TFS140A2 [VECTRON]

Filter Specification; 过滤器规格
TFS140A2
型号: TFS140A2
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器
文件: 总5页 (文件大小:104K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
File name: Tfs 140A2.doc  
Version 1.6  
14.11.2001  
VI TELEFILTER  
Filter Specification  
TFS 140A2  
1/5  
1. Measurement condition :  
Ambient temperature TA:  
23 °C  
Input power level:  
0 dBm.  
Terminating impedances at f * ) :  
c
for input: 214  
- 13,022 pF.  
- 13,607 pF.  
for output: 189  
2. Characteristics :  
Remark: Reference level for the relative attenuation a  
of the TFS 140A1 is the minimum of the pass band attenuation a  
. The minimum of  
min  
rel  
the pass band attenuation a  
min  
is defined as the insertion loss a . The reference frequency f is the arithmetic mean value of the upper and lower  
e c  
frequencies at the 3 dB filter attenuation level relative to the insertion loss a . The temperature coefficient of frequency Tcf is valid both for the  
e
reference frequency f and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating  
c
temperature range is not included in the production tolerance scheme  
Data  
typ. value  
tolerance / limit  
Insertion loss (Reference level)  
a
23,5 dB  
max. 25 dB  
e
Centre frequency  
f
at ambient temperature TA (fCAT  
)
140,01 MHz  
140 ± 0,10 MHz  
c
Pass band at ambient temperature TA:  
fC - 1,55 MHz.....fC + 1,55 MHz  
Amplitude ripple (p-p):  
fC ...  
C ± 1,35 MHz  
f
C ± 1,35 MHz  
0,5 dB  
0,7 dB  
f
f
C ± 1,42 MHz  
Bandwidth at ambient temperature:  
1,0 dB - band width  
2,88 MHz  
3,15 MHz  
3,83 MHz  
4,20 MHz  
4,24 MHz  
3
dB - band width  
min. 3,0 MHz  
20 dB - band width  
40 dB - band width  
45 dB - band width  
max. 4,4 MHz  
max. 5,0 MHz  
Relative attenuation  
a
rel  
fC  
fC  
±
1,5  
MHz  
-
max.  
3 dB  
............  
MHz  
MHz  
f
f
C ± 2,2  
C ± 2,5  
..... fC  
..... fC  
±
±
2,5  
40  
MHz  
MHz  
45...55 dB  
60....70 dB  
min. 40 dB  
min. 45 dB  
Group delay ( mean value in pass band ):  
Group delay ripple in pass band (p-p):  
Deviation from linear phase in pass band (p-p):  
2,49 µs  
65 ns  
3,5 ° (r.m.s. 1,4°)  
max. 2,5 µs  
max. 100 ns  
max. 10°  
S11 in PB :  
S22 in PB :  
8
8
dB  
dB  
Triple transit attenuation compared to main signal  
Crosstalk  
52 dB  
55 dB  
min. 40 dB  
Substrate material  
Frequency inversion temperature ( To )  
Temperature coefficient of frequency ( Tcf )  
Quartz  
25° C  
-0,045  
f (Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)  
ppm/K²  
Frequency deviation of f over temperature: ** )  
c
c
Operating temperature range  
Storage temperature range  
0 °C ... + 70 °C  
- 40 °C ... + 85 °C  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
** ) fTo is reference frequency f at frequency inversion temperature (To )  
c
Generated:  
Dunzow W.P.  
Dr. Bert Wall  
Checked / Approved:  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs 140A2.doc  
Version 1.6  
14.11.2001  
VI TELEFILTER  
Filter Specification  
TFS 140A2  
2/5  
3. Package : ( all dimensions in mm )  
TFS  
140A1  
N22  
Datecode: Year+week  
1999  
2000  
L
M
1
19+-00,,1200  
N
2001  
.......  
1,02  
1
Pin 10  
Input  
Pin 1  
Pin 5  
Input RF Return  
Output  
Pin 6  
Pin 2 - 4, 7 - 9  
Output RF Return  
Package Ground  
1,91  
7,62  
4. 50 matching network ( see Application Note ) :  
Scheme 1.  
L21 L22  
L3 R1  
1 2  
3
4
5
6
50  
50  
10 9 8 7  
R2 L4  
L11  
L12  
L11  
L21  
L3 R1  
1 2  
3 4 5  
50  
50  
10 9 8 7  
6
L22  
R2 L4  
L12  
Scheme 2.  
1 2  
L21  
L22  
R1  
3
4
5
C1  
50  
50  
C2  
10 9 8 7  
6
R2  
L11  
L12  
L11  
L21  
R1  
1 2  
3
4
5
6
C2  
C1  
50  
50  
L12  
L22  
10 9 8 7  
R2  
For final test we use scheme 1.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs 140A2.doc  
Version 1.6  
14.11.2001  
VI TELEFILTER  
Filter Specification  
TFS 140A2  
3/5  
5. Stability characteristics :  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 14 Test N  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
6. Packing :  
Tape & Reel:  
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
Trailer  
2000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
W
:
:
:
:
:
:
:
:
:
32  
4
1,5  
1,75 ± 0,1  
28,4 ± 0,1  
14,2 ± 0,1  
0,6  
± 0,3  
± 0,1  
+ 0,1  
Po  
Do  
E
So  
F
G (min)  
P2  
P1  
pull off direction  
X-X  
W
X
Po  
P1  
P2  
E
t
Do  
o
S
o
B
t
C
2
± 0,1  
± 0,1  
view direction  
Ko  
12  
2,0  
7,1  
19,6 ± 0,1  
2,0 ± 0,1  
D1(min) :  
Ao  
D1  
Ao  
Bo  
Ko  
t
:
:
:
:
:
± 0,1  
X
SPEC-Gurt 0061/ 19X6,5  
Q09016:02.001  
Jul.10,01  
0,35 ± 0,35  
25,5 ± 0,1  
Ct  
W2  
Reel (all dimensions in mm):  
A
W1  
W2(max) :  
:
:
330  
32,4 + 2  
38,4  
N
C
A
N(min)  
C
:
:
100  
13 ± 0,5 / - 0,2  
W1  
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape in the above shown direction.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs 140A2.doc  
Version 1.6  
14.11.2001  
VI TELEFILTER  
Filter Specification  
TFS 140A2  
4/5  
7. Air reflow temperature conditions :  
1st and 2nd air reflow profile  
Name:  
pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: tft@telefilter.com  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
File name: Tfs 140A2.doc  
Version 1.6  
14.11.2001  
VI TELEFILTER  
Filter Specification  
TFS 140A2  
5/5  
History :  
Version Reason of changes  
Name  
Date  
1.0  
1.1  
Generate specification according to customer requirements.  
Dunzow W.  
Dunzow W.  
15.05.2000  
31.05.2000  
Add theoretical matching network scheme.  
Change filter name from TFS 140A11 to TFS 140A1.  
Change input and output pin positions according to customer requirements.  
1.2  
1.3  
Correct errors in matching network scheme.  
Dunzow W.  
Dunzow W.  
05.06.2000  
22.06.2000  
Change limit value ILo : from ILo = max. 19 dB to ILo = max. 20 dB.  
Correct wrong unit for limit value of TTS ( ns  
Add VSWR according to customer requirement.  
dB ).  
1.4  
1.5  
Edit typical values after measured.  
Edit termination impedances .  
Dunzow W.  
Dunzow W.  
18.07.2000  
25.10.2001  
correct 5. Stability characteristics .  
add one modified matching networks.  
change limit lines and tolerance for centre frequency.  
1.6  
change limit value of the group delay ripple :  
Dunzow W.  
14.11.2001  
from max.200 ns to max.100 ns according to customer requirements.  
change termination impedances and insertion loss .  
change specification name (from 140A1 to 140A2 )  
delete limits value for VSWR.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS140A3

Filter Specification
VECTRON

TFS140AE

Filter specification
VECTRON

TFS140AF

Filter specification
VECTRON

TFS140AG

Filter specification
VECTRON

TFS140AL

Filter specification
VECTRON

TFS140AN

Filter specification
VECTRON

TFS140AP

Filter specification
VECTRON

TFS140AR

Filter specification
VECTRON

TFS140AS

Filter specification
VECTRON

TFS140AT

Filter specification
VECTRON

TFS140AU

Filter specification
VECTRON

TFS140AV

Filter specification
VECTRON