PXI-2597 [NI]

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches; 26.5 GHz的多路复用器,单刀双掷继电器和转换开关
PXI-2597
型号: PXI-2597
厂家: National Instruments    National Instruments
描述:

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
26.5 GHz的多路复用器,单刀双掷继电器和转换开关

复用器 开关 继电器 光电二极管
文件: 总4页 (文件大小:273K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches  
NI PXI-2596, NI PXI-2597, NI PXI-2598, NI PXI-2599  
• 26.5 GHz bandwidth  
electromechanical relays  
Operating Systems  
• Windows 2000/NT/XP  
• 50  
characteristic impedance  
Recommended Software  
• NI Switch Executive  
• LabVIEW  
• LabWindows/CVI  
• Measurement Studio  
• Onboard relay counting  
• Fully software programmable  
• Configurations  
• PXI-2596 – dual 6x1 unterminated  
multiplexer (SP6T)  
• PXI-2597 – 6x1 terminated  
multiplexer (SP6T)  
Other Compatible Software  
• Visual Basic  
• PXI-2598 – dual transfer switch  
• C/C++  
• PXI-2599 – dual SPDT  
(Form C) relays  
• Modules designed using microwave  
relays from Radiall  
Driver/Services Software  
(included)  
• NI-SWITCH  
• NI-DAQmx  
Overview and Applications  
Software  
The National Instruments PXI-2596, PXI-2597, PXI-2598, and PXI-2599  
multiplexers, SPDT relays, and transfer switch modules route RF or  
microwave signals in automated test applications. While designed to  
operate with less than 1 dB insertion loss up to 26.5 GHz, they appear  
almost invisible to signals at much lower frequencies as well. Use the  
NI PXI-2597 terminated multiplexer when high-power signal reflections are  
All National Instruments PXI switch modules are shipped with NI-SWITCH,  
an IVI-compliant driver offering complete functionality for all switch  
modules. For additional assistance in configuring, programming, and  
managing higher-channel-count switching systems, NI Switch Executive  
software offers an easy-to-use, intelligent switch management and visual  
routing environment. With the latest version of NI Switch Executive, you  
can store calibration information for your RF/microwave switch routes on a  
per-path basis. Use the NI-SWITCH Soft Front Panel for simple relay  
a concern and 50  
terminations are required. The PXI-2596 offers a  
higher-density, unterminated option with dual 6x1 multiplexer banks in the  
same module. The PXI-2598 and PXI-2599 operate as transfer switches and operations or debugging switch code/execution.  
SPDT relays, respectively, for basic signal routing or inserting and  
removing components in a signal path. These modules are also well-suited  
for passing high-order harmonics from RF upconverters such as the  
NI PXI-5670 2.7 GHz RF vector signal generator or routing multiple sources to  
RF downconverters such as the NI PXI-5660 2.7 GHz RF vector signal analyzer.  
Ordering Information  
NI PXI-2596............................................................................778572-96  
NI PXI-2597............................................................................778572-97  
NI PXI-2598............................................................................778572-98  
NI PXI-2599............................................................................778572-99  
Includes NI-SWITCH and NI-DAQmx driver software.  
Relay Count Tracking  
The switches count relay closures on each of their individual relays.  
Relay counts are incremented each time a relay is actuated. You can  
programmatically retrieve the counts, stored on board the modules, and use  
them for predictive maintenance to reduce unexpected system downtime.  
Accessories  
SMA male-male cable (semirigid)  
0.15 cm..........................................................................…763443-01  
0.45 cm..............................................................................763444-01  
NI Switch Executive  
Signal Connectivity Options  
Development system ........................................................778546-01  
Deployment engine ..........................................................778548-00  
The PXI-2596, PXI-2597, PXI-2598, and PXI-2599 all use standard SMA  
connectors for signal connections. National Instruments offers two semirigid  
SMA cables (0.15 and 0.45 cm) that are acceptable for many RF/microwave  
signals. There are also many custom cable vendors on the market that can  
meet your exact cable length, performance, and connector requirements.  
Please visit ni.com/switches for a list of third-party cable vendors.  
BUY NOW!  
For complete product specifications, pricing, and accessory information,  
call (800) 813 3693 (U.S.) or go to ni.com/switches.  
