PACC-MS005 [TELEDYNE]

FREEHAND PROBE HOLDER ZS;
PACC-MS005
型号: PACC-MS005
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

FREEHAND PROBE HOLDER ZS

文件: 总56页 (文件大小:5517K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Oscilloscope Probes and  
Probe Accessories  
Learn More: teledynelecroy.com/probes  
PROBE SELECTION  
GUIDE  
Teledyne LeCroy has a wide variety of world class probes and amplifiers to compliment its  
product line. From the ZS high impedance active probes to the DH Series Differential  
High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and  
probe accessories provide optimum mechanical connections for signal measurement.  
Front Cover:  
DH Series Differential High-bandwidth Probes  
60 V Common Mode Differential Probes - p. 4 - 5  
DL05-HCM  
DL10-HCM  
Active Voltage Rail Probes - p. 6 - 9  
RP4030  
Active Voltage Probes - p. 10 - 13  
ZS1000  
ZS1500  
ZS2500  
ZS4000  
Current Probes - p. 14 - 17  
CP030  
CP030A  
CP031  
CP031A  
CP150  
CP500  
CA10  
Differential Probes - p. 18 - 27  
ZD200  
ZD500  
ZD1000  
ZD1500  
AP033  
D410-A-PB2  
D420-A-PB2  
D400A-AT-PB2  
D610-A-PB2  
D610-A-PL  
D620-A-PB2  
D620-A-PL  
D600A-AT-PB2  
D600A-AT-PL  
D830-PB2  
D830-PL  
D1330-PL  
DH08-PB2  
DH08-PL  
DH13-PL  
DH16-PL  
DH20-PL  
DH25-2.92MM  
DH30-2.92MM  
2
Learn More: teledynelecroy.com/probes  
High Voltage Differential Probes - p. 28 - 33  
HVD3102A  
HVD3106A  
HVD3106A-6M  
HVD3206A  
HVD3206A-6M  
HVD3220  
HVD3605A  
AP031  
High Voltage Probes - p. 34 - 37  
HVP120  
PPE4KV  
PPE5KV  
PPE6KV  
High Voltage Fiber Optically-isolated Probes - p. 38 - 41  
HVFO108  
Optical-To-Electrical Converters - p. 42 - 45  
OE6250G-M  
OE695G  
OE425  
OE455  
OE525  
OE555  
Passive Probes - p. 46 - 49  
PP016  
PP018  
PP019  
PP020  
PP021  
PP022  
PP023  
PP024  
PP025  
PP026  
Probe Adapters - p. 50 - 51  
CA10  
TPA10  
Transmission Line Probes - p. 52 - 53  
PP066  
3
60 V COMMON MODE DIFFERENTIAL PROBES  
The 60 V Common Mode Differential Probes are the ideal probes for  
low voltage GaN power conversion measurement with the highest  
accuracy, best CMRR, and lowest noise.  
Ideal Probes for 48 V GaN  
Power Conversion  
Lowest Noise and  
Highest Rejection  
60 V of common mode and 80 V  
differential input range with 1 GHz of  
bandwidth, make these probes ideal  
for low voltage GaN power conversion  
measurements. The 60 V of common  
mode is well suited for handling any  
The Common Mode Rejection Ratio  
(CMRR) is exceptional to very high  
frequencies. This provides for the best  
measurement performance when  
measuring very fast slew rate (high  
dV/dt) PWM signals typical of GaN  
Teledyne LeCroy  
60 V Common Mode  
Differential Probe Model  
Numbers:  
float of the battery and bulk/absorption devices and systems. Exceptional  
DL05-HCM  
voltage during charging, while the 80 V  
differential input range provide margin  
for any overshoot.  
CMRR combined with low probe noise  
and high offset capability makes the  
probes capable of measuring very  
small control signals floating on high  
common mode voltages.  
DL10-HCM  
Highest Accuracy  
The DL-HCM probes are calibrated for  
Key Applications  
48 V motors and drives  
high-precision measurements to within Wide Variety of Tips  
0.5% at DC and 0.1 dB flatness from  
High-power DC-DC converters  
The DL-HCM probes provide the  
GaN-based PDNs  
DC to 100 MHz. This provides for high  
perfect combination of high  
AC-DC switch-mode power  
accuracy of top and base voltage levels performance and flexibility for  
supplies  
of pulse-width modulated signals. The  
Precision Gain Calibration capability  
connecting to any device under test.  
An optional accessory kit and high  
Wireless charging systems  
Gate-drive measurements  
permits further measurement precision temperature solder-in tip are available  
by improving the gain accuracy and  
removing small offset drifts from the  
measurement configuration.  
for further connectivity options.  
Key Features  
Ideal probe for 48 V Power Conversion  
500 MHz and 1 GHz bandwidth  
Ordering Information  
80 V dynamic range  
Product Description  
Product Code  
60 V common mode  
500 MHz 60V Common Mode Differential Probe.  
Includes standard set of leads and tips.  
1 GHz 60V Common Mode Differential Probe.  
Includes standard set of leads and tips.  
DL-HCM series high-temperature solder-in tip,  
30 MHz bandwidth, 1 meter length.  
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and  
Y-banana adaptor.  
DL05-HCM  
Highest accuracy  
DL10-HCM  
0.5% gain accuracy  
DL-HCM-HiTemp  
DL-HCM-Acc-Kit  
Precision gain calibration  
Best LF flatness (0.1 dB)  
Standard leads and tips  
High performance solder-in tips (Qty. 2)  
2” solder-in tip  
Lowest noise and highest rejection  
Browser  
Y-lead socket (2” and 5”)  
Mini grabbers (Qty. 3)  
Ground lead  
Single pin (Qty. 6)  
Straight pin header (Qty. 2)  
4
60 V COMMON MODE DIFFERENTIAL PROBES  
DL05-HCM  
500 MHz (guaranteed, without leads)  
500 MHz (High performance solder-in and browser)  
500 MHz (2" Y-lead/solder-in)  
DL10-HCM  
1 GHz (guaranteed, without leads)  
1 GHz (High performance solder-in and browser)  
800 MHz (2" Y-lead)  
Bandwidth*  
500 MHz (5" Y-lead)  
700 MHz (solder-in)  
30 MHz (Hi-Temp lead)  
500 MHz (5" Y-lead)  
30 MHz (Hi-Temp lead)  
Rise Time (10-90%)*  
700 ps  
350 ps  
Differential Voltage Range  
Common Mode Voltage Range  
80 V (DC + peak AC) from 200 mV/div to 20 V/div  
±60 V (DC + peak AC)  
Maximum Input Voltage to Earth 80 V (DC + peak AC), max 60 V DC (either input to ground)  
Maximum Safe Input Voltage  
Sensitivity  
For Hand-held use: 28.28 Vrms or 60 V DC (referenced to ground) per IEC/EN 61010-031:2015  
200 mV/div to 1 V/div (7.8x)  
1.02 V/div to 2.5 V/div (17.5x)  
2.55 V/div to 20 V/div (70x)  
±0.5% (guaranteed)  
≤ 0.075%/°C, can be calibrated out with precision gain cal  
DC to 100MHz: 0.1 dB  
DC Gain Accuracy  
DC Gain Drift  
Frequency Response Flatness  
Offset Range  
Attenuation  
±60V  
7.8x / 17.5x / 70x  
Input Impedance  
Input/Output Coupling  
Output Termination  
Interface  
200 kΩ || 0.6 pF (between inputs), 100 kΩ || 1 pF (either input to ground)  
DC  
50 Ω  
ProBus  
Cable Length  
1.42 m from probe sockets to oscilloscope connection  
Noise and Rejection  
CMRR  
DC - 10 kHz: 80 dB  
100 kHz: 70 dB  
1 MHz: 55 dB  
DC - 10 kHz: 80 dB  
100 kHz: 70 dB  
1 MHz: 55 dB  
100 MHz: 50 dB  
1 GHz: 30 dB  
100 MHz: 50 dB  
500 MHz: 35 dB  
Noise (Probe)  
200 mV/div to 1 V/div: 3.25mVrms  
1.02 V/div to 2.5 V/div: 4.5mVrms  
2.55 V/div to 20 V/div: 14.5mVrms  
200 mV/div to 1 V/div: 4.3mVrms  
1.02 V/div to 2.5 V/div: 6mVrms  
2.55 V/div to 20 V/div: 20mVrms  
DL-HCM Probe  
Straight Pin Header  
Qty: 2  
Browser  
Qty: 1  
High Performance  
Solder-in  
Qty: 2  
2” Y-lead  
Qty: 1  
2” Solder-in  
Qty: 1  
High Temperature Lead  
Qty: 1  
Ground lead  
Qty: 1  
(Optional –  
Included with  
DL-HCM-HiTemp)  
5” Y-lead  
Qty: 1  
Y-banana Adaptor  
Qty: 1  
(Optional –  
Included with DL-HCM-Acc-Kit)  
Single Pin  
Qty: 6  
Hands Free Probe Holder  
(Optional –  
Included with  
DL-HCM-Acc-Kit)  
Mini-Grabber  
Qty: 1  
Micro-Grabbers Mini-Grabbers  
Qty: 2  
Qty: 2  
(Optional –  
Included with DL-HCM-Acc-Kit)  
5
ACTIVE VOLTAGE RAIL PROBE  
6
ACTIVE VOLTAGE RAIL PROBE  
The RP4030 is designed specifically to probe a 50Ω DC power/voltage rail.  
Teledyne LeCroy  
Active Voltage Rail Probe  
Model Numbers:  
The probe has large built-in offset, low attenuation (noise), and high DC input  
impedance. Built-in offset and low attenuation permit the power/voltage rail  
to be offset in the oscilloscope by its mean DC voltage with high oscilloscope  
gain (sensitivity) to achieve a noise-free view of small signal variations. The  
high DC input impedance eliminates loading of the DC rail.  
RP4030  
Opposite page:  
Active Voltage Rail Probes RP4030 with a  
WaveRunner 8000HD High Definition Oscilloscope.  
7
ACTIVE VOLTAGE RAIL PROBE  
Teledyne LeCroy  
Active Voltage Rail Probe  
Model Number:  
RP4030  
Key Features  
4 GHz Bandwidth  
±30V Offset Capability  
±800mV Dynamic Range  
50 kΩ DC Input Impedance  
Large Offset Range  
1.2x Attenuation (Low Additive  
Noise, ~5%)  
Permits the DC signal to be displayed in the vertical center of the oscilloscope  
grid with a high-sensitivity gain setting.  
MCX terminated cable with wide  
variety of connections:  
Low Attenuation and Noise  
The probe attenuation is a nominal 1.2x coupled to the oscilloscope at DC 50 Ω.  
This keeps additive noise to a minimum, and makes it exceptionally useful with  
High Definition oscilloscopes for lowest noise at highest sensitivity gain settings.  
Solder-in (4 GHz)  
Coaxial Cable to  
U.FL receptacle (3 GHz)  
High DC Input Impedance  
MCX PCB Mount (4 GHz)  
Browser (350 MHz)  
50 kΩ input impedance at DC effectively eliminates probe loading on the DC  
power/voltage rail and provides for more accurate measurements and signal  
fidelity.  
ProBus Interface  
8
ACTIVE VOLTAGE RAIL PROBE  
4 GHz of Bandwidth  
Wide Assortment of  
Tips and Leads  
Provides maximum bandwidth for probing near the CPU,  
and the perfect match with the 4 GHz, 12 bit WavePro HD  
when making power integrity measurements.  
The RP4030 is supplied standard with solder-in and coaxial  
cables with MCX and U.FL PCB receptacle mounts. A  
browser tip is optionally available. Additional receptacles or  
leads may be purchased as accessories and left connected  
in circuit for easy connection of different signals during  
different test or validation stages.  
Specifications  
Ordering Information  
Electrical Characteristics  
Bandwidth  
4 GHz (guaranteed, MCX receptacle)  
4 GHz (typical, solder-in lead)  
3 GHz (typical, U.FL cable +  
receptacle)  
Product Description  
Product Code  
Power/Voltage Rail Probe  
RP4030  
350 MHz (typical, browser)  
4 GHz, 1.2x, ±30V offset, ±800mV dynamic range  
Rise Time (10-90%)  
110 ps (typical, MCX receptacle or  
solder-in lead)  
Includes Qty. 1 ProBus compatible probe offset amplifier with 50 kΩ DC  
input impedance and SMA input connection for provided 0.9m SMA to  
MCX extension cable. Also supplied are Qty. 3 MCX solder-in leads, Qty.  
3 MCX PCB Mounts, Qty. 3 MCX to U.FL coaxial cables, Qty. 5 U.FL PCB  
Mounts, Qty. 1 MCX to SMA adapter, and soft carrying case. Browser tip  
sold separately.  
350 MHz Browser Tip Accessory  
Includes 0 Ω (1x), 450 Ω (10x) and 950 Ω (20x) tips.  
Input Capacitance  
DC Input Resistance  
Offset Range  
0.1 uF (in series with 50Ω)  
50 kΩ  
±30V  
1.2x  
±800 mV  
±50V  
~5% additive to oscilloscope noise  
Attenuation  
RP4000-BROWSER  
Input Dynamic Range  
Non-destruct Voltage  
Noise  
Oscilloscope Termination  
DC 50Ω  
Environmental  
Operating Temperature Range  
0 to 50 ºC  
Non-operating Temperature Range -40 to +70 ºC  
Humidity  
5% to 80% RH (non-condensing) up  
to 30 ºC, decreasing linearly to to 45%  
RH at 50 ºC  
Operating Altitude  
3000 meters maximum  
Physical  
RP4030  
Probe: 38.1 mm W x 15.9mm H x  
73mm L (1-1/2” x 5/8” x 2-7/8”)  
SMA to MCX Cable: 914mm L (36”)  
MCX to Solder-in Lead: 191mm (7-  
1/2”) usable length  
MCX to U.FL Plug Coaxial Cable:  
102mm (4”) usable length  
Accessories and Consumables  
RP4000-BROWSER  
11.9mm W x 9.5mm H x 38mm L  
(15/32” x 3/8” x 1-1/2”)  
Qty. 3 MCX 4 GHz solder-in leads  
RP4000-MCX-LEAD-SI  
