TFS170N [VECTRON]
Filter specification; 过滤器规格型号: | TFS170N |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:164K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 170n.doc
Version 1.6
11.04.2006
VI TELEFILTER
Filter specification
TFS 170N
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
780 Ω || -7,9 pF
760 Ω || -7.9 pF
Output:
Characteristics
Remark:
The reference level for the relative attenuation a of the TFS 170N is the attenuation at nominal frequency fN. The maximum attenuation in the pass band
rel
is defined as the insertion loss a . The nominal frequency fN is fixed at 170,6 MHz without any tolerance or limit. The values of relative attenuation a are
rel
e
guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
D a t a
typ. Value
Limit
Insertion loss
a
e
6,6 dB
max.
8
dB
Nominal frequency
Passband
f
-
170,6 MHz
N
PB
p-p
-
f
±
90
1
kHz
dB
N
Amplitude ripple in PB
Relative attenuation
0,4 dB
max.
a
rel
kHz
fN ± 90 kHz ... fN ± 200
-0,1 dB
min.
min.
-1
1
dB**
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
fN
fN
fN
fN
fN
fN
fN
±
±
±
±
±
±
±
0,2 MHz ... fN ±
0,4 MHz ... fN ±
0,6 MHz ... fN ±
0,8 MHz ... fN ±
1,6 MHz ... fN ±
0,4 MHz
0,6 MHz
0,8 MHz
1,6 MHz
MHz
5,8 MHz
2
23
35
45
48
55
60
65
70
70
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min. 13
min. 27
min. 40
min. 43
min. 47
min. 50
min. 45
min. 40
min. 40
3
3
MHz ... fN ±
5,8 MHz ... fN ±
35
75
75 MHz ... fN - 170
MHz
MHz
MHz
GHz
fN ± 35 MHz ... fN ±
fN
-
fN + 75 MHz ...
2
Time domain response***
5
µsec
17
35
80
83
84
dB
dB
dB
dB
dB
min. 10
min. 20
min. 76
min. 79
min. 80
dB
dB
dB
dB
dB
10 µsec
30 µsec
35 µsec
≥ 40 µsec
Group delay variation in PB
VSWR in PB
0,25 µs
max.
max.
1
µs
1,5:1
2:1
Input Power Level
-
max. 20
dBm
Temperature coefficient of frequency Tcf ****
Frequency inversion temperature T0
Operating temperature range
-0,05 ppm/K2
-
-
35
-
°C
- 33 °C .. +
- 40 °C.. +
85 °C
125 °C
Storage temperature range
-
IIP3 *****
36
dBm
min. 30
dBm
*) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) reference is max. loss in PB
***) Attenuation values for delays between 5µs and 35µs shall be interpolated linearly.
****)∆f(Hz) = TC (ppm/K2) x (T-T0)² x f (MHz)
f
To
*****) fin1= 170,5 MHz; fin2= 170,55 MHz; Pin= 0 dBm fmeasurement = 170,6 MHz
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 170n.doc
Version 1.6
11.04.2006
VI TELEFILTER
Filter specification
TFS 170N
2/5
Filter characteristic
0
0
-1
8.79
8.04
7.29
6.54
5.79
5.04
4.29
3.54
2.79
2.04
1.29
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-2
-3
-4
-5
-6
-7
-8
-9
-10
168.6 169 169.4 169.8 170.2 170.6 171 171.4 171.8 172.2 172.6
frequency in MHz
170.35170.4 170.45170.5 170.55 170.6 170.65 170.7 170.75 170.8 170.85
frequency in MHz
Construction and pin connection
(All dimensions in mm)
13,3±0,2
1
2
Input RF Return
Ground
3
Ground
4
5
Ground
Output
TFS 170N
6
7
8
Output RF Return
Ground
Ground
●
U15
9
10
Ground
Input
Date code
1,0±0,2
5
1
Date code: Year + week
U
V
W
...
2006
2007
2008
1,91±0,2
10
7,62±0,2
6
50 Ω Test circuit
10
5
L2
L1
C1
C2
1, 2, 3, 4, 6, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 170n.doc
Version 1.6
11.04.2006
VI TELEFILTER
Filter specification
TFS 170N
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
: 24,00 +0,30/-0,10
Po
P2
t
Do
Po
Do
E
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
P2
:
:
0,60
2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
Ao
:
:
1,50
7,10 ± 0,10
Ko
Typ
PIN Marker
D1
Ao
Bo
Ct
: 13,90 ± 0,10
: 21,5 ± 0,1
W
2
Reel (all dimensions in mm)
A
:330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
C
: 60
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 170n.doc
Version 1.6
11.04.2006
VI TELEFILTER
Filter specification
TFS 170N
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 170n.doc
Version 1.6
11.04.2006
VI TELEFILTER
Filter specification
TFS 170N
5/5
History
Version
Reason of Changes
Name
Date
1.0
1.1
generation of “Development specification” according to customer requirements
package tolerances modified
Pfeiffer
Steiner
13.07.2004
16.08.2004
1.2
terminating impedance added (preliminary value)
typical value and filter characteristic added
definition for insertion loss changed
Pfeiffer
17.09.2004
limits for relative attenuation corrected
1.3
1.4
terminating impedance fixed
air reflow temperature conditions modified
Pfeiffer
Pfeiffer
18.10.2004
04.11.2004
limit for maximum input power level fixed to 20 dBm
air reflow temperature conditions modified
1.5
1.6
operating temperature range extended
Pfeiffer
Pfeiffer
31.03.2006
11.04.2006
typical values and more details added for IP3
VSWR typo corrected
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明