TFS172A [VECTRON]

Filter specification; 过滤器规格
TFS172A
型号: TFS172A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:161K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 172a.doc  
Version 1.2  
30.04.2004  
VI TELEFILTER  
Filter specification  
TFS 172A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
661 || -10.0 pF  
663 || -10.2 pF  
Output:  
Characteristics  
Remark:  
Reference level for the relative attenuation a  
of the TFS 172 A is the minimum of the pass band attenuation a  
. The minimum of the pass band  
min  
rel  
attenuation a  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 1,5 dB  
min  
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 172,800 MHz without tolerance. The given values for the relative  
e c  
e
N
attenuation a  
and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency f is shifted due to the  
rel  
c
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .  
f
c
D a t a  
typ. Value  
Limit  
Insertion loss  
a
e
10.5  
dB  
max.  
12,5  
dB  
(Reference level)  
Nominal frequency  
Centre frequency  
f
f
172,8 MHz  
-
N
c
172,8 MHz  
Passband  
PB  
f
±
4,42 MHz  
1,5 dB  
N
Passband ripple  
0.8  
1
dB  
max.  
Relative attenuation  
a
rel  
4,42 MHz  
f
f
±
dB  
max.  
1,5 dB  
N
...  
N
f
f
f
f
±
±
±
±
8
MHz ... f  
±
±
±
±
11  
25  
MHz  
MHz  
30  
40  
55  
65  
dB  
dB  
dB  
dB  
min. 27  
min. 35  
min. 45  
min. 55  
dB  
dB  
dB  
dB  
N
N
N
N
N
N
N
N
11 MHz ... f  
25 MHz ... f  
36,8 MHz ... f  
36,8 MHz  
100 MHz  
Group delay ripple within PB  
90  
ns  
ppm/K2  
max. 200  
-
ns  
Temperature coefficient of frequency Tcf  
- 18  
Frequency deviation of f over temperature T:  
c
f (Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)  
c
Operating temperature range  
Storage temperature range  
- 10 °C .. + 85  
- 40 °C .. + 125  
°C  
°C  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference  
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 172a.doc  
Version 1.2  
30.04.2004  
VI TELEFILTER  
Filter specification  
TFS 172A  
2/5  
Filter characteristic  
0
0
-1  
-2  
-3  
2.04  
1.89  
1.74  
1.59  
1.44  
-10  
-20  
-30  
B
d
B
d
-40  
-50  
-4  
-5  
s
n
i
n
i
µ
1.29  
e
d
u
e
d
u
n
i
y
t
i
t
i
a
l
1.14  
e
-60  
-6  
n
n
g
g
d
a
a
m
m
-70  
-7  
0.99  
-80  
-8  
0.84  
0.69  
0.54  
-90  
-9  
-100  
-10  
132.8 140.8 148.8 156.8 164.8 172.8 180.8 188.8 196.8 204.8 212.8  
166.8 168 169.2 170.4 171.6 172.8 174 175.2 176.4 177.6 178.8  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
9
7
6
4
10  
12  
1
2
3
4
5
6
Ground  
Ground  
Ground  
Output  
Ground  
Output  
S 172A  
S18  
1
3
7
8
9
10  
11  
12  
Ground  
Ground  
Ground  
Input  
Ground  
Input RF Return  
0,6  
1
Date code: Year + week  
S
T
U
...  
2004  
2005  
2006  
1
2,54  
7 ,0 +/-0,2  
L1  
10  
12  
6
50 Ohm Test circuit  
L2  
L4  
C2  
4
C1  
1,2,3,5,7,8,9,11  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 172a.doc  
Version 1.2  
30.04.2004  
VI TELEFILTER  
Filter specification  
TFS 172A  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 – 3, with exeption of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters peer reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
3000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
2
Po  
P
D
o
W
: 16,00 ± 0,3  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
:
:
:
:
:
:
:
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,1  
7,50 ± 0,1  
0,60  
2,00 ± 0,1  
8,00 ± 0,1  
1,50  
E
F
o
A
1
D
Ct  
W
o
B
G
5,50 ± 0,1  
7,50 ± 0,1  
P1  
Ct  
: 13,5 ± 0,1  
COVER TAPE  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 16,4 +2/-0  
W2(max) : 22,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 172a.doc  
Version 1.2  
30.04.2004  
VI TELEFILTER  
Filter specification  
TFS 172A  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
Temperature: 150 °C - 170 °C  
Time: 60 sec. - 90 sec.  
pre-heating periods  
main-heating periods  
over 200 °C  
20 sec. - 25 sec.  
peak temperature  
255 °C ± 5 °C  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 172a.doc  
Version 1.2  
30.04.2004  
VI TELEFILTER  
Filter specification  
TFS 172A  
5/5  
History  
Version  
1.0  
Reason of Changes  
Name  
Pfeiffer  
Chilla  
Date  
Generation of “development specification” according to customer requirements  
08.08.2003  
25.09.2003  
1.1  
Changed construction and pin connection  
Typical value for phase ripple and VSWR removed  
1.2  
Created filter specification  
Added source and load impedance  
Added typical values  
Chilla  
25.09.2003  
Changed construction  
Added plots  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS172B

Filter specification
VECTRON

TFS173A

Filter Specification
VECTRON

TFS174

Filter Specification
VECTRON

TFS1747

VI TELEFILTER
VECTRON

TFS1747_07

VI TELEFILTER
VECTRON

TFS174C

Filter Specification
VECTRON

TFS174D

Filter Specification
VECTRON

TFS175A

Filter Specification
VECTRON

TFS175D

Filter specification
VECTRON

TFS175K

SAW Filter, 1 Function(s), 175MHz,
MICROSEMI

TFS179

Filter Specification
VECTRON

TFS182

Filter specification
VECTRON