Terminal Relay
G6D-F4B/G3DZ-F4B
CSM_G6D-F4B_G3DZ-F4B_DS_E_5_4
Easy-to-use, Space-saving Terminal Relay
with Four-point Output
• Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H
x D)
• Each terminal circuit (with coil or contact) is independent from
one another.
• Short Bar ensures easy connection of common and adjacent
terminals.
• Provided with a terminal cover that prevents electric-shock ac-
cidents.
• Relay and MOS FET relay models are available.
• LED operation indicator.
• Built-in diode absorbs coil surge.
• Mounts either on DIN track or screws.
• Tool for easy mounting or removal of Relays provided.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
• UL, CSA, and VDE certification for standard models (VDE:
G6D-F4B only).
Model Number Structure
■ Model Number Legend
G6D/G3DZ-@@
1
2
1. Terminal Form
F: Flat type
2. Number of Relays Mounted
4B:
4
Ordering Information
When your order, specify the rated voltage.
■ List of Models
Output
Contact configuration
Model
Rated voltage
12 VDC
Relay output
SPST-NO × 4
G6D-F4B
24 VDC
12 VDC
24 VDC
Power MOS FET relay out-
put
G3DZ-F4B
Note: When ordering add the rated coil voltage to the model number.
Example: G6D-F4B 24 VDC
Rated coil voltage
1
G6D-F4B/G3DZ-F4B
Specifications
■ Ratings
Coil Ratings (per G6D Relay)
Rated voltage
Rated current
Coil resistance
Must operate
voltage
Must release
voltage
Max. voltage
130%
Power
consumption
12 VDC
24 VDC
18.7 mA
10.5 mA
720 Ω
2,880 Ω
70% max.
(see note 1)
10% min.
Approx. 200 mW
Note: 1. The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down.
2. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of 10%.
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is
no continuous allowance.
5. The rated current includes the terminal’s LED current.
Contact Ratings (per G6D Relay)
Item
Resistive load (cosφ = 1)
Rated load
3 A at 250 VAC, 3 A at 30 VDC
Rated carry current
5 A
Max. switching voltage
250 VAC, 30 VDC
5 A
Max. switching current
Max. permissible capacity (reference value)
Error rate (reference value) (see note)
1,250 VA, 150 W
5 VDC, 10 mA
Note: This value is for a switching frequency of 120 times per minute.
■ Power MOS FET Relay Specifications
Input (per G3DZ Power MOS FET Relay)
Rated voltage
Operating voltage
Must operate
voltage level
Must release
voltage level
Input impedance
Rated current
12 VDC
24 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
9.6 VDC max.
19.2 VDC max.
1 VDC min.
2 kΩ 20%
4 kΩ 20%
8.0 mA 20%
8.2 mA 20%
Note: The rated current includes the terminal’s LED current.
Output (per G3DZ Power MOS FET Relay)
Load voltage
3 to 264 VAC
3 to 125 VDC
Note: There is no output polarity for the G3DZ.
Load current
Inrush current
100 μ to 0.3 A
6 A (10 ms)
2
G6D-F4B/G3DZ-F4B
■ Characteristics
Item
G6D-F4B
Relay output
Contact resistance (see note 2)
Must operate time (see note 3)
Release time (see note 3)
Insulation resistance
100 mΩ max.
10 ms max.
10 ms max.
1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts.
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
4,000 V (1.2 × 50 μs)
Impulse withstand voltage (between
coil and contacts)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 500 m/s2
Shock resistance
Malfunction: 100 m/s2
Endurance
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr)
Ambient temperature
Ambient humidity
Weight
Operating: –25°C to 55°C (with no icing)
Operating: 45% to 85%
Approx. 65 g
Note: 1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC
3. Ambient temperature condition: 23°C
Item
G3DZ-F4B
Power MOS FET relay output
Must operate time
10 ms max.
Release time
15 ms max.
Output ON-resistance
Leakage current at OFF state
Insulation resistance
Dielectric strength
2.4 Ω max.
10 μA max. (at 125 VDC)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between input and output terminals
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 500 m/s2
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Operating: –25°C to 55°C (with no icing)
Operating: 45% to 85%
Approx. 65 g
3
G6D-F4B/G3DZ-F4B
Engineering Data
ꢀ Endurance
ꢀ Maximum Switching
Power
G6D-F4B
500
300
100
250 VAC/30 VDC resistive load
50
30
DC resistive load AC resistive load
10
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
5
3
0
1
2
3
4
5
6
7
8
9
10
Switching current (A)
Switching voltage (V)
ꢀ Inrush Current Resistivity: Non-repetitive
ꢀ Load Current vs.
Keep the inrush current to half the rated value if it occurs repetitively.
Ambient Temperature
G3DZ-F4B
Energizing time (ms)
Ambient temperature (°C)
4
G6D-F4B/G3DZ-F4B
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G6D-F4B
G3DZ-F4B
Mounting Dimensions
16, M3 Phillips
head screws
Two, 4 dia. holes or M3.5 screw holes
8.7
Terminal Arrangement/
Internal Connections
(Top View)
4
8
3
7
2
6
1
5
IN
1
2
3
4
4
8
3
7
2
6
1
5
Input side
68 max.
76 0.3
RY1 RY2 RY3 RY4
OUT
1
2
3
4
Output side
12
16
11
15
10
14
9
12
16
11
15
10
14
9
13
13
8.7
31 max.
35 max.
23 0.3
Note1 : Make sure that the polarity of
the input terminal is correct.
Tool for removing relays.
Note2 : There is no output polarity for
the G6D-F4B and G3DZ-F4B.
■ Accessories (Order Separately)
G6D-4-SB Short Bar
Applicable model
Model
G6D-4-SB
G6D-F4B
G3DZ-F4B
Relay Mounting Products
Short Bar
Name
Model
PFP-100N
Applicable Terminal Relay
Model
Mounting track
G6D-F4B
G6D-4-SB
PFP-50N
PFP-100N2
PFP-M
G3DZ-F4B
End plate
Spacer
PFP-S
Replacement Relays
Applicable Terminal
Relay
Model
Rated voltage
G6D-F4B
G6D-1A-ASI
G3DZ-2R6PL
12 VDC
24 VDC
12 VDC
24 VDC
G3DZ-F4B
Note: Error rate (P level) for the G6D-1A-ASI is 5 V at 10 mA and that
for the G6D-1A-AP is 5 V at 1 mA.
5
G6D-F4B/G3DZ-F4B
Safety Precautions
Refer to Safety Precautions for All Relays.
Wiring
Wiring
Be sure to turn OFF the power when wiring the Unit and do not touch
the charged terminals of the Unit. Otherwise, an electric shock may
result.
Pay utmost attention not to make mistakes with the polarity of the
input terminals.
Do not apply overvoltage to the input terminals. Otherwise, the Unit
may malfunction or burn.
Coil Voltage
Make sure not to impose voltage exceeding the permissible voltage
on the coil continuously.
Relay Models
Do not connect the Unit to loads exceeding the rated switching power
(switching voltage or current). Otherwise, faulty insulation, contact
weld, or faulty contact of Relays, or damage to Relays may result, or
the Relays may malfunction or burn.
Do not connect any inductive load in parallel to the coil input as
shown in the following example or power supply with a surge voltage.
Otherwise, the surge absorption diode will be damaged.
Do Not Use the Following Circuit
The life of Relays varies with the switching condition. Test the Relays
under the actual operating conditions before using the Relays within
the permissible switching frequency. The use of deteriorated Relays
may result in the faulty insulation of the Relays or cause the Relays
to burn.
Coil surge
absorption
diode
Inductive load
G6D coil
Do not use the Unit in locations with inflammable gas. Otherwise, a
fire or explosion due to the heat of the Relays or sparks from the
Relays may result when they are switched.
SSR Output (Power MOS FET Relay
Model)
Do not connect the Unit to loads consuming a total current exceeding
the rated output current of the Unit. Otherwise, the output element of
the Unit may be damaged and a short or open-circuit malfunction
may result.
Handling
Do not drop, shock, or vibrate the Unit excessively. Otherwise, dam-
age to the Unit may result or the Unit may malfunction.
Make sure that all the Relays are properly mounted before use.
Screw Tightening Torque
Tighten each terminal screw to a torque described below.
M3 terminal screw: 0.4 to 0.56 N·m.
If the Unit is connected to a DC inductive load, connect a diode to the
Unit to protect the Unit from counter-electromotive voltage, otherwise
the counter-electromotive voltage may damage the output element
and a short or open-circuit malfunction may result.
M3.5 terminal screw: 0.78 to 1.18 N·m.
Tighten each mounting screw to a torque of 0.59 to 0.98 N·m.
■ Correct Use
Installation Environment
Do not install the Unit in the following locations. Otherwise, damage
to the Unit may result or the Unit may malfunction.
Mounting
When mounting two or more Units, reduce the current and ON duty
and provide an appropriate distance between the Units so that the
ambient temperature will not exceed 55°C.
Locations with direct sunlight.
Locations with an ambient temperature range not within –25°C to
55°C.
Relay Replacement
Use the Relay Removal Tool provided with the Unit to dismount a
Relay.
Locations with rapid temperature changes resulting in condensation
or locations with relative humidity ranges not within 45% to 85%.
Locations with corrosive or inflammable gas.
Be sure to turn OFF the power to the Unit before replacing a Relay.
Locations with excessive dust, salinity, or metal powder.
Locations with vibration or shock affecting the Unit.
Locations with water, oil, or chemical sprayed on the Unit.
When mounting a Relay, insert the Relay vertically so that the relay
terminals will come in contact with the socket contact pins properly.
Do not mount Relays that are different to one another in voltage.
Disassembly, Repair, and Modification
Do not disassemble, repair, or modify the Unit. Otherwise, an electric
shock may result or the Unit may malfunction.
Mounted Relays
Relays and SSRs cannot be mounted together.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.
相关型号:
G3DZ2R6PLDC12
SSR Identical to the G6D in Size with a Maximum AC/DC Switching Current of 0.6 A
OMRON
©2020 ICPDF网 联系我们和版权申明