G3F-203SN-VD [OMRON]

International Standards for G3F Series, Same Profile as MY Power Relays;
G3F-203SN-VD
型号: G3F-203SN-VD
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

International Standards for G3F Series, Same Profile as MY Power Relays

输出元件 光电
文件: 总7页 (文件大小:538K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Solid State Relays G3@-VD  
G3F/G3FD  
CSM_G3F_G3FD_DS_E_2_1  
International Standards for G3F Series,  
Same Profile as MY Power Relays  
• Shape-compatible with mechanical relays.  
• Certified by UL, CSA, and VDE (model numbers with a suffix of  
“-VD”).  
• Socket type, same size as MY Power Relays.  
• Operation indicator provided to confirm input (model numