TFS915 [VECTRON]

Development specification; 开发规范
TFS915
型号: TFS915
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Development specification
开发规范

文件: 总5页 (文件大小:87K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs915.doc  
Version 1.1  
21.10.2003  
VI TELEFILTER  
Development specification  
TFS915  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance:  
Input:  
23  
0
°C  
dBm  
50  
50  
Output:  
Characteristics  
Remark:  
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 915 MHz without tolerance or limit.  
e
The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.  
D a t a  
typ. value  
tolerance / limit  
a
-
-
-
max.  
3
dB  
Insertion loss  
Nominal frequency  
e
fN  
915  
MHz  
MHz  
dB  
fN  
±
0,5  
Passband  
Pass band ripple  
max.  
1
a
Absolute attenuation  
abs  
0,3  
932  
1300  
MHz ...  
899 MHz  
1300 MHz  
2000 MHz  
-
-
-
min.  
min.  
min.  
40  
dB  
dB  
dB  
MHz ...  
MHz ...  
40  
30  
Operating temperature range  
Storage temperature range  
OTR  
-
-
- 10 °C ... + 60 °C  
- 40 °C ... + 85 °C  
TC  
f
*
T.B.D  
ppm/K  
-
Temperature coefficient of frequency  
Input power level  
-
max.  
10  
dBm  
*) f (Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).  
c
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D-14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs915.doc  
Version 1.1  
21.10.2003  
VI TELEFILTER  
Development specification  
TFS915  
2/5  
Construction, pin configuration and 50 - matching network  
(All dimensions in mm)  
4
6
Date code:  
Year + week  
915  
N
P
R
...  
2001  
2002  
2003  
R43  
Pin 1 Ground  
Date code  
1
1
3
Pin 2 Input  
Pin 3 Ground  
Pin 4 Ground  
Pin 5 Output  
Pin 6 Ground  
3
0,3X45°  
0,64  
2,54  
6
4
Tele Filter GmbH  
Potsdamer Straße 18  
D-14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs915.doc  
Version 1.1  
21.10.2003  
VI TELEFILTER  
Development specification  
TFS915  
3/5  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
Do  
E
:
:
12  
4
± 0,3  
± 0,1  
Po  
P 2  
D
o
:
1,5 + 0,1  
E
F
:
1,75 ± 0,1  
Ao  
F
:
5,5 ± 0,05  
0,75  
G (min) :  
D 1  
CT  
W
Bo  
P2  
P1  
:
2
± 0,05  
± 0,1  
:
8
G
D1(min) :  
1,5  
Ao  
Bo  
CT  
:
:
4,3 ± 0,1  
4,3 ± 0,1  
9,5 ± 0,1  
P1  
COVER TAPE  
:
W
2
Reel (all dimensions in mm):  
A
:
:
330  
12,4 + 2,0  
W1  
W2 (max) :  
18,4  
50  
C
A
N (min)  
C
:
N
:
13 +0,5/ -0,2  
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
Tele Filter GmbH  
Potsdamer Straße 18  
D-14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs915.doc  
Version 1.1  
21.10.2003  
VI TELEFILTER  
Development specification  
TFS915  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
pre-heating periods main-heating periods  
peak temperature  
Temperature:  
Time:  
150 °C - 170 °C  
60 sec. - 90 sec.  
over 200 °C  
20 sec. - 25 sec.  
255 °C ± 5 °C  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
temperature / °C  
time / sec.  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
Tele Filter GmbH  
Potsdamer Straße 18  
D-14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs915.doc  
Version 1.1  
21.10.2003  
VI TELEFILTER  
Development specification  
TFS915  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of development specification  
- Change of rejection in upper stop band  
Name  
Date  
1.10.2003  
21.10.2003  
Roizengaft  
Roizengaft  
1.1  
Tele Filter GmbH  
Potsdamer Straße 18  
D-14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS915A

Filter specification
VECTRON

TFS915B

VI TELEFILTER
VECTRON

TFS915D

Filter specification
VECTRON

TFS915F

Filter specification
VECTRON

TFS915H

Development specification
VECTRON

TFS915L

Filter specification
VECTRON

TFS922

Filter specification
VECTRON

TFS924B

Filter specification
VECTRON

TFS926

Filter specification
VECTRON

TFS92B

Filter specification
VECTRON

TFS92D

Filter specification
VECTRON

TFS935

Filter specification
VECTRON