RP4000-MCX-PCBMOUNT  
RP4000-MCX-CABLE-UFL  
SMA to SMA Cable: 1m (39-3/8”)  
usable length  
Qty. 10 MCX PCB mount receptacle  
Qty. 3 MCX to U.FL 3 GHz ultra-mini  
coax cable  
Other  
Oscilloscope Interface  
Software Requirements  
Teledyne LeCroy ProBus  
Qty. 10 U.FL PCB mount receptacles  
RP4000-UFL-PCBMOUNT  
Teledyne LeCroy MAUI 8.2.1.1 or  
higher  
Weight  
119 g (0.26 lb)  
9
ACTIVE VOLTAGE PROBES  
10  
ACTIVE VOLTAGE PROBES  
Engineers must commonly probe high-frequency signals with high  
Teledyne LeCroy  
signal fidelity. Typical passive probes with high input R and C provide good  
response at lower frequencies, but inappropriately load the circuit and  
distort signals at higher frequencies. Active voltage probes feature both  
high input R and low input C to reduce circuit loading across the entire  
probe/oscilloscope bandwidth. With low circuit loading and a form factor  
that allows probing in confined areas, the active voltage probe becomes  
the everyday probe for all different types of signals and connection points.  
Active Voltage Probe  
Model Numbers:  
ZS1000  
ZS1500  
ZS2500  
ZS4000  
Opposite page:  
ZS Series High Impedance Active Probe  
11  
ZS SERIES ACTIVE PROBES  
The ZS Series probes are high impedance, low capacitance active probes that  
maintain high signal fidelity through 4 GHz. A small form factor and a wide variety  
of accessories ensures the ZS probe meets every difficult probing challenge.  
Engineers must commonly probe high frequency signals with high signal fidelity.  
Typical passive probes with high input R and C provide good response at lower  
frequencies but inappropriately load the circuit and distort signals at higher  
frequencies. The ZS Series features both high input R (1 MΩ) and low input C  
(0.6 pF and 0.9 pF) to reduce circuit loading across the entire probe/oscilloscope  
bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes. The ZS1500 is  
ideal for 1 GHz oscilloscopes, the ZS2500 is ideal for 2 GHz oscilloscopes, and the  
ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.  
Teledyne LeCroy  
Active Voltage Probe  
Model Numbers:  
ZS1000  
ZS1500  
ZS2500  
ZS4000  
PK-ZS-010  
Channel ID  
Colored Clips  
ZS4000  
PK-ZS-019  
Freehand Probe Holder  
PACC-PT005  
Bent Tip  
PACC-PT003  
IC Tip  
PK-ZS-001  
Probe Tip - Standard  
PK-ZS-017  
Pogo Tip  
PK-ZS-006  
Right Angle Socket  
PK-ZS-023  
Straight Pin  
Lead - 13cm  
PK-ZS-014  
Y-Lead  
Adapter  
PK-ZS-022  
Straight Pin  
Lead - 7cm  
PACC-LD003  
Right Angle  
Pin Lead - 5cm  
PACC-LD004  
Right Angle  
Pin Lead - 10cm  
PK-ZS-018  
2.54 mm Square  
Pin Adapter  
PK-ZS-020  
Pogo Ground Lead  
PK-ZS-016  
Offset Ground  
(Z Lead)  
PK-ZS-009  
Copper Tape  
PK-ZS-015  
Ground Blade - Wide  
PK-ZS-021  
Ground Blade -  
Narrow  
PK-ZS-024  
2.54 mm PCB  
Adapter  
PK-ZS-007R  
Microclip Sprung  
Hook, Red  
PK-ZF-025  
QFPIC Clip Yellow -  
Short  
PK-ZF-025  
QFPIC Clip Green -  
Short  
PK-ZS-007B  
Microclip Sprung  
Hook, Black  
12  
ZS SERIES ACTIVE PROBES  
ZS1000  
ZS1500  
ZS2500  
PK-ZS-010  
Channel ID  
Colored Clips  
PACC-MS005  
Freehand Probe Holderk  
PACC-PT005  
Bent Tip  
PACC-PT003  
IC Tip  
PK-ZS-001  
PK-ZS-013  
Pogo Tip  
Probe Tip  
-
Standard  
PK-ZS-006  
Right Angle Socket  
Qty:  
3
PK-ZS-012  
2.54 mm Square Pin  
Adapter  
PK-ZS-004  
Single Lead  
Long  
PK-ZS-005  
Y-Lead  
Adapter  
PK-ZS-003  
Single Lead  
Short  
PACC-LD003  
Right Angle  
Pin Lead - 5cm  
-
-
PACC-LD004  
Right Angle  
Lead - Long  
PACC-CD008  
Pogo Ground Lead  
PK-ZS-002  
Offset Ground  
PK-ZS-009  
Copper Tape  
PK-ZS-011  
Ground Blade Wide  
-
PK-ZS-008  
Ground Blade - Narrow  
PK-ZS-007R  
Microclip Sprung  
Hook, Red  
PK-ZS-007B  
Microclip Sprung  
Hook, Black  
Ordering Information  
Product Description  
ZS1000 ZS1500 ZS2500 ZS4000  
Specifications  
Product Code  
Electrical Characteristics  
4 GHz, 0.6 pF, 1 MΩ  
ZS4000  
Probe Bandwidth  
Input Capacitance  
DC Input Resistance  
Probe Offset Range  
Attenuation  
Input Dynamic Range  
Non-destruct Voltage  
1 GHz  
1.5 GHz  
0.9 pF  
2.5 GHz  
4 GHz  
0.6 pF  
High Impedance Active Probe  
2.5 GHz, 0.9 pF, 1 MΩ  
ZS2500  
ZS1500  
1 MΩ  
±12 V  
÷10  
High Impedance Active Probe  
N/A  
1.5 GHz, 0.9 pF, 1 MΩ  
High Impedance Active Probe  
±8 V  
20 V  
1 GHz, 0.9 pF, 1 MΩ  
ZS1000  
High Impedance Active Probe  
Set of 4 ZS2500, 2.5 GHz, 0.9 pF, 1 MΩ  
ZS2500-QUADPAK  
ZS1500-QUADPAK  
ZS1000-QUADPAK  
General Characteristics  
High Impedance Active Probes  
Cable Length  
1.3 m  
Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ  
High Impedance Active Probes  
Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ  
High Impedance Active Probes  
Standard Accessory/Quantity  
ZS1000  
ZS1000  
Replacement ZS1500  
Part Number ZS2500 ZS4000  
Replacement ZS1500  
Accessory Description  
2.54 mm PCB Adaptor  
2.54mm Square Pin Adapter  
2.54mm Square Pin Adaptor  
IC Tip  
Part Number ZS2500 ZS4000  
Accessory Description  
Offset Ground – Z Lead  
Pogo Ground Lead  
Pogo Ground Lead  
Pogo Tip  
PK-ZS-024  
PK-ZS-012  
PK-ZS-018  
PACC-PT003  
PACC-PT005  
5
PK-ZS-002  
PK-ZS-020  
PACC-CD008  
PK-ZS-017  
PK-ZS-013  
PK-ZS-001  
PK-ZS-025  
PACC-LD004  
PACC-LD003  
PK-ZS-006  
PK-ZS-023  
PK-ZS-004  
PK-ZS-022  
PK-ZS-003  
PK-ZS-005  
PK-ZS-014  
1
1
1
3
1
1
1
1
1
1
Bent Tip  
Pogo Tip  
1
3
Channel ID Clips  
Probe Tip – Standard  
QFPIC Clips (set of 2)  
Right Angle Lead – Long  
Right Angle Lead – Short  
Right Angle Socket  
Straight Pin Lead – Long  
Straight Pin Lead – Long  
Straight Pin Lead – Short  
Straight Pin Lead – Short  
Y Lead Adapter  
3
1
1
1
1
1
PK-ZS-010  
4
2
1
(Set of 4 colors)  
Copper Tape Pad  
PK-ZS-009  
PK-ZS-019  
PACC-MS005  
PK-ZS-008  
PK-ZS-011  
PK-ZS-021  
PK-ZS-015  
2
1
1
1
1
Freehand Probe Holder  
Freehand Probe Holder  
Ground Blade – Narrow  
Ground Blade – Wide  
Ground Blade, Narrow  
Ground Blade, Wide  
Micro-Grabber Pair  
1
1
1
1
1
2
1
1
1
PK-ZS-007R and  
1
2
2
PK-ZS-007B  
Y Lead Adaptor  
1
Offset Ground  
PK-ZS-016  
13  
CURRENT PROBES  
CURRENT PROBES  
Teledyne LeCroy current probes do not require the breaking of a  
circuit or the insertion of a shunt to make accurate and reliable  
current measurements. Based on a combination of Hall effect and  
transformer technology, Teledyne LeCroy current probes are ideal for  
making accurate AC, DC, and impulse current measurements.  
Teledyne LeCroy  
Current Probe  
and Adapter  
Model Numbers:  
Wide Range of Applications  
Teledyne LeCroy current probes are available in a variety of models for a  
wide range of applications. The full range of Teledyne LeCroy current probes  
includes models with bandwidths up to 100 MHz, peak currents up to  
700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often  
used in applications such as the design and test of switching power supplies,  
motor drives, electric vehicles, and uninterruptible power supplies.  
CP030  
CP030A  
CP031  
CP031A  
CP150  
CP500  
DCS025  
CA10  
High Sensitivity  
The CP030A and CP031A provide a high sensitivity of 1 mA/div. This  
allows for more precise low current measurements on Teledyne LeCroy  
oscilloscopes. When used with HDO high definition oscilloscopes with  
HD4096 technology, users will obtain highly accurate, low current waveforms  
with unmatched 12-bit resolution for improved debug and analysis.  
Fully Integrated  
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy  
®
ProBus connection and require no additional hardware. Along with providing  
power, the ProBus connection allows the current probe and oscilloscope to  
communicate, resulting in current waveforms automatically displayed on  
screen in Amps, and calculated power traces scaled correctly in Watts. This  
full integration also allows for Degauss and Autozero functions to be done  
directly from the oscilloscope’s user interface.  
Deskew Calibration Source  
The DCS015 deskew calibration source has both voltage and current time-  
aligned signals, which enables the precise deskew of voltage and current  
probes. Most voltage probes along with the CP030, CP030A, CP031, and  
CP031A are compatible with the DSC025.  
Opposite page:  
CP031, 30A, 100 MHz Current Probe.  
15  
CURRENT PROBES  
Key Features  
ProBus active probe interface withautomatic scaling in A/div  
Autozero and degauss capabilities built into instrument’s user interface  
Wide range of input currents and band
Teledyne LeCroy  
Current Probe  
and Adapter  
Model Numbers:  
CP030  
CP030  
30 Arms continuous current  
30 Arms continuous current  
50 Apeak current  
50 MHz bandwidth  
50 Apeak current  
50 MHz bandwidth  
1 mA/div sensitivity  
CP030A  
CP031  
CP031A  
CP150  
CP500  
DCS025  
CA10  
CP031  
30 Arms continuous current  
30 Arms continuous current  
50 Apeak current  
100 MHz bandwidth  
50 Apeak current  
100 MHz bandwidth  
1 mA/div sensitivity  
CP500  
CP150  
500 Arms continuous current  
150 Arms continuous current  
700 Apeak current  
2 MHz bandwidth  
500 Apeak current  
10 MHz bandwidth  
DCS025  
Precise deskew of voltage and  
current probes.  
Compatible with the CP030, CP030A,  
CP031, CP031A, AP015, CP150, and  
CP500  
16  
CURRENT PROBES  
CA10 Current Sensor Adapter  
The CA10 enables a third-party current measurement device to operate like a Teledyne  
LeCroy probe. The CA10 is programmable and customizable to work with third-party  
current measurement devices that output voltage or current signals proportional to  
measured current. (See page 50 for more information and specifications).  
CP030  
CP030A  
CP031  
CP031A  
CP150  
CP500  
Specifications  
(CP030-3M)  
(CP150-6M)  
Electrical Characteristics*  
Max. Continuous  
30 Arms  
150 Arms  
500 Arms  
2 MHz  
Input Current  
Bandwidth  
50 MHz  
10 MHz  
(5 MHz)  
100 MHz  
3.5 ns  
(10 MHz)  
Rise Time (typical)  
Max. Peak Current  
≤ 7 ns  
≤ 35 ns  
175 ns  
(≤ 35 ns)  
(≤ 70 ns)  
300 Apeak (non-continuous);  
500 Apeak ≤ 30 μs  
0.1 V/A & 1 V/A 0.01 V/A  
700 Apeak  
(non-continuous)  
50 Apeak (non-continuous)  
Output Voltage  
0.1 V/A  
0.1 V/A & 1 V/A  
5 A  
0.1 V/A  
Max Continuous Input Current  
5 A  
at 1 V/A (100mA/div or less)  
Offset Range at 1V/A  
(100mA/div or less)  
Minimum Sensitivity  
Low-Frequency Accuracy  
AC Noise at 20 MHz BWL  
Coupling  
±5 A  
±5 A  
10 mA/div  
1 mA/div  
10 mA/div  
1 mA/div  
1%  
150 µA  
AC, DC, GND  
100 mA/div  
2.5 mA  
150 µA  
2.5 mA  
6.0 mA  
8.0 mA  
General Characteristics  
Cable Length  
1.5 m  
(3 m)  
2 m  
1.5 m  
240 g  
6 m  
(6 m)  
Weight  
240 g  
500 g  
260 g  
260 g  
630 g  
(290 g)  
(600 g)  
Max. Conductor Size  
(Diameter)  
5 mm  
20 mm  
Interface  
ProBus, 1 MΩ only  
Usage Environment  
Operating Temperature  
Max. Relative Humidity  
Max. Altitude  
Measurement Category  
Indoor  
0˚ C to 40˚ C  
80%  
2000 m  
No rated measurement category**  
No rated measurement category**  
* Electrical Characteristics Guaranteed at 23 °C ±3 °C. Values are based on oscilloscopes with 1 mV/div sensitivity. Numbers will be higher on instruments with lower  
sensitivity.  
** Not intended for measurements on circuits directly connected to Mains supply or within Measurement Categories II, III, or IV.  
CP03x, CP150, and CP500 probes (and long cable versions of these) are compatible with any Teledyne LeCroy oscilloscope with a ProBus interface running  
firmware version 4.3.1.1 or greater. CP03xA probes are compatible with most Teledyne LeCroy oscilloscopes with a ProBus interface running X-Stream™  
firmware version 7.8.x.x or later.  
Ordering Information  
Product Description  
Product Code  
CA10  
CA10-QUADPAK  
CP030  
ProBus Current Sensor Adapter  
Set of 4 CA10, ProBus Current Sensor Adapters  
30 A; 50 MHz Current Probe – AC/DC; 30 A  
; 50 A Peak Pulse, 1.5 meter cable  
rms  
30A; 10 MHz Current Probe - AC/DC, 30 Arms; 50 A Peak Pulse, 3 meter cable (not EMC compliant)  
30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 A ; 50 A Peak Pulse, 1.5 meter cable  
CP030-3M  
CP030A  
rms  
30 A; 100 MHz Current Probe – AC/DC; 30 A  
; 50 A Peak Pulse, 1.5 meter cable  
CP031  
rms  
30 A; 100 MHz High Sensitivity Current Probe – AC/DC; 30 A  
; 50 A Peak Pulse, 1.5 meter cable  
rms  
CP031A  
150 A; 10 MHz Current Probe – AC/DC; 150 A  
; 500 A Peak Pulse, 2 meter cable  
CP150  
rms  
150 A; 5 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse, 6 meter cable (not EMC compliant)  
500 A; 2 MHz Current Probe – AC/DC; 500 A ; 700 A Peak Pulse, 6 meter cable  
CP150-6M  
CP500  
rms  
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500  
DCS025  
17  
DIFFERENTIAL PROBES  
DIFFERENTIAL PROBES  
Our differential probes are general purpose high-bandwidth probes with  
Teledyne LeCroy  
high dynamic range and offset. Wide variety of tips and leads are available,  
including solder-in, QuickLink solder-in, HiTemp solder-in, browser tip,  
square-pin, and SMA/SMP lead.  
Differential Probe  
Model Numbers:  
1.5 GHz  
ZD200  
ZD500  
ZD1000  
ZD1500  
AP033  
4 GHz - 6 GHz  
D410-A-PB2  
D420-A-PB2  
D400A-AT-PB2  
D610-A-PB2  
D610-A-PL  
D620-A-PB2  
D620-A-PL  
D600A-AT-PB2  
D600A-AT-PL  
8 GHz - 13 GHz  
D830-PB2  
D830-PL  
D1330-PL  
8 GHz - 30 GHz  
DH08-PB2  
DH08-PL  
DH13-PL  
DH16-PL  
DH20-PL  
DH25-2.92MM  
DH30-2.92MM  
Opposite page:  
DH Series Probes shown with HDA125.  
19  
1.5 GHz DIFFERENTIAL PROBES  
The ZD Series probes provide wide dynamic range, excellent noise and loading  
performance and an extensive set of probe tips, leads, and ground accessories  
to handle a wide range of probing scenarios. The low 1 pF capacitance means  
this probe is ideal for all frequencies. The ZD Series differential probes provide full  
system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower.  
Fully Integrated  
With the ProBus interface, the ZD500, 1000, and 1500 become an integral part  
of the oscilloscope. All probe gain and offset controls are transparent to the user,  
making it easier to probe the circuit without concern for which gain setting to  
choose. When used with a Teledyne LeCroy digital oscilloscope, no external power  
supply is required.  
Teledyne LeCroy  
1.5 GHz  
Differential Probe  
Model Numbers:  
Wide Dynamic Range  
The ZD500, 1000, 1500 probes provide transparent probe attenuation so signals are  
ZD200  
ZD500  
ZD1000  
ZD1500  
AP033  
always optimized for the display. The differential range is 18 V with a differential  
offset of ±8V and common mode range of ±10 V, making these probes versatile for  
every probing application.  
p-p  
Wide Applications  
The wide dynamic range of 16 V and offset range of ±8V suit this probe to a wide  
p-p  
range of applications and signal types. The ZD differential probes are ideally suited  
for Automotive, Serial Data, power, and general purpose use.  
ZD200  
ZD500  
ZD1000  
ZD1500  
Specifications  
Electrical Characteristics  
Bandwidth (Warranted)  
200 MHz  
500 MHz  
650 MHz  
650 ps  
1000 MHz  
1200 MHz  
375 ps  
280 ps  
2%  
1500 MHz  
1700 MHz  
270 ps  
-
Bandwidth (Typical)  
Risetime 10–90% (Typical)  
Risetime 20–80% (Typical)  
LF Attenuation Accuracy (Warranted)  
1.75 ns  
-
500 ps  
200 ps  
1%  
Zero Offset (Typical)  
5 mV  
-
-
(within 15 minutes after autozero)  
System Noise (Typical)  
1.3 mVrms  
1.75 mVrms  
Probe Noise Density (Typical)  
Input Differential Range (Nominal)  
Differential Offset Range (Nominal)  
Offset Gain Accuracy (Typical)  
Common Mode Range (Nominal)  
3 mV  
38 nV/rt (Hz)  
±8 V (16 Vp-p)  
±18 V  
rms  
± 20 V  
-
-
2%  
±10 V  
± 60 V  
Maximum Non-destruct Voltage  
30 V  
-
(Nominal)  
CMRR (Typical)  
80 dB @ 60 Hz  
50 dB@10 MHz  
60 dB 50/60 Hz  
30 dB 20 MHz  
25 dB 500 MHz  
60 dB 50/60 Hz  
30 dB 20 MHz  
60 dB 50/60 Hz  
30 dB 20 MHz  
25 dB @ 1000 MHz  
25 dB @ 1500 MHz  
DC Input Resistance (Nominal)  
250 kΩ (Common Mode)  
1 MΩ (Differential Mode)  
50 kΩ (Common Mode)  
120 kΩ (Differential Mode)  
Differential Input Capacitance  
(Typical)  
3.5 pF  
< 1.0 pF  
20  
1.5 GHz DIFFERENTIAL PROBES  
Ordering Information  
Product Description  
Product Code  
200 MHz, 3.5 pF, 1 MΩ Active Differential Probe  
500 MHz, 1.0 pF Active Differential Probe, ±8 V  
1 GHz, 1.0 pF Active Differential Probe, ±8 V  
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V  
ZD200  
ZD1500 / ZD1000 / ZD500 Probe  
ZD500  
ZD1000  
ZD1500  
PCF200  
Probe Calibration Fixture  
PACC-MS001  
Hands Free Probe Holder  
PACC-ZD004  
Tip Saver  
Qty: 2  
PACC-PT001  
Straight Tip  
Qty: 4  
PACC-ZD005  
Swivel Tip Adapter  
PACC-ZD006  
Small IC Adapter  
Qty: 2  
PACC-CD008  
Spring-loaded  
Ground (Short)  
Qty: 2  
PACC-ZD003  
Spring-loaded  
Ground (Long)  
Qty: 2  
PK006-4  
Micro-Grabber  
Qty: 2  
PACC-CL001  
Mini-Grabber  
Qty: 2  
PACC-LD003  
Right Angle  
Connector (Short)  
Qty: 2  
PACC-ZD001  
Y Lead  
Adapter  
PACC-ZD002  
Solder-In-Lead  
Qty: 2  
PACC-LD004  
Right Angle  
Connector (long)  
Qty: 2  
AP033  
Specifications  
Bandwidth  
Gain  
High bandwidth, excellent common-mode rejection ratio  
(CMRR) and low noise make these active differential  
probes ideal for applications such as disk drive design  
and failure analysis, as well as wireless and data  
communication design.  
500 MHz  
x10, x1, ÷10 (÷100 with  
plug-on ÷10 attenuator)  
DC Accuracy  
1% in x1 without  
external attenuator  
Input Resistance  
1 MΩ each input to ground  
2 MΩ differential between inputs  
Differential Mode Range  
±400 mV (x1)  
±40 mV (x10)  
±4 V (÷10)  
±40 V (÷100)  
Offset Range  
±400 mV (x1, x10)  
±4 V (±10)  
±40 V (±100)  
Common-Mode Range  
CMRR  
±42 V peak (±10)  
+4.2 V peak (±100)  
70 Hz 10,000:1 (80 dB)  
100 kHz 10,000:1 (80 dB)  
1 MHz 1000:1 (60 dB)  
10 MHz 100:1 (40 dB)  
250 MHz 5:1 (14 dB)  
Ordering Information  
Product Description  
500 MHz Differential Probe  
Product Code  
AP033  
21  
4 GHz - 6 GHz DIFFERENTIAL PROBES  
Teledyne LeCroy’s WaveLink 4-6 GHz Differential Probes are a general purpose  
probing solution with high-input dynamic range and offset range capability. The  
range of capabilities is ideal for a variety of high-speed DDR signals where high  
dynamic range and large offset requirements are common.  
Key Features  
4 GHz or 6 GHz models  
Up to 5 Vpk-pk dynamic range with low noise  
±3 V offset range  
Teledyne LeCroy  
4 GHz - 6 GHz  
Differential Probe  
Model Numbers:  
Ideal for DDR2, LPDDR2, DDR3  
Innovative QuickLink architecture  
Wide variety of tips and leads  
– Solder-In Lead  
– QuickLink Solder-In Lead  
– Positioner (Browser) Tip  
– Adjustable (Browser) Tip  
D410-A-PB2  
D420-A-PB2  
D400A-AT-PB2  
D610-A-PB2  
D610-A-PL  
D620-A-PB2  
D620-A-PL  
– Quick Connect Lead  
– Square Pin Lead  
– Hi-Temp Solder-In Lead  
Low loading and high impedance for minimal signal disturbance  
Deluxe soft carrying case  
D600A-AT-PB2  
D600A-AT-PL  
22  
4 GHz - 6 GHz DIFFERENTIAL PROBES  
D610-A-PB2,  
D610-A-PL  
D620-A-PB2,  
D620-A-PL  
D410-A-PB2  
D420-A-PB2  
D600A-AT-PB2, D400A-AT-PB2  
D600A-AT-PL  
Bandwidth*  
Dx10-SI, Dx10-QL-SI  
and Dx10-PT Tips  
6 GHz  
Dx20-SI, Dx20-QL-SI  
and Dx20-PT Tips  
6 GHz  
Dx10-SI, Dx10-QL-SI,  
Dx10-HiTemp, Dx10-QC  
and Dx10-PT Tips  
4 GHz  
Dx20-SI, Dx20-QL-SI,  
Dx20-HiTemp, Dx20-QC  
and Dx20-PT Tips  
4 GHz  
6 GHz  
4 GHz  
(Probe only, guaranteed)  
(System bandwidth, typical)  
Dx10-HiTemp  
Dx20-HiTemp  
5 GHz  
5 GHz  
Dx10-SP Tip  
Dx20-SP Tip  
3 GHz  
3 GHz  
Dx10-QC Tip  
Dx20-QC Tip  
4 GHz  
4 GHz  
Dx10-SP Tip  
Dx20-SP Tip  
3 GHz  
3 GHz  
Rise Time* (10–90%)  
Dx10-SI, Dx10-QL-SI  
and Dx10-PT Tips  
75 ps (typical)  
Dx20-SI, Dx20-QL-SI  
and Dx20-PT Tips  
75 ps (typical)  
Dx10-SI, Dx10-QL-SI,  
Dx10-HiTemp,  
Dx20-SI, Dx20-QL-SI,  
Dx20-HiTemp,  
<75 ps (typical)  
56 ps (typical)  
<74 nV/√Hz  
<112 ps (typical)  
84 ps (typical)  
<74 nV/√Hz  
and Dx10-PT Tips  
112 ps (typical)  
and Dx20-PT Tips  
112 ps (typical)  
Dx10-HiTemp  
Dx20-HiTemp  
90 ps (typical)  
90 ps (typical)  
Dx10-QC Tip  
Dx20-QC Tip  
122.5 ps (typical)  
122.5 ps (typical)  
Dx10-QC Tip  
Dx20-QC Tip  
122.5 ps (typical)  
122.5 ps (typical)  
Dx10-SP Tip  
Dx20-SP Tip  
150 ps (typical)  
150 ps (typical)  
Dx10-SP Tip  
Dx20-SP Tip  
150 ps (typical)  
150 ps (typical)  
Rise Time* (20–80%)  
Dx10-SI, Dx10-QL-SI  
and Dx10-PT Tips  
56 ps (typical)  
Dx20-SI, Dx20-QL-SI  
and Dx20-PT Tips  
56 ps (typical)  
Dx10-SI, Dx10-QL-SI,  
Dx10-HiTemp,  
Dx20-SI, Dx20-QL-SI,  
Dx20-HiTemp,  
and Dx10-PT Tips  
84 ps (typical)  
and Dx20-PT Tips  
84 ps (typical)  
Dx10-HiTemp  
Dx20-HiTemp  
67.5 ps (typical)  
67.5 ps (typical)  
Dx10-QC Tip  
Dx20-QC Tip  
92 ps (typical)  
92 ps (typical)  
Dx10-QC Tip  
Dx20-QC Tip  
92 ps (typical)  
92 ps (typical)  
Dx10-SP Tip  
Dx20-SP Tip  
113 ps (typical)  
113 ps (typical)  
Dx10-SP Tip  
Dx20-SP Tip  
113 ps (typical)  
113 ps (typical)  
Noise (System)  
<36 nV/√Hz  
<61 nV/√Hz  
<36 nV/√Hz  
<67 nV/√Hz  
(2.8 mV ) (typical)  
rms  
(4.8 mV ) (typical)  
rms  
(2.3 mV ) (typical)  
rms  
(4.3 mV ) (typical)  
rms  
(5.8 mV ) (typical) (4.7 mV ) (typical)  
rms rms  
Referred to input,  
6 GHz bandwidth  
Referred to input,  
6 GHz bandwidth  
Referred to input,  
4 GHz bandwidth  
Referred to input,  
4 GHz bandwidth  
Referred to input,  
Referred to input,  
6 GHz bandwidth  
4 GHz bandwidth  
Input  
Input Dynamic Range  
(Nominal)  
2.5V , ±1.25V  
pk-pk  
5V  
, ±2.5V  
pk-pk  
2.5V  
, ±1.25V  
pk-pk  
5V  
, ±2.5V  
pk-pk  
4.8V , ±2.4V  
pk-pk  
Input Common Mode Voltage  
±4 V  
±2.4 Vmax  
n/a  
Range (Nominal)  
Input Offset Voltage Range  
Non-destructive  
Input Range (Nominal)  
Attenuation  
DC Input Resistance  
(Nominal)  
±3 V Differential (nominal)  
±20 V  
±18 V  
1.7X / 1.0X (nominal)  
3.2X / 1.9X (nominal)  
200 kΩ Differential  
50 kΩ Common Mode  
1.7X / 1.0X (nominal)  
3.2X / 1.9X (nominal)  
2.5X  
4 kΩ Differential  
1 kΩ Common Mode  
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth  
Through entire frequency range  
Product Description  
Product Code Product Description  
Accessories  
Product Code  
Complete Differential Probes  
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),  
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)  
4 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),  
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)  
4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),  
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)  
4 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),  
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)  
6 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),  
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)  
6 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),  
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)  
6 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),  
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)  
6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),  
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)  
4 GHz ProBus2 Differential Probe with Adjustable Tip  
D410-A-PB2 Probe Deskew and Calibration Test Fixture  
TF-DSQ  
D410-A-PL  
Calibration Options  
NIST Calibration for D410-A. Includes test data.  
D410-A-CCNIST  
D420-A-CCNIST  
D610-A-CCNIST  
D620-A-CCNIST  
D400A-AT-CCNIST  
D600A-AT-CCNIST  
D420-A-PB2  
NIST Calibration for D420-A. Includes test data.  
NIST Calibration for D610-A. Includes test data.  
NIST Calibration for D620-A. Includes test data.  
D420-A-PL  
NIST Calibration for D400A-AT. Includes test data.  
NIST Calibration for D600A-AT. Includes test data.  
D610-A-PB2  
D610-A-PL  
Replacement Parts  
Single replacement QuickLink Solder-In Tip  
9-pack of replacement QuickLink Solder-In Tip  
Replacement Dx10-SI 4 & 6 GHz Solder-In Lead with  
Qty. 5 Spare Resistors.  
QL-SI-1Pack  
QL-SI-9Pack  
Dx10-SI  
D620-A-PB2  
D620-A-PL  
Replacement Dx20-SI 4 & 6 GHz Solder-In Lead with  
Dx20-SI  
D400A-AT-PB2  
D600A-AT-PB2  
D600A-AT-PL  
Qty. 5 Spare Resistors.  
6 GHz ProBus2 Differential Probe with Adjustable Tip  
6 GHz ProLink Differential Probe with Adjustable Tip  
Replacement Dx10-QC 4 & 6 GHz Quick Connect Lead  
Replacement Dx20-QC 4 & 6 GHz Quick Connect Lead  
Replacement Dx10-SP 4 & 6 GHz Square Pin Lead  
Replacement Dx20-SP 4 & 6 GHz Square Pin Lead  
Replacement SI Resistor Kit for Dx10/Dx20 - Kit of 20  
Replacement QC Resistor Kit for Dx10/Dx20 - 2 kits of 20  
Qty. 4 Replacement Pogo Pin Tips and Qty. 2  
Replacement Sockets for Dx10-PT and  
Dx10-QC  
Dx20-QC  
Dx10-SP  
Dx20-SP  
PKxx0-SI  
Positioner Tip (Browser) Kits  
WaveLink Dx10-PT Adjustable Positioner Tip Kit.  
For use with Dx10 amplifiers.  
WaveLink Dx20-PT Adjustable Positioner Tip Kit.  
For use with Dx20 amplifiers.  
Dx10-PT-KIT  
Dx20-PT-KIT  
PKxx0-QC  
Dxx0-PT-TIPS  
Dx20-PT Adjustable Positioner Tips.  
QuickLink Solder-In Tip Set  
Replacement Probe Tip Holder Kit  
PK600ST-3  
PK600ST-4  
Dxx0-PT-TAPE  
QuickLink Solder-In starter pack for use with Dx10 amplifier.  
Dx10-QL-3SI  
Dx20-QL-3SI  
Replacement Platform/Cable Assembly Mounting Kit  
Quantity 1 Package of Black Adhesive Pads (10/pkg) and  
Quantity 1 Package of White Adhesive Pads (10/pkg)  
Quantity 1 Package of Adhesive Probe Connection Guides  
(200 individual guides/package)  
Includes one QuickLink adapter and three QL-SI tips.  
QuickLink Solder-In starter pack for use with Dx20 amplifier.  
Includes one QuickLink adapter and three QL-SI tips.  
Dxx0-PT-GUIDES  
23  
8 GHz - 13 GHz DIFFERENTIAL PROBES  
The WaveLink Differential Probe Series is a 8-13 GHz bandwidth active differential  
probe series with high input dynamic range, a large offset capability, and a wide  
variety of tips and leads available for different applications.  
Key Features  
Choice of 8 or 13 GHz bandwidth models  
3.5 Vpk-pk dynamic range  
±4 V offset range  
Ideal for DDR3, DDR4, LPDDR3  
Innovative QuickLink architecture  
Teledyne LeCroy  
8 GHz - 13 GHz  
Differential Probe  
Model Numbers:  
Wide variety of tips and leads  
– Solder-In Lead  
– QuickLink Solder-In Lead  
– Positioner (Browser) Tip  
– SMA/SMP Lead  
– Square Pin Lead  
– Hi-Temp Solder-In Lead  
D830-PB2  
D830-PL  
D1330-PL  
Low loading and high impedance for minimal signal disturbance  
Deluxe soft carrying case  
SMA/SMP lead set accessory does not require purchase of a different amplifier  
24  
8 GHz - 13 GHz DIFFERENTIAL PROBES  
D830-PB2, D830-PL  
D1330-PL  
Dxx30-SI and Dxx30-SMA-SMP Tips  
13 GHz  
Bandwidth*  
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,  
Dxx30-HiTemp, and Dxx30-PT Tips  
8 GHz  
(Probe only, guaranteed)  
(System bandwidth, typical)  
Dxx30-PT and Dxx30-HiTemp Tips  
Dxx30-SP Tip  
10 GHz  
3 GHz  
Dxx30-QL-SI Tip  
8 GHz  
Dxx30-SP Tip  
3 GHz  
Rise Time* (10–90%)  
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,  
Dxx30-HiTemp, and Dxx30-PT Tips  
50 ps (typical)  
Dxx30-SI and Dxx30-SMA-SMP Tips  
35 ps (typical)  
Dxx30-PT and Dxx30-HiTemp Tips  
Dxx30-SP Tip  
132 ps (typical)  
40 ps (typical)  
Dxx30-QL-SI Tip  
50 ps (typical)  
Dxx30-SP Tip  
132 ps (typical)  
Rise Time* (20–80%)  
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,  
Dxx30-HiTemp, and Dxx30-PT Tips  
37.5 ps (typical)  
Dxx30-SI and Dxx30-SMA-SMP Tips  
26 ps (typical)  
Dxx30-PT and Dxx30-HiTemp Tips  
Dxx30-SP Tip  
100 ps (typical)  
30 ps (typical)  
Dxx30-QL-SI Tip  
37.5 ps (typical)  
Dxx30-SP Tip  
100 ps (typical)  
Noise (Probe)  
<48 nV/Hz (4.3 mVrms) (typical)  
Referred to input, 8 GHz bandwidth.  
<52 nV/Hz (4.6 mVrms) (typical)  
Referred to input, 8 GHz bandwidth.  
<48 nV/Hz (5.5 mVrms) (typical)  
Referred to input, 13 GHz bandwidth.  
<52nV/Hz (5.9 mVrms) (typical)  
Referred to input, 13 GHz bandwidth.  
Noise (System)  
Input  
Input Dynamic Range  
Input Common Mode Voltage Range  
Input Offset Voltage Range  
Non-destructive Input Range  
Attenuation  
3.5Vpk-pk, ±1.75V (nominal)  
±5 V (nominal)  
±4 V Differential (nominal)  
±15 V (nominal)  
3.75x (nominal)  
DC Input Resistance (nominal)  
200 kΩ Differential  
50 kΩ Common mode  
>250 Ω Differential through entire frequency range using SI tip  
Impedance (Zmin, typical)  
Impedance (mid-band, typical)  
Dxx30-SI, Dxx30-QL-SI, and Dxx30-HiTemp Tips  
470 Ω at 4 GHz, 320 Ω at 6 GHz, 260 Ω at 8 GHz, 250 Ω at 9 GHz, 260 Ω at 10 GHz, 350 Ω at 13 GHz  
Dxx30-PT Tip  
155 Ω at 4 GHz, 210 Ω at 6 GHz, 140 Ω at 8 GHz, 80 Ω at 9 GHz, 40 Ω at 10 GHz  
CMRR  
58 dB DC / 100 Hz  
38 dB to 10 MHz  
30 dB to 3 GHz  
20 dB to 8 GHz  
(typical)  
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth  
Product Description  
Product Code  
Product Description  
Product Code  
Complete Differential Probes  
Accessories  
8 GHz ProBus2 Differential Probe with Dxx30-SI Solder-In Tip  
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)  
8 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip  
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)  
13 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip  
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)  
D830-PB2  
D830-PL  
Probe Deskew and Calibration Test Fixture  
Calibration Options  
NIST Calibration for D830. Includes test data.  
NIST Calibration for D1330. Includes test data.  
TF-DSQ  
D830-CCNIST  
D1330-CCNIST  
D1330-PL  
Replacement Parts  
Single replacement QuickLink Solder-In Tip  
9-pack of replacement QuickLink Solder-In Tip  
Replacement Dxx30-SP 8-13 GHz Square Pin Lead  
Replacement Dxx30-SI 8-13 GHz Solder-In Lead  
with Qty. 5 Spare Resistors.  
QL-SI-1Pack  
QL-SI-9Pack  
Dxx30-SP  
Positioner Tip (Browser) Kits  
WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable  
Positioner Tip Kit. For use with Dxx30 amplifiers.  
Dxx30-PT-KIT  
Dxx30-SI  
Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI  
Dxx05-SI-RESISTORS  
Dxx0-PT-TIPS  
QuickLink Solder-In Tip Set  
and Dxx30-SI Solder-In Tip - Kit of 5  
QuickLink Solder-In starter pack for use with Dxx30 amplifier.  
Dxx30-QL-3SI  
Dxx30-HiTemp  
Includes one QuickLink adapter and three QL-SI tips.  
Qty. 4 Replacement Pogo Pin Tips and  
Qty. 2 Replacement Sockets for Dx10-PT, Dx20-PT,  
and Dxx30-PT Adjustable Positioner Tips.  
Replacement Probe Tip Holder Kit  
Hi-Temp Lead Set  
WaveLink Temperature Extension Cables for Dxx30.  
Includes set of Matched 30” High Temperature Cables (Qty. 1)  
and solder-in lead set (Qty. 1).  
PK600ST-3  
PK600ST-4  
Dxx0-PT-TAPE  
Replacement Platform/Cable Assembly Mounting Kit  
Quantity 1 Package of Black Adhesive Pads (10/pkg) and  
Quantity 1 Package of White Adhesive Pads (10/pkg)  
Quantity 1 Package of Adhesive Probe Connection Guides  
(200 individual guides/package)  
Dxx05-PT-GUIDES  
SMA/SMP Lead Set  
SMA/SMP lead set for use with Dxx30 amplifiers.  
Includes a set of SMA leads, SMP leads, pair of DC blocks  
and SMA finger wrenches.  
Dxx30-SMA-SMP-LEADS  
25  
8 GHz - 30 GHz DIFFERENTIAL PROBES  
The DH series of 8 to 30 GHz active differential probes provides high input  
dynamic range, large offset capability, low loading and excellent signal  
fidelity with a range of connection options.  
Key Features  
Bandwidth models from 8 GHz to 30 GHz  
Low loading and high impedance for minimal signal disturbance  
Wide variety of tips:  
– Standard and high-sensitivity 30 GHz solder-in tips  
– High-temperature solder-in tip with 1-meter lead  
– QuickLink adapter for mixed-signal probing  
– Handheld browser tip  
Teledyne LeCroy  
8 GHz - 30 GHz  
Differential Probe  
Model Numbers:  
Built-in tip identification for simple setup and precise signal reproduction  
DH08-PB2  
DH08-PL  
Ideal for debug and validation of:  
DH13-PL  
– DDR3/LPDDR3  
– DDR4/LPDDR4  
– DDR5/LPDDR5  
DH16-PL  
DH20-PL  
DH25-2.92MM  
DH30-2.92MM  
– Other high-speed serial interfaces  
LabMaster 10 Zi-A Oscilloscope  
WaveMaster/SDA 8 Zi-B Oscilloscope  
WavePro HD Oscillosope  
LabMaster MCMZi-A Master Control Module  
1
2
3
4
LPA-PB2  
LPA-2.92MM  
DH08-PL  
DH25-2.92MM  
DH30-2.92MM  
DH13-PL  
DH16-PL  
DH20-PL  
DH08-PB2  
DH-SI-HS  
DH-SI  
DH-PT  
DH-HITEMP  
DH-QL  
26  
8 GHz - 30 GHz DIFFERENTIAL PROBES  
DH08  
DH13  
DH16  
DH20  
DH25  
DH30  
Bandwidth  
Bandwidth (probe only)  
8 GHz  
8 GHz  
8 GHz  
8 GHz  
8 GHz  
13 GHz  
13 GHz  
13 GHz  
13 GHz  
8 GHz  
16 GHz  
16 GHz  
16 GHz  
16 GHz  
8 GHz  
20 GHz  
20 GHz  
16 GHz  
16 GHz  
8 GHz  
25 GHz  
25 GHz  
16 GHz  
16 GHz  
8 GHz  
30 GHz  
30 GHz  
16 GHz  
16 GHz  
8 GHz  
Bandwidth with DH-SI or DH-SI-HS tip  
Bandwidth with DH-HITEMP tip  
Bandwidth with DH-PT browser  
Bandwidth with DH-QL adapter and  
QL-SI tip  
Rise Time*  
Rise Time (10-90%)  
Rise Time (20-80%)  
Probe noise (referred to input)*  
With DH-SI-HS tip  
56 ps  
37.5 ps  
34.5 ps  
23 ps  
28 ps  
19 ps  
22.5 ps  
15 ps  
18 ps  
12 ps  
15 ps  
10 ps  
2.1 mV  
3.5 mV  
2.2 mV  
3.8 mV  
2.3 mV  
4.2 mV  
2.6 mV  
4.6 mV  
2.9 mV  
4.8 mV  
3.2 mV  
5.0 mV  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
rms  
With all other tips  
Probe noise density (referred to input)  
With DH-SI-HS tip  
18 nV/rt(Hz)  
With all other tips  
30 nV/rt(Hz)  
Input  
Input Dynamic Range  
With DH-SI-HS tip  
2.0 Vpp (±1.0 V)  
With all other tips  
3.5 Vpp (±1.75 V)  
±5.0 V  
Input Common Mode Voltage Range  
Input Offset Voltage Range  
Non-destructive Input Range  
Attenuation  
±4.0 V  
±16 V  
With DH-SI-HS tip  
With all other tips  
Attenuation Accuracy  
DC Input Resistance (nominal)  
Differential  
1.8x / 3.2x (selected automatically by oscilloscope software)  
3.2x / 5.8x (selected automatically by oscilloscope software)  
±2%  
200 kΩ differential  
50 kΩ differential  
Common mode  
Input Resistance > 10 kHz (typical)  
With DH-SI-HS tip  
With all other tips  
1100 Ω differential  
2100 Ω differential  
Environmental  
Temperature  
Non-operating  
Operating (DH-HITEMP tip)  
-40 °C to 70 °C  
-40 °C to 125 °C  
* All Rise Time and Probe noise measurements are made using a full-bandwidth solder-in tip, and with an oscilloscope bandwidth greater than or equal to the probe bandwidth. When using other tips, rise time  
and noise measurements correspond to those of the equivalent-bandwidth probe model with a DH-SI tip.  
