DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Universal Input  
85-264Vac or 110-340Vdc  
FEATURES  
N
Up to 80% efficient single, dual, and triple-  
output model  
C
N
Individual, fully-isolated outputs:  
3000Vac on main  
US E156931  
®
4000V double-isolation on auxiliaries  
Murata Power Solution’s DMS-PS-CM Series  
night light! These low cost, high-efficiency  
power supplies can significantly reduce  
long-term electricity costs in low (<5Watts)  
to medium (<16Watts) power applications.  
All DMS-PSX-CM power supplies fea-  
ture universal inputs of 85-264Vac 50/60Hz,  
built-in line fuses, and on-board ‘Power On’  
LED indicators. At full rated load, hold-up  
time is typically 20ms at 120Vac, and 80ms  
at 230Vac. All outputs provide indefinite  
short-circuit protection and, for added reli-  
ability, the main high-current output also  
includes overvoltage protection. A rugged,  
vibration-proof, chassis mount package  
incorporates large, shock-resistant terminal  
blocks for all I/O connections.  
of high-efficiency, chassis mount AC/DC  
power supplies feature low noise (40mV on  
main, 8mV on auxiliaries), fully-isolated +24,  
+12V, and +5V outputs, making them perfect  
for powering today’s complex instrumenta-  
tion. A high-current main output is isolated  
from the AC line by 3000Vac. In dual- and  
triple-output models, the low-current auxiliary  
outputs are isolated from the main output by  
1000Vdc, and from each other by 2000Vdc,  
effectively providing double isolation from the  
AC line! This unprecedented isolation elimi-  
nates ground loop problems in complex,  
multiple-instrument applications.  
Full-load efficiencies of up to 80% and  
output-power ratings of 5, 10 or 16 Watts,  
combine to ensure minimal ac power con-  
sumption. For intermittent use or low-power  
applications, the 5-Watt model’s no-load  
quiescent consumption with a nominal  
120Vac input is a mere 0.6 Watts---that’s  
nearly seven times less than a standard 4W  
N
N
Available with +5V, +12V, and +24V outputs  
Low noise: 40mVp-pk on main, 8mVp-pk on  
auxiliaries; Ideal for sensitive instrumentation  
N
N
Universal input: 85-264Vac @ 47-63Hz or  
110-340Vdc  
Choice of 5, 10, or 16W models for minimal  
system power-consumption  
N
N
Standby power consumption as low as 0.6W  
Short-circuit protection on all outputs;  
OVP on main output  
N
N
N
Built-in ac mains fuse & ‘Power On’ indicator  
5W models operate up to 5 LED-display DPM’s  
Multiple outputs, low noise, low cost,  
Vibration-resistant, chassis-mount  
modular packages  
high efficiency, double isolation, and rugged  
construction combine to make DMS-PSX-  
CM Series AC/DC power supplies the  
ideal choice for powering today’s sensitive  
instrumentation, and any electronic device  
that requires a reliable dc voltage!  
N
N
EMC compliant; UL/CSA recognized  
Low cost!  
LDO  
Regulator  
DC/DC  
Converter  
**  
TB3  
TB2  
+
+
+
IN  
OUT  
GND  
+
+
+
+
V3 (Auxilliary)  
LDO  
Regulator  
DC/DC **  
Converter  
+
F1  
1A/250V  
+
AC/DC Converter  
+
IN  
OUT  
GND  
TB4  
(Auxilliary)  
V2  
AC(L)  
AC(N)  
FG  
85-264V  
50/60Hz  
or  
TB1  
*
+
or  
Drive  
Circuitry  
+
+
110-340Vdc  
(Main)  
V1  
110-340Vdc  
*Not used on single-output models  
**Used only on dual and triple-output models  
For full details go to  
www.murata-ps.com/rohs  
Figure 1. Simplified Schematic  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 1 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Performance/Functional Specifications  
Typical at TA = +25°C and VIN = 85-264V @47-63Hz  
AC Input  
Input Voltage Range, All models ~  
DC Outputs (continued)  
Efficiency (Typ.@ 120Vac, full load):  
85-264V @47-63Hz  
Single Output Models  
Dual Output Models  
Triple Output Models  
75ꢀ  
73ꢀ  
71ꢀ  
Input Current (115V/230V, typ.):  
5-Watt Models  
10-Watt Models  
0.15A/0.07A  
0.3A/0.13A  
0.33A/0.16A  
16-Watt Models  
DC-Output Terminal Blocks (TB1, TB2, TB3):  
Wire Size &Type  
16-20AWG (1.5 to 0.5mm2),  
solid or stranded  
Inrush Current (All models, typical peak):  
@115Vac  
@230Vac  
14.1A  
32.5A  
Insulation Strip Length  
Screw Tightening Torque  
0.25 inches (6.4mm)  
3.6 pound-inches (0.4Nm)  
Isolation (Min.):  
Short Circuit Protection (All outputs)  
Overvoltage Protection V1 (max.)  
Foldback, self-recovering  
134ꢀ x Vout  
Output V1 to AC Input  
3000Vac  
Outputs V2 & V3 to AC Input  
AC Input to Frame Ground  
Output V1 to Frame Ground  
Outputs V2 & V3 to Frame Ground  
Outputs V2 & V3 to Output V1  
Output V2 to Output V3  
3000Vac + 1000Vdc  
1500Vac  
Environmental  
Operating Temperature  
–25 to +70°C @ 50ꢀ rated power  
500Vac  
0 to +50°C @ full rated power;  
(see Figure 3)  
500Vac + 1000Vdc  
1000Vdc  
2000Vdc  
Storage Temperature  
Cooling  
–40 to +85°C  
Frame Ground Leakage Current (Max.):  
@115Vac  
@230Vac  
Free air convection with derating  
(see Figure 3 and Technical  
0.5mA  
3.5mA  
Notes)  
Switching Frequency (Typical):  
V1 (5W and 10W models)  
V1 (16W models)  
Humidity (Non-condensing)  
0 to 85ꢀ  
75kHz  
83kHz  
100kHz  
Physical  
Dimensions  
V2 & V3 (All models)  
See Mechanical Specifications  
Line Fuse (Built-in)  
IEC60127-2, sheet 3 specification  
(slow-blow)  
1A/250Vac, 5 x 20mm, meeting  
for time lag fuses  
Weight:  
5 Watt Models  
10 Watt Models  
16 Watt Models  
5.8 ounces (165 grams)  
6.9 ounces (195 grams)  
7.9 ounces (223 grams)  
AC Mains Terminal Block (TB4):  
Wire Size & Type  
14-20AWG (2.5 to 0.5mm2),  
solid or stranded  
Case Materials:  
Outer Case  
ABS, UL94 5VA  
Phenolic, UL94 V-0  
Plastic, UL94 V-1  
Insulation Strip Length  
Screw Tightening Torque  
Rated Voltage  
0.25 inches (6.4mm)  
DC/DC Modules  
AC/DC Modules  
4.4 pound-inches (0.5Nm)  
630V (VDE 0110-V. Group 2);  
250V (VDE 0110-V. Group 3)  
~ All models will also operate from a regulated and filtered 110 to 340Vdc input.  
EMI (All models)  
Class B  
Meets CISPR Pub. 22 & FCC  
Pending  
 Unless otherwise specified, load regulation is measured with the output under  
test undergoing a load change of 100% to 50% at nominal line input and,  
when applicable, with all other outputs operating at 50% of rated load.  
Safety Approvals  
€ Transient response is defined as the output returning to within its specified  
tolerance in 10ms or less, following a 90% load change.  
DC Outputs  
Line Regulation (All outputs)  
0.1ꢀ (max)  
Load Regulation:   
V1 (All models)  
V2 & V3 (All models)  
2ꢀ  
0.2ꢀ (max)  
Output Accuracy (Max.):  
V1 (All models)  
V2 & V3 (All models)  
2.0ꢀ  
2.5ꢀ  
Hold-Up Time (47-63Hz):  
@115Vac  
@230Vac  
20mSec. typ.  
80mSec. typ.  
Noise & Ripple  
(All models, 20MHz bandwidth):  
See Noise & Ripple graphs  
40mVp-pk (typ.)  
V1  
V2 & V3  
8mVp-pk (typ.)  
Transient Response €  
See Transient Response graphs  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 2 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Ordering Information and Selection Guide  
MPS Part No.  
DMS-PS1-CM  
DMS-PS2-CM  
DMS-PS3-CM  
DMS-PS4-CM  
DMS-PS5-CM  
DMS-PS6-CM  
DMS-PS7-CM  
DMS-PS8-CM  
DMS-PS9-CM  
DMS-PS10-CM  
~ Efficiency typical @120V/60Hz  
Rated Power  
5 Watts  
Efficiency ~  
75ꢀ  
V1 Output  
5Vdc/1A  
V2 Output  
V3 Output  
5 Watts  
73ꢀ  
5Vdc/0.65A  
5Vdc/0.35A  
24Vdc/0.45A  
24Vdc/0.35A  
24Vdc/0.30A  
24Vdc/0.70A  
24Vdc/0.60A  
24Vdc/0.55A  
12Vdc/1.35A  