26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches  
Dynamic Characteristics  
Expected relay life (mechanical)  
Specifications  
Input Characteristics  
Frequency range.................................. 0 to 26.5 GHz  
Characteristic Impedance ................... 50  
Maximum RF carry power (50 load)  
PXI-2596, PXI-2597, PXI-2599............. 150 W  
PXI-2598.......................................... 75 W  
Maximum voltage (cold-switching only)  
PXI-2596, PXI-2597, PXI-2599............. 90 Vrms  
PXI-2598.......................................... 65 Vrms  
Maximum carry current (per channel)  
PXI-2596.......................................... 107 cycles  
PXI-2597.......................................... 2 x 106 cycles  
PXI-2598.......................................... 2.5 x 106 cycles  
PXI-2599.......................................... 107 cycles  
Recommended cycle speed ................ 5 cycles/s  
Physical  
Relay manufacturer/PN  
PXI-2596.......................................... Radiall R591 series  
PXI-2597.......................................... Radiall R574 series  
PXI-2598.......................................... Radiall R577 series  
PXI-2599.......................................... Radiall R570 series  
Relay types.......................................... Electromechanical  
Contact material ................................. Beryllium copper, gold-plated  
I/O connectors..................................... SMA jacks  
Dimensions  
PXI-2596.......................................... 2-slot, 3U, PXI/cPCI module  
PXI-2597.......................................... 3-slot, 3U, PXI/cPCI module  
PXI-2598.......................................... 2-slot, 3U, PXI/cPCI module  
PXI-2599.......................................... 1-slot, 3U, PXI/cPCI module  
PXI-2596, PXI-2597, PXI-2599............. 1.73 Arms  
PXI-2598.......................................... 1.25 Arms  
Insertion Loss (dB)  
Frequency (GHz)  
Module  
PXI-2596  
PXI-2597  
PXI-2598  
PXI-2599  
0 to 3  
0.2  
0.2  
0.2  
0.2  
3 to 8  
0.3  
0.3  
0.3  
0.3  
8 to 12.4  
0.4  
0.4  
0.4  
0.4  
12.4 to 18  
0.5  
0.5  
0.5  
0.5  
18 to 26.5  
0.6  
0.7  
0.7  
0.7  
Voltage Standing Wave Ratio (VSWR)  
Environment  
Frequency (GHz)  
8 to 12.4  
Operating temperature ....................... 0 to 55 °C  
Storage temperature........................... -20 to 70 °C  
Relative humidity ................................ 5 to 85%, noncondensing  
Module  
PXI-2596  
PXI-2597  
PXI-2598  
PXI-2599  
0 to 3  
1.2  
1.2  
1.2  
1.2  
3 to 8  
1.3  
1.3  
1.3  
1.3  
12.4 to 18  
1.5  
1.5  
1.5  
1.5  
18 to 26.5  
1.6  
1.7  
1.7  
1.7  
1.4  
1.4  
1.4  
1.4  
Pollution degree..................................  
2
Approved altitude ............................... up to 2,000 m  
Indoor use only.  
Open Channel Isolation (dB)  
Shock and Vibration  
Frequency (GHz)  
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse  
(Tested in accordance with IEC-60068-2-27. Test profile developed in accordance  
Module  
PXI-2596  
PXI-2597  
PXI-2598  
PXI-2599  
0 to 3  
80  
80  
80  
80  
3 to 8  
70  
70  
70  
70  
8 to 12.4  
12.4 to 18  
18 to 26.5  
60  
60  
65  
60  
60  
60  
60  
60  
55  
55  
50  
55  
with MIL-PRF-28800F.)  
Random vibration  
Operating ........................................ 5 to 500 Hz, 0.3 grms  
Nonoperating.................................. 5 to 500 Hz, 2.4 grms  
(Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements  
RF Carry Power (W)  
of MIL-PRF-28800F, Class 3.)  
Frequency (GHz)  
Safety  
Module  
PXI-2596  
PXI-2597  
PXI-2598  
PXI-2599  
0 to 3  
150  
150  
75  
3 to 8  
95  
95  
50  
95  
8 to 12.4  
12.4 to 18  
18 to 26.5  
This product is designed to meet the requirements of the following  
standards of safety for electrical equipment for measurement, control,  
and laboratory use:  
75  
75  
35  
75  
65  
65  
30  
65  
25  
25  
25  
25  
150  
IEC 61010-1, EN 61010-1  
UL 61010-1  
CAN/CSA-C22.2 No. 61010-1  
PXI-2597 termination power, average (at 25 °C)  
Per termination............................... 1 W  
Total ................................................ 3 W  
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)  
2
26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches  
Electromagnetic Compatibility  
Emissions ............................................ EN 55011 Class A at 10 m FCC  
Part 15A above 1 GHz  
Immunity.............................................. EN 61326:1997 + A2:2001, Table 1  
EMC/EMI............................................. CE, C-Tick, and FCC Part 15  
