  
dB  
max.  
max.  
1
2,5  
dB  
dB  
fNN  
±
4,5  
7
MHz  
fNN  
f
±
±
±
-
MHz  
MHz  
MHz  
MHz  
MHz  
f
±
±
±
-
12  
20  
30  
30  
532  
MHz  
MHz  
MHz  
MHz  
MHz  
22  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
15  
35  
40  
50  
50  
dB  
dB  
dB  
dB  
dB  
fN  
fN  
fN  
fNN  
12  
fN  
fN  
fN  
fNN  
40  
48  
54  
55  
20  
438  
30  
+
+
0,47  
µs  
ns  
dB  
max.  
max.  
min.  
3,0  
250  
8
µs  
Absolute group delay wihhin PB  
Group delay ripple within fN ± 5 MHz  
Return loss within PB  
120  
12  
-
ns  
dB  
max.  
15  
dBm  
Input power level  
OTR  
-
-
- 40 °C ... + 85°C  
- 45 °C ... + 85°C  
Operating temperature range  
Storage temperature range  
TC **  
-18  
ppm/K  
Temperature coefficient of frequency  
f
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference  
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
**) f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).  
f
cat  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 468g.doc  
Version 1.1  
27.06.2006  
VI TELEFILTER  
Filter specification  
TFS 468G  
2/5  
Filter characteristic  
0
0
-1  
2.33  
2.12  
1.91  
1.7  
-8  
-16  
-24  
-32  
-40  
-48  
-56  
-64  
-72  
-80  
-2  
-3  
-4  
1.49  
1.28  
1.07  
0.86  
0.65  
0.44  
-5  
-6  
-7  
-8  
-9  
-10  
0.23  
474  
5
105  
205  
305  
405  
505  
605  
705  
805  
905  
1005  
462  
463.2  
464.4  
465.6  
466.8  
468  
469.2  
470.4  
471.6  
472.8  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
9
7
1
2
3
4
Ground  
Ground  
Ground  
Output  
Ground  
6
10  
12  
S 468G  
U26  
5
6
7
Output RF Return  
Ground  
8
9
Ground  
Ground  
1
3
Date code  
10  
11  
12  
Input  
Ground  
Input RF Return  
0,6  
1
Date code: Year + week  
U
V
W
...  
2006  
2007  
2008  
1
2,54  
7 ,0 +/-0,2  
50 Test circuit  
10  
12  
4
L3  
L1  
SAW  
L4  
L2  
C2  
C1  
6
1, 2, 3, 5, 7, 8, 9, 11  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 468g.doc  
Version 1.1  
27.06.2006  
VI TELEFILTER  
Filter specification  
TFS 468G  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
3000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
: 16,00 ± 0,3  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
7,50 ± 0,1  
0,60  
2,00 ± 0,1  
8,00 ± 0,1  
1,50  
Ko  
Typ  
PIN Marker  
D1  
Ao  
5,50 ± 0,1  
7,50 ± 0,1  
Ct  
: 13,5 ± 0,1  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 16,4 +2/-0  
W2(max) : 22,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 468g.doc  
Version 1.1  
27.06.2006  
VI TELEFILTER  
Filter specification  
TFS 468G  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 468g.doc  
Version 1.1  
27.06.2006  
VI TELEFILTER  
Filter specification  
TFS 468G  
5/5  
History  
Version Reason of Changes  
Name  
Date  
1.0  
1.1  
- specification gerated  
Pfeiffer  
Pfeiffer  
29.03.2006  
27.06.2006  
- terminating impedance corrected  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS468L

Filter specification
VECTRON

TFS468L_08

Filter specification
VECTRON

TFS468M

Filter specification
VECTRON

TFS469

Specification
VECTRON

TFS471

Filter Specification
VECTRON

TFS471A

Filter Specification
VECTRON

TFS471A1

Filter Specification
VECTRON

TFS471B

Filter specification
VECTRON

TFS471C

Filter Specification
VECTRON

TFS471D

Filter specification
VECTRON

TFS482

Filter specification
VECTRON

TFS491A

Filter specification
VECTRON