TFS468G [VECTRON]
Filter specification; 过滤器规格型号: | TFS468G |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:270K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 468g.doc
Version 1.1
27.06.2006
VI TELEFILTER
Filter specification
TFS 468G
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
490 Ω || -4,3 pF
680 Ω || -4,2 pF
Output:
Characteristics
Remark:
The nominal frequency f is fixed at 468,0 MHz. The insertion loss a is defined as loss value determined at f Reference level for the relative
N
e
N.
attenuation a of the TFS 468G is the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the
rel
e
c
dB filter attenuation level relative to the insertion loss a . All specified data are met within the operating temperature range.
e
D a t a
typ. value
tolerance / limit
a
= a
min
10,2
dB
max.
14,0
dB
Insertion loss
e
(reference level)
fN
-
468,0
fN ± 4,5
1,0
MHz
MHz
dB
Nominal frequency
Passband
PB
-
0,5
dB
max.
Pass band ripple
a
Relative attenuation
rel
f
…
…
f
±
±
4,5
5
MHz
MHz
0,5
2,1
dB
dB
max.
max.
1
2,5
dB
dB
fNN
±
4,5
7
MHz
fNN
f
±
±
±
-
MHz
MHz
MHz
MHz
MHz
…
…
…
…
…
f
±
±
±
-
12
20
30
30
532
MHz
MHz
MHz
MHz
MHz
22
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
15
35
40
50
50
dB
dB
dB
dB
dB
fN
fN
fN
fNN
12
fN
fN
fN
fNN
40
48
54
55
20
438
30
+
+
0,47
µs
ns
dB
max.
max.
min.
3,0
250
8
µs
Absolute group delay wihhin PB
Group delay ripple within fN ± 5 MHz
Return loss within PB
120
12
-
ns
dB
max.
15
dBm
Input power level
OTR
-
-
- 40 °C ... + 85°C
- 45 °C ... + 85°C
Operating temperature range
Storage temperature range
TC **
-18
ppm/K
Temperature coefficient of frequency
f
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).
f
cat
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
27.06.2006
VI TELEFILTER
Filter specification
TFS 468G
2/5
Filter characteristic
0
0
-1
2.33
2.12
1.91
1.7
-8
-16
-24
-32
-40
-48
-56
-64
-72
-80
-2
-3
-4
1.49
1.28
1.07
0.86
0.65
0.44
-5
-6
-7
-8
-9
-10
0.23
474
5
105
205
305
405
505
605
705
805
905
1005
462
463.2
464.4
465.6
466.8
468
469.2
470.4
471.6
472.8
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
9
7
1
2
3
4
Ground
Ground
Ground
Output
Ground
6
10
12
S 468G
U26
5
●
6
7
Output RF Return
Ground
8
9
Ground
Ground
1
3
Date code
10
11
12
Input
Ground
Input RF Return
0,6
1
Date code: Year + week
U
V
W
...
2006
2007
2008
1
2,54
7 ,0 +/-0,2
50 Ω Test circuit
10
12
4
L3
L1
SAW
L4
L2
C2
C1
6
1, 2, 3, 5, 7, 8, 9, 11
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
27.06.2006
VI TELEFILTER
Filter specification
TFS 468G
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
: 16,00 ± 0,3
Po
P2
t
Do
Po
Do
E
F
G(min)
P2
P1
D1(min)
Ao
Bo
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
7,50 ± 0,1
0,60
2,00 ± 0,1
8,00 ± 0,1
1,50
Ko
Typ
PIN Marker
D1
Ao
5,50 ± 0,1
7,50 ± 0,1
Ct
: 13,5 ± 0,1
W
2
Reel (all dimensions in mm)
A
:330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
C
: 50
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
27.06.2006
VI TELEFILTER
Filter specification
TFS 468G
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
27.06.2006
VI TELEFILTER
Filter specification
TFS 468G
5/5
History
Version Reason of Changes
Name
Date
1.0
1.1
- specification gerated
Pfeiffer
Pfeiffer
29.03.2006
27.06.2006
- terminating impedance corrected
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明