(Class A) Compliant  
Note: For EMC compliance, operate these devices with shielded cabling.  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives, as amended for CE marking, as follows:  
Low-Voltage Directive (safety) ........... 73/23/EEC  
Electromagnetic Compatibility  
Directive (EMC) ................................... 89/336/EEC  
Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory  
compliance information. To obtain the DoC for this product, visit ni.com/certification, search  
by model number or product line, and click the appropriate link in the Certification column.  
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)  
3
NI Services and Support  
NI has the services and support to meet  
Local Sales and Technical Support  
your needs around the globe and through  
the application life cycle – from planning  
and development through deployment  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
In offices worldwide, our staff is local to the country, giving you access  
to engineers who speak your language. NI delivers industry-leading  
technical support through online knowledge bases, our applications  
engineers, and access to 14,000 measurement and automation  
professionals within NI Developer Exchange forums. Find immediate  
answers to your questions at ni.com/support.  
SERVICE  
NEEDS  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of technical  
support. Visit ni.com/ssp.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our  
products. NI training can shorten your learning curve, save development  
time, and reduce maintenance costs over the application life cycle. We  
schedule instructor-led courses in cities worldwide, or we can hold a  
course at your facility. We also offer a professional certification program  
Hardware Services  
NI Factory Installation Services  
NI Factory Installation Services (FIS) is the fastest and easiest way to  
use your PXI or PXI/SCXI combination systems right out of the box.  
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure  
using NI products. Visit ni.com/training.  
the system to your specifications. NI extends the standard warranty by  
one year on hardware components (controllers, chassis, modules)  
purchased with FIS. To use FIS, simply configure your system online with  
Professional Services  
Our Professional Services Team is comprised of NI applications engineers, ni.com/pxiadvisor.  
NI Consulting Services, and a worldwide National Instruments Alliance  
Calibration Services  
Partner program of more than 600 independent consultants and  
integrators. Services range from  
start-up assistance to turnkey  
NI recognizes the need to maintain properly calibrated devices for  
high-accuracy measurements. We provide manual calibration  
procedures, services to recalibrate your products, and automated  
calibration software specifically designed for use by metrology  
laboratories. Visit ni.com/calibration.  
system integration.  
Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you  
want to use our products for OEM applications. For information about  
special pricing and services for OEM customers, visit ni.com/oem.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair  
and advance replacement services are also available. We offer  
extended warranties to help you meet project life-cycle requirements.  
Visit ni.com/services.  
ni.com • (800) 813 3693  
*342572A-01*  
342572A-01  
2006-6497-101-D  
National Instruments • info@ni.com  
© 2006 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI,  
ni.com, NI-DAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.  
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.  

相关型号:

PXI-2598

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
NI

PXI-2599

26.5 GHz Multiplexers, SPDT Relays, and Transfer Switches
NI

PXI-3920

3U Intel Core2 Duo T7500 2.2GHz/ Pentium M 760 Single-Core Processor-based PXI Controllers
ETC

PXI-3950

3U Intel Core2 Duo T7500 2.2GHz/ Pentium M 760 Single-Core Processor-based PXI Controllers
ETC

PXI-3980

3U Intel Core i7-2715QE 2.1 GHz Quad-Core Processor-based PXI Controller
ETC

PXI-4022

6-Wire Guard and Current Amplifier
NI

PXI-4065

Low-Cost 6 1⁄2-Digit Multimeters
NI

PXI-4072

61⁄2-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
NI

PXI-4110

3 independent DC power supplies/16-bit voltage setpoint and current limit
NI

PXI-4132

100 V Precision Source Measure Unit (SMU)
NI

PXI-4204

DAQ for High-Voltage Measurements 16-Bit, 200 kS/s, 8 Analog Inputs
NI

PXI-5124

150 MHz, 200 MS/s, 12-Bit Digitizer
NI