NEW DESIGN!  
Wider Operating Range  
1500V Isolation, Easier To Modify  
DMS -EB-AC/DC  
100-264Vac Power Supply  
Accessory Board for  
DMS-30PC/LCD Panel Meters  
Order on-line at www.datel.com  
This low-cost accessory board provides an easy way of powering all DMS-  
30PC-X-RL (red low-power models only), as well as all DMS-30LCD and DMS-  
40LCD (non-backlit, +5V-powered models only) panel meters from 100-264Vac  
(50/60Hz). The on-board AC/DC converter provides an isolated +5Vdc to power the  
meter’s electronics, while providing 1500Vac isolation between the AC supply and  
the input signal being measured. Line power and input signals connect to two  
rugged, screw-style terminal blocks (TB1 & TB2) permanently mounted on the  
DMS-EB-AC/DC. This type of terminal block provides reliable mechanical connec-  
tions and eliminates the need for any extra wiring harness connectors.  
Features  
· Allows meters to operate from 100  
to 240Vac (50/60Hz)  
· Screw-type terminal block connections  
· Provides 1500V isolation between AC  
supply and input signal  
· Has prototyping features of the standard  
DMS-EB board  
The DMS-EB-AC/DC board includes provisions for installing several user-  
supplied components that are required when the meter must be scaled to display  
non-standard input ranges. The DMS-EB-AC/DC has provisions for such common  
applications as attenuation of high input voltages, gain (span) and offset (zero)  
adjustments, and direct decimal point placement. The DMS-EB-AC/DC is compat-  
ible with all four input versions of the DMS-30 Series meters (±200mV, ±2V, ±20V  
and ±200V). Solder gaps, conveniently placed on the board, are easily bridged or  
cut to configure the board to meet each application’s specific requirements.  
· On-board solder gaps for decimal  
point placement  
· Same size as DMS-30/40 meters  
2.02" (51.3mm)L x 0.82" (20.8mm)W  
· Low cost  
1
2
1
+
S
5
V
(
–
)
I
N
P
U
T
L
O
+
I
V
N
+
O
V
U
T
U
P
P
L
Y
S
G
1
0
S
G
1
4
D
C
/
D
C
R
2
C
O
N
V
E
R
T
E
R
1
1
2
3
(
+
)
I
N
P
U
T
H
I
–
I
V
N
–
O
V
U
T
R
1
1
0
G
N
A
N
A
L
O
C
O
M
M
O
R
3
R
4
5
R
V
S
G
9
S
G
7
1
0
.
5
k
2
k
E
T
U
R
N
+
S
S
S
G
G
G
3
2
1
9
4
5
6
+
1
.
2
3
V
S
G
6
S
G
1
1
D
D
P
3
R
E
F
.
O
U
T
S
G
8
S
G
1
3
R
5
8
R
E
F
.
O
U
T
/
D
P
4
D
P
2
5
0
k
S
G
4
P
1
7
R
E
F
.
I
N
S
G
1
2
Refer to Mechanical Layout drawing for components and  
solder gap location.  
Components are user-supplied and not part of the  
standard product.  
R4 and R5 are part of the resistor accessory kit RN-DMS  
(see ordering information)  
O
C
p
e
n
s
o
l
d
e
r
g
a
p
T
B
1
T
B
2
l
o
s
e
d
s
o
l
d
e
r
g
a
p
SG5 is not used  
1
2
1
2
H
I
L
O
A
C
A
C
(
+
)
(
–
)
L
O
H
I
Figure 1. DMS-EB-AC/DC Simplified Schematic Diagram  
DATEL, Inc., Mansfield, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email:sales@datel.com · Internet: www.datel.com  
1 0 0 - 2 6 4 V a c P O W E R S U P P L Y B O A R D F O R D M S - 3 0 M E T E R S  
DMS-EB-AC/DC  
ensure that modifications, if any, have been correctly made and that all  
cut solder-gaps are fully open. Align pin 1 of the meter with pin 1 of the  
DMS-EB-AC/DC, slide the board down flush to the meters housing and  
solder all 12 pins. Lastly, carefully cut the meters 12 pins as close as  
possible to the pc-board surface.  
Functional Specifications  
(TA = +25°C)  
AC Supply Voltage:  
100 to 264Vac @ 47-68Hz  
AC Supply Current @ 264Vac/60Hz  
Making absolutely sure that the AC supply is de-energized (OFF),  
connect the AC supply to TB2 terminals 1 (AC LO) and 2 (AC HI).  
Connect the input signal being measured to TB1 terminals 1 (+HI) and 2  
(-LO).  
60mA, maximum  
Isolation  
1500Vac, minimum  
Operating Temperature Range  
0 to +60°C  
2. Grounding/Isolation: Because DMS-30 and DMS-40 meters are housed  
in a plastic case, a connection to AC earth ground is not required. When  
wired per the instructions above, the DMS-EB-AC/DC board provides a  
minimum of 1500V isolation between its AC supply input (TB2) and its  
input signal (TB1). However, please keep in mind that in many applica-  
tions the LO side of the input signal may be connected to AC ground  
Storage Temperature range  
–25 to +75°C  
Humidity  
0 to 95%, non-condensing  
Dimensions  
2.02" (51.31mm)L x 0.82" (20.8mm)W x 0.60" (15.3mm)D  
(i.e., earth ground) elsewhere in the system. Any Issues pertaining to  
grounding and/or isolation of the DMS-EB-AC/DC power supply  
board must be referred to qualified technical personnel.  
TB1 and TB2 Wire Size and Strip Length  
Wire Size  
Strip Length 0.25" (6.35mm)  
Screw Torque 3.6 pound-inches (0.4Nm)  
Rated Voltage 310Vac  
16 to 22 AWG (solid or stranded)  
3. Input Resistor Dividers (See Figure 4): Use 1%, or better, metal film  
resistors for R1 and R2 in DMS-30 applications, and 0.5%, or better, in  
DMS-40LCD applications. Make sure the resistors power and voltage  
ratings are adequate for the given application. Using tight-tolerance  
resistors in input scaling circuits allows most calibration adjustments to  
be made with the meters internal rear-mounted potentiometers, through  
the access holes provided (seeTechnical Note 5 below).  
Ordering Information  
DMS-EB-AC/DC  
RN-DMS  
AC power supply board  
Resistor accessory kit for DMS-30 meters  
4. DMS-40LCD Meters: The RN-DMS resistor accessory kit, comprised of  
potentiometers R4 (Gain/Span) and R5 (Offset/Zero), cannot be used  
with DMS-40LCD Series meters. However, to change the input range on  
DMS-40LCD meters from the default low-range (i.e., with pin 2 of the  
meter open) to the high range, short pin 2 to pin 1 (+5V) on the top right  
side of DMS-EB-AC/DC board (refer to Figure 2 and the DMS-40LCD  
data sheet for more information).  
Introduction  
As shipped, the DMS-EB-AC/DC is configured for use with +5V-powered  
DMS-30PC or DMS-30LCD 3½ digit meters using the meters internal  
reference (SG13 is closed). This configuration is the most common and  
works well for most simple voltage measurements. Please read all of the  
following technical notes and perform any required modifications before  
soldering the DMS-EB-AC/DC onto the host meter.  
5. Calibration PotentiometerAdjustment Holes:Two overlapping holes  
on the DMS-EB-AC/DC provide access to the built-in ¾-turn calibration  
potentiometer on DMS-30 meters or the 3-turn potentiometer on DMS-  
40LCD meters. The adjustment range of both pots is very narrow. See the  
applicable product data sheet for more information on each meters  
calibration potentiometers.  
Many of the applications described below apply to both DMS-30 (3½ digit  
resolution) and DMS-40 (4½ digit resolution) meters. However, Application 5,  
installing the span (R4) and offset (R5) adjust potentiometers, can only be  
used with DMS-30PC/LCD meters. Also note that some of the other  
applications require the installation of R4 and R5. See Technical Note 4  
when using the DMS-EB-AC/DC with DMS-40LCD meters.  
6. Solder Gap Identification (See Figure 2): Each solder gaps respective  
number is printed directly on the pc-board surface in copper etch. Be sure  
to double check all solder gap modifications before applying ac power and  
the input signal to the DMS-EB-AC/DC.  
!IMPORTANT! AC power must be disconnected from TB2 terminals 1  
and 2 before making modifications or installing user-supplied  
components on the DMS-EB-AC/DC board! In many applications, the  
DMS-EB-AC/DC installation is subject to electrical-code requirements (for  
example, the NEC in the USA). Fusing, grounding, wire gauges, and leakage  
currents may be regulated items. Since the DMS-EB-AC/DC is a line-  
operated device, it presents a shock hazard and should be installed only by  
qualified personnel. Do not hesitate to contact DATELif you have any  
questions.  
7. AC Supply Transients: The DMS-EB-AC/DC can withstand transients  
typically found in instrumentation environments. Installations which  
contain ac-powered equipment capable of generating large voltage and/or  
current surges should use external energy-clamping devices. A 1500 Watt  
bi-directional transzorb with a minimum stand-off voltage rating that  
matches the highest line-voltage peaks will provide additional protection  
under severe fault conditions. If a transzorb or other energy limiting device  
is used, the ac supply feeding the DMS-EB-AC/DC should have its own  
fuse. Refer to the fusing section for more information.  
Technical Notes  
8. AC Supply Fusing: The DMS-EB-AC/DC board does not have an  
internal fusing device. If required, a 0.2A slow-acting fuse is recom-  
mended. Be sure the fuse is rated for the applied line voltage.  
1. Soldering and Wiring: DATELrecommends the use of no-clean”  
solders when installing components or making modifications to the DMS-  
EB-AC/DC. Before mating the DMS-EB-AC/DC to the host meter,  
2
1 0 0 - 2 6 4 V a c P O W E R S U P P L Y B O A R D F O R D M S - 3 0 M E T E R S  
DMS-EB-AC/DC  
S
G
1
0
1
2
1
S
G
1
4
S
S
G
G
7
8
S
G
6
T
T
B
2
B
1
S
S
S
G
G
G
3
2
1
(
(
(
D
D
D
P
P
P
3
2
1
)
)
)
S
G
4
D
P
4
S
G
1
1
S
G
1
3
R
3
S
G
9
S
G
1
2
1
2
1
2
H
I
(
+
)
A
C
L
O
A
C
H
I
L
O
(
–
)
Figure 2. DMS-EB-AC/DC Board  
Applications  
Potentiometer R5 applies a stable, positive dc-offset voltage to the  
meters IN LO terminal. This offset voltage has a range of 0 to +1.2Vdc,  
measured with respect to TB1 terminal 2 (LO). It can be used to null (or  
cancel) the effects of an input whose zero level is not exactly zero volts.  
For example, adjusting R5 allows the display to read 000” with an input  
whose lowest level is slightly above zero volts. Please note, R5 can not  
compensate for inputs whose zero level is negative (i.e., if TB1 HI is  
more negative than TB1 LO).  
1. Decimal Point Placement: DATEL ships the DMS-EB-AC/DC with all  
decimal point solder gaps (SG1, SG2, SG3 and SG4) open. To enable a  
specific decimal point, close its respective solder gap with solder. When  
reassigning decimal places for subsequent applications, remember to  
open any previously closed solder gaps.  
Close SG1 for 1.999 (DP1)  
Close SG2 for 19.99 (DP2)  
Close SG3 for 199.9 (DP3)  
Close SG4 for 1999.9 (DP4 on DMS-40LCD)  
3. Measuring Input Voltages Greater than 1.999Vdc (Use DMS-30-0 or  
DMS-30-1 Only): If possible, the resistors used for R1 and R2 should be  
±1% metal-film types with TCR’s less than or equal to 100ppm/°C. More  
information on selecting 1% resistors can be found in Application Note 14  
of the DATEL Panel Meter Catalog.  
2. Span (Gain) and Zero (Offset) Adjustments (See Figure 3): DATEL  
offers a resistor accessory kit, part number RN-DMS, consisting of 20-  
turn potentiometers R4 (2K Ohms) and R5 (50K Ohms) and leaded  
resistor R3 (10.5K Ohms). However, the leaded resistor supplied with the  
RN-DMS accessory kit is not needed with the DMS-EB-AC/DC since it  
contains a factory-installed 10.5K Ohm chip resistor. Once installed,  
these potentiometers permit the span and/or zero adjustments described  
in the following sections. R4 provides span adjust, while R5 applies a  
positive offset to the meters (–) IN LO input.  
CAUTION: Do not apply inputs greater than +/-250Vdc.  
1. Open SG10. For applications in which input voltages exceed ±100Vdc,  
also cut the 2 adjoining traces.  
2. Configure the DMS-EB-AC/DC for span adjust using the procedure  
previously outlined.  
3. Calculate values for R1 and R2 as follows:  
Atypical value for R1 is 1MW. The sum of R1 + R2 should be between  
50kW and 10MW.  
Using Potentiometer R4 for Span Adjustment (DMS-30PC and DMS-  
30LCD Meters Only)  
R2 = (FSI x R1) / ( |Vin| - FSI)  
Where:  
FSI = The attenuated voltage between the meters (–) IN LO and (+) IN  
HI pins (pins 12 and 11, respectively) needed to achieve the desired  
display readings  
1. For DMS-30-1, -2, and -3 models (+/-2V, +/-20V, +/-200V ranges):  
Configuring the DMS-EB-AC/DC for span adjustment is simply a matter  
