TFS168A [VECTRON]

Filter specification; 过滤器规格
TFS168A
型号: TFS168A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:225K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 168a.doc  
Version 1.4  
02.05.2005  
VI TELEFILTER  
Filter specification  
TFS 168A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
121 || -33 pF  
Output:  
133 || -21.6 pF  
Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 168A is the minimum of the pass band attenuation a  
. The minimum of the pass band  
min  
rel  
attenuation a  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 1 dB  
min  
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 168,50 MHz without tolerance. The given values for the relative  
e c  
e
N
attenuation a  
and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency f is shifted due to the  
rel  
c
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .  
f
c
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
a
8,7  
dB  
max.  
10  
dB  
e
(reference level)  
Nominal frequency  
fN  
-
168.5  
-
MHz  
fC  
168.5  
MHz  
MHz  
dB  
Centre frequency  
Passband  
23,3  
0,3  
fN  
±
10  
MHz  
dB  
Pass band ripple  
max.  
1
Relative attenuation  
a
rel  
fN  
... fN  
±
10  
MHz  
0,3  
dB  
max.  
1
dB  
fN  
fN  
fN  
fN  
fN  
-
167  
21,5  
81,5  
141,5  
241,5  
MHz ... fN  
MHz ... fN  
MHz ... fN  
MHz ... fN  
MHz ... fN  
-
19,5  
81,5  
141,5  
241,5  
831,5  
MHz  
MHz  
MHz  
MHz  
MHz  
41  
39  
60  
60  
65  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
33  
33  
50  
50  
50  
dB  
dB  
dB  
dB  
dB  
+
+
+
+
+
+
+
+
Group delay ripple within PB  
Input power level ***  
35  
ns  
max.  
max.  
100  
20  
ns  
dBm  
Operating temperature range  
Storage temperature range  
OTR  
-
-
-20 °C .. + 80 °C  
-40 °C .. + 125 °C  
-
TC **  
f
-87  
ppm/K  
Temperature coefficient of frequency  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference  
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
**) f (Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).  
c
***) This power level is allowed for short term operation (<100 hours) only, the max. input power for continuous operation is 5 dBm.  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 168a.doc  
Version 1.4  
02.05.2005  
VI TELEFILTER  
Filter specification  
TFS 168A  
2/5  
Filter characteristic  
0
0
-1  
1.105  
1.03  
-6  
-12  
-18  
-24  
-30  
-36  
-42  
-48  
-54  
-60  
-2  
0.955  
0.88  
-3  
-4  
0.805  
0.73  
-5  
0.655  
0.58  
-6  
-7  
-8  
0.505  
0.43  
-9  
-10  
0.355  
109  
121  
133  
145  
157  
169  
181  
193  
205  
217  
229  
154 157 160 163 166 169 172 175 178 181 184  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
1
2
3
4
5
6
7
8
Ground  
Input RF Return  
Input  
Ground  
Ground  
Output RF Return  
Output  
Ground  
7
5
168A  
T19  
1
3
3
Date code  
1
Date code: Year + week  
T
2005  
2006  
2007  
U
V
...  
7
5
1,1  
2,54  
50 Ohm Test circuit  
L1  
L2  
3
7
SAW  
L2  
C2  
1, 4, 5, 8  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 168a.doc  
Version 1.4  
02.05.2005  
VI TELEFILTER  
Filter specification  
TFS 168A  
3/5  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 – 3, with exeption of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters peer reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
3000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
P2  
Po  
PIN Marker  
t
Do  
Ko  
Date Code  
Typ  
D1  
Ao  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 12,4 +2/-0  
W2(max) : 18,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 168a.doc  
Version 1.4  
02.05.2005  
VI TELEFILTER  
Filter specification  
TFS 168A  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 168a.doc  
Version 1.4  
02.05.2005  
VI TELEFILTER  
Filter specification  
TFS 168A  
5/5  
History  
Version  
1.0  
Reason of Changes  
Name  
Chilla  
Chilla  
Date  
Generation of “Development specification” according to customer requirements  
11.02.2004  
11.06.2004  
1.1  
created Filter specification  
added termination impedance  
added typical values  
added filter characteristics  
changed construction  
added test circuit  
changed packing  
1.2  
1.3  
changed pin connection  
Chilla  
Chilla  
29.07.2004  
03.02.2005  
added / changed limit line for 50dB and 60 dB attenuation  
added typical values, reflow profile updated  
1.3  
changed filter specification  
Chilla  
02.05.2005  
changed terminating impedance  
changed typical values  
changed limit line for 60 dB attenuation  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS170

Specification
VECTRON

TFS170D

Filter specification
VECTRON

TFS170D_06

Filter specification
VECTRON

TFS170F

Filter Specification
VECTRON

TFS170G

Filter specification
VECTRON

TFS170K

Filter Specification
VECTRON

TFS170L

Filter Specificationl
VECTRON

TFS170N

Filter specification
VECTRON

TFS170N_06

Filter specification
VECTRON

TFS171

Specification
VECTRON

TFS171A

Filter Specification
VECTRON

TFS172A

Filter specification
VECTRON