4.85Vdc/0.2A  
4.85Vdc/0.2A  
5 Watts  
71ꢀ  
4.85Vdc/0.2A  
10 Watts  
10 Watts  
10 Watts  
16 Watts  
16 Watts  
16 Watts  
16 Watts  
80ꢀ  
75ꢀ  
4.85Vdc/0.2A  
4.85Vdc/0.2A  
73ꢀ  
4.85Vdc/0.2A  
82ꢀ  
76ꢀ  
4.85Vdc/0.2A  
4.85Vdc/0.2A  
4.85Vdc/0.2A  
74ꢀ  
82ꢀ  
3. Fuse Replacement: If any dc-output drops to zero volts, and no fault  
conditions exist within the external load circuitry or the ac mains, F1 may  
have failed. F1 is located on the circuit (etch) side of the pc-board. Fuse  
replacement is performed by first de-energizing and then disconnecting  
the ac mains from TB4. Next, disconnect all load wiring from TB1, TB2,  
and TB3. Lastly, remove the four screws that secure the pc-board to the  
plastic case. After making sure that the new fuse is securely attached to its  
mounting clips, re-assemble the unit using all four screws. Reconnect all  
input and output wiring and re-apply ac power.  
TECHNICAL NOTES  
IMPORTANT! To ensure safe and reliable operation, DMS-PS-CM  
power supplies must be installed and serviced by qualified  
personnel. Contact Murata Power Solutions if there is any doubt  
regarding their installation and/or operation. Please read all of the  
following technical and application notes BEFORE installing or  
making connections to DMS-PS-CM power supplies.  
Warnings (Marking)  
If the unit still does not operate properly, and the ac supply at TB4 is  
measured to be within its specified operating range, the power supply  
is defective and must be replaced. Except for F1, DMS-PS-CM supplies  
contain no other user-serviceable components.  
Caution, unit may become hot in normal operation, thereby creat-  
ing a potential burn hazard. Disconnect ac mains and then allow  
unit to cool before servicing.  
Reference document: IEC 417, No. 5041.  
4. Wire Gauges and Fusing: All wiring connected to the DMS-PS-CM’s  
terminal blocks must meet the requirements specified in the Functional  
Specifications section. All ac supply and load wiring must be rated for the  
voltages and currents they will conduct and must comply with any code  
or application-mandated requirements pertaining to the user’s specific  
installation. Applications subject to vibration should include adequate strain  
reliefs on both input and output wiring. Install the strain reliefs within 2-3  
inches (5-7.5cm) of the terminal blocks.  
Dangerous, potentially lethal voltages are present during normal  
operation. Disconnect ac mains before servicing.  
Reference document: IEC 417, No. 5036.  
Caution, refer to accompanying documents for more informa-  
tion. Reference document: ISO 3864, No. B.3.1.  
It is recommended that all wiring be rated for 600V and 105°C operation  
(UL1015 type, for example). Also, wire insulation must be stripped to within  
10ꢀ of the dimensions shown in Figure 2. All wires must be inserted  
into their respective terminal blocks such that the screw terminal does not  
pinch their insulation. No more than two wires should be connected to  
any single terminal on TB1 through TB4. If two wires are attached to a  
single terminal, be sure to use only two 20AWG (0.5mm2) wires on TB1,  
TB2, and TB3, and only two 18 or 20AWG (0.75 or 0.5mm2) wires on TB4.  
1. Shock Hazard: DMS-PS-CM Series power supplies feature touch-proof  
terminals blocks and fully-isolated plastic construction, thereby greatly reduc-  
ing the risk of electrical shock. However, these are mains-powered devices  
whose operation is derived from hazardous and potentially lethal voltages.  
All service and installation must be performed by qualified personnel, with  
the ac supply voltage de-energized. Before making connections to any of  
the unit’s terminal blocks, use a digital voltmeter to verify that the ac supply is  
de-energized (off).  
2. AC Supply Fuse (F1): All DMS-PS-CM Series power supplies are equipped  
with a built-in 1A/250V time-lag fuse. Replacement fuses must be of the  
same type and rating; please refer to the Functional Specifications section  
of this datasheet for more information. F1 is conservatively rated in order  
to reduce nuisance tripping which might occur during power-up or output  
overload conditions. However, F1 is primarily intended to provide protection in  
the event of catastrophic failure in the DMS-PS-CM’s ac/dc converter.  
0.25"  
(6.4mm)  
Figure 2. Insulation Strip Length  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 3 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
The ac-mains circuit supplying power to DMS-PS-CM supplies must be fused  
according to the current rating of the wire gauge used, in accordance with  
applicable regulatory codes. The built-in 1ampere line fuse (F1) only protects  
the module itself from destructive over currents.  
adversely affect the operation and stability of auxiliary outputs V2 and  
V3. On these models, V1 must be adjusted to within 2 % of its nominal  
value (+5.0V, +12.0V, or +24.0V, depending on model).  
9. Temperature Derating (See Figure 3): All DMS-PS-CM supplies are speci-  
fied to operate at their full rated power over the temp range of 0°C to +50°C  
in still air (convection cooling) without any thermal derating. For operation  
over +50°C in still air, derate the output power linearly by 2.5ꢀ per °C down  
to 50ꢀ rated power at +70°C. To operate the units at full rated power between  
+50°C and +70°C, a minimum forced-airflow of 100 LFM is required. For  
operation below 0°C, derate the output power linearly by 2.0ꢀ per °C down  
to 50ꢀ rated power at –25°C.  
5. AC Mains Connections (TB4): To ensure EMI-compliant operation, all three  
ac-supply inputs must be properly connected to TB4. Never operate any DMS-  
PS-CM power supply without a ground connection to TB4’s ‘FG’ terminal.  
On 120Vac 50/60Hz mains, connect the black or "hot" lead to ‘AC(L)’, the  
white or “neutral” lead to ‘AC(N)’, and the supply ground (earth) to ‘FG’ (Frame  
Ground). On 220V 50/60Hz ac mains with line and neutral conductor-designa-  
tions, connect the line to AC(L), the neutral to AC(N), and the ground to ‘FG’.  
Unless forced air with the velocity noted above is employed, DMS-PS-CM  
supplies should never be mounted upside down (terminal blocks facing  
down). Also, always provide sufficient clearances in order to ensure adequate  
airflow around the supply.  
6. Connector Torque Ratings: It is extremely important to tighten all input and  
output terminal blocks securely. TB4’s screw terminals must be torqued to  
4.4 pound-inches (0.5Nm). TB1, TB2, and TB3 must be torqued to 3.6 pound-  
inches (0.4Nm). Proper tightening will minimize losses and ensure safe,  
reliable operation.  
10.V1 Peak Capabilities: DMS-PS-CM power supplies have a maximum  
continuous output-current rating that’s specified in the Ordering and Selection  
Guide. In addition, each model’s V1 output can intermittently supply 120ꢀ of  
its continuous rated current for short periods of time if the duty cycle is less  
than 10ꢀ. Peak current ratings do not apply to the auxiliary outputs V2 or V3.  
7. ‘Power On’ LED: The Power On LED indicates that the unit has ac-power  
applied and its V1 dc-output is operational. However, the power-on LED’s  
illumination does not imply nor guarantee that the unit’s dc-outputs are within  
their specified accuracy.  
11. Isolated Outputs: Unlike the majority of competitive ac/dc power supplies,  
all dual- and triple-output DMS-PS-CM power supplies feature fully-isolated  
outputs. This is an important feature when, for reasons of high common mode  
voltages, an instrument’s input circuit must be isolated from the system ground.  
All V1 outputs are isolated from the ac mains by a minimum of 3000Vac, while  
auxiliary outputs V2 and V3 are isolated from one another by 2000Vdc, and  
fromV1 by 1000Vdc. The low noise, double-isolated auxiliaries are ideal for  
powering sensitive instrumentation that requires low ac leakage-currents.  
8. Output Adjustment: The main output, V1, on all 5, 10, and 16W models is  
adjustable by approximately –10ꢀ to +15ꢀ. V1’s adjustment potentiometer  
is accessed via a small hole located next to the Power-On LED. While not  
recommended, field adjustment of single-output models can be performed  
within the tolerance window noted above. However, keep in mind that the  
unit’s maximum output power capability must not be exceeded. For example,  
increasing V1’s output voltage by 10ꢀ produces a corresponding 10ꢀ reduc-  
tion in V1’s maximum output current.  
All ac/dc and dc/dc power components utilized in the construction of DMS-  
PS-CM power supplies are 100ꢀ hi-pot tested during their manufacturing pro-  
cesses. In addition, after final assembly by MPS, all models are subjected to an  
additional hi-pot testing consisting of 1000Vac sequentially applied between the  
ac mains input and each output, and between each output and all other outputs.  
On dual-and triple-output units, V1 is factory calibrated with all outputs  
simultaneously loaded to 100% of their rated current. On all dual- and  
triple output models, adjusting V1 under any condition other than  
those just noted (i.e., all outputs loaded to their full rated current) will  
2.0% / ºC  
1 0 0  
2.5% / ºC  
7 5  
5 0  
2 5  
0
70ºC  
–25 –10  
0
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
Figure 3. Temperature Derating  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 4 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
3. Model Selection & Energy Conservation: In order to achieve the lowest  
possible energy consumption, be sure to determine your application’s total  
current requirements. This is especially true when using DMS-PS-CM  
supplies to power DATEL’s energy-efficient LED and/or LCD display digital  
panel meters (DPMs) and process monitors. In general, choose a power  
supply that will accommodate your maximum current consumption plus a  
20ꢀ margin. Choosing the lowest-wattage model suitable for a given appli-  
cation will provide lower procurement costs and lower long-term operating  
costs.  
Application Information  
1. Chassis Mounting Considerations: In order to minimize self-heating,  
DMS-PS-CM power supplies should always be mounted in either a  
vertical or horizontal position. Avoid mounting units upside-down or in  
close proximity to other heat-generating devices. Also, be sure to use  
the mounting hardware described in Figure 4 below in order to ensure  
a secure, vibration-resistant installation.  
When calculating total current requirements in installations employing  
three or more DMS-Series meters, it is acceptable practice to use each  
meter’s typical current consumption rating. However, be sure to consult  
the relevant product datasheets for all instrumentation comprising your  
application.  
Screw,  
Split Lock Washer,  
Flat Washer  
Panel/Chassis  
Threaded  
For applications where DMS-PS-CM power supplies will be powering only  
Murata Power Solution’s DPM’s, a 5-Watt DMS-PS3-CM can power up  
to four, standard intensity (‘-RS’ suffix) red-LED DMS-30PC meters: two  
meters on V1, and one meter each on V2 and V3. The same DMS-PS3-CM  
could also be used to power over 40 low-power red DMS-30PC meters  
(‘-RLsuffix), or over 800 DMS-30LCD non-backlit meters! Of course, these  
statements are made without regard to ground-loop problems that may be  
encountered when powering 800 DPM’s from a single power supply.  
Hole  
Screw,  
Flat Washer  
Panel/Chassis  
Flat Washer,  
Split Lock Washer,  
Nut  
Hole  
Figure 4. Chassis Mounting  
Scope Probe  
2. Bipolar Operation (See Figure 5): DMS-PS-CM power supplies’ fully  
isolated outputs allow for the generation of bipolar (positive and nega-  
tive) supply voltages. Bipolar outputs can be used to power dual-supply  
operational amplifiers, as well as any other type of instrumentation that  
requires bipolar supply voltages. However, please keep in mind that  
when connecting and operating any two outputs in this fashion, each  
output retains its maximum current rating.  
Oscilloscope  
V1  
+
BW = 20MHz  
DMS-PS-CM  
DMS-PS6-CM  
V1  
V2  
V3  
+
+
+
Figure 6. Measuring Ripple and Noise  
+24V –5V  
COM  
+5V  
Figure 5. Bipolar Connections  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 5 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Typical Performance Curves TA = +25°C, VIN = 120V @60Hz  
Noise and Ripple - 100% Load, 20MHz Bandwidth  
DMS-PS3-CM  
V1 (+5V)  
DMS-PS6-CM  
V1 (+24V)  
DMS-PS9-CM  
V1 (+24V)  
DMS-PS3-CM  
V2 (+4.85V)  
DMS-PS6-CM  
V2 (+4.85V)  
DMS-PS9-CM  
V2 (+4.85V)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 6 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Typical Performance Curves TA = +25°C, VIN = 120V @60Hz  
Transient Response - 10% to 100% Load Step  
DMS-PS3-CM  
V1 (+5V)  
DMS-PS6-CM  
V1 (+24V)  
DMS-PS9-CM  
V1 (+24V)  
DMS-PS3-CM  
V2 (+4.85V)  
DMS-PS6-CM  
V2 (+4.85V)  
DMS-PS9-CM  
V2 (+4.85V)  
0.51
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 7 of 8  
DMS-PS-CM Series  
High Efficiency, AC/DC Instrumentation Power  
Supplies with Individually Isolated Outputs  
Mechanical Specifications  
MECHANICAL DIMENSIONS: Inches (mm)  
5 Watt &  
10 Watt Models  
16 Watt Models  
TOLERANCES: 2 PL DEC 0.02 ( 0.51)  
3 PL DEC 0.010 ( 0.254)  
Power On  
V1 Adjust  
V1  
Power  
Adjust On  
Detail  
See detail  
+
V3  
®
®
0.188  
(4.8)  
TB3  
DMS-PSX-CM  
AC(L)  
AC/DC POWER SUPPLY  
+
V2  
2.835  
(72.0)  
AC(N)  
FG  
TB2  
TB1  
TB4  
+
V1  
1.42  
(36.1)  
4.625 (117.5)  
5.125 (130.2)  
1.000 (25.4)  
4.165 (105.8)  
5W models: 0.77 (19.6)  
10W models: 0.87 (22.1)  
16W models: 0.93 (23.6)  
0.125  
(3.2)  
USA:  
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com  
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com  
Canada:  
UK:  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED  
France:  
Germany:  
Japan:  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
11/24/08  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MPM_DMS-PS-CM.B02 Page 8 of 8  

相关型号:

DMS-PS4-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS4-CM-C

0-5V and 0-10V Input 3½ Digit, LED Display Process Control Monitors
MURATA

DMS-PS5-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS6-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS7-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS7-CM-C

0-5V and 0-10V Input 3½ Digit, LED Display Process Control Monitors
MURATA

DMS-PS8-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-PS9-CM

High Efficiency, AC/DC Instrumentation Power Supplies with Individually Isolated Outputs
MURATA

DMS-SA16-00A1E

15.6"/18.5" Open Frame PC
ADVANTECH

DMS-SA16-00A2E

15.6"/18.5" Open Frame PC
ADVANTECH

DMS-SA16_15

15.6"/18.5" Open Frame PC
ADVANTECH

DMS-ST06-40A1E

15.6"/18.5" Open Frame PC
ADVANTECH