1. Measurement condition  
Ambient temperature TA:  
23 °C  
Input power level:  
0 dBm.  
Terminating impedances at f :  
c
for input:  
448 - 13,8 pF.  
374 - 14,5 pF.  
for output:  
50  
Q-value of matching elements:  
2. Characteristics  
Remark: Reference level for the relative attenuation a  
of the TFS 140A1 is the minimum of the pass band attenuation a  
. The  
rel  
min  
minimum of the pass band attenuation a  
min  
is defined as the insertion loss a . The reference frequency f is the arithmetic mean value of the  
e
c
upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a . The temperature coefficient of frequency Tcf is  
e
valid both for the reference frequency f and the frequency response of the filter in the operating temperature range. The frequency shift of  
c
the filter in the operating temperature range is not included in the production tolerance scheme  
Data  
typ. value  
tolerance / limit  
Insertion loss (Reference level)  
a
18,5...19,0 dB  
max. 20 dB  
e
Centre frequency  
f
at ambient temperature TA (fCAT  
)
140,01 MHz  
140 ± 0,06 MHz  
c
Pass band at ambient temperature TA:  
fC - 1,55 MHz.....fC + 1,55 MHz  
Amplitude ripple (p-p):  
fC ... fC ± 1,35 MHz  
0,5 dB  
0,7 dB  
fC ± 1,35 MHz fC ± 1,42 MHz  
Bandwidth at ambient temperature:  
1,0 dB - band width  
2,88 MHz  
3,15 MHz  
3,83 MHz  
4,20 MHz  
4,24 MHz  
3
dB - band width  
min. 3,10 MHz  
20 dB - band width  
40 dB - band width  
45 dB - band width  
max. 4,60 MHz  
max.11,88 MHz  
Relative attenuation  
fC  
fC ± 2,30 MHz ..... fC ± 5,94 MHz  
a
rel  
fC ± 1,55 MHz  
-
max.  
3 dB  
............  
45...55 dB  
60....70 dB  
min. 40 dB  
min. 45 dB  
fC ± 5,94 MHz ..... fC ± 40  
MHz  
Group delay ( mean value in pass band ):  
Group delay ripple in pass band (p-p):  
Deviation from linear phase in pass band (p-p):  
2,49 µs  
140...170 ns  
5...6 ° (r.m.s. 1,4°)  
max. 2,5 µs  
max. 200 ns  
max. 10°  
Input VSWR (S11) in PB :  
Output VSWR (S22) in PB :  
Triple transit attenuation compared to main signal  
Crosstalk  
1,3 : 1  
1,4 : 1  
41...42 dB  
52...55 dB  
max. 2 : 1  
max. 2 : 1  
min. 40 dB  
Substrate material  
Frequency inversion temperature ( To )  
Temperature coefficient of frequency ( Tcf )  
Quartz  
25° C  
-0,045  
ppm/K²  
Frequency deviation of f over temperature: * )  
f (Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)  
c
c
Operating temperature range  
Storage temperature range  
0 °C ... + 70 °C  
- 40 °C ... + 85 °C  
* ) fTo is reference frequence f at frequency inversion temperature (To )  
c
Generated:  
Dunzow W.P.  
Dr. Bert Wall  
Checked/Approved:  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs 140A1.doc  
Version 1.4  
18.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 140A1 - 2/5  
3. Package  
Datecode: Year+week  
K
L
M
1998  
1999  
2000  
TFS 140A1  
M22  
.
.......  
Pin 10  
Pin 1  
Pin 5  
Pin 6  
Input  
Input RF Return  
Output  
Output RF Return  
Package Ground  
Pin 2 - 4, 7 - 9  
4. 50 matching network ( see Application Note ):  
10  
9
8
7
6
5
L1
50 Ω  
TFS  
140A1  
M22  
L4
R2
L3
R1
50 Ω  
.
1
2
3
4
L2
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Vectron International, Inc.  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs 140A1.doc  
Version 1.4  
18.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 140A1 - 3/5  
5. Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Damp heat:  
(cycle)  
25 °C to 55°C / 95% r.H. / 10 cycles  
DIN IEC 68 - 2 – 30 Db  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
6. Packing  
Tape & Reel:  
DIN IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
Real of empty components at start:  
Real of empty components at start including leader:  
Trailer  
2000  
min 300 mm  
min 500 mm  
min 300 mm  
EMBOSSED CARRIER TAPE  
Tape (all dimensions in mm)  
Po  
P
2
D
o
W
:
:
:
:
:
:
:
:
32  
4
1,5  
1,75 ± 0,1  
14,2 ± 0,1  
0,6  
± 0,3  
± 0,1  
+ 0,1  
Po  
Do  
E
E
A
o
F
F
D
1
G (min)  
P2  
P1  
CT  
W
B o  
2
± 0,1  
± 0,1  
12  
2,0  
7,1  
19,6 ± 0,  
0,3  
D1(min) :  
Ao  
Bo  
t
:
:
:
:
± 0,1  
G
± 0,05  
P1  
CT  
25,5 ± 0,1  
COVER TAPE  
W
2
Reel (all dimensions in mm):  
A
:
330  
32,4 +2  
38,4  
100  
13 +0,5/-0,2  
W1  
:
:
W2 (max) :  
N (min)  
C
C
A
:
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs 140A1.doc  
Version 1.4  
18.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 140A1 - 4/5  
7. Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name:  
pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
0
10  
20  
30  
40  
50  
60  
70  
80  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs 140A1.doc  
Version 1.4  
18.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 140A1 - 5/5  
History  
Version  
1.0  
Reason of Changes  
Generate specification according to customer requirements.  
Name  
Date  
Dunzow W.  
Dunzow W.  
15.05.2000  
31.05.2000  
1.1  
Add theoretical matching network scheme.  
Change filter name from TFS 140A11 to TFS 140A1  
Change input and output pin positions according to customer requirements.  
1.2  
1.3  
Correct errors in matching network scheme.  
Dunzow W.  
Dunzow W.  
05.06.2000  
22.06.2000  
Change limit value ILo : from ILo = max. 19 dB to ILo = max. 20 dB  
Correct wrong unit for limit value of TTS ( ns dB ).  
Add VSWR according to customer requirement.  
Edit typical values after measured.  
1.4  
Dunzow W.  
18.07.2000  
Edit termination impedances .  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed  
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS140A2

Filter Specification
VECTRON

TFS140A3

Filter Specification
VECTRON

TFS140AE

Filter specification
VECTRON

TFS140AF

Filter specification
VECTRON

TFS140AG

Filter specification
VECTRON

TFS140AL

Filter specification
VECTRON

TFS140AN

Filter specification
VECTRON

TFS140AP

Filter specification
VECTRON

TFS140AR

Filter specification
VECTRON

TFS140AS

Filter specification
VECTRON

TFS140AT

Filter specification
VECTRON

TFS140AU

Filter specification
VECTRON