Product Description  
Product Code  
Product Description  
Calibration Options  
3-year warranty  
Product Code  
Differential Probes (tips not included)  
8 GHz differential probe with ProBus2 interface  
8 GHz differential probe with ProLink interface  
13 GHz differential probe with ProLink interface  
16 GHz differential probe with ProLink interface  
20 GHz differential probe with ProLink interface  
25 GHz differential probe with 2.92 mm interface  
30 GHz differential probe with 2.92 mm interface  
DH08-PB2  
DH08-PL  
DH08-W3, DH13-W3,  
DH16-W3, DH20-W3,  
DH25-W3, DH30-W3  
DH08-W5, DH13-W5,  
DH16-W5, DH20-W5,  
DH25-W5, DH30-W5  
DH08-C3, DH13-C3,  
DH16-C3, DH20-C3,  
DH25-C3, DH30-C3  
DH08-C5, DH13-C5,  
DH16-C5, DH20-C5,  
DH25-C5, DH30-C5  
DH08-T3, DH13-T3,  
DH16-T3, DH20-T3,  
DH25-T3, DH30-T3  
DH08-T5, DH13-T5,  
DH16-T5, DH20-T5,  
DH25-T5, DH30-T5  
DH13-PL  
5-year warranty  
DH16-PL  
DH20-PL  
DH25-2.92MM  
DH30-2.92MM  
3-year annual NIST calibration  
Solder-in Tips  
5-year annual NIST calibration  
DH series solder-in tip, 30 GHz BW, 3.5 Vpp range  
DH-SI  
DH-SI-HS  
DH series high-sensitivity solder-in tip, 30 GHz BW,  
2.0 Vpp range  
3-year warranty with annual NIST calibration  
5-year warranty with annual NIST calibration  
NIST traceable calibration with test data  
Positioner (Browser) Tips  
DH series PT browser tip, 16 GHz BW, 3.5 Vpp range  
DH-PT  
High-temperature Tips  
DH08-CCNIST,  
DH13-CCNIST,  
DH16-CCNIST,  
DH20-CCNIST,  
DH25-CCNIST,  
DH30-CCNIST  
DH series high-temperature solder-in tip, 16 GHz BW,  
DH-HITEMP  
3.5 Vpp range  
QuickLink Adapters and Kits  
DH series QuickLink adapter, 8 GHz BW  
DH series QuickLink adapter kit with 3 x QL-SI tips  
DH-QL  
DH-QL-3SI  
Accessories  
Replacement Parts  
ProLink to 2.92 mm adapter with probe power and  
LPA-2.92  
Replacement SI resistor kit for DH-SI and  
DH-SI-RESISTORS  
communication pass through  
DH-SI-HS solder-in tips  
2.92 mm to ProLink adapter with probe power and  
communication pass through  
L2.92A-PLINK  
27  
HIGH VOLTAGE DIFFERENTIAL PROBES  
HIGH VOLTAGE DIFFERENTIAL PROBES  
High voltage differential probes provide high CMRR over a broad frequency  
Teledyne LeCroy  
High Voltage  
range to simplify the measurement challenges found in noisy, high common-  
mode power electronics environments. The probe’s design is easy-to-use  
and enables safe, precise high voltage floating measurements.  
Differential Probe  
Model Numbers:  
HVD3102A  
HVD3106A  
HVD3106A-6M  
HVD3206A  
HVD3206A-6M  
HVD3220  
HVD3605A  
AP031  
Opposite page:  
HVD3000A Series High Voltage Differential Probes  
with a WaveRunner 8000HD High Definition Oscilloscope.  
29  
HIGH VOLTAGE DIFFERENTIAL PROBES  
Teledyne LeCroy  
High Voltage  
Differential Probe  
Model Numbers:  
HVD3102A  
HVD3106A  
HVD3106A-6M  
HVD3206A  
HVD3206A-6M  
HVD3220  
HVD3605A  
The HVD3000A series high voltage differential probes provide high CMRR over a  
broad frequency range to simplify the measurement challenges found in noisy, high  
common-mode power electronics environments. The probe’s design is easy-to-use  
and enables safe, precise high voltage floating measurements.  
Key Features  
1 kV, 2 kV, 6 kV CAT safety rated models  
Widest differential voltage ranges available  
Exceptional common-mode rejection ratio (CMRR)  
across a broad frequency range  
1% gain accuracy  
High offset capability at both high and low attenuation  
AC and DC coupling  
ProBus active probe interface with automatic scaling  
AutoZero with auto disconnect switch  
Wide oscilloscope compatibility  
30  
HIGH VOLTAGE DIFFERENTIAL PROBES  
HVD3106A/  
HVD3206A/  
HVD3102A  
25 MHz  
HVD3106A-6M  
HVD3206A-6M  
HVD3220  
400 MHz  
HVD3605A  
100 MHz  
120 MHz/  
80 MHz  
120 MHz/  
80 MHz  
Bandwidth  
1500 V  
1500 V  
2000 V  
7000 V  
(DC + peak AC)  
(7600 V maximum  
typical measurable  
before saturation)  
8485 V (DC + peak AC)  
CAT I  
Differential  
Voltage  
(DC + peak AC)  
(DC + peak AC)  
(DC + peak AC)  
(1750V maximum  
typical measurable  
before saturation)  
(2000V maximum typical  
measurable before saturation)  
Range  
1000 V  
CAT III  
rms  
2000 V (DC + peak AC) CAT I  
1500 Vdc CAT III  
Max Safe  
Input  
1000 Vrms CAT III  
6000 V  
CAT I  
rms  
Voltage  
1000 V  
CAT III  
rms  
1000 V CAT III  
dc  
Gain  
1%*  
2.25 meters/  
6.8 meters  
Accuracy  
2.25 meters  
2.25 meters/  
6.8 meters  
2 meters  
6.8 meters  
Cable Length  
Included Tip  
Accessories  
*Up to 0.35% on HVD3220  
Yes  
HVD310xA-NOACC  
HVD310xA / 310xA-6M  
HVD3206A / 3206A-6M  
HVD3220  
HVD3605A  
31  
HIGH VOLTAGE DIFFERENTIAL PROBES  
Teledyne LeCroy  
High Voltage  
Differential Probe  
Model Numbers:  
HVD3102A  
HVD3106A  
HVD3106A-6M  
HVD3206A  
HVD3206A-6M  
HVD3220  
HVD3605A  
AP031  
Ordering Information  
Product Description  
Product Code  
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable  
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable  
1 kV, 80 MHz High Voltage Differential Probe with 6 m cable  
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories  
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories  
2 kV, 120 MHz High Voltage Differential Probe with 2 m cable  
2 kV, 80 MHz High Voltage Differential Probe with 6 m cable  
HVD3102A  
HVD3106A  
HVD3106A-6M  
HVD3102A-NOACC  
HVD3106A-NOACC  
HVD3206A  
HVD3206A-6M  
HVD3220  
2 kV, 400 MHz High Voltage Differential Probe with 2 m cable  
6 k 100 MHz High Voltage Differential Probe with 6 m cable  
HVD3605A  
PK-HV-001  
V,  
High Voltage Replacement Accessories Kit (Includes 2 each): High Bandwidth 4 mm Probe Tip Adapters,  
Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals  
32  
HIGH VOLTAGE DIFFERENTIAL PROBES  
AP031  
The AP031 is a low cost, battery operated active  
differential probe intended for measuring higher  
voltages. The differential techniques employed  
permit measurements to be taken at two points in a  
circuit without reference to the ground, allowing the  
oscilloscope to be safely grounded without the use  
of opto-isolators or isolating transformers.  
Key Features  
Safe floating measurements  
15 MHz bandwidth  
700 V maximum input voltage  
Works with any 1 MΩ input oscilloscope  
Specifications  
Attenuation  
÷10 / ÷100  
Bandwidth  
15 MHz  
Input R  
4 MΩ  
Differential Mode Range  
Common Mode Range  
CMRR  
±70 V / ±700 V DC + Peak AC  
±700 V DC + Peak AC  
86 dB @ 50 Hz  
56 dB @ 200 kHz  
Power Requirements: four AA batteries  
Ordering Information  
Product Description  
Product Code  
700 V, 15 MHz Differential Probe (÷10, ÷100)  
AP031  
33  
HIGH VOLTAGE PROBES  
HIGH VOLTAGE PROBES  
High voltage probes are suitable for a wide range of applications where  
high-voltage measurements must be made safely and accurately. There  
are several fixed attenuation probes covering a range from 1 kV to 6 kV  
and varying transient overvoltage ratings. All of these high voltage probes  
feature a spring loaded probe tip and a variety of standard accessories  
to make probing high voltages safe and easy. Additionally, all of the high  
voltage probe have a probe sense pin to automatically configure the  
oscilloscope for use with the probe.  
Teledyne LeCroy  
High Voltage Probe  
Model Numbers:  
HVP120  
PPE4KV  
PPE5KV  
PPE6KV  
Opposite page:  
PPE Series High Voltage Probe with a WaveSurfer 4000HD  
High Definition Oscilloscope.  
35  
HIGH VOLTAGE PROBES  
The HVP120 is a high voltage passive probe designed for probing up to  
1,000 Vrms and capable of handling up to 6,000 V peak transients. Its  
fast rise time and excellent frequency response make it suitable for a wide  
variety of high voltage measurement applications. The HVP120 features  
a spring loaded probe tip and a variety of standard accessories to make  
probing high voltages safe and easy.  
Electrical Characteristics  
Bandwidth  
400 MHz  
Risetime (10% - 90%)  
Maximum Input Voltage*  
Measurement Category II  
Measurement Category I  
900 ps (typical)  
1000 Vrms  
4000V Transient Overvoltage at 1000 Vrms  
6000V Transient Overvoltage at 0 Vrms  
Teledyne LeCroy  
High Voltage Probe  
Model Number:  
Pollution Degree*  
Input Capacitance  
Compensation Range  
Attenuation Ratio  
2
7.5 pF (typical)  
10 pF - 50 pF (typical)  
100:1 ± 2%  
HVP120  
Environmental  
Temperature (Operating)  
Temperature (Non-Operating)  
Humidity (Operating)  
0°C to 50°C  
-40°C to 71°C  
80% RH (Non-Condensing) up to 31°C,  
decreasing linearly to 40% RH at 50°C  
Altitude (Operating)  
Altitude (Non-Operating)  
up to 2,000 m  
up to 15,000 m  
General Characteristics  
Weight (probe)  
Cable Length  
67 g (0.15 lbs)  
2 m (6.56 ft)  
Probe Tip Diameter  
* As defined in IEC 61010-031  
5 mm (0.20 inches)  
Ordering Information  
Product Description  
Product Code  
HVP120  
400 MHz, High Voltage Passive Probe  
High Voltage Replacement Accessories Kit  
PK-HV-002  
Replacement Accessories  
One of each of the following accessories are included with the HVP120. Replacement quantities are listed below.  
Coding Rings (set) 4 Colors (Qty 3 also included standard)  
Ground Lead 22 cm to 4 mm Banana plug (Qty 1)  
Solid Tip 0.8 mm (Qty 5)  
Spring Tip 0.8 mm (Qty 5)  
BNC Adapter 5.0-L (Qty 1)  
Insulating Cap 5.0-L (Qty 1)  
Protection Cap 5.0-L (Qty 1)  
Sprung Hook 5.0-L (Qty 1)  
Adjustment Tool T (Qty 1)  
PK1-5MM-106  
PK1-5MM-122  
PK1-5MM-125  
PK1-5MM-126  
PK1-5MM-127  
PK1-5MM-128  
PK1-5MM-129  
PK1-5MM-130  
PK1-5MM-131  
PK1-5MM-132  
PK1-5MM-133  
PK1-5MM-134  
Flexible Adapter 5.0-L (Qty 1)  
Safety Alligator Clip red (Qty 1)  
Ground Lead 22 cm (Qty 1)  
36  
HIGH VOLTAGE PROBES  
The PPE series includes four fixed-attenuation probes covering a range from  
2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for  
voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically  
rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation  
of the probe.  
PPE High-Voltage Probes Selection Guide Specifications  
Types  
Bandwidth Input R Input C Attenuation Maximum  
Probe Cable  
Encoding  
(MHz)  
400  
(Ω)  
(pF)  
< 6  
< 6  
< 6  
Voltage  
4 kV  
PPE4kV*  
PPE5kV*  
PPE6kV*  
50 M  
50 M  
50 M  
÷100  
÷100  
Yes  
Yes  
Yes  
2 m  
2 m  
2 m  
400  
5 kV  
400  
÷1000  
6 kV  
Teledyne LeCroy  
High Voltage Probe  
Model Numbers:  
PPE4KV  
PPE5KV  
PPE6KV  
Trimming Tool  
Security Ground Lead  
Ground Lead  
(22 cm)  
Flexible 4 mm  
Security Adapter  
BNC Adapter  
Insulating Tip  
IC Insulating Tip  
Straight Tip  
(0.8 mm)  
Spring Contact Tip  
(0.8 mm)  
Sprung Hook  
Crocodile Clip (Black)  
Crocodile Clip (Red)  
Ordering Information  
Product Description  
Product Code  
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 4 kV max. Voltage DC and Peak AC  
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 5 kV max. Voltage DC and Peak AC  
PPE4KV  
PPE5KV  
÷1000; 400 MHz; 50 MΩ High-Voltage Probe, 6 kV max. Voltage DC and Peak AC  
PPE6KV  
Accessory Kit for PPE1.2kV, 2kV, 4kV, 5kV, and 6kV  
Sprung Hook (red)  
Ground Lead (22 cm)  
Crocodile Clip  
PK103  
PK103-1  
PP005-GL22  
PK30x-2  
Probe Tip to BNC Adapter  
Spring Tip (0.8 mm)  
Rigid Tip V2A  
PP005-BNC  
PP005-ST8  
PP005-RT  
Supplied with probe:  
* Probe Kit: Trimming tool, ground lead, rigid tip, IC insulator, BNC adapter, tip insulator, spring hook, red crocodile clip.  
4 mm safety ground lead, and green/yellow crocodile clip.  
37  
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES  
38  
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES  
Teledyne LeCroy  
The HVFO is an affordable, optimally designed probe for measurement of  
Probe Adapter  
small signals floating on an HV bus in power electronics designs or for  
Model Numbers:  
EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpass-  
HVFO108  
es the measurement capabilities and signal fidelity of both conventional  
HV differential probes and acquisition systems that rely on galvanic high  
voltage isolation. Furthermore, it mitigates the need to rely on dangerous  
test setups that require floating the oscilloscope and probe.  
Opposite page:  
High Voltage Fiber Optically-isolated Probe with a  
WaveRunner 8000HD High Definition Oscilloscope.  
39  
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES  
The HVFO is an affordable, optimally designed probe for measurement of small  
signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD,  
and RF immunity testing sensor monitoring. It far surpasses the measurement  
capabilities and signal fidelity of both conventional HV differential probes and  
acquisition systems that rely on galvanic high voltage isolation. Furthermore,  
it mitigates the need to rely on dangerous test setups that require floating the  
oscilloscope and probe.  
Key Features  
150 MHz bandwidth  
Teledyne LeCroy  
High Voltage Fiber  
35 kV common-mode voltage rating (fiber optic isolation)  
Optically-isolated Probe  
Model Number:  
HVFO108  
Superior Noise and Rejection  
140 dB CMRR  
Low loop inductance  
Low attenuation  
Optical isolation reduces adverse loading of DUT  
Selectable tips from ±1V to ±40V  
Applications  
Upper-side gate drive signal measurements  
Floating control signal or sensor voltage measurements  
EMC, EFT, ESD, and RF immunity testing and system optimization  
Any small signal measurements with high common-mode voltage  
40  
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES  
Electrical  
Bandwidth  
150 MHz (typical, with tip attached)  
Rise Time (10-90%)  
Input Dynamic Range  
3.3 ns (typical)  
±1V, ±5V, ±10V, ±20V, ±40V (DC+peak AC) respectively with 1X, 5X, 10X, 20X or 40X attenuating tips.  
All tips are purchased as accessories (none are included with HVFO108 probe).  
Maximum Non-destruct Voltage 5 times the operating voltage rating (tip dependent)  
Common Mode Voltage Range  
Maximum Input Voltage to Earth ±35 kV (DC+Peak AC) (not for hand-held use, with adequate spacing between probe components and earth ground)  
Maximum Safe Input Voltage  
Offset  
±35 kV (DC+Peak AC) (not for hand-held use, with adequate spacing between probe components and earth ground)  
For hand-held use, 30 Vrms / 60 Vdc per IEC/EN 61010-031:2015  
Offset capability determined by oscilloscope offset available in a given gain (V/div) setting after accounting for total  
probe attenuation (total probe attenuation is twice the tip attenuation).  
Sensitivity  
10 mV/div to 1 V/div (1X tip), 50 mV/div to 5 V/div (5X tip), 100 mV/div to 10 V/div (10X tip), 200 mV/div to 20 V/div (20X  
tip), 400 mV/div to 40 V/div (40X tip)  
Gain Accuracy  
Input Impedance  
Input/Output Coupling  
Interface  
Cable Length  
Battery  
2.5% (typical), 4% (guaranteed)  
1 MΩ || 34 pF (1X tip); 5 MΩ || 26 pF (5X tip); 8 MΩ || 23 pF (10X tip); 10 MΩ || 22 pF (20X tip); 10 MΩ || 22 pF (40X tip)  
DC only  
ProBus  
1.25 m (4.1 feet) from input lead to oscilloscope connection (using included 1 meter fiber optic cable)  
6 hour battery life (typical). 2.5 hour re-charge time (typical, with user-supplied dedicated USB charger).  
5 hour re-charge time (typical) using supplied USB charging cable connected to oscilloscope USB port  
Noise, Rejection, and Electromagnetic Compatibility (EMC)  
CMRR (typical)  
140 dB (100 Hz), 120 dB (to 1 MHz), 85 dB (to 10 MHz),  
60 dB (to 60 MHz), 35 dB (to 150 MHz)  
Noise (Probe only)  
7 mVrms (1X tip), 35 mVrms (5X tip), 70 mVrms (10X tip), 140 mVrms (20X tip), 280 mVrms (40X tip)  
570 nV/√Hz  
8 kV contact discharge and 10 kV air discharge per IEC61000-4-2, criteria A  
Noise Density (Probe only)  
Electrostatic Discharge (ESD)  
Immunity  
Radiated RF Electromagnetic  
Field Immunity  
Immunity to Conducted  
Disturbance Induced by  
RF Fields  
25 V/m (80 MHz to 2.7 GHz) per IEC61000-4-3, criteria A  
10 V/m (150 kHz to 80 MHz) per IEC61000-4-6, criteria A  
Environmental  
Temperature  
Humidity  
10°C to 40°C (operating), -20°C to 70°C (non-operating)  
5% to 80% RH (non-condensing) up to 30°C, decreasing linearly to 45% RH at 50°C (operating)  
5% to 95% RH (non-condensing), 80% RH above 30°C, 45% RH above 50°C (non-operating)  
Up to 3000 m (operating), 10,000 m (non-operating)  
2, Indoor Use Only  
Altitude  
Pollution Degree  
Certifications  
CE Declaration of Conformity  
Low Voltage Directive 2014/35/EU (IEC/EN 61010-031:2015  
EMC Directive 2014/30/EU (IEC/EN 61326-1:2013)  
RoHS2 Directive 2011/65/EU  
Ordering Information  
Product Description  
Product Code  
High Voltage Fiber Optically-isolated Probe Models and Accessories  
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case, Qty. 1 Amplifier/Modulating Transmitter, Qty. 1  
Demodulating Receiver, Qty. 1 1m Fiber Optic Cable, Qty. 1 USB Charging Cable, Qty. 1 Micro-gripper set.  
Attenuating Tips must be ordered separately.  
HVFO108  
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory  
HVFO100-1X-TIP-U  
HVFO100-5X-TIP-U  
HVFO100-10X-TIP-U  
HVFO100-20X-TIP-U  
HVFO100-40X-TIP-U  
HVFO-1M-FIBER  
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory  
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory  
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory  
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory  
1m Spare Fiber Optic Cable Accessory  
6m Fiber Optic Cable Accessory  
NIST Traceable Calibration Certificate  
HVFO-6M-FIBER  
HVFO108-CCNIST  
41  
OPTICAL-TO-ELECTRICAL CONVERTERS  
OPTICAL-TO-ELECTRICAL CONVERTERS  
Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters  
Teledyne LeCroy  
Optical Probe  
are designed for measuring optical communications signals. Their broad  
wavelength range and multi-mode input optics make these devices ideal for  
applications including Ethernet, Fibre Channel, and ITU telecom standards.  
Available to support optical data rates up to 11.3 Gb/s with reference  
receivers, or slightly higher without reference receivers.  
Model Numbers:  
OE6250G-M  
OE695G  
OE425  
OE455  
OE525  
These wide- band multi-mode optical-to-electrical converters are designed  
for measuring optical communications signals. They connect to Teledyne  
LeCroy real-time oscilloscopes and provide capability for physical layer  
signal assessment using a variety of oscilloscope tools, such as  
SDAIII-CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis,  
mask testing, serial triggering and decoding, and other compliance and  
debug tools. Maximum data rate test capability is >11.317 Gb/s with  
reference receiver, or 12.5 Gb/s without.  
OE555  
Opposite page:  
OE6250G-M Optical Probe with a LabMaster 10 Zi-A oscilloscope.  
43  
OPTICAL-TO-ELECTRIC
Teledyne LeCroy  
Optical Probe  
Model Numbers:  
OE6250G-M  
OE695G  
OE425  
OE455  
OE525  
OE555  
OE6250G-M  
The OE6250G optical-to-electrical converter enables optical signal measure-  
ment of intensity-modulated signals up to 28 Gbaud and beyond on LabMaster  
or WaveMaster series real-time oscilloscopes. As a fully calibrated module, the  
OE6250G-M integrates seamlessly into the oscilloscope software to give optical  
intensity measurement straight out of the box. Teledyne LeCroy’s extensive tool-  
set includes powerful analysis tools for NRZ, PAM4, and other signal types, and  
enables custom signal processing and reference receiver implementation.  
Key Features  
Optical-to-electrical converter for  
intensity-modulated signals to 28  
Gbaud and higher  
OE6250G-M Specifications  
Typical  
Analog Bandwidth  
25 GHz (Bessel-Thomson response mode),  
36 GHz (Flatness response mode)  
830nm - 1600nm  
850nm, 1310nm, 1550nm  
-80 V/W  
– Up to 25 GHz bandwidth with  
a 4th-order Bessel-Thomson  
frequency  
response  
– Up to 36 GHz bandwidth with a flat  
frequency response  
Wavelength Range  
Calibration Wavelengths  
Conversion gain at 850nm  
Conversion gain at 1310nm  
Conversion gain at 1550nm  
Electrical output coupling  
5% compression point at 1550nm  
Noise measured up to 50GHz  
Optical Return Loss  
-125 V/W  
-125 V/W  
DC coupled  
4 mW (minimum)  
500 uV RMS  
19 dB  
DC-coupled detector for accurate  
signal reproduction with a real-time  
oscilloscope  
Polarization dependent loss at 1550 nm  
RF impedance  
Fiber (core/cladding)  
RF connector  
Optical Connector  
0.1 dB  
50 Ω  
50/125 µm  
2.92 mm  
FC/PC or SC/PC  
Fully calibrated and integrated  
Note: All specifications subject to change without notice.  
50/125 µm multi-mode fiber input  
Ideal for Eye Mask, Extinction Ratio,  
and Optical Modulation Amplitude  
(OMA) testing  
44  
OPTICAL-TO-ELECTRICAL CONVERTERS  
OE695G  
OE425/OE455/OE525/OE555  
The OE695G wide-band optical-to-electrical converter is  
ideal for measuring optical datacom and telecom signals  
with data rates from 622 Mb/s to 12.5+ Gb/s. Connection  
to a real-time Teledyne LeCroy oscilloscope is through the  
2.92 mm interface, with a provided adapter to connect to  
ProLink interfaces.  
The O/E converters contain calibration data that can be  
used to create optical reference receivers for SONET/  
SDH (up to OC48/STM16), Fibre Channel, Gigabit Ether-  
net, and other optical standards. This feature is available  
when the O/E is used on a supported oscilloscope. The  
universal reference receiver supports any data rate up  
to 3 GHz and remains calibrated on any channel of the  
oscilloscope.  
Key Features  
Compatible with LabMaster 10 Zi oscilloscopes  
Key Features  
Frequency range DC to 9.5 GHz (electrical, -3 dB)  
Frequency range to 5 GHz (6 GHz optical)  
62.5 µm or narrower multi-mode or single-mode  
Reference receiver support from 8GFC to 10GFC FEC, or  
Custom (<12.5Gb/s)  
fiber input  
Broad wavelength range:  
Full bandwidth mode (no reference receiver applied)  
– 500–870 nm (OE425, OE525)  
– 950–1630 nm (OE455, OE555)  
62.5/125 µm multi-mode or single-mode fiber input  
High responsivity  
Broad wavelength range (750 to 1650 nm)  
Low noise  
+7 dBm (5 mW) max peak optical power  
Included Accessories:  
Multi-mode optical fiber jumper FC-FC  
FC to ST adapter  
Low noise (as low as 25 pW/Hz)  
FC to SC adapter  
Ideal for Eye Mask, Extinction Ratio, and Optical  
Modulation Amplitude (OMA) testing  
Ordering Information  
Product Description  
Product Code  
Optical-to-Electrical Converter, DC to 36 GHz, 830 to 1600nm  
OE6250G-M  
Optical-to-Electrical Converter, 785 to 1550 nm, 2.92 mm connector with ProLink adapter  
Optical-to-Electrical Converter, 500–870 nm ProBus BNC Connector * Limited Availability  
Optical-to-Electrical Converter, 950–1630 nm ProBus BNC Connector * Limited Availability  
Optical-to-Electrical Converter, 500–870 nm ProLink BMA Connector * Limited Availability  
Optical-to-Electrical Converter, 950–1630 nm ProLink BMA Connector  
OE695G  
OE425  
OE455  
OE525  
OE555  
45  
PASSIVE PROBES  
PASSIVE PROBES  
Teledyne LeCroy  
Passive Probe  
Passive probes are the standard probe provided with most  
oscilloscopes. Typical passive probes provide a ÷10 attenuation and  
feature a high input resistance of 10 MΩ. This high input resistance  
means that passive probes are the ideal tool for low frequency signals  
since circuit loading at these frequencies is minimized. Passive probes  
are designed to handle voltages of at least 400 V, some as high as  
600 V. Teledyne LeCroy passive probes feature an attenuation sense  
pin which tells the oscilloscope to scale the waveforms automatically  
requiring no user input.  
Model Numbers:  
PP016  
PP018  
PP019  
PP020  
PP021  
PP022  
PP023  
PP024  
PP025  
PP026  
47  
PASSIVE PROBES  
Each passive probe is recommended for a certain oscilloscope, using the right  
passive probe with the right oscilloscope means that the probe can be properly  
compensated across the entire bandwidth. Using probes with a different  
oscilloscope will only let you compensate for low frequencies.  
Specifications  
Types  
Bandwidth  
Input R  
Input C Attenuation Maximum  
Voltage  
Diameter  
PP016  
300 MHz/  
10 MHz  
10 MΩ/  
1 MΩ  
12 pF/  
46 pF  
10 pF  
12 pF  
11 pF  
11 pF  
10 pF  
10 pF  
10 pF  
10 pF  
10 pF  
÷10/  
÷1  
600 V  
5 mm  
PP018  
PP019  
PP020  
PP021  
PP022  
PP023  
PP024  
PP025  
PP026  
500 MHz  
200 MHz  
500 MHz  
500 MHz  
500 MHz  
500 MHz  
500 MHz  
500 MHz  
500 MHz  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
10 MΩ  
÷10  
÷10  
÷10  
÷10  
÷10  
÷10  
÷10  
÷10  
÷10  
350 V  
500 V  
500 V  
500 V  
500 V  
500 V  
500 V  
500 V  
500 V  
5 mm  
5 mm  
5 mm  
2.5 mm  
2.5 mm  
2.5 mm  
5 mm  
Teledyne LeCroy  
Passive Probe  
Model Numbers:  
PP016  
5 mm  
5 mm  
PP018  
PP019  
PP020  
PP021  
Passive Probe Accessories for PP016  
Replacement Part Kit: PKIT3-5MM-101  
PP022  
PP023  
PP024  
Trimmer Tool  
PP026  
Color Coding Rings  
(set)  
Ground Lead  
Sprung Hook  
Rigid Tip  
BNC Adapter  
Ground Spring  
Tip Insulator  
IC Tip Insulator  
48  
PASSIVE PROBES  
Passive Probe Accessories for  
Passive Probe Accessories for  
PP019 and PP020 – Part numbers in blue  
Replacement Part Kit: PKIT4-5MM-101  
PP024, PP025, and PP026 – Part numbers in gray  
Replacement Part Kit: PKIT6-5MM-101  
PP021, PP022, and PP023  
Replacement Part Kit: PKIT5-2.5MM-101  
PK4-5MM-5  
PK5-PK6-001  
Trimmer Tool  
PK5-PK6-001  
Trimmer Tool  
PK4-5MM-8  
PK5-PK6-002  
Color Coding Rings  
(set)  
PK5-PK6-002  
Color Coding Rings  
(set)  
PK5-2.5MM-111  
Swivel Ground  
Lead Adapter  
PK4-5MM-2  
PK6-5MM-103  
Ground Lead with Alligator Clip  
PK5-2.5MM-105  
Long Collar  
PK5-2.5MM-103  
Short Collar  
PK6-5MM-107  
Spring Tip  
PK4-5MM-4  
PK6-5MM-101  
Rigid Probe Tip  
PK5-2.5MM-101  
Ground Lead with  
Alligator Clip  
PK4-5MM-1  
PK6-5MM-102  
Sprung Hook  
PK5-2.5MM-109  
BNC Adapter 2.5mm  
PK6-5MM-108  
Probe Tip Cover  
PK5-2.5MM-104  
Sprung Hook  
PK4-5MM-3  
PK6-5MM-106  
BNC Adapter 5mm  
PK5-2.5MM-113  
PCB Adapter  
PK6-5MM-105  
PCB Adapter  
PK4-5MM-6  
PK6-5MM-109  
IC Tip Insulator  
PK5-2.5MM-110  
Swivel Ground Lead  
PK5-2.5MM-112  
Ground Spring  
PK4-5MM-7  
PK6-5MM-110  
Tip Insulator  
PK5-2.5MM-106  
IC Tip Insulators (Black, Brown, Blue, Green, Gray)  
PK4-5MM-9  
PK6-5MM-104  
Ground Spring  
PK5-2.5MM-107  
Tip Insulator  
2.5mm Cap  
PK6-5MM-108  
Probe Tip Cover  
PK5-2.5MM-102  
Rigid Probe Tip  
Ordering Information  
Product Description  
Product Code  
PK5-2.5MM-114  
Spring Tip  
10:1, 10 MΩ, 300 MHz Passive Probe  
PP016  
PP018  
PP019  
PP020  
PP021  
PP022  
PP023  
PP024  
PP025  
PP026  
500 MHz Passive Probe, 10:1, 10 MΩ  
250 MHz Passive Probe, 10:1, 10 MΩ  
500 MHz Passive Probe, 10:1, 10 MΩ  
PK5-2.5MM-108  
Probe Tip Cover  
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ  
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ  
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ  
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ  
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ  
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ  
49  
PROBE ADAPTERS  
Probe adapters provide simple and easy interface of third-party probes as well  
as change between the different Teledyne LeCroy Oscilloscope input and cable  
types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapt-  
ers, changing between the Teledyne LeCroy Oscilloscope’s input type may have  
an effect on the overall performance of the channel.  
Teledyne LeCroy  
Probe Adapter  
Model Numbers:  
CA10  
TPA10  
CA10  
The CA10 is a programmable and customizable interface device that seamlessly  
incorporates third party current transducers/transformers with Teledyne LeCroy  
oscilloscopes or motor drive analyzers. The easy to use interface provides the  
ability for the CA10 to be programmed to contain the specifications of the current  
sensor allowing it to automatically correct for the gain or attenuation and display  
results in Ampere units. This allows the third party device to be recognized and  
operate as if it were a Teledyne LeCroy probe.  
Key Features  
Provides ability for third party  
current sensor to operate like a  
Teledyne LeCroy probe  
Programmable EEPROM for  
saving third party current sensor  
parameters  
Specifications  
Allows for addition of shunt  
Input Coupling  
DC, AC, Both  
1MΩ or 50Ω  
Input Termination  
resistorandRLCltercomponents  
Programmable Bandwidth Filters  
Transformer/Transducer Interface  
Scaling Factors  
Resistive Termination (if required)  
Oscilloscope Interface  
Full, 200 MHz, 20 MHz  
ProBus Active interface with  
BNC  
Programmable  
Customizable (See Operator’s Manual for details)  
automatic scaling in A/div  
Easy to use, saves time and  
Teledyne LeCroy ProBus  
possible errors  
Note: Some third party devices will require a separate power supply or batteries. The CA10 does not have  
the ability to supply the power to these devices.  
Ordering Information  
Product Description  
Product Code  
ProBus Current Sensor Adapter  
CA10  
Included with Standard Configuration CA10  
Description  
CA10 ProBus Current Adapter  
Qty  
1
Heat-Shrink tubing (6" length)  
Removable Labels (sheet of 20)  
1
1
50  
PROBE ADAPTERS  
Key Features  
Allows TekProbe™ interface level II  
probes to work with any  
ProBus-equipped Teledyne LeCroy  
oscilloscope  
Automatic probe detection  
Provides all necessary power and  
offset control to the attached probe  
Supports probes up to 4 GHz  
Easy firmware updates  
Wide variety of probes  
supported including:  
Preamplifiers  
Current Probes  
Single-Ended Active Probes  
Differential Active Probes  
TPA10  
The TPA10 ProBus™ Probe Adapter enables you to connect select TekProbe  
interface level II probes to any ProBus-equipped Teledyne LeCroy instrument.  
The TPA10 supplies all necessary power and offset control to the probe and  
automatically detects which probe is attached.  
Specifications  
Ordering Information  
Product Description  
Electrical Characteristics  
Bandwidth  
Product Code  
4 GHz (adapter only)  
+15V, -15V, +5V, -5V (each 2%)  
±1V (1%)  
TPA10 ProBus Adapter  
TPA10  
Power Supplies  
Offset Voltage  
Max. Input Voltage  
47 V , 33 V  
pk  
rms  
Supported Probes  
The following TekProbe devices are supported for use  
with TPA10:  
Environmental  
Operating Temperature Range  
0 to 50 ºC  
Non-operating Temperature Range -40 to +70 ºC  
Humidity  
Preamplifiers  
5% to 95% RH (10 to 40 ºC);  
5% to 75% (above 40 ºC);  
1 MHz Differential Preamplifier  
ADA400A  
RH not controlled below 10 ºC  
Operating Altitude  
3000 meters maximum  
Current Probes  
50 MHz AC/DC Current Probe  
TCP202/TCP202A  
Physical  
Dimensions (WxHxD)  
39 mm x 31.1 mm x 88.6 mm  
(1.54” x 1.22” x 3.49”)  
Single-ended Active Probes  
750 MHz Single-ended Active Probe  
1 GHz Single-ended Active Probe  
1.5 GHz Single-ended Active Probe  
4 GHz Single-ended Active Probe  
4 GHz Single-ended Active Probe  
P6205  
P6243  
P6245  
P6241  
P6249  
Weight  
119 g (0.26 lb)  
The TPA10 requires the Teledyne LeCroy oscilloscope to be running firmware  
version 7.8.0.0 or greater.  
Differential Active Probes  
100 MHz Differential Probe  
50 MHz Differential Probe  
400 MHz Differential Probe  
1 GHz Differential Probe  
P5205/P5205A  
P5210/P5210A  
P6246  
P6247  
1.5 GHz Differential Probe  
500 MHz Differential Probe  
1 GHz Differential Probe  
P6248  
P6250  
P6251  
51  
TRANSMISSION LINE PROBES  
Transmission line probes are a special type of passive probe designed for use at  
very high frequencies. They replace the high impedance probe cable found in a  
traditional passive probe with a precision transmission line, with a characteristic  
impedance that matches the oscilloscope input (50 Ω). This greatly reduces  
the input capacitance to a fraction of a picofarad, minimizing the loading of  
high frequency signals. A matching network at the tip increases the DC input  
resistance. While they have lower DC input resistance than a traditional passive  
probe (usually 500 Ω to 5 kΩ), the input impedance of these probes remains  
nearly constant over their entire frequency range. A traditional ÷10 passive probe  
will have a 10 MΩ input impedance at DC, however this impedance drops rapidly  
with frequency, passing below the input impedance of a transmission line probe at  
less than 100 MHz.  
Teledyne LeCroy  
Transmission Line Probe  
Model Number:  
In some applications, transmission line probes offer advantages over active  
probes. In addition to being less expensive, their passive design is more robust  
to over voltage and ESD exposure. They are useful in applications producing fast  
rising, narrow pulses with amplitudes which exceed the dynamic range of active  
probes. They also tend to have less parasitic effects on frequency response.  
PP066  
52  
TRANSMISSION LINE PROBES  
PP066  
The PP066 is a high-bandwidth passive probe designed for use  
with the WaveMaster and other high-bandwidth oscilloscopes  
with 50 Ω input termination. This very low capacitance probe  
provides an excellent solution for higher frequency applications,  
especially the probing of transmission lines with 20–100 Ω  
impedance. The PP066 accommodates a wide range of  
applications, including probing of analog and digital ICs  
commonly found in computer, communications, data storage,  
and other high-speed designs.  
Key Features:  
Interchangeable attenuator tips  
Signal integrity at high bandwidth  
Standard SMA cable connection  
Ultra low capacitance  
PP066 Specifications  
Electrical Characteristics  
Bandwidth  
DC to 7.5 GHz  
< 47 ps  
Risetime  
Input Capacitance  
Input Resistance  
< 0.20 pF  
500 Ω (÷10 cartridge)  
1000 Ω (÷20 cartridge)  
15 V rms  
Maximum Voltage  
Cable Length  
1 m  
Ordering Information  
Product Description  
Product Code  
PP066  
7.5 GHz Low Capacitance Passive Probe  
(÷10, 1 kΩ; ÷20, 500 Ω)  
Included with PP0066  
PACC-AD001, SMA to BNC Adapter  
53  
THIS PAGE INTENTIONALLY LEFT BLANK.  
54  
THIS PAGE INTENTIONALLY LEFT BLANK.  
55  
1-800-5-LeCroy  
teledynelecroy.com  
Local sales offices are located throughout the world.  
Visit our website to find the most convenient location.  
tlec_probecatalog-26jan21  
© 2021 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.  
Product or brand names are trademarks or requested trademarks of their respective holders.  

相关型号:

PACD2404C/R

Trans Voltage Suppressor Diode, Bidirectional, 4 Element, Silicon, CSP-6
CALMIRCO

PACD2408C/R

Trans Voltage Suppressor Diode, Bidirectional, 8 Element, Silicon, CSP-10
CALMIRCO

PACD2416C/R

Trans Voltage Suppressor Diode, Bidirectional, 16 Element, Silicon, CSP-20
CALMIRCO

PACDN002

17 CHANNEL ESD PROTECTION ARRAY
CALMIRCO

PACDN002Q

17 CHANNEL ESD PROTECTION ARRAY
CALMIRCO

PACDN002Q/T

Trans Voltage Suppressor Diode, Unidirectional, 34 Element, Silicon, MO-137AD, QSOP-20
CALMIRCO

PACDN002S

17 CHANNEL ESD PROTECTION ARRAY
CALMIRCO

PACDN004

2 CHANNEL ESD PROTECTION ARRAY
CALMIRCO

PACDN004

2-Channel ESD Protection Array
ONSEMI

PACDN004/B

Trans Voltage Suppressor Diode, Unidirectional, 4 Element, Silicon, SOT-143, 4 PIN
CALMIRCO

PACDN004/R

Trans Voltage Suppressor Diode, Unidirectional, 4 Element, Silicon, SOT-143, 4 PIN
CALMIRCO

PACDN004/T

Trans Voltage Suppressor Diode, Unidirectional, 4 Element, Silicon
CALMIRCO