TFS491A [VECTRON]

Filter specification; 过滤器规格
TFS491A
型号: TFS491A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:160K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 491A.doc  
Version 1.1  
06.06.2006  
VI TELEFILTER  
Filter specification  
TFS 491A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance:  
Input:  
23  
0
°C  
dBm  
150  
150 Ω  
Output:  
Characteristics  
Remark:  
The nominal frequency f is fixed at 491,52 MHz. The insertion loss a is defined as loss value determined at f Reference level for the relative  
N
e
N.  
attenuation a of the TFS 491A is the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the  
rel  
e
c
dB filter attenuation level relative to the insertion loss a . All specified data are met within the operating temperature range.  
e
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
a
2,4  
dB  
4,5  
dB  
e
(reference level)  
Nominal frequency  
Centre frequency  
fN  
-
491,52 MHz  
-
fC  
491,90  
MHz  
MHz  
Bandwidth  
BW  
3
dB  
17,83  
-
Relative attenuation  
a
rel  
61,44 MHz  
91,52 MHz  
61,44 MHz  
fN  
fN  
-
-
91,52 MHz  
61,44 MHz  
1000,00 MHz  
52  
52  
55,5  
dB  
dB  
dB  
min.  
min.  
min.  
50  
46  
50  
dB  
dB  
dB  
fN  
fN  
-
+
@
@
@
@
@
122,88 MHz  
245,76 MHz  
368,64 MHz  
614,40 MHz  
737,28 MHz  
66,3  
64  
66,6  
64  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
60  
60  
55  
55  
54  
dB  
dB  
dB  
dB  
dB  
62,6  
Operating temperature range  
Storage temperature range  
OTR  
-
-
- 40 °C ... + 85°C  
- 45 °C ... + 95°C  
Temperature coefficient of frequency  
TC  
*
-73  
ppm/K  
f
*) f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).  
f
To  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 491A.doc  
Version 1.1  
06.06.2006  
VI TELEFILTER  
Filter specification  
TFS 491A  
2/5  
Filter characteristic  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
-80  
-90  
-100  
0
-0.5  
-1  
-1.5  
-2  
-2.5  
-3  
-3.5  
-4  
-4.5  
-5  
0
200  
400  
600  
800  
1000  
480  
485  
490  
495  
500  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
7
6
5
1
2
3
4
5
6
7
8
Ground  
Input  
Ground  
Ground  
Ground  
Output  
Ground  
Ground  
491A  
U23  
4
8
3
1
2
Date code  
1
3
Date code: Year + week  
6
U
V
2006  
2007  
2008  
0
G
rd  
W
...  
.
7
5
0,6  
0,6  
150 Test circuit  
L1  
2
6
L2  
SAW  
1, 3, 4, 5, 7, 8  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 491A.doc  
Version 1.1  
06.06.2006  
VI TELEFILTER  
Filter specification  
TFS 491A  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: three times max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
9000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3  
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
3,50 ± 0,05  
0,75  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
2,00 ± 0,05  
4,00 ± 0,1  
1,50  
3,25 ± 0,1  
3,25 ± 0,1  
5,5 ± 0,1  
Ko  
Typ  
PIN Marker  
D1  
Ao  
Ct  
W
2
Reel (all dimensions in mm)  
A
W1  
:330  
: 8,4 +1,5/-0  
W2(max) : 14,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 491A.doc  
Version 1.1  
06.06.2006  
VI TELEFILTER  
Filter specification  
TFS 491A  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 491A.doc  
Version 1.1  
06.06.2006  
VI TELEFILTER  
Filter specification  
TFS 491A  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of development specification  
Name  
Date  
Alawneh  
Channaa  
23.03.2006  
06.06.2006  
1.1  
- Add typical values, change attenuation  
- Add filter characteristic, generation of filter specification  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS498

Filter specification
VECTRON

TFS500

Filter specification
VECTRON

TFS500A

Filter specification
VECTRON

TFS506

Filter specification
VECTRON

TFS52

Minimum of the pass band attenuation
VECTRON

TFS520A

Filter specification
VECTRON

TFS520B

Filter specification
VECTRON

TFS522

Filter specification
VECTRON

TFS525

Preliminary specification
VECTRON

TFS533

Filter specification
VECTRON

TFS533_06

Filter specification
VECTRON

TFS537

VI TELEFILTER
VECTRON