of installing potentiometer R4, opening SG13, and then closing SG8,  
SG11, and SG12.  
2. For DMS-30-0 models (+/-200mV ranges): Span adjustment requires that  
you open SG8, SG11 (if closed) and SG13 and then close SG7, SG9  
and SG12. Then install R4.  
Vin = Input signal at TB1 terminals 1 and 2, disregarding polarity  
Example  
Using a DMS-30-1 meter (+/-2V range), Vin is 0-5Vdc and the display  
reading must be 000” to 1500”  
Adjust span as desired. DMS-30-1, -2, and -3 span adjustment range is  
typically +10% and –5%. The DMS-30-0 has a much wider span adjust,  
however, it should be limited to ±10% for optimum accuracy and stability.  
1. Assume R1 = 1.0MW.  
Using Potentiometer R5 to Apply a Positive Offset to Pin 12 (-) IN LO  
1. Open SG14 and close SG6.  
2. R2 = (FSI x R1) / ( |Vin| - FSI)  
R2 = (1.500 x 1,000,000) / (5.0 - 1.500)  
R2 = 428,571W or 432kW  
2. Install 50K potentiometer R5.  
3. Calibrate the meter using a known voltage source. Adjust R4 to  
compensate for tolerances in R1 and R2.  
3
DMS-EB-AC/DC  
1 0 0 - 2 6 4 V a c P O W E R S U P P L Y B O A R D F O R D M S - 3 0 M E T E R S  
Applications  
4. DC Current Measurements (Use +/-200mV Range DMS-30-0 Meters):  
3. Apply the input signal (current) to TB1 (+) HI and (–) LO.  
4. Adjust R4 for desired full scale readings.  
5. Enable the appropriate decimal point using SG1, SG2, or SG3.  
Example  
When using R2 location for a dc current-shunt, please note that the pc-  
board copper traces which short out R1 can only carry currents up to  
0.2A (200mA). However, dc currents up to 2A can be accommodated if a  
20AWG jumper wire is soldered in location R1. Be sure R2 has a  
sufficient power rating to safely carry the full load current. Refer to DMS  
Application Note 6 for more information on dc ammeters.  
Using a DMS-30-0 meter, a 0.100 Ampere input must read 100.0” mA on  
the display.  
1. Install R2: R2 = FSR / (IMAX . x 10000) where FSR is the desired meter  
reading (0 up to 1999, disregarding any decimal points), and IMAX is  
current in Amperes.  
R2 = 1000 / (0.1 x 10000)  
R2 = 1 Ohm  
Enable DP3 via SG3 for a display reading of 100.0.  
2. Configure the DMS-EB for span adjust using the procedure previously  
outlined for the DMS-30-0 (+/-200mV range).  
R
1
1
2
S
G
1
0
1
2
R
2
R
5
S
G
1
4
S
G
1
4
S
S
G
G
7
8
S
S
G
G
7
8
S
G
6
T
S
G
6
T
B
1
B
1
S
G
D
4
P
4
S
G
D
4
P
4
S
G
1
1
S
G
1
1
R
4
S
G
1
3
S
G
1
3
R
3
R
3
S
G
9
S
G
9
S
G
1
2
S
G
1
2
1
2
1
2
H
I
(
+
)
H
I
(
+
)
O
L
O
(
–
)
L
(
–
)
Figure 3. R4 and R5 Installation  
Figure 4. R1 and R2 Installation  
®
®
ISO 9001  
www.datel.com  
R E GIS TE R E D  
DS-0341B 09/00  
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444  
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01  
DATEL GmbH München, Germany Tel: 89-544334-0  
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA02048-1151  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
Internet: www.datel.com Email: sales@datel.com  
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025  
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions  
contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL,  
Inc. trademark.  

相关型号:

DMS-EB-C

Multi-Purpose Application Board for DMS-30 & DMS-40 Series Meters
MURATA

DMS-EB-RMS

AC-to-RMS Converter Application Board for DMS-30PC/LCD Meters
ETC

DMS-EB2

Multi-Purpose Application Board for DMS-20PC/LCD Meters
MURATA

DMS-LM2

Self-Powered LED Display High-Voltage, 50/60/400Hz AC Line Monitor
MURATA

DMS-LM3

Self-Powered LED Display 480V AC Line Monitor
MURATA

DMS-PS-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS1-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS1-CM-C

0-5V and 0-10V Input 3½ Digit, LED Display Process Control Monitors
MURATA

DMS-PS10-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS11-CM

Converter
ETC

DMS-PS12-CM

Converter
ETC

DMS-PS2-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA