PACC-MS005 [TELEDYNE]
FREEHAND PROBE HOLDER ZS;型号: | PACC-MS005 |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | FREEHAND PROBE HOLDER ZS |
文件: | 总56页 (文件大小:5517K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Oscilloscope Probes and
Probe Accessories
Learn More: teledynelecroy.com/probes
PROBE SELECTION
GUIDE
Teledyne LeCroy has a wide variety of world class probes and amplifiers to compliment its
product line. From the ZS high impedance active probes to the DH Series Differential
High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and
probe accessories provide optimum mechanical connections for signal measurement.
Front Cover:
DH Series Differential High-bandwidth Probes
60 V Common Mode Differential Probes - p. 4 - 5
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
DL05-HCM
DL10-HCM
Active Voltage Rail Probes - p. 6 - 9
RP4030
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Active Voltage Probes - p. 10 - 13
ZS1000
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
ZS1500
✓
✓
ZS2500
ZS4000
Current Probes - p. 14 - 17
CP030
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
CP030A
CP031
CP031A
CP150
CP500
CA10
Differential Probes - p. 18 - 27
ZD200
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
ZD500
ZD1000
ZD1500
AP033
✓
✓
✓
✓
✓
✓
✓
✓
✓
D410-A-PB2
D420-A-PB2
D400A-AT-PB2
D610-A-PB2
D610-A-PL
D620-A-PB2
D620-A-PL
D600A-AT-PB2
D600A-AT-PL
D830-PB2
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
D830-PL
D1330-PL
DH08-PB2
DH08-PL
DH13-PL
DH16-PL
DH20-PL
DH25-2.92MM
DH30-2.92MM
2
Learn More: teledynelecroy.com/probes
High Voltage Differential Probes - p. 28 - 33
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
HVD3102A
✓
HVD3106A
✓
HVD3106A-6M
✓
HVD3206A
✓
HVD3206A-6M
✓
HVD3220
✓
HVD3605A
✓
AP031
High Voltage Probes - p. 34 - 37
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
HVP120
✓
PPE4KV
✓
PPE5KV
✓
PPE6KV
High Voltage Fiber Optically-isolated Probes - p. 38 - 41
✓
✓
✓
✓
✓
✓
✓
✓
HVFO108
Optical-To-Electrical Converters - p. 42 - 45
OE6250G-M
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
OE695G
✓
✓
✓
✓
OE425
OE455
OE525
OE555
Passive Probes - p. 46 - 49
PP016
PP018
✓
✓
✓
PP019
✓
PP020
✓
✓
✓
✓
PP021
✓
✓
PP022
✓
✓
✓
✓
PP023
PP024
PP025
✓
✓
✓
✓
PP026
Probe Adapters - p. 50 - 51
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
CA10
✓
TPA10
Transmission Line Probes - p. 52 - 53
✓
✓
✓
PP066
3
60 V COMMON MODE DIFFERENTIAL PROBES
The 60 V Common Mode Differential Probes are the ideal probes for
low voltage GaN power conversion measurement with the highest
accuracy, best CMRR, and lowest noise.
Ideal Probes for 48 V GaN
Power Conversion
Lowest Noise and
Highest Rejection
60 V of common mode and 80 V
differential input range with 1 GHz of
bandwidth, make these probes ideal
for low voltage GaN power conversion
measurements. The 60 V of common
mode is well suited for handling any
The Common Mode Rejection Ratio
(CMRR) is exceptional to very high
frequencies. This provides for the best
measurement performance when
measuring very fast slew rate (high
dV/dt) PWM signals typical of GaN
Teledyne LeCroy
60 V Common Mode
Differential Probe Model
Numbers:
float of the battery and bulk/absorption devices and systems. Exceptional
DL05-HCM
voltage during charging, while the 80 V
differential input range provide margin
for any overshoot.
CMRR combined with low probe noise
and high offset capability makes the
probes capable of measuring very
small control signals floating on high
common mode voltages.
DL10-HCM
Highest Accuracy
The DL-HCM probes are calibrated for
Key Applications
48 V motors and drives
•
high-precision measurements to within Wide Variety of Tips
0.5% at DC and 0.1 dB flatness from
High-power DC-DC converters
•
The DL-HCM probes provide the
GaN-based PDNs
•
DC to 100 MHz. This provides for high
perfect combination of high
AC-DC switch-mode power
•
accuracy of top and base voltage levels performance and flexibility for
supplies
of pulse-width modulated signals. The
Precision Gain Calibration capability
connecting to any device under test.
An optional accessory kit and high
Wireless charging systems
•
Gate-drive measurements
•
permits further measurement precision temperature solder-in tip are available
by improving the gain accuracy and
removing small offset drifts from the
measurement configuration.
for further connectivity options.
Key Features
Ideal probe for 48 V Power Conversion
500 MHz and 1 GHz bandwidth
•
Ordering Information
80 V dynamic range
•
Product Description
Product Code
60 V common mode
•
500 MHz 60V Common Mode Differential Probe.
Includes standard set of leads and tips.
1 GHz 60V Common Mode Differential Probe.
Includes standard set of leads and tips.
DL-HCM series high-temperature solder-in tip,
30 MHz bandwidth, 1 meter length.
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and
Y-banana adaptor.
DL05-HCM
Highest accuracy
DL10-HCM
0.5% gain accuracy
•
DL-HCM-HiTemp
DL-HCM-Acc-Kit
Precision gain calibration
•
Best LF flatness (0.1 dB)
•
Standard leads and tips
High performance solder-in tips (Qty. 2)
2” solder-in tip
Lowest noise and highest rejection
Browser
Y-lead socket (2” and 5”)
Mini grabbers (Qty. 3)
Ground lead
Single pin (Qty. 6)
Straight pin header (Qty. 2)
4
60 V COMMON MODE DIFFERENTIAL PROBES
DL05-HCM
500 MHz (guaranteed, without leads)
500 MHz (High performance solder-in and browser)
500 MHz (2" Y-lead/solder-in)
DL10-HCM
1 GHz (guaranteed, without leads)
1 GHz (High performance solder-in and browser)
800 MHz (2" Y-lead)
Bandwidth*
500 MHz (5" Y-lead)
700 MHz (solder-in)
30 MHz (Hi-Temp lead)
500 MHz (5" Y-lead)
30 MHz (Hi-Temp lead)
Rise Time (10-90%)*
700 ps
350 ps
Differential Voltage Range
Common Mode Voltage Range
80 V (DC + peak AC) from 200 mV/div to 20 V/div
±60 V (DC + peak AC)
Maximum Input Voltage to Earth 80 V (DC + peak AC), max 60 V DC (either input to ground)
Maximum Safe Input Voltage
Sensitivity
For Hand-held use: 28.28 Vrms or 60 V DC (referenced to ground) per IEC/EN 61010-031:2015
200 mV/div to 1 V/div (7.8x)
1.02 V/div to 2.5 V/div (17.5x)
2.55 V/div to 20 V/div (70x)
±0.5% (guaranteed)
≤ 0.075%/°C, can be calibrated out with precision gain cal
DC to 100MHz: 0.1 dB
DC Gain Accuracy
DC Gain Drift
Frequency Response Flatness
Offset Range
Attenuation
±60V
7.8x / 17.5x / 70x
Input Impedance
Input/Output Coupling
Output Termination
Interface
200 kΩ || 0.6 pF (between inputs), 100 kΩ || 1 pF (either input to ground)
DC
50 Ω
ProBus
Cable Length
1.42 m from probe sockets to oscilloscope connection
Noise and Rejection
CMRR
DC - 10 kHz: 80 dB
100 kHz: 70 dB
1 MHz: 55 dB
DC - 10 kHz: 80 dB
100 kHz: 70 dB
1 MHz: 55 dB
100 MHz: 50 dB
1 GHz: 30 dB
100 MHz: 50 dB
500 MHz: 35 dB
Noise (Probe)
200 mV/div to 1 V/div: 3.25mVrms
1.02 V/div to 2.5 V/div: 4.5mVrms
2.55 V/div to 20 V/div: 14.5mVrms
200 mV/div to 1 V/div: 4.3mVrms
1.02 V/div to 2.5 V/div: 6mVrms
2.55 V/div to 20 V/div: 20mVrms
DL-HCM Probe
Straight Pin Header
Qty: 2
Browser
Qty: 1
High Performance
Solder-in
Qty: 2
2” Y-lead
Qty: 1
2” Solder-in
Qty: 1
High Temperature Lead
Qty: 1
Ground lead
Qty: 1
(Optional –
Included with
DL-HCM-HiTemp)
5” Y-lead
Qty: 1
Y-banana Adaptor
Qty: 1
(Optional –
Included with DL-HCM-Acc-Kit)
Single Pin
Qty: 6
Hands Free Probe Holder
(Optional –
Included with
DL-HCM-Acc-Kit)
Mini-Grabber
Qty: 1
Micro-Grabbers Mini-Grabbers
Qty: 2
Qty: 2
(Optional –
Included with DL-HCM-Acc-Kit)
5
ACTIVE VOLTAGE RAIL PROBE
6
ACTIVE VOLTAGE RAIL PROBE
The RP4030 is designed specifically to probe a 50Ω DC power/voltage rail.
Teledyne LeCroy
Active Voltage Rail Probe
Model Numbers:
The probe has large built-in offset, low attenuation (noise), and high DC input
impedance. Built-in offset and low attenuation permit the power/voltage rail
to be offset in the oscilloscope by its mean DC voltage with high oscilloscope
gain (sensitivity) to achieve a noise-free view of small signal variations. The
high DC input impedance eliminates loading of the DC rail.
RP4030
Opposite page:
Active Voltage Rail Probes RP4030 with a
WaveRunner 8000HD High Definition Oscilloscope.
7
ACTIVE VOLTAGE RAIL PROBE
Teledyne LeCroy
Active Voltage Rail Probe
Model Number:
RP4030
Key Features
4 GHz Bandwidth
±30V Offset Capability
±800mV Dynamic Range
50 kΩ DC Input Impedance
Large Offset Range
1.2x Attenuation (Low Additive
Noise, ~5%)
Permits the DC signal to be displayed in the vertical center of the oscilloscope
grid with a high-sensitivity gain setting.
MCX terminated cable with wide
variety of connections:
Low Attenuation and Noise
The probe attenuation is a nominal 1.2x coupled to the oscilloscope at DC 50 Ω.
This keeps additive noise to a minimum, and makes it exceptionally useful with
High Definition oscilloscopes for lowest noise at highest sensitivity gain settings.
Solder-in (4 GHz)
Coaxial Cable to
•
•
U.FL receptacle (3 GHz)
High DC Input Impedance
MCX PCB Mount (4 GHz)
Browser (350 MHz)
•
50 kΩ input impedance at DC effectively eliminates probe loading on the DC
power/voltage rail and provides for more accurate measurements and signal
fidelity.
•
ProBus Interface
8
ACTIVE VOLTAGE RAIL PROBE
4 GHz of Bandwidth
Wide Assortment of
Tips and Leads
Provides maximum bandwidth for probing near the CPU,
and the perfect match with the 4 GHz, 12 bit WavePro HD
when making power integrity measurements.
The RP4030 is supplied standard with solder-in and coaxial
cables with MCX and U.FL PCB receptacle mounts. A
browser tip is optionally available. Additional receptacles or
leads may be purchased as accessories and left connected
in circuit for easy connection of different signals during
different test or validation stages.
Specifications
Ordering Information
Electrical Characteristics
Bandwidth
4 GHz (guaranteed, MCX receptacle)
4 GHz (typical, solder-in lead)
3 GHz (typical, U.FL cable +
receptacle)
Product Description
Product Code
Power/Voltage Rail Probe
RP4030
350 MHz (typical, browser)
4 GHz, 1.2x, ±30V offset, ±800mV dynamic range
Rise Time (10-90%)
110 ps (typical, MCX receptacle or
solder-in lead)
Includes Qty. 1 ProBus compatible probe offset amplifier with 50 kΩ DC
input impedance and SMA input connection for provided 0.9m SMA to
MCX extension cable. Also supplied are Qty. 3 MCX solder-in leads, Qty.
3 MCX PCB Mounts, Qty. 3 MCX to U.FL coaxial cables, Qty. 5 U.FL PCB
Mounts, Qty. 1 MCX to SMA adapter, and soft carrying case. Browser tip
sold separately.
350 MHz Browser Tip Accessory
Includes 0 Ω (1x), 450 Ω (10x) and 950 Ω (20x) tips.
Input Capacitance
DC Input Resistance
Offset Range
0.1 uF (in series with 50Ω)
50 kΩ
±30V
1.2x
±800 mV
±50V
~5% additive to oscilloscope noise
Attenuation
RP4000-BROWSER
Input Dynamic Range
Non-destruct Voltage
Noise
Oscilloscope Termination
DC 50Ω
Environmental
Operating Temperature Range
0 to 50 ºC
Non-operating Temperature Range -40 to +70 ºC
Humidity
5% to 80% RH (non-condensing) up
to 30 ºC, decreasing linearly to to 45%
RH at 50 ºC
Operating Altitude
3000 meters maximum
Physical
RP4030
Probe: 38.1 mm W x 15.9mm H x
73mm L (1-1/2” x 5/8” x 2-7/8”)
SMA to MCX Cable: 914mm L (36”)
MCX to Solder-in Lead: 191mm (7-
1/2”) usable length
MCX to U.FL Plug Coaxial Cable:
102mm (4”) usable length
Accessories and Consumables
RP4000-BROWSER
11.9mm W x 9.5mm H x 38mm L
(15/32” x 3/8” x 1-1/2”)
Qty. 3 MCX 4 GHz solder-in leads
RP4000-MCX-LEAD-SI
RP4000-MCX-PCBMOUNT
RP4000-MCX-CABLE-UFL
SMA to SMA Cable: 1m (39-3/8”)
usable length
Qty. 10 MCX PCB mount receptacle
Qty. 3 MCX to U.FL 3 GHz ultra-mini
coax cable
Other
Oscilloscope Interface
Software Requirements
Teledyne LeCroy ProBus
Qty. 10 U.FL PCB mount receptacles
RP4000-UFL-PCBMOUNT
Teledyne LeCroy MAUI 8.2.1.1 or
higher
Weight
119 g (0.26 lb)
9
ACTIVE VOLTAGE PROBES
10
ACTIVE VOLTAGE PROBES
Engineers must commonly probe high-frequency signals with high
Teledyne LeCroy
signal fidelity. Typical passive probes with high input R and C provide good
response at lower frequencies, but inappropriately load the circuit and
distort signals at higher frequencies. Active voltage probes feature both
high input R and low input C to reduce circuit loading across the entire
probe/oscilloscope bandwidth. With low circuit loading and a form factor
that allows probing in confined areas, the active voltage probe becomes
the everyday probe for all different types of signals and connection points.
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
Opposite page:
ZS Series High Impedance Active Probe
11
ZS SERIES ACTIVE PROBES
The ZS Series probes are high impedance, low capacitance active probes that
maintain high signal fidelity through 4 GHz. A small form factor and a wide variety
of accessories ensures the ZS probe meets every difficult probing challenge.
Engineers must commonly probe high frequency signals with high signal fidelity.
Typical passive probes with high input R and C provide good response at lower
frequencies but inappropriately load the circuit and distort signals at higher
frequencies. The ZS Series features both high input R (1 MΩ) and low input C
(0.6 pF and 0.9 pF) to reduce circuit loading across the entire probe/oscilloscope
bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes. The ZS1500 is
ideal for 1 GHz oscilloscopes, the ZS2500 is ideal for 2 GHz oscilloscopes, and the
ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
Teledyne LeCroy
Active Voltage Probe
Model Numbers:
ZS1000
ZS1500
ZS2500
ZS4000
PK-ZS-010
Channel ID
Colored Clips
ZS4000
PK-ZS-019
Freehand Probe Holder
PACC-PT005
Bent Tip
PACC-PT003
IC Tip
PK-ZS-001
Probe Tip - Standard
PK-ZS-017
Pogo Tip
PK-ZS-006
Right Angle Socket
PK-ZS-023
Straight Pin
Lead - 13cm
PK-ZS-014
Y-Lead
Adapter
PK-ZS-022
Straight Pin
Lead - 7cm
PACC-LD003
Right Angle
Pin Lead - 5cm
PACC-LD004
Right Angle
Pin Lead - 10cm
PK-ZS-018
2.54 mm Square
Pin Adapter
PK-ZS-020
Pogo Ground Lead
PK-ZS-016
Offset Ground
(Z Lead)
PK-ZS-009
Copper Tape
PK-ZS-015
Ground Blade - Wide
PK-ZS-021
Ground Blade -
Narrow
PK-ZS-024
2.54 mm PCB
Adapter
PK-ZS-007R
Microclip Sprung
Hook, Red
PK-ZF-025
QFPIC Clip Yellow -
Short
PK-ZF-025
QFPIC Clip Green -
Short
PK-ZS-007B
Microclip Sprung
Hook, Black
12
ZS SERIES ACTIVE PROBES
ZS1000
ZS1500
ZS2500
PK-ZS-010
Channel ID
Colored Clips
PACC-MS005
Freehand Probe Holderk
PACC-PT005
Bent Tip
PACC-PT003
IC Tip
PK-ZS-001
PK-ZS-013
Pogo Tip
Probe Tip
-
Standard
PK-ZS-006
Right Angle Socket
Qty:
3
PK-ZS-012
2.54 mm Square Pin
Adapter
PK-ZS-004
Single Lead
Long
PK-ZS-005
Y-Lead
Adapter
PK-ZS-003
Single Lead
Short
PACC-LD003
Right Angle
Pin Lead - 5cm
-
-
PACC-LD004
Right Angle
Lead - Long
PACC-CD008
Pogo Ground Lead
PK-ZS-002
Offset Ground
PK-ZS-009
Copper Tape
PK-ZS-011
Ground Blade Wide
-
PK-ZS-008
Ground Blade - Narrow
PK-ZS-007R
Microclip Sprung
Hook, Red
PK-ZS-007B
Microclip Sprung
Hook, Black
Ordering Information
Product Description
ZS1000 ZS1500 ZS2500 ZS4000
Specifications
Product Code
Electrical Characteristics
4 GHz, 0.6 pF, 1 MΩ
ZS4000
Probe Bandwidth
Input Capacitance
DC Input Resistance
Probe Offset Range
Attenuation
Input Dynamic Range
Non-destruct Voltage
1 GHz
1.5 GHz
0.9 pF
2.5 GHz
4 GHz
0.6 pF
High Impedance Active Probe
2.5 GHz, 0.9 pF, 1 MΩ
ZS2500
ZS1500
1 MΩ
±12 V
÷10
High Impedance Active Probe
N/A
1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probe
±8 V
20 V
1 GHz, 0.9 pF, 1 MΩ
ZS1000
High Impedance Active Probe
Set of 4 ZS2500, 2.5 GHz, 0.9 pF, 1 MΩ
ZS2500-QUADPAK
ZS1500-QUADPAK
ZS1000-QUADPAK
General Characteristics
High Impedance Active Probes
Cable Length
1.3 m
Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes
Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ
High Impedance Active Probes
Standard Accessory/Quantity
ZS1000
ZS1000
Replacement ZS1500
Part Number ZS2500 ZS4000
Replacement ZS1500
Accessory Description
2.54 mm PCB Adaptor
2.54mm Square Pin Adapter
2.54mm Square Pin Adaptor
IC Tip
Part Number ZS2500 ZS4000
Accessory Description
Offset Ground – Z Lead
Pogo Ground Lead
Pogo Ground Lead
Pogo Tip
PK-ZS-024
PK-ZS-012
PK-ZS-018
PACC-PT003
PACC-PT005
5
PK-ZS-002
PK-ZS-020
PACC-CD008
PK-ZS-017
PK-ZS-013
PK-ZS-001
PK-ZS-025
PACC-LD004
PACC-LD003
PK-ZS-006
PK-ZS-023
PK-ZS-004
PK-ZS-022
PK-ZS-003
PK-ZS-005
PK-ZS-014
1
1
1
3
1
1
1
1
1
1
Bent Tip
Pogo Tip
1
3
Channel ID Clips
Probe Tip – Standard
QFPIC Clips (set of 2)
Right Angle Lead – Long
Right Angle Lead – Short
Right Angle Socket
Straight Pin Lead – Long
Straight Pin Lead – Long
Straight Pin Lead – Short
Straight Pin Lead – Short
Y Lead Adapter
3
1
1
1
1
1
PK-ZS-010
4
2
1
(Set of 4 colors)
Copper Tape Pad
PK-ZS-009
PK-ZS-019
PACC-MS005
PK-ZS-008
PK-ZS-011
PK-ZS-021
PK-ZS-015
2
1
1
1
1
Freehand Probe Holder
Freehand Probe Holder
Ground Blade – Narrow
Ground Blade – Wide
Ground Blade, Narrow
Ground Blade, Wide
Micro-Grabber Pair
1
1
1
1
1
2
1
1
1
PK-ZS-007R and
1
2
2
PK-ZS-007B
Y Lead Adaptor
1
Offset Ground
PK-ZS-016
13
CURRENT PROBES
CURRENT PROBES
Teledyne LeCroy current probes do not require the breaking of a
circuit or the insertion of a shunt to make accurate and reliable
current measurements. Based on a combination of Hall effect and
transformer technology, Teledyne LeCroy current probes are ideal for
making accurate AC, DC, and impulse current measurements.
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
Wide Range of Applications
Teledyne LeCroy current probes are available in a variety of models for a
wide range of applications. The full range of Teledyne LeCroy current probes
includes models with bandwidths up to 100 MHz, peak currents up to
700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often
used in applications such as the design and test of switching power supplies,
motor drives, electric vehicles, and uninterruptible power supplies.
CP030
CP030A
CP031
CP031A
CP150
CP500
DCS025
CA10
High Sensitivity
The CP030A and CP031A provide a high sensitivity of 1 mA/div. This
allows for more precise low current measurements on Teledyne LeCroy
oscilloscopes. When used with HDO high definition oscilloscopes with
HD4096 technology, users will obtain highly accurate, low current waveforms
with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy
®
ProBus connection and require no additional hardware. Along with providing
power, the ProBus connection allows the current probe and oscilloscope to
communicate, resulting in current waveforms automatically displayed on
screen in Amps, and calculated power traces scaled correctly in Watts. This
full integration also allows for Degauss and Autozero functions to be done
directly from the oscilloscope’s user interface.
Deskew Calibration Source
The DCS015 deskew calibration source has both voltage and current time-
aligned signals, which enables the precise deskew of voltage and current
probes. Most voltage probes along with the CP030, CP030A, CP031, and
CP031A are compatible with the DSC025.
Opposite page:
CP031, 30A, 100 MHz Current Probe.
15
CURRENT PROBES
Key Features
ProBus active probe interface withautomatic scaling in A/div
•
Autozero and degauss capabilities built into instrument’s user interface
•
Wide range of input currents and band
•
Teledyne LeCroy
Current Probe
and Adapter
Model Numbers:
CP030
CP030
30 Arms continuous current
–
30 Arms continuous current
–
–
50 Apeak current
50 MHz bandwidth
–
50 Apeak current
–
–
50 MHz bandwidth
1 mA/div sensitivity
–
CP030A
CP031
CP031A
CP150
CP500
DCS025
CA10
CP031
30 Arms continuous current
30 Arms continuous current
–
–
–
–
–
–
–
50 Apeak current
100 MHz bandwidth
50 Apeak current
100 MHz bandwidth
1 mA/div sensitivity
CP500
CP150
500 Arms continuous current
150 Arms continuous current
–
–
–
–
–
–
700 Apeak current
2 MHz bandwidth
500 Apeak current
10 MHz bandwidth
DCS025
Precise deskew of voltage and
–
–
current probes.
Compatible with the CP030, CP030A,
CP031, CP031A, AP015, CP150, and
CP500
16
CURRENT PROBES
CA10 Current Sensor Adapter
The CA10 enables a third-party current measurement device to operate like a Teledyne
LeCroy probe. The CA10 is programmable and customizable to work with third-party
current measurement devices that output voltage or current signals proportional to
measured current. (See page 50 for more information and specifications).
CP030
CP030A
CP031
CP031A
CP150
CP500
Specifications
(CP030-3M)
(CP150-6M)
Electrical Characteristics*
Max. Continuous
30 Arms
150 Arms
500 Arms
2 MHz
Input Current
Bandwidth
50 MHz
10 MHz
(5 MHz)
100 MHz
≤ 3.5 ns
(10 MHz)
Rise Time (typical)
Max. Peak Current
≤ 7 ns
≤ 35 ns
≤ 175 ns
(≤ 35 ns)
(≤ 70 ns)
300 Apeak (non-continuous);
500 Apeak ≤ 30 μs
0.1 V/A & 1 V/A 0.01 V/A
700 Apeak
(non-continuous)
50 Apeak (non-continuous)
Output Voltage
0.1 V/A
–
0.1 V/A & 1 V/A
5 A
0.1 V/A
–
Max Continuous Input Current
5 A
–
at 1 V/A (100mA/div or less)
Offset Range at 1V/A
(100mA/div or less)
Minimum Sensitivity
Low-Frequency Accuracy
AC Noise at 20 MHz BWL
Coupling
–
±5 A
–
±5 A
–
10 mA/div
1 mA/div
10 mA/div
1 mA/div
1%
≤ 150 µA
AC, DC, GND
100 mA/div
≤ 2.5 mA
≤ 150 µA
≤ 2.5 mA
≤ 6.0 mA
≤ 8.0 mA
General Characteristics
Cable Length
1.5 m
(3 m)
2 m
1.5 m
240 g
6 m
(6 m)
Weight
240 g
500 g
260 g
260 g
630 g
(290 g)
(600 g)
Max. Conductor Size
(Diameter)
5 mm
20 mm
Interface
ProBus, 1 MΩ only
Usage Environment
Operating Temperature
Max. Relative Humidity
Max. Altitude
Measurement Category
Indoor
0˚ C to 40˚ C
80%
2000 m
No rated measurement category**
No rated measurement category**
* Electrical Characteristics Guaranteed at 23 °C ±3 °C. Values are based on oscilloscopes with 1 mV/div sensitivity. Numbers will be higher on instruments with lower
sensitivity.
** Not intended for measurements on circuits directly connected to Mains supply or within Measurement Categories II, III, or IV.
CP03x, CP150, and CP500 probes (and long cable versions of these) are compatible with any Teledyne LeCroy oscilloscope with a ProBus interface running
firmware version 4.3.1.1 or greater. CP03xA probes are compatible with most Teledyne LeCroy oscilloscopes with a ProBus interface running X-Stream™
firmware version 7.8.x.x or later.
Ordering Information
Product Description
Product Code
CA10
CA10-QUADPAK
CP030
ProBus Current Sensor Adapter
Set of 4 CA10, ProBus Current Sensor Adapters
30 A; 50 MHz Current Probe – AC/DC; 30 A
; 50 A Peak Pulse, 1.5 meter cable
rms
30A; 10 MHz Current Probe - AC/DC, 30 Arms; 50 A Peak Pulse, 3 meter cable (not EMC compliant)
30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 A ; 50 A Peak Pulse, 1.5 meter cable
CP030-3M
CP030A
rms
30 A; 100 MHz Current Probe – AC/DC; 30 A
; 50 A Peak Pulse, 1.5 meter cable
CP031
rms
30 A; 100 MHz High Sensitivity Current Probe – AC/DC; 30 A
; 50 A Peak Pulse, 1.5 meter cable
rms
CP031A
150 A; 10 MHz Current Probe – AC/DC; 150 A
; 500 A Peak Pulse, 2 meter cable
CP150
rms
150 A; 5 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse, 6 meter cable (not EMC compliant)
500 A; 2 MHz Current Probe – AC/DC; 500 A ; 700 A Peak Pulse, 6 meter cable
CP150-6M
CP500
rms
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
17
DIFFERENTIAL PROBES
DIFFERENTIAL PROBES
Our differential probes are general purpose high-bandwidth probes with
Teledyne LeCroy
high dynamic range and offset. Wide variety of tips and leads are available,
including solder-in, QuickLink solder-in, HiTemp solder-in, browser tip,
square-pin, and SMA/SMP lead.
Differential Probe
Model Numbers:
≤ 1.5 GHz
ZD200
ZD500
ZD1000
ZD1500
AP033
4 GHz - 6 GHz
D410-A-PB2
D420-A-PB2
D400A-AT-PB2
D610-A-PB2
D610-A-PL
D620-A-PB2
D620-A-PL
D600A-AT-PB2
D600A-AT-PL
8 GHz - 13 GHz
D830-PB2
D830-PL
D1330-PL
8 GHz - 30 GHz
DH08-PB2
DH08-PL
DH13-PL
DH16-PL
DH20-PL
DH25-2.92MM
DH30-2.92MM
Opposite page:
DH Series Probes shown with HDA125.
19
≤ 1.5 GHz DIFFERENTIAL PROBES
The ZD Series probes provide wide dynamic range, excellent noise and loading
performance and an extensive set of probe tips, leads, and ground accessories
to handle a wide range of probing scenarios. The low 1 pF capacitance means
this probe is ideal for all frequencies. The ZD Series differential probes provide full
system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower.
Fully Integrated
With the ProBus interface, the ZD500, 1000, and 1500 become an integral part
of the oscilloscope. All probe gain and offset controls are transparent to the user,
making it easier to probe the circuit without concern for which gain setting to
choose. When used with a Teledyne LeCroy digital oscilloscope, no external power
supply is required.
Teledyne LeCroy
≤1.5 GHz
Differential Probe
Model Numbers:
Wide Dynamic Range
The ZD500, 1000, 1500 probes provide transparent probe attenuation so signals are
ZD200
ZD500
ZD1000
ZD1500
AP033
always optimized for the display. The differential range is 18 V with a differential
offset of ±8V and common mode range of ±10 V, making these probes versatile for
every probing application.
p-p
Wide Applications
The wide dynamic range of 16 V and offset range of ±8V suit this probe to a wide
p-p
range of applications and signal types. The ZD differential probes are ideally suited
for Automotive, Serial Data, power, and general purpose use.
ZD200
ZD500
ZD1000
ZD1500
Specifications
Electrical Characteristics
Bandwidth (Warranted)
200 MHz
500 MHz
650 MHz
650 ps
1000 MHz
1200 MHz
375 ps
280 ps
2%
1500 MHz
1700 MHz
270 ps
-
Bandwidth (Typical)
Risetime 10–90% (Typical)
Risetime 20–80% (Typical)
LF Attenuation Accuracy (Warranted)
1.75 ns
-
500 ps
200 ps
1%
Zero Offset (Typical)
5 mV
-
-
(within 15 minutes after autozero)
System Noise (Typical)
1.3 mVrms
1.75 mVrms
Probe Noise Density (Typical)
Input Differential Range (Nominal)
Differential Offset Range (Nominal)
Offset Gain Accuracy (Typical)
Common Mode Range (Nominal)
3 mV
38 nV/rt (Hz)
±8 V (16 Vp-p)
±18 V
rms
± 20 V
-
-
2%
±10 V
± 60 V
Maximum Non-destruct Voltage
30 V
-
(Nominal)
CMRR (Typical)
80 dB @ 60 Hz
50 dB@10 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB 500 MHz
60 dB 50/60 Hz
30 dB 20 MHz
60 dB 50/60 Hz
30 dB 20 MHz
25 dB @ 1000 MHz
25 dB @ 1500 MHz
DC Input Resistance (Nominal)
250 kΩ (Common Mode)
1 MΩ (Differential Mode)
50 kΩ (Common Mode)
120 kΩ (Differential Mode)
Differential Input Capacitance
(Typical)
3.5 pF
< 1.0 pF
20
≤ 1.5 GHz DIFFERENTIAL PROBES
Ordering Information
Product Description
Product Code
200 MHz, 3.5 pF, 1 MΩ Active Differential Probe
500 MHz, 1.0 pF Active Differential Probe, ±8 V
1 GHz, 1.0 pF Active Differential Probe, ±8 V
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD200
ZD1500 / ZD1000 / ZD500 Probe
ZD500
ZD1000
ZD1500
PCF200
Probe Calibration Fixture
PACC-MS001
Hands Free Probe Holder
PACC-ZD004
Tip Saver
Qty: 2
PACC-PT001
Straight Tip
Qty: 4
PACC-ZD005
Swivel Tip Adapter
PACC-ZD006
Small IC Adapter
Qty: 2
PACC-CD008
Spring-loaded
Ground (Short)
Qty: 2
PACC-ZD003
Spring-loaded
Ground (Long)
Qty: 2
PK006-4
Micro-Grabber
Qty: 2
PACC-CL001
Mini-Grabber
Qty: 2
PACC-LD003
Right Angle
Connector (Short)
Qty: 2
PACC-ZD001
Y Lead
Adapter
PACC-ZD002
Solder-In-Lead
Qty: 2
PACC-LD004
Right Angle
Connector (long)
Qty: 2
AP033
Specifications
Bandwidth
Gain
High bandwidth, excellent common-mode rejection ratio
(CMRR) and low noise make these active differential
probes ideal for applications such as disk drive design
and failure analysis, as well as wireless and data
communication design.
500 MHz
x10, x1, ÷10 (÷100 with
plug-on ÷10 attenuator)
DC Accuracy
1% in x1 without
external attenuator
Input Resistance
1 MΩ each input to ground
2 MΩ differential between inputs
Differential Mode Range
±400 mV (x1)
±40 mV (x10)
±4 V (÷10)
±40 V (÷100)
Offset Range
±400 mV (x1, x10)
±4 V (±10)
±40 V (±100)
Common-Mode Range
CMRR
±42 V peak (±10)
+4.2 V peak (±100)
70 Hz 10,000:1 (80 dB)
100 kHz 10,000:1 (80 dB)
1 MHz 1000:1 (60 dB)
10 MHz 100:1 (40 dB)
250 MHz 5:1 (14 dB)
Ordering Information
Product Description
500 MHz Differential Probe
Product Code
AP033
21
4 GHz - 6 GHz DIFFERENTIAL PROBES
Teledyne LeCroy’s WaveLink 4-6 GHz Differential Probes are a general purpose
probing solution with high-input dynamic range and offset range capability. The
range of capabilities is ideal for a variety of high-speed DDR signals where high
dynamic range and large offset requirements are common.
Key Features
4 GHz or 6 GHz models
•
•
•
•
•
•
Up to 5 Vpk-pk dynamic range with low noise
±3 V offset range
Teledyne LeCroy
4 GHz - 6 GHz
Differential Probe
Model Numbers:
Ideal for DDR2, LPDDR2, DDR3
Innovative QuickLink architecture
Wide variety of tips and leads
– Solder-In Lead
– QuickLink Solder-In Lead
– Positioner (Browser) Tip
– Adjustable (Browser) Tip
D410-A-PB2
D420-A-PB2
D400A-AT-PB2
D610-A-PB2
D610-A-PL
D620-A-PB2
D620-A-PL
– Quick Connect Lead
– Square Pin Lead
– Hi-Temp Solder-In Lead
Low loading and high impedance for minimal signal disturbance
Deluxe soft carrying case
•
•
D600A-AT-PB2
D600A-AT-PL
22
4 GHz - 6 GHz DIFFERENTIAL PROBES
D610-A-PB2,
D610-A-PL
D620-A-PB2,
D620-A-PL
D410-A-PB2
D420-A-PB2
D600A-AT-PB2, D400A-AT-PB2
D600A-AT-PL
Bandwidth*
Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
6 GHz
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
6 GHz
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp, Dx10-QC
and Dx10-PT Tips
4 GHz
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp, Dx20-QC
and Dx20-PT Tips
4 GHz
6 GHz
4 GHz
(Probe only, guaranteed)
(System bandwidth, typical)
Dx10-HiTemp
Dx20-HiTemp
5 GHz
5 GHz
Dx10-SP Tip
Dx20-SP Tip
3 GHz
3 GHz
Dx10-QC Tip
Dx20-QC Tip
4 GHz
4 GHz
Dx10-SP Tip
Dx20-SP Tip
3 GHz
3 GHz
Rise Time* (10–90%)
Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
75 ps (typical)
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
75 ps (typical)
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp,
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp,
<75 ps (typical)
56 ps (typical)
<74 nV/√Hz
<112 ps (typical)
84 ps (typical)
<74 nV/√Hz
and Dx10-PT Tips
112 ps (typical)
and Dx20-PT Tips
112 ps (typical)
Dx10-HiTemp
Dx20-HiTemp
90 ps (typical)
90 ps (typical)
Dx10-QC Tip
Dx20-QC Tip
122.5 ps (typical)
122.5 ps (typical)
Dx10-QC Tip
Dx20-QC Tip
122.5 ps (typical)
122.5 ps (typical)
Dx10-SP Tip
Dx20-SP Tip
150 ps (typical)
150 ps (typical)
Dx10-SP Tip
Dx20-SP Tip
150 ps (typical)
150 ps (typical)
Rise Time* (20–80%)
Dx10-SI, Dx10-QL-SI
and Dx10-PT Tips
56 ps (typical)
Dx20-SI, Dx20-QL-SI
and Dx20-PT Tips
56 ps (typical)
Dx10-SI, Dx10-QL-SI,
Dx10-HiTemp,
Dx20-SI, Dx20-QL-SI,
Dx20-HiTemp,
and Dx10-PT Tips
84 ps (typical)
and Dx20-PT Tips
84 ps (typical)
Dx10-HiTemp
Dx20-HiTemp
67.5 ps (typical)
67.5 ps (typical)
Dx10-QC Tip
Dx20-QC Tip
92 ps (typical)
92 ps (typical)
Dx10-QC Tip
Dx20-QC Tip
92 ps (typical)
92 ps (typical)
Dx10-SP Tip
Dx20-SP Tip
113 ps (typical)
113 ps (typical)
Dx10-SP Tip
Dx20-SP Tip
113 ps (typical)
113 ps (typical)
Noise (System)
<36 nV/√Hz
<61 nV/√Hz
<36 nV/√Hz
<67 nV/√Hz
(2.8 mV ) (typical)
rms
(4.8 mV ) (typical)
rms
(2.3 mV ) (typical)
rms
(4.3 mV ) (typical)
rms
(5.8 mV ) (typical) (4.7 mV ) (typical)
rms rms
Referred to input,
6 GHz bandwidth
Referred to input,
6 GHz bandwidth
Referred to input,
4 GHz bandwidth
Referred to input,
4 GHz bandwidth
Referred to input,
Referred to input,
6 GHz bandwidth
4 GHz bandwidth
Input
Input Dynamic Range
(Nominal)
2.5V , ±1.25V
pk-pk
5V
, ±2.5V
pk-pk
2.5V
, ±1.25V
pk-pk
5V
, ±2.5V
pk-pk
4.8V , ±2.4V
pk-pk
Input Common Mode Voltage
±4 V
±2.4 Vmax
n/a
Range (Nominal)
Input Offset Voltage Range
Non-destructive
Input Range (Nominal)
Attenuation
DC Input Resistance
(Nominal)
±3 V Differential (nominal)
±20 V
±18 V
1.7X / 1.0X (nominal)
3.2X / 1.9X (nominal)
200 kΩ Differential
50 kΩ Common Mode
1.7X / 1.0X (nominal)
3.2X / 1.9X (nominal)
2.5X
4 kΩ Differential
1 kΩ Common Mode
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth
†
Through entire frequency range
Product Description
Product Code Product Description
Accessories
Product Code
Complete Differential Probes
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
4 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
4 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
6 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
6 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1),
Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1)
6 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1),
Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1)
4 GHz ProBus2 Differential Probe with Adjustable Tip
D410-A-PB2 Probe Deskew and Calibration Test Fixture
TF-DSQ
D410-A-PL
Calibration Options
NIST Calibration for D410-A. Includes test data.
D410-A-CCNIST
D420-A-CCNIST
D610-A-CCNIST
D620-A-CCNIST
D400A-AT-CCNIST
D600A-AT-CCNIST
D420-A-PB2
NIST Calibration for D420-A. Includes test data.
NIST Calibration for D610-A. Includes test data.
NIST Calibration for D620-A. Includes test data.
D420-A-PL
NIST Calibration for D400A-AT. Includes test data.
NIST Calibration for D600A-AT. Includes test data.
D610-A-PB2
D610-A-PL
Replacement Parts
Single replacement QuickLink Solder-In Tip
9-pack of replacement QuickLink Solder-In Tip
Replacement Dx10-SI 4 & 6 GHz Solder-In Lead with
Qty. 5 Spare Resistors.
QL-SI-1Pack
QL-SI-9Pack
Dx10-SI
D620-A-PB2
D620-A-PL
Replacement Dx20-SI 4 & 6 GHz Solder-In Lead with
Dx20-SI
D400A-AT-PB2
D600A-AT-PB2
D600A-AT-PL
Qty. 5 Spare Resistors.
6 GHz ProBus2 Differential Probe with Adjustable Tip
6 GHz ProLink Differential Probe with Adjustable Tip
Replacement Dx10-QC 4 & 6 GHz Quick Connect Lead
Replacement Dx20-QC 4 & 6 GHz Quick Connect Lead
Replacement Dx10-SP 4 & 6 GHz Square Pin Lead
Replacement Dx20-SP 4 & 6 GHz Square Pin Lead
Replacement SI Resistor Kit for Dx10/Dx20 - Kit of 20
Replacement QC Resistor Kit for Dx10/Dx20 - 2 kits of 20
Qty. 4 Replacement Pogo Pin Tips and Qty. 2
Replacement Sockets for Dx10-PT and
Dx10-QC
Dx20-QC
Dx10-SP
Dx20-SP
PKxx0-SI
Positioner Tip (Browser) Kits
WaveLink Dx10-PT Adjustable Positioner Tip Kit.
For use with Dx10 amplifiers.
WaveLink Dx20-PT Adjustable Positioner Tip Kit.
For use with Dx20 amplifiers.
Dx10-PT-KIT
Dx20-PT-KIT
PKxx0-QC
Dxx0-PT-TIPS
Dx20-PT Adjustable Positioner Tips.
QuickLink Solder-In Tip Set
Replacement Probe Tip Holder Kit
PK600ST-3
PK600ST-4
Dxx0-PT-TAPE
QuickLink Solder-In starter pack for use with Dx10 amplifier.
Dx10-QL-3SI
Dx20-QL-3SI
Replacement Platform/Cable Assembly Mounting Kit
Quantity 1 Package of Black Adhesive Pads (10/pkg) and
Quantity 1 Package of White Adhesive Pads (10/pkg)
Quantity 1 Package of Adhesive Probe Connection Guides
(200 individual guides/package)
Includes one QuickLink adapter and three QL-SI tips.
QuickLink Solder-In starter pack for use with Dx20 amplifier.
Includes one QuickLink adapter and three QL-SI tips.
Dxx0-PT-GUIDES
23
8 GHz - 13 GHz DIFFERENTIAL PROBES
The WaveLink Differential Probe Series is a 8-13 GHz bandwidth active differential
probe series with high input dynamic range, a large offset capability, and a wide
variety of tips and leads available for different applications.
Key Features
Choice of 8 or 13 GHz bandwidth models
•
3.5 Vpk-pk dynamic range
•
±4 V offset range
•
Ideal for DDR3, DDR4, LPDDR3
•
Innovative QuickLink architecture
Teledyne LeCroy
8 GHz - 13 GHz
Differential Probe
Model Numbers:
•
Wide variety of tips and leads
– Solder-In Lead
•
– QuickLink Solder-In Lead
– Positioner (Browser) Tip
– SMA/SMP Lead
– Square Pin Lead
– Hi-Temp Solder-In Lead
D830-PB2
D830-PL
D1330-PL
Low loading and high impedance for minimal signal disturbance
•
Deluxe soft carrying case
•
SMA/SMP lead set accessory does not require purchase of a different amplifier
•
24
8 GHz - 13 GHz DIFFERENTIAL PROBES
D830-PB2, D830-PL
D1330-PL
Dxx30-SI and Dxx30-SMA-SMP Tips
13 GHz
Bandwidth*
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
8 GHz
(Probe only, guaranteed)
(System bandwidth, typical)
Dxx30-PT and Dxx30-HiTemp Tips
Dxx30-SP Tip
10 GHz
3 GHz
Dxx30-QL-SI Tip
8 GHz
Dxx30-SP Tip
3 GHz
Rise Time* (10–90%)
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
50 ps (typical)
Dxx30-SI and Dxx30-SMA-SMP Tips
35 ps (typical)
Dxx30-PT and Dxx30-HiTemp Tips
Dxx30-SP Tip
132 ps (typical)
40 ps (typical)
Dxx30-QL-SI Tip
50 ps (typical)
Dxx30-SP Tip
132 ps (typical)
Rise Time* (20–80%)
Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP,
Dxx30-HiTemp, and Dxx30-PT Tips
37.5 ps (typical)
Dxx30-SI and Dxx30-SMA-SMP Tips
26 ps (typical)
Dxx30-PT and Dxx30-HiTemp Tips
Dxx30-SP Tip
100 ps (typical)
30 ps (typical)
Dxx30-QL-SI Tip
37.5 ps (typical)
Dxx30-SP Tip
100 ps (typical)
Noise (Probe)
<48 nV/√Hz (4.3 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<52 nV/√Hz (4.6 mVrms) (typical)
Referred to input, 8 GHz bandwidth.
<48 nV/√Hz (5.5 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
<52nV/√Hz (5.9 mVrms) (typical)
Referred to input, 13 GHz bandwidth.
Noise (System)
Input
Input Dynamic Range
Input Common Mode Voltage Range
Input Offset Voltage Range
Non-destructive Input Range
Attenuation
3.5Vpk-pk, ±1.75V (nominal)
±5 V (nominal)
±4 V Differential (nominal)
±15 V (nominal)
3.75x (nominal)
DC Input Resistance (nominal)
200 kΩ Differential
50 kΩ Common mode
>250 Ω Differential through entire frequency range using SI tip
Impedance (Zmin, typical)
Impedance (mid-band, typical)
Dxx30-SI, Dxx30-QL-SI, and Dxx30-HiTemp Tips
470 Ω at 4 GHz, 320 Ω at 6 GHz, 260 Ω at 8 GHz, 250 Ω at 9 GHz, 260 Ω at 10 GHz, 350 Ω at 13 GHz
Dxx30-PT Tip
155 Ω at 4 GHz, 210 Ω at 6 GHz, 140 Ω at 8 GHz, 80 Ω at 9 GHz, 40 Ω at 10 GHz
CMRR
58 dB DC / 100 Hz
38 dB to 10 MHz
30 dB to 3 GHz
20 dB to 8 GHz
(typical)
* All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth
Product Description
Product Code
Product Description
Product Code
Complete Differential Probes
Accessories
8 GHz ProBus2 Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
8 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
13 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip
(Qty. 2) and Dxx30-SP Square Pin (Qty. 1)
D830-PB2
D830-PL
Probe Deskew and Calibration Test Fixture
Calibration Options
NIST Calibration for D830. Includes test data.
NIST Calibration for D1330. Includes test data.
TF-DSQ
D830-CCNIST
D1330-CCNIST
D1330-PL
Replacement Parts
Single replacement QuickLink Solder-In Tip
9-pack of replacement QuickLink Solder-In Tip
Replacement Dxx30-SP 8-13 GHz Square Pin Lead
Replacement Dxx30-SI 8-13 GHz Solder-In Lead
with Qty. 5 Spare Resistors.
QL-SI-1Pack
QL-SI-9Pack
Dxx30-SP
Positioner Tip (Browser) Kits
WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable
Positioner Tip Kit. For use with Dxx30 amplifiers.
Dxx30-PT-KIT
Dxx30-SI
Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI
Dxx05-SI-RESISTORS
Dxx0-PT-TIPS
QuickLink Solder-In Tip Set
and Dxx30-SI Solder-In Tip - Kit of 5
QuickLink Solder-In starter pack for use with Dxx30 amplifier.
Dxx30-QL-3SI
Dxx30-HiTemp
Includes one QuickLink adapter and three QL-SI tips.
Qty. 4 Replacement Pogo Pin Tips and
Qty. 2 Replacement Sockets for Dx10-PT, Dx20-PT,
and Dxx30-PT Adjustable Positioner Tips.
Replacement Probe Tip Holder Kit
Hi-Temp Lead Set
WaveLink Temperature Extension Cables for Dxx30.
Includes set of Matched 30” High Temperature Cables (Qty. 1)
and solder-in lead set (Qty. 1).
PK600ST-3
PK600ST-4
Dxx0-PT-TAPE
Replacement Platform/Cable Assembly Mounting Kit
Quantity 1 Package of Black Adhesive Pads (10/pkg) and
Quantity 1 Package of White Adhesive Pads (10/pkg)
Quantity 1 Package of Adhesive Probe Connection Guides
(200 individual guides/package)
Dxx05-PT-GUIDES
SMA/SMP Lead Set
SMA/SMP lead set for use with Dxx30 amplifiers.
Includes a set of SMA leads, SMP leads, pair of DC blocks
and SMA finger wrenches.
Dxx30-SMA-SMP-LEADS
25
8 GHz - 30 GHz DIFFERENTIAL PROBES
The DH series of 8 to 30 GHz active differential probes provides high input
dynamic range, large offset capability, low loading and excellent signal
fidelity with a range of connection options.
Key Features
Bandwidth models from 8 GHz to 30 GHz
•
Low loading and high impedance for minimal signal disturbance
•
Wide variety of tips:
•
– Standard and high-sensitivity 30 GHz solder-in tips
– High-temperature solder-in tip with 1-meter lead
– QuickLink adapter for mixed-signal probing
– Handheld browser tip
Teledyne LeCroy
8 GHz - 30 GHz
Differential Probe
Model Numbers:
Built-in tip identification for simple setup and precise signal reproduction
•
•
DH08-PB2
DH08-PL
Ideal for debug and validation of:
DH13-PL
– DDR3/LPDDR3
– DDR4/LPDDR4
– DDR5/LPDDR5
DH16-PL
DH20-PL
DH25-2.92MM
DH30-2.92MM
– Other high-speed serial interfaces
LabMaster 10 Zi-A Oscilloscope
WaveMaster/SDA 8 Zi-B Oscilloscope
WavePro HD Oscillosope
LabMaster MCMZi-A Master Control Module
1
2
3
4
LPA-PB2
LPA-2.92MM
DH08-PL
DH25-2.92MM
DH30-2.92MM
DH13-PL
DH16-PL
DH20-PL
DH08-PB2
DH-SI-HS
DH-SI
DH-PT
DH-HITEMP
DH-QL
26
8 GHz - 30 GHz DIFFERENTIAL PROBES
DH08
DH13
DH16
DH20
DH25
DH30
Bandwidth
Bandwidth (probe only)
8 GHz
8 GHz
8 GHz
8 GHz
8 GHz
13 GHz
13 GHz
13 GHz
13 GHz
8 GHz
16 GHz
16 GHz
16 GHz
16 GHz
8 GHz
20 GHz
20 GHz
16 GHz
16 GHz
8 GHz
25 GHz
25 GHz
16 GHz
16 GHz
8 GHz
30 GHz
30 GHz
16 GHz
16 GHz
8 GHz
Bandwidth with DH-SI or DH-SI-HS tip
Bandwidth with DH-HITEMP tip
Bandwidth with DH-PT browser
Bandwidth with DH-QL adapter and
QL-SI tip
Rise Time*
Rise Time (10-90%)
Rise Time (20-80%)
Probe noise (referred to input)*
With DH-SI-HS tip
56 ps
37.5 ps
34.5 ps
23 ps
28 ps
19 ps
22.5 ps
15 ps
18 ps
12 ps
15 ps
10 ps
2.1 mV
3.5 mV
2.2 mV
3.8 mV
2.3 mV
4.2 mV
2.6 mV
4.6 mV
2.9 mV
4.8 mV
3.2 mV
5.0 mV
rms
rms
rms
rms
rms
rms
rms
rms
rms
rms
rms
rms
With all other tips
Probe noise density (referred to input)
With DH-SI-HS tip
18 nV/rt(Hz)
With all other tips
30 nV/rt(Hz)
Input
Input Dynamic Range
With DH-SI-HS tip
2.0 Vpp (±1.0 V)
With all other tips
3.5 Vpp (±1.75 V)
±5.0 V
Input Common Mode Voltage Range
Input Offset Voltage Range
Non-destructive Input Range
Attenuation
±4.0 V
±16 V
With DH-SI-HS tip
With all other tips
Attenuation Accuracy
DC Input Resistance (nominal)
Differential
1.8x / 3.2x (selected automatically by oscilloscope software)
3.2x / 5.8x (selected automatically by oscilloscope software)
±2%
200 kΩ differential
50 kΩ differential
Common mode
Input Resistance > 10 kHz (typical)
With DH-SI-HS tip
With all other tips
1100 Ω differential
2100 Ω differential
Environmental
Temperature
Non-operating
Operating (DH-HITEMP tip)
-40 °C to 70 °C
-40 °C to 125 °C
* All Rise Time and Probe noise measurements are made using a full-bandwidth solder-in tip, and with an oscilloscope bandwidth greater than or equal to the probe bandwidth. When using other tips, rise time
and noise measurements correspond to those of the equivalent-bandwidth probe model with a DH-SI tip.
Product Description
Product Code
Product Description
Calibration Options
3-year warranty
Product Code
Differential Probes (tips not included)
8 GHz differential probe with ProBus2 interface
8 GHz differential probe with ProLink interface
13 GHz differential probe with ProLink interface
16 GHz differential probe with ProLink interface
20 GHz differential probe with ProLink interface
25 GHz differential probe with 2.92 mm interface
30 GHz differential probe with 2.92 mm interface
DH08-PB2
DH08-PL
DH08-W3, DH13-W3,
DH16-W3, DH20-W3,
DH25-W3, DH30-W3
DH08-W5, DH13-W5,
DH16-W5, DH20-W5,
DH25-W5, DH30-W5
DH08-C3, DH13-C3,
DH16-C3, DH20-C3,
DH25-C3, DH30-C3
DH08-C5, DH13-C5,
DH16-C5, DH20-C5,
DH25-C5, DH30-C5
DH08-T3, DH13-T3,
DH16-T3, DH20-T3,
DH25-T3, DH30-T3
DH08-T5, DH13-T5,
DH16-T5, DH20-T5,
DH25-T5, DH30-T5
DH13-PL
5-year warranty
DH16-PL
DH20-PL
DH25-2.92MM
DH30-2.92MM
3-year annual NIST calibration
Solder-in Tips
5-year annual NIST calibration
DH series solder-in tip, 30 GHz BW, 3.5 Vpp range
DH-SI
DH-SI-HS
DH series high-sensitivity solder-in tip, 30 GHz BW,
2.0 Vpp range
3-year warranty with annual NIST calibration
5-year warranty with annual NIST calibration
NIST traceable calibration with test data
Positioner (Browser) Tips
DH series PT browser tip, 16 GHz BW, 3.5 Vpp range
DH-PT
High-temperature Tips
DH08-CCNIST,
DH13-CCNIST,
DH16-CCNIST,
DH20-CCNIST,
DH25-CCNIST,
DH30-CCNIST
DH series high-temperature solder-in tip, 16 GHz BW,
DH-HITEMP
3.5 Vpp range
QuickLink Adapters and Kits
DH series QuickLink adapter, 8 GHz BW
DH series QuickLink adapter kit with 3 x QL-SI tips
DH-QL
DH-QL-3SI
Accessories
Replacement Parts
ProLink to 2.92 mm adapter with probe power and
LPA-2.92
Replacement SI resistor kit for DH-SI and
DH-SI-RESISTORS
communication pass through
DH-SI-HS solder-in tips
2.92 mm to ProLink adapter with probe power and
communication pass through
L2.92A-PLINK
27
HIGH VOLTAGE DIFFERENTIAL PROBES
HIGH VOLTAGE DIFFERENTIAL PROBES
High voltage differential probes provide high CMRR over a broad frequency
Teledyne LeCroy
High Voltage
range to simplify the measurement challenges found in noisy, high common-
mode power electronics environments. The probe’s design is easy-to-use
and enables safe, precise high voltage floating measurements.
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3220
HVD3605A
AP031
Opposite page:
HVD3000A Series High Voltage Differential Probes
with a WaveRunner 8000HD High Definition Oscilloscope.
29
HIGH VOLTAGE DIFFERENTIAL PROBES
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3220
HVD3605A
The HVD3000A series high voltage differential probes provide high CMRR over a
broad frequency range to simplify the measurement challenges found in noisy, high
common-mode power electronics environments. The probe’s design is easy-to-use
and enables safe, precise high voltage floating measurements.
Key Features
1 kV, 2 kV, 6 kV CAT safety rated models
•
•
•
Widest differential voltage ranges available
Exceptional common-mode rejection ratio (CMRR)
across a broad frequency range
1% gain accuracy
•
•
•
•
•
•
High offset capability at both high and low attenuation
AC and DC coupling
ProBus active probe interface with automatic scaling
AutoZero with auto disconnect switch
Wide oscilloscope compatibility
30
HIGH VOLTAGE DIFFERENTIAL PROBES
HVD3106A/
HVD3206A/
HVD3102A
25 MHz
HVD3106A-6M
HVD3206A-6M
HVD3220
400 MHz
HVD3605A
100 MHz
120 MHz/
80 MHz
120 MHz/
80 MHz
Bandwidth
1500 V
1500 V
2000 V
7000 V
(DC + peak AC)
(7600 V maximum
typical measurable
before saturation)
8485 V (DC + peak AC)
CAT I
Differential
Voltage
(DC + peak AC)
(DC + peak AC)
(DC + peak AC)
(1750V maximum
typical measurable
before saturation)
(2000V maximum typical
measurable before saturation)
Range
1000 V
CAT III
rms
2000 V (DC + peak AC) CAT I
1500 Vdc CAT III
Max Safe
Input
1000 Vrms CAT III
6000 V
CAT I
rms
Voltage
1000 V
CAT III
rms
1000 V CAT III
dc
Gain
1%*
2.25 meters/
6.8 meters
Accuracy
2.25 meters
2.25 meters/
6.8 meters
2 meters
6.8 meters
Cable Length
Included Tip
Accessories
*Up to 0.35% on HVD3220
Yes
HVD310xA-NOACC
HVD310xA / 310xA-6M
HVD3206A / 3206A-6M
HVD3220
HVD3605A
31
HIGH VOLTAGE DIFFERENTIAL PROBES
Teledyne LeCroy
High Voltage
Differential Probe
Model Numbers:
HVD3102A
HVD3106A
HVD3106A-6M
HVD3206A
HVD3206A-6M
HVD3220
HVD3605A
AP031
Ordering Information
Product Description
Product Code
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable
1 kV, 80 MHz High Voltage Differential Probe with 6 m cable
1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories
1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories
2 kV, 120 MHz High Voltage Differential Probe with 2 m cable
2 kV, 80 MHz High Voltage Differential Probe with 6 m cable
HVD3102A
HVD3106A
HVD3106A-6M
HVD3102A-NOACC
HVD3106A-NOACC
HVD3206A
HVD3206A-6M
HVD3220
2 kV, 400 MHz High Voltage Differential Probe with 2 m cable
6 k 100 MHz High Voltage Differential Probe with 6 m cable
HVD3605A
PK-HV-001
V,
High Voltage Replacement Accessories Kit (Includes 2 each): High Bandwidth 4 mm Probe Tip Adapters,
Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals
32
HIGH VOLTAGE DIFFERENTIAL PROBES
AP031
The AP031 is a low cost, battery operated active
differential probe intended for measuring higher
voltages. The differential techniques employed
permit measurements to be taken at two points in a
circuit without reference to the ground, allowing the
oscilloscope to be safely grounded without the use
of opto-isolators or isolating transformers.
Key Features
Safe floating measurements
•
15 MHz bandwidth
•
700 V maximum input voltage
•
Works with any 1 MΩ input oscilloscope
•
Specifications
Attenuation
÷10 / ÷100
Bandwidth
15 MHz
Input R
4 MΩ
Differential Mode Range
Common Mode Range
CMRR
±70 V / ±700 V DC + Peak AC
±700 V DC + Peak AC
86 dB @ 50 Hz
56 dB @ 200 kHz
Power Requirements: four AA batteries
Ordering Information
Product Description
Product Code
700 V, 15 MHz Differential Probe (÷10, ÷100)
AP031
33
HIGH VOLTAGE PROBES
HIGH VOLTAGE PROBES
High voltage probes are suitable for a wide range of applications where
high-voltage measurements must be made safely and accurately. There
are several fixed attenuation probes covering a range from 1 kV to 6 kV
and varying transient overvoltage ratings. All of these high voltage probes
feature a spring loaded probe tip and a variety of standard accessories
to make probing high voltages safe and easy. Additionally, all of the high
voltage probe have a probe sense pin to automatically configure the
oscilloscope for use with the probe.
Teledyne LeCroy
High Voltage Probe
Model Numbers:
HVP120
PPE4KV
PPE5KV
PPE6KV
Opposite page:
PPE Series High Voltage Probe with a WaveSurfer 4000HD
High Definition Oscilloscope.
35
HIGH VOLTAGE PROBES
The HVP120 is a high voltage passive probe designed for probing up to
1,000 Vrms and capable of handling up to 6,000 V peak transients. Its
fast rise time and excellent frequency response make it suitable for a wide
variety of high voltage measurement applications. The HVP120 features
a spring loaded probe tip and a variety of standard accessories to make
probing high voltages safe and easy.
Electrical Characteristics
Bandwidth
400 MHz
Risetime (10% - 90%)
Maximum Input Voltage*
Measurement Category II
Measurement Category I
900 ps (typical)
1000 Vrms
4000V Transient Overvoltage at 1000 Vrms
6000V Transient Overvoltage at 0 Vrms
Teledyne LeCroy
High Voltage Probe
Model Number:
Pollution Degree*
Input Capacitance
Compensation Range
Attenuation Ratio
2
7.5 pF (typical)
10 pF - 50 pF (typical)
100:1 ± 2%
HVP120
Environmental
Temperature (Operating)
Temperature (Non-Operating)
Humidity (Operating)
0°C to 50°C
-40°C to 71°C
80% RH (Non-Condensing) up to 31°C,
decreasing linearly to 40% RH at 50°C
Altitude (Operating)
Altitude (Non-Operating)
up to 2,000 m
up to 15,000 m
General Characteristics
Weight (probe)
Cable Length
67 g (0.15 lbs)
2 m (6.56 ft)
Probe Tip Diameter
* As defined in IEC 61010-031
5 mm (0.20 inches)
Ordering Information
Product Description
Product Code
HVP120
400 MHz, High Voltage Passive Probe
High Voltage Replacement Accessories Kit
PK-HV-002
Replacement Accessories
One of each of the following accessories are included with the HVP120. Replacement quantities are listed below.
Coding Rings (set) 4 Colors (Qty 3 also included standard)
Ground Lead 22 cm to 4 mm Banana plug (Qty 1)
Solid Tip 0.8 mm (Qty 5)
Spring Tip 0.8 mm (Qty 5)
BNC Adapter 5.0-L (Qty 1)
Insulating Cap 5.0-L (Qty 1)
Protection Cap 5.0-L (Qty 1)
Sprung Hook 5.0-L (Qty 1)
Adjustment Tool T (Qty 1)
PK1-5MM-106
PK1-5MM-122
PK1-5MM-125
PK1-5MM-126
PK1-5MM-127
PK1-5MM-128
PK1-5MM-129
PK1-5MM-130
PK1-5MM-131
PK1-5MM-132
PK1-5MM-133
PK1-5MM-134
Flexible Adapter 5.0-L (Qty 1)
Safety Alligator Clip red (Qty 1)
Ground Lead 22 cm (Qty 1)
36
HIGH VOLTAGE PROBES
The PPE series includes four fixed-attenuation probes covering a range from
2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for
voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically
rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation
of the probe.
PPE High-Voltage Probes Selection Guide Specifications
Types
Bandwidth Input R Input C Attenuation Maximum
Probe Cable
Encoding
(MHz)
400
(Ω)
(pF)
< 6
< 6
< 6
Voltage
4 kV
PPE4kV*
PPE5kV*
PPE6kV*
50 M
50 M
50 M
÷100
÷100
Yes
Yes
Yes
2 m
2 m
2 m
400
5 kV
400
÷1000
6 kV
Teledyne LeCroy
High Voltage Probe
Model Numbers:
PPE4KV
PPE5KV
PPE6KV
Trimming Tool
Security Ground Lead
Ground Lead
(22 cm)
Flexible 4 mm
Security Adapter
BNC Adapter
Insulating Tip
IC Insulating Tip
Straight Tip
(0.8 mm)
Spring Contact Tip
(0.8 mm)
Sprung Hook
Crocodile Clip (Black)
Crocodile Clip (Red)
Ordering Information
Product Description
Product Code
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 4 kV max. Voltage DC and Peak AC
÷100; 400 MHz; 50 MΩ High-Voltage Probe, 5 kV max. Voltage DC and Peak AC
PPE4KV
PPE5KV
÷1000; 400 MHz; 50 MΩ High-Voltage Probe, 6 kV max. Voltage DC and Peak AC
PPE6KV
Accessory Kit for PPE1.2kV, 2kV, 4kV, 5kV, and 6kV
Sprung Hook (red)
Ground Lead (22 cm)
Crocodile Clip
PK103
PK103-1
PP005-GL22
PK30x-2
Probe Tip to BNC Adapter
Spring Tip (0.8 mm)
Rigid Tip V2A
PP005-BNC
PP005-ST8
PP005-RT
Supplied with probe:
* Probe Kit: Trimming tool, ground lead, rigid tip, IC insulator, BNC adapter, tip insulator, spring hook, red crocodile clip.
4 mm safety ground lead, and green/yellow crocodile clip.
37
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
38
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
Teledyne LeCroy
The HVFO is an affordable, optimally designed probe for measurement of
Probe Adapter
small signals floating on an HV bus in power electronics designs or for
Model Numbers:
EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpass-
HVFO108
es the measurement capabilities and signal fidelity of both conventional
HV differential probes and acquisition systems that rely on galvanic high
voltage isolation. Furthermore, it mitigates the need to rely on dangerous
test setups that require floating the oscilloscope and probe.
Opposite page:
High Voltage Fiber Optically-isolated Probe with a
WaveRunner 8000HD High Definition Oscilloscope.
39
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
The HVFO is an affordable, optimally designed probe for measurement of small
signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD,
and RF immunity testing sensor monitoring. It far surpasses the measurement
capabilities and signal fidelity of both conventional HV differential probes and
acquisition systems that rely on galvanic high voltage isolation. Furthermore,
it mitigates the need to rely on dangerous test setups that require floating the
oscilloscope and probe.
Key Features
150 MHz bandwidth
Teledyne LeCroy
High Voltage Fiber
35 kV common-mode voltage rating (fiber optic isolation)
Optically-isolated Probe
Model Number:
HVFO108
Superior Noise and Rejection
140 dB CMRR
Low loop inductance
Low attenuation
•
•
•
Optical isolation reduces adverse loading of DUT
Selectable tips from ±1V to ±40V
Applications
Upper-side gate drive signal measurements
Floating control signal or sensor voltage measurements
EMC, EFT, ESD, and RF immunity testing and system optimization
Any small signal measurements with high common-mode voltage
•
•
•
•
40
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES
Electrical
Bandwidth
150 MHz (typical, with tip attached)
Rise Time (10-90%)
Input Dynamic Range
3.3 ns (typical)
±1V, ±5V, ±10V, ±20V, ±40V (DC+peak AC) respectively with 1X, 5X, 10X, 20X or 40X attenuating tips.
All tips are purchased as accessories (none are included with HVFO108 probe).
Maximum Non-destruct Voltage 5 times the operating voltage rating (tip dependent)
Common Mode Voltage Range
Maximum Input Voltage to Earth ±35 kV (DC+Peak AC) (not for hand-held use, with adequate spacing between probe components and earth ground)
Maximum Safe Input Voltage
Offset
±35 kV (DC+Peak AC) (not for hand-held use, with adequate spacing between probe components and earth ground)
For hand-held use, 30 Vrms / 60 Vdc per IEC/EN 61010-031:2015
Offset capability determined by oscilloscope offset available in a given gain (V/div) setting after accounting for total
probe attenuation (total probe attenuation is twice the tip attenuation).
Sensitivity
10 mV/div to 1 V/div (1X tip), 50 mV/div to 5 V/div (5X tip), 100 mV/div to 10 V/div (10X tip), 200 mV/div to 20 V/div (20X
tip), 400 mV/div to 40 V/div (40X tip)
Gain Accuracy
Input Impedance
Input/Output Coupling
Interface
Cable Length
Battery
2.5% (typical), 4% (guaranteed)
1 MΩ || 34 pF (1X tip); 5 MΩ || 26 pF (5X tip); 8 MΩ || 23 pF (10X tip); 10 MΩ || 22 pF (20X tip); 10 MΩ || 22 pF (40X tip)
DC only
ProBus
1.25 m (4.1 feet) from input lead to oscilloscope connection (using included 1 meter fiber optic cable)
6 hour battery life (typical). 2.5 hour re-charge time (typical, with user-supplied dedicated USB charger).
5 hour re-charge time (typical) using supplied USB charging cable connected to oscilloscope USB port
Noise, Rejection, and Electromagnetic Compatibility (EMC)
CMRR (typical)
140 dB (100 Hz), 120 dB (to 1 MHz), 85 dB (to 10 MHz),
60 dB (to 60 MHz), 35 dB (to 150 MHz)
Noise (Probe only)
7 mVrms (1X tip), 35 mVrms (5X tip), 70 mVrms (10X tip), 140 mVrms (20X tip), 280 mVrms (40X tip)
570 nV/√Hz
8 kV contact discharge and 10 kV air discharge per IEC61000-4-2, criteria A
Noise Density (Probe only)
Electrostatic Discharge (ESD)
Immunity
Radiated RF Electromagnetic
Field Immunity
Immunity to Conducted
Disturbance Induced by
RF Fields
25 V/m (80 MHz to 2.7 GHz) per IEC61000-4-3, criteria A
10 V/m (150 kHz to 80 MHz) per IEC61000-4-6, criteria A
Environmental
Temperature
Humidity
10°C to 40°C (operating), -20°C to 70°C (non-operating)
5% to 80% RH (non-condensing) up to 30°C, decreasing linearly to 45% RH at 50°C (operating)
5% to 95% RH (non-condensing), 80% RH above 30°C, 45% RH above 50°C (non-operating)
Up to 3000 m (operating), 10,000 m (non-operating)
2, Indoor Use Only
Altitude
Pollution Degree
Certifications
CE Declaration of Conformity
Low Voltage Directive 2014/35/EU (IEC/EN 61010-031:2015
EMC Directive 2014/30/EU (IEC/EN 61326-1:2013)
RoHS2 Directive 2011/65/EU
Ordering Information
Product Description
Product Code
High Voltage Fiber Optically-isolated Probe Models and Accessories
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case, Qty. 1 Amplifier/Modulating Transmitter, Qty. 1
Demodulating Receiver, Qty. 1 1m Fiber Optic Cable, Qty. 1 USB Charging Cable, Qty. 1 Micro-gripper set.
Attenuating Tips must be ordered separately.
HVFO108
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory
HVFO100-1X-TIP-U
HVFO100-5X-TIP-U
HVFO100-10X-TIP-U
HVFO100-20X-TIP-U
HVFO100-40X-TIP-U
HVFO-1M-FIBER
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
1m Spare Fiber Optic Cable Accessory
6m Fiber Optic Cable Accessory
NIST Traceable Calibration Certificate
HVFO-6M-FIBER
HVFO108-CCNIST
41
OPTICAL-TO-ELECTRICAL CONVERTERS
OPTICAL-TO-ELECTRICAL CONVERTERS
Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters
Teledyne LeCroy
Optical Probe
are designed for measuring optical communications signals. Their broad
wavelength range and multi-mode input optics make these devices ideal for
applications including Ethernet, Fibre Channel, and ITU telecom standards.
Available to support optical data rates up to 11.3 Gb/s with reference
receivers, or slightly higher without reference receivers.
Model Numbers:
OE6250G-M
OE695G
OE425
OE455
OE525
These wide- band multi-mode optical-to-electrical converters are designed
for measuring optical communications signals. They connect to Teledyne
LeCroy real-time oscilloscopes and provide capability for physical layer
signal assessment using a variety of oscilloscope tools, such as
SDAIII-CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis,
mask testing, serial triggering and decoding, and other compliance and
debug tools. Maximum data rate test capability is >11.317 Gb/s with
reference receiver, or 12.5 Gb/s without.
OE555
Opposite page:
OE6250G-M Optical Probe with a LabMaster 10 Zi-A oscilloscope.
43
OPTICAL-TO-ELECTRIC
Teledyne LeCroy
Optical Probe
Model Numbers:
OE6250G-M
OE695G
OE425
OE455
OE525
OE555
OE6250G-M
The OE6250G optical-to-electrical converter enables optical signal measure-
ment of intensity-modulated signals up to 28 Gbaud and beyond on LabMaster
or WaveMaster series real-time oscilloscopes. As a fully calibrated module, the
OE6250G-M integrates seamlessly into the oscilloscope software to give optical
intensity measurement straight out of the box. Teledyne LeCroy’s extensive tool-
set includes powerful analysis tools for NRZ, PAM4, and other signal types, and
enables custom signal processing and reference receiver implementation.
Key Features
Optical-to-electrical converter for
intensity-modulated signals to 28
Gbaud and higher
•
OE6250G-M Specifications
Typical
Analog Bandwidth
25 GHz (Bessel-Thomson response mode),
36 GHz (Flatness response mode)
830nm - 1600nm
850nm, 1310nm, 1550nm
-80 V/W
– Up to 25 GHz bandwidth with
a 4th-order Bessel-Thomson
frequency
response
– Up to 36 GHz bandwidth with a flat
frequency response
Wavelength Range
Calibration Wavelengths
Conversion gain at 850nm
Conversion gain at 1310nm
Conversion gain at 1550nm
Electrical output coupling
5% compression point at 1550nm
Noise measured up to 50GHz
Optical Return Loss
-125 V/W
-125 V/W
DC coupled
4 mW (minimum)
500 uV RMS
19 dB
DC-coupled detector for accurate
signal reproduction with a real-time
oscilloscope
•
Polarization dependent loss at 1550 nm
RF impedance
Fiber (core/cladding)
RF connector
Optical Connector
0.1 dB
50 Ω
50/125 µm
2.92 mm
FC/PC or SC/PC
Fully calibrated and integrated
•
•
•
Note: All specifications subject to change without notice.
50/125 µm multi-mode fiber input
Ideal for Eye Mask, Extinction Ratio,
and Optical Modulation Amplitude
(OMA) testing
44
OPTICAL-TO-ELECTRICAL CONVERTERS
OE695G
OE425/OE455/OE525/OE555
The OE695G wide-band optical-to-electrical converter is
ideal for measuring optical datacom and telecom signals
with data rates from 622 Mb/s to 12.5+ Gb/s. Connection
to a real-time Teledyne LeCroy oscilloscope is through the
2.92 mm interface, with a provided adapter to connect to
ProLink interfaces.
The O/E converters contain calibration data that can be
used to create optical reference receivers for SONET/
SDH (up to OC48/STM16), Fibre Channel, Gigabit Ether-
net, and other optical standards. This feature is available
when the O/E is used on a supported oscilloscope. The
universal reference receiver supports any data rate up
to 3 GHz and remains calibrated on any channel of the
oscilloscope.
Key Features
Compatible with LabMaster 10 Zi oscilloscopes
•
•
•
Key Features
Frequency range DC to 9.5 GHz (electrical, -3 dB)
Frequency range to 5 GHz (6 GHz optical)
•
62.5 µm or narrower multi-mode or single-mode
•
Reference receiver support from 8GFC to 10GFC FEC, or
Custom (<12.5Gb/s)
fiber input
Broad wavelength range:
•
Full bandwidth mode (no reference receiver applied)
•
•
•
•
•
•
– 500–870 nm (OE425, OE525)
– 950–1630 nm (OE455, OE555)
62.5/125 µm multi-mode or single-mode fiber input
High responsivity
•
Broad wavelength range (750 to 1650 nm)
Low noise
•
+7 dBm (5 mW) max peak optical power
Included Accessories:
•
Multi-mode optical fiber jumper FC-FC
FC to ST adapter
Low noise (as low as 25 pW/√Hz)
FC to SC adapter
Ideal for Eye Mask, Extinction Ratio, and Optical
Modulation Amplitude (OMA) testing
Ordering Information
Product Description
Product Code
Optical-to-Electrical Converter, DC to 36 GHz, 830 to 1600nm
OE6250G-M
Optical-to-Electrical Converter, 785 to 1550 nm, 2.92 mm connector with ProLink adapter
Optical-to-Electrical Converter, 500–870 nm ProBus BNC Connector * Limited Availability
Optical-to-Electrical Converter, 950–1630 nm ProBus BNC Connector * Limited Availability
Optical-to-Electrical Converter, 500–870 nm ProLink BMA Connector * Limited Availability
Optical-to-Electrical Converter, 950–1630 nm ProLink BMA Connector
OE695G
OE425
OE455
OE525
OE555
45
PASSIVE PROBES
PASSIVE PROBES
Teledyne LeCroy
Passive Probe
Passive probes are the standard probe provided with most
oscilloscopes. Typical passive probes provide a ÷10 attenuation and
feature a high input resistance of 10 MΩ. This high input resistance
means that passive probes are the ideal tool for low frequency signals
since circuit loading at these frequencies is minimized. Passive probes
are designed to handle voltages of at least 400 V, some as high as
600 V. Teledyne LeCroy passive probes feature an attenuation sense
pin which tells the oscilloscope to scale the waveforms automatically
requiring no user input.
Model Numbers:
PP016
PP018
PP019
PP020
PP021
PP022
PP023
PP024
PP025
PP026
47
PASSIVE PROBES
Each passive probe is recommended for a certain oscilloscope, using the right
passive probe with the right oscilloscope means that the probe can be properly
compensated across the entire bandwidth. Using probes with a different
oscilloscope will only let you compensate for low frequencies.
Specifications
Types
Bandwidth
Input R
Input C Attenuation Maximum
Voltage
Diameter
PP016
300 MHz/
10 MHz
10 MΩ/
1 MΩ
12 pF/
46 pF
10 pF
12 pF
11 pF
11 pF
10 pF
10 pF
10 pF
10 pF
10 pF
÷10/
÷1
600 V
5 mm
PP018
PP019
PP020
PP021
PP022
PP023
PP024
PP025
PP026
500 MHz
200 MHz
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
10 MΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ
10 MΩ
÷10
÷10
÷10
÷10
÷10
÷10
÷10
÷10
÷10
350 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
500 V
5 mm
5 mm
5 mm
2.5 mm
2.5 mm
2.5 mm
5 mm
Teledyne LeCroy
Passive Probe
Model Numbers:
PP016
5 mm
5 mm
PP018
PP019
PP020
PP021
Passive Probe Accessories for PP016
Replacement Part Kit: PKIT3-5MM-101
PP022
PP023
PP024
Trimmer Tool
PP026
Color Coding Rings
(set)
Ground Lead
Sprung Hook
Rigid Tip
BNC Adapter
Ground Spring
Tip Insulator
IC Tip Insulator
48
PASSIVE PROBES
Passive Probe Accessories for
Passive Probe Accessories for
PP019 and PP020 – Part numbers in blue
Replacement Part Kit: PKIT4-5MM-101
PP024, PP025, and PP026 – Part numbers in gray
Replacement Part Kit: PKIT6-5MM-101
PP021, PP022, and PP023
Replacement Part Kit: PKIT5-2.5MM-101
PK4-5MM-5
PK5-PK6-001
Trimmer Tool
PK5-PK6-001
Trimmer Tool
PK4-5MM-8
PK5-PK6-002
Color Coding Rings
(set)
PK5-PK6-002
Color Coding Rings
(set)
PK5-2.5MM-111
Swivel Ground
Lead Adapter
PK4-5MM-2
PK6-5MM-103
Ground Lead with Alligator Clip
PK5-2.5MM-105
Long Collar
PK5-2.5MM-103
Short Collar
PK6-5MM-107
Spring Tip
PK4-5MM-4
PK6-5MM-101
Rigid Probe Tip
PK5-2.5MM-101
Ground Lead with
Alligator Clip
PK4-5MM-1
PK6-5MM-102
Sprung Hook
PK5-2.5MM-109
BNC Adapter 2.5mm
PK6-5MM-108
Probe Tip Cover
PK5-2.5MM-104
Sprung Hook
PK4-5MM-3
PK6-5MM-106
BNC Adapter 5mm
PK5-2.5MM-113
PCB Adapter
PK6-5MM-105
PCB Adapter
PK4-5MM-6
PK6-5MM-109
IC Tip Insulator
PK5-2.5MM-110
Swivel Ground Lead
PK5-2.5MM-112
Ground Spring
PK4-5MM-7
PK6-5MM-110
Tip Insulator
PK5-2.5MM-106
IC Tip Insulators (Black, Brown, Blue, Green, Gray)
PK4-5MM-9
PK6-5MM-104
Ground Spring
PK5-2.5MM-107
Tip Insulator
2.5mm Cap
PK6-5MM-108
Probe Tip Cover
PK5-2.5MM-102
Rigid Probe Tip
Ordering Information
Product Description
Product Code
PK5-2.5MM-114
Spring Tip
10:1, 10 MΩ, 300 MHz Passive Probe
PP016
PP018
PP019
PP020
PP021
PP022
PP023
PP024
PP025
PP026
500 MHz Passive Probe, 10:1, 10 MΩ
250 MHz Passive Probe, 10:1, 10 MΩ
500 MHz Passive Probe, 10:1, 10 MΩ
PK5-2.5MM-108
Probe Tip Cover
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ
500 MHz Passive Probe, 2.5mm, 10:1, 10 MΩ
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ
500 MHz Passive Probe, 5mm, 10:1, 10 MΩ
49
PROBE ADAPTERS
Probe adapters provide simple and easy interface of third-party probes as well
as change between the different Teledyne LeCroy Oscilloscope input and cable
types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapt-
ers, changing between the Teledyne LeCroy Oscilloscope’s input type may have
an effect on the overall performance of the channel.
Teledyne LeCroy
Probe Adapter
Model Numbers:
CA10
TPA10
CA10
The CA10 is a programmable and customizable interface device that seamlessly
incorporates third party current transducers/transformers with Teledyne LeCroy
oscilloscopes or motor drive analyzers. The easy to use interface provides the
ability for the CA10 to be programmed to contain the specifications of the current
sensor allowing it to automatically correct for the gain or attenuation and display
results in Ampere units. This allows the third party device to be recognized and
operate as if it were a Teledyne LeCroy probe.
Key Features
Provides ability for third party
•
current sensor to operate like a
Teledyne LeCroy probe
Programmable EEPROM for
•
saving third party current sensor
parameters
Specifications
Allows for addition of shunt
•
Input Coupling
DC, AC, Both
1MΩ or 50Ω
Input Termination
resistorandRLCfiltercomponents
Programmable Bandwidth Filters
Transformer/Transducer Interface
Scaling Factors
Resistive Termination (if required)
Oscilloscope Interface
Full, 200 MHz, 20 MHz
ProBus Active interface with
BNC
•
Programmable
Customizable (See Operator’s Manual for details)
automatic scaling in A/div
Easy to use, saves time and
•
Teledyne LeCroy ProBus
possible errors
Note: Some third party devices will require a separate power supply or batteries. The CA10 does not have
the ability to supply the power to these devices.
Ordering Information
Product Description
Product Code
ProBus Current Sensor Adapter
CA10
Included with Standard Configuration CA10
Description
CA10 ProBus Current Adapter
Qty
1
Heat-Shrink tubing (6" length)
Removable Labels (sheet of 20)
1
1
50
PROBE ADAPTERS
Key Features
Allows TekProbe™ interface level II
•
probes to work with any
ProBus-equipped Teledyne LeCroy
oscilloscope
Automatic probe detection
•
Provides all necessary power and
•
offset control to the attached probe
Supports probes up to 4 GHz
•
Easy firmware updates
•
Wide variety of probes
•
supported including:
Preamplifiers
Current Probes
Single-Ended Active Probes
Differential Active Probes
–
TPA10
–
The TPA10 ProBus™ Probe Adapter enables you to connect select TekProbe
interface level II probes to any ProBus-equipped Teledyne LeCroy instrument.
The TPA10 supplies all necessary power and offset control to the probe and
automatically detects which probe is attached.
–
–
Specifications
Ordering Information
Product Description
Electrical Characteristics
Bandwidth
Product Code
4 GHz (adapter only)
+15V, -15V, +5V, -5V (each 2%)
±1V (1%)
TPA10 ProBus Adapter
TPA10
Power Supplies
Offset Voltage
Max. Input Voltage
47 V , 33 V
pk
rms
Supported Probes
The following TekProbe devices are supported for use
with TPA10:
Environmental
Operating Temperature Range
0 to 50 ºC
Non-operating Temperature Range -40 to +70 ºC
Humidity
Preamplifiers
5% to 95% RH (10 to 40 ºC);
5% to 75% (above 40 ºC);
1 MHz Differential Preamplifier
ADA400A
RH not controlled below 10 ºC
Operating Altitude
3000 meters maximum
Current Probes
50 MHz AC/DC Current Probe
TCP202/TCP202A
Physical
Dimensions (WxHxD)
39 mm x 31.1 mm x 88.6 mm
(1.54” x 1.22” x 3.49”)
Single-ended Active Probes
750 MHz Single-ended Active Probe
1 GHz Single-ended Active Probe
1.5 GHz Single-ended Active Probe
4 GHz Single-ended Active Probe
4 GHz Single-ended Active Probe
P6205
P6243
P6245
P6241
P6249
Weight
119 g (0.26 lb)
The TPA10 requires the Teledyne LeCroy oscilloscope to be running firmware
version 7.8.0.0 or greater.
Differential Active Probes
100 MHz Differential Probe
50 MHz Differential Probe
400 MHz Differential Probe
1 GHz Differential Probe
P5205/P5205A
P5210/P5210A
P6246
P6247
1.5 GHz Differential Probe
500 MHz Differential Probe
1 GHz Differential Probe
P6248
P6250
P6251
51
TRANSMISSION LINE PROBES
Transmission line probes are a special type of passive probe designed for use at
very high frequencies. They replace the high impedance probe cable found in a
traditional passive probe with a precision transmission line, with a characteristic
impedance that matches the oscilloscope input (50 Ω). This greatly reduces
the input capacitance to a fraction of a picofarad, minimizing the loading of
high frequency signals. A matching network at the tip increases the DC input
resistance. While they have lower DC input resistance than a traditional passive
probe (usually 500 Ω to 5 kΩ), the input impedance of these probes remains
nearly constant over their entire frequency range. A traditional ÷10 passive probe
will have a 10 MΩ input impedance at DC, however this impedance drops rapidly
with frequency, passing below the input impedance of a transmission line probe at
less than 100 MHz.
Teledyne LeCroy
Transmission Line Probe
Model Number:
In some applications, transmission line probes offer advantages over active
probes. In addition to being less expensive, their passive design is more robust
to over voltage and ESD exposure. They are useful in applications producing fast
rising, narrow pulses with amplitudes which exceed the dynamic range of active
probes. They also tend to have less parasitic effects on frequency response.
PP066
52
TRANSMISSION LINE PROBES
PP066
The PP066 is a high-bandwidth passive probe designed for use
with the WaveMaster and other high-bandwidth oscilloscopes
with 50 Ω input termination. This very low capacitance probe
provides an excellent solution for higher frequency applications,
especially the probing of transmission lines with 20–100 Ω
impedance. The PP066 accommodates a wide range of
applications, including probing of analog and digital ICs
commonly found in computer, communications, data storage,
and other high-speed designs.
Key Features:
Interchangeable attenuator tips
•
Signal integrity at high bandwidth
•
Standard SMA cable connection
•
Ultra low capacitance
•
PP066 Specifications
Electrical Characteristics
Bandwidth
DC to 7.5 GHz
< 47 ps
Risetime
Input Capacitance
Input Resistance
< 0.20 pF
500 Ω (÷10 cartridge)
1000 Ω (÷20 cartridge)
15 V rms
Maximum Voltage
Cable Length
1 m
Ordering Information
Product Description
Product Code
PP066
7.5 GHz Low Capacitance Passive Probe
(÷10, 1 kΩ; ÷20, 500 Ω)
Included with PP0066
PACC-AD001, SMA to BNC Adapter
53
THIS PAGE INTENTIONALLY LEFT BLANK.
54
THIS PAGE INTENTIONALLY LEFT BLANK.
55
1-800-5-LeCroy
teledynelecroy.com
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
tlec_probecatalog-26jan21
© 2021 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
相关型号:
PACDN002Q/T
Trans Voltage Suppressor Diode, Unidirectional, 34 Element, Silicon, MO-137AD, QSOP-20
CALMIRCO
PACDN004/B
Trans Voltage Suppressor Diode, Unidirectional, 4 Element, Silicon, SOT-143, 4 PIN
CALMIRCO
PACDN004/R
Trans Voltage Suppressor Diode, Unidirectional, 4 Element, Silicon, SOT-143, 4 PIN
CALMIRCO
©2020 ICPDF网 联系我们和版权申明