DMS-EB2 [MURATA]

Multi-Purpose Application Board for DMS-20PC/LCD Meters; 多功能应用板的DMS- 20PC / LCD仪表
DMS-EB2
型号: DMS-EB2
厂家: muRata    muRata
描述:

Multi-Purpose Application Board for DMS-20PC/LCD Meters
多功能应用板的DMS- 20PC / LCD仪表

仪表 CD PC
文件: 总4页 (文件大小:287K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DMS-EB2  
Multi-Purpose Application Board  
for DMS-20PC/LCD Meters  
The DMS-EB2 Application Board was designed for quick and easy application/evalu-  
ation of DATEL's subminiature DMS-20PC/LCD Series, 3½ Digit, LED/LCD Display, Digital  
Panel Voltmeters. The DMS-EB2's versatility, low cost and direct DMS-20PC/LCD plug-in  
compatibility makes interfacing a breeze. The DMS-EB2 covers many common panel-  
meter applications while providing easy signal and power I/O terminations (via a standard  
MOLEX connector) and plug-in versatility when changing from one application to another.  
The DMS-EB2 has provisions for such common applications as input dividers for high  
input voltages, gain (span) adjustment, 9/12Vdc battery operation, and decimal point place-  
ment. The board permits direct signal I/O wiring via the interface connector or soldering  
directly to the board. The DMS-EB2 is fully compatible with all four versions of the DMS-  
20PC/LCD ( 200mV, 2V, 20V, 200V) making it interchangeable from meter to meter  
and application to application. Solder gaps  
FEATURES  
N
Gain (span) adjustment  
N
Input divider network for attenuating voltages  
up to 250Vdc  
N
Operate meter and board from +5V supply or  
9/12V battery  
N
On-board solder gaps for decimal point placement  
N
On-board I/O connector for easy power and signal input  
12  
1
R1  
SG10  
are conveniently placed on the board and  
may be quickly bridged or cut as required.  
This low-cost addition to DATEL's  
R2  
SG14 SG6 SG5 SG4  
expanding line of subminiature meters dem-  
onstrates our continuing commitment to offer  
the most versatile, easy-to-use panel-meter  
products.  
R5  
J1  
C1  
2
+C2  
U1  
SG15  
1
3
4
5
6
J2  
SG1  
For full details go to  
www.murata-ps.com/rohs  
Figure 1. DMS-EB2 Schematic Diagram  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-EB2.E01 Page 1 of 4  
DMS-EB2  
Multi-Purpose Application Board  
for DMS-20PC/LCD Meters  
A 10μF/35V tantalum capacitor (C2 on schematic) should be installed  
with the polarized end next to the + symbol on the DMS-EB2. This is  
especially important if the power source is located far from U1.  
Functional Specifications (TA = 25ºC)  
Input Supply Range  
See applicable meter's data sheet  
5. Soldering: DATEL recommends the use of "no-clean" solders when  
Input Supply Range U1 (LM7805CT) Installed:  
making modifications to the DMS-EB2.  
DMS-20PC-X-XS  
DMS-20PC-X-XL  
DMS-20LCD-X-5  
DMS-20LCD-X-5B  
+7.5 to +12.6V  
+7.5 to +32.0V  
+7.5 to +32.0V  
+7.5 to +12.6V  
APPLICATIONS  
Operating and Storage Temperature  
See applicable meter's data sheet  
As shipped, the DMS-EB2 is configured for single-ended operation.  
This configuration is preferred for simple voltage measurements and will  
generally cover most standard applications. Figure 1 indicates which  
solder gaps are shipped closed from the factory.  
Humidity  
0 to 95%, non-condensing  
Dimensions  
1.25" (31.8mm)L x 0.75" (19.1mm)H  
Simply solder the board onto the meter (pin 1 to pin 1), connect  
the power supply to J1, pin 5 (+V) and the power return to J1, pin 6  
(GROUND).  
J1 Connector & Wire Information  
Terminal Type  
Crimp Tool  
Wire Size  
DATEL P/N 39-2099090  
DATEL P/N 39-2099000  
22 to 26 AWG  
Insulation Diameter  
Stripping Length  
0.062" (1.57mm) max.  
0.100" to 0.125"  
(2.54 to 3.17mm)  
Pin Function  
1
2
3
4
5
6
(+) INPUT HI  
J1  
(–) INPUT LO  
1
2
3
4
5
6
TEST/HOLD IN  
Ordering Information  
TEST/HOLD OUT  
DMS-EB2  
DMS-BZL3  
DMS-BZL4  
Application board with mating connector and terminals  
DMS-20 bezel assembly  
DMS-20 bezel assembly with sealing gasket  
+V (Positive power connection)  
–V (Ground, negative power return)  
Figure 2. J1 Connector Pinout  
39-0304000 LM7805CT (U1), +5V-output, three-terminal regulator  
39-2359625 6-position pc-board socket  
1.Decimal Point Placement: DATEL ships the DMS-EB2 with all decimal  
point solder gaps (SG1, SG2 and SG3) open. To enable a specific  
decimal point, close its respective solder gap with solder. When  
re-assigning decimal places for subsequent applications, remember to  
unsolder previously closed solder gaps.  
TECHNICAL NOTES  
1.LCD Backlighting: To backlight a DMS-20LCD meter, connect J1, pin 3  
(TEST/HOLD IN) to J1, pin 6 (GND). This allows for external control,  
via a switch, of the backlight feature. The switch should be rated for low  
voltage operation at 35mA.  
Close SG1 for 1.999 (DP1)  
Close SG2 for 19.99 (DP2)  
Close SG3 for 199.9 (DP3)  
2. Display Test (Not Available on LCD Models): Tie pin 4 (TEST/HOLD  
OUT) to pin 3 (TEST/HOLD IN) to test the display of the DMS-20PC.  
Do not leave the meter in the test mode for more than 10 seconds. On  
LED meters with the HOLD option, tying pins 3 and 4 together freezes  
the display reading.  
2.9V LCD Meters: DMS-20LCD-X-9 meters cannot be used in a single-  
ended configuration, i.e., with (–) IN LO tied to GND. On these models,  
both (–) IN LO and (+) IN HI have to be a minimum of 1.5V above and  
1.5V below J1 pins 6 and 5, respectively. To operate from a 9V or 12V  
battery with (–) IN LO tied to GND, use a 5V-powered meter (DMS-  
20LCD-X-5), install U1 (LM7805CT) and open SG4.  
3. Battery Operation: Open SG4 and install U1 (LM7805CT) with its metal  
tab facing to the left as shown in Figure 3. Allowable input power ranges  
(J1, pins 5 and 6) are as follows:  
3. Input Resistor Dividers: Always use 1%, or better, metal-film resistors  
for R1 and R2, and also make sure their power and voltage ratings are  
adequate for the given application.  
DMS-20PC-X-XS +7.5 to +12.6Vdc  
DMS-20PC-X-XL  
+7.5 to +32Vdc  
4. Using U1 (LM7805CT): The input power range specified in the Battery  
Operation section is rated conservatively assuming a 100mA LED meter  
or a 35mA backlit LCD meter. If a non-backlit LCD model or the low-  
power LED model is used, the input voltage range can be extended up to  
32Vdc.  
C2 (10μF/35V) can be added to reduce noise. Observe correct polarity.  
Refer to Technical Note 4 for more information.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-EB2.E01 Page 2 of 4  
DMS-EB2  
Multi-Purpose Application Board  
for DMS-20PC/LCD Meters  
R1  
12  
SG10  
1
R3  
U1  
TO-3-style tab  
points to left  
To measure input voltages  
greater than 100ꢀVdc  
open SG10 anV also dut  
these two etdh paths.  
SG1  
Figure 4. Installing R1  
4. Calibrate the meter using a known voltage source. Adjust the internal  
gain potentiometer to compensate for variations in R1 and R2.  
Figure 3. Installing U1  
Example  
IN is 199.9Vdc, and the display reading must be "199.9".  
4. Calibration Adjustment: The DMS-EB2 has provisions for adjusting the  
calibration of the DMS-20 meter. Calibration adjustment is useful when  
an input divider (using R1 and R2) is necessary to scale the input voltage.  
The calibration potentiometer allows "tweaking" of the display reading.  
V
1. Assume R1 = 1.0M7ꢀ  
2. R2 = (FSI x R1) / ( |VIN| - FSI)  
R2 = (1.999 x 1,000,000) / (199.9 - 1.999)  
R2 = 10101.01Ω or 10kΩ  
Using the calibration potentiometer  
Adjust the calibration pot on the back of the meter as desired. The  
adjustment range is only 3/4 of a turn. Do not force the pot past its end  
stops.  
7. Current Measurements (Use 200mV Model, DMS-20PC/LCD-0): The  
following instructions are for measuring current derived from the DMS-  
20PC/LCD's power source. When measuring current that is floating with  
respect to J1, pin 6 (GROUND), leave SG5 closed.  
5. Differential Input Signals (Signal Referenced to Power Source): Open  
SG5. Apply the input signal to pin 1, (+) IN HI, and pin 2, (–) IN LO, of J1.  
NOTE: Common mode voltage must not exceed 2Vdc.  
CAUTION: Do not exceed 1 Ampere input current.  
6. Measuring Input Voltages Greater than 1.999Vdc (Use DMS-20PC/  
1. Install R2 (R2 = FSR / (IMAX x 10000)) where FSR is the  
desired reading (0-1999) and IMAX is between 0 -1 Ampere.  
LCD-1 Only):  
CAUTION: Do not exceed 250Vdc input signal.  
2. Open SG5.  
1. Open SG10. For applications in which input voltages exceed 100Vdc,  
also cut the 2 adjoining traces.  
3. Apply input signal (current) to (+)IN HI and (–) IN LO.  
4. Adjust internal gain pot for desired full scale readings.  
5. Enable decimal points using either SG1, SG2 or SG3.  
Example  
2. Calculate values for R1 and R2 as follows:  
R2 = (FSI x R1) / ( |VIN| - FSI)  
Where:  
A 1.0 Ampere input must read "1.000" on the display.  
FSI = The attenuated voltage, between the meter's (–) IN LO and (+) IN  
HI pins, needed to achieve the desired display readings  
R2 = 1000 / (1 x 10000)  
R2 = 0.1 Ohm  
V
IN = Input voltage at J1 (beween pins 1 and 2)  
Enable DP1 via SG1 for reading of 1.000  
A typical value for R1 is 1M7. The sum of R1 + R2 should be  
between 50k7 and 10M7.  
8. Displaying DMS-20PC/LCD's Power Source  
(Use DMS-20PC/LCD-2, 5V-Powered Models Only):  
3. Enable DP3 by soldering SG3.  
1. If the power source is higher than 5Vdc, be sure to install U1 and cut  
SG4. See Battery Operation section and Technical Note 4.  
2. Solder a short piece of jumper wire across the two holes labeled J2.  
3. Close SG2 to enable DP2.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-EB2.E01 Page 3 of 4  
DMS-EB2  
Multi-Purpose Application Board  
for DMS-20PC/LCD Meters  
USA:  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
Canada:  
UK:  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Murata Power Solutions, Inc.  
France:  
Germany:  
Japan:  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
11/10/08  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-EB2.E01 Page 4 of 4  

相关型号:

DMS-LM2

Self-Powered LED Display High-Voltage, 50/60/400Hz AC Line Monitor
MURATA

DMS-LM3

Self-Powered LED Display 480V AC Line Monitor
MURATA

DMS-PS-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS1-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS1-CM-C

0-5V and 0-10V Input 3½ Digit, LED Display Process Control Monitors
MURATA

DMS-PS10-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS11-CM

Converter
ETC

DMS-PS12-CM

Converter
ETC

DMS-PS2-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS3-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS4-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS4-CM-C

0-5V and 0-10V Input 3½ Digit, LED Display Process Control Monitors
MURATA