TFS135C [VECTRON]
Filter Specification; 过滤器规格型号: | TFS135C |
厂家: | Vectron International, Inc |
描述: | Filter Specification |
文件: | 总5页 (文件大小:46K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
1/5
1. Measurement condition
Ambient temperature TA:
Input power level:
23 °C
0
dBm
Terminating impedances at f :
for input:
for output:
50 Ω
50 Ω
-19,2 pF
-16,4 pF
c
2. Characteristics
Remark:
Reference level for the relative attenuation a of the TFS 135C is the insertion loss. The minimum of the pass band attenuation a
is defined as
rel
min
the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
e
c
relative to the insertion loss a . The temperature coefficient of frequency Tcf is valid both for the reference frequency f and the frequency response of
e
c
the filter in the operating temperature range.
Data
typ. value
tolerance / limit
Insertion loss (Reference level)
a
14,6
-
dB
max
15,5
dB
e
Centre frequency
f
135,420 MHz ± 60
kHz
c
Relative attenuation
a
rel
f
f
f
±
±
±
1,25 MHz
-
max
min
min
3
40
38
dB
dB
dB
c
c
c
4
MHz
MHz
f
f
± 15 MHz
± 25 MHz
45...48 dB
50...60 dB
c
c
15
Group delay ripple:
f
± 1,0 MHz
80
ns
c
Temperature coefficient of frequency ( Tcf )
-19
ppm/K
Frequency deviation of f over temperature T:
c
∆f (Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
c
Operating Temperature Range
- 10 °C ... + 85
°C
Generated:
_____________
Checked/Approved:
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
2/5
3. Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
Datecode
Year+week
L
1999
2000
2001
N06
M
N
...
S 135C
1
2
3
4
5
6
7
8
Ground
Ground
Output
Ground
Ground
Ground
Ground
Ground
Input
9
10
11
12
Ground
Ground
Ground
50 Ω test circuit
9
3
OUT
IN
SAW
L1
L2
1,2,4,5,6,7,8,10,11,12
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
3/5
4. Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
5. Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
2000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
Po
Do
E
:
16
4
± 0,3
± 0,1
:
Po
2
P
Do
:
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
0,6
E
F
:
A
o
F
:
D
1
G (min) :
CT
W
B
o
P2
P1
:
2
8
± 0,1
± 0,1
:
G
D1(min) : 1,5
Ao
Bo
CT
:
:
5,5 ± 0,1
7,5 ± 0,1
13,5 + 0,1
P1
COVER TAPE
:
W
2
Reel (all dim ensions in m m ):
A
:
:
33 0
W1
16,4 +2
22 ,4
W2 (m ax)
:
N (m in)
C
:
50
C
A
:
13 +0 ,5 / -0,2
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the
sprocket holes.
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
4/5
6. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °
main-heating periods
peak temperature
255 °C ± 5 °C
20 sec. - 25 sec.
Cover 200 °C
60 sec. - 90 sec.
Air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
22.03.01
VI TELEFILTER
Filter Specification
TFS 135 C
5/5
7. History
Version Reason of Changes
Name
Date
1.0
2.0
- generate specification
Pfeiffer
Pfeiffer
09.02.01
22.03.01
- new definition of insertion loss (minimum of the passband attenuation)
- new teminating impedances at fC
- fC = 135,420 MHz ± 60 kHz
- change from nominal frequency to centre frequency as basis for relative attenuation
- ae = 15,5 dB
- group delay ripple = 80 ns
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
相关型号: