TFS 914  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance:  
Input:  
23  
0
°C  
dBm  
50  
50  
Output:  
Characteristics  
Remark:  
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 914 MHz without any tolerance or limit.  
e
The values of absolute attenuation a  
temperature range is included in the production tolerance scheme.  
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating  
abs  
D a t a  
typ. value  
tolerance / limit  
a
2,3  
-
dB  
max.  
3,5  
914,0  
4,0  
dB  
Insertion loss  
e
fN  
MHz  
MHz  
dB  
Nominal frequency  
Passband  
PB  
14  
0,9  
MHz  
dB  
fN  
±
max.  
1,5  
Pass band ripple  
Absolute attenuation  
a
abs  
869  
891  
934  
955  
MHz  
MHz  
MHz  
MHz  
873  
894  
937  
960  
MHz  
MHz  
MHz  
MHz  
50  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
40  
30  
20  
40  
dB  
dB  
dB  
dB  
48  
60  
63  
-
max.  
10  
dBm  
Input power level  
OTR  
-
-
- 30 °C ... + 80 °C  
Operating temperature range  
Storage temperature range  
- 40 °C ... + 85 °C  
-
TC  
f
*
-35  
ppm/K  
Temperature coefficient of frequency  
*) f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).  
f
To  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 914.doc  
Version 1.1  
14.03.2006  
VI TELEFILTER  
Filter specification  
TFS 914  
2/5  
Filter characteristic  
0
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
-80  
-90  
-100  
-0.5  
-1  
-1.5  
-2  
-2.5  
-3  
904  
906  
908  
910  
912  
914  
916  
918  
920  
922  
924  
814  
834  
854  
874  
894  
914  
934  
954  
974  
994  
1014  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
6
4
1
2
3
4
5
6
Ground  
Input  
Ground  
Ground  
Output  
Ground  
914  
U11  
1
3
Date code  
1
3
Date code: Year + week  
U
V
W
...  
2006  
2007  
2008  
0,3X45°  
0,64  
6
4
2,54  
50 Test circuit  
L1  
2
5
L2  
SAW  
1, 3, 4, 6  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 914.doc  
Version 1.1  
14.03.2006  
VI TELEFILTER  
Filter specification  
TFS 914  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
3000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
: 12,00 ± 0,3  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
:
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
5,50 ± 0,05  
0,75  
2,00 ± 0,05  
8,00 ± 0,1  
1,50  
Ko  
Typ  
PIN Marker  
D1  
Ao  
4,30 ± 0,1  
4,30 ± 0,1  
9,5 ± 0,1  
Ct  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 12,4 +2/-0  
W2(max) : 18,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 914.doc  
Version 1.1  
14.03.2006  
VI TELEFILTER  
Filter specification  
TFS 914  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 914.doc  
Version 1.1  
14.03.2006  
VI TELEFILTER  
Filter specification  
TFS 914  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of development specification  
Name  
Date  
Strehl  
Strehl  
13.01.2005  
14.03.2006  
1.1  
- Add filter characteristic, typ. value and change stability characteristics  
- generation of filter specification  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS915

Development specification
VECTRON

TFS915A

Filter specification
VECTRON

TFS915B

VI TELEFILTER
VECTRON

TFS915D

Filter specification
VECTRON

TFS915F

Filter specification
VECTRON

TFS915H

Development specification
VECTRON

TFS915L

Filter specification
VECTRON

TFS922

Filter specification
VECTRON

TFS924B

Filter specification
VECTRON

TFS926

Filter specification
VECTRON

TFS92B

Filter specification
VECTRON

TFS92D

Filter specification
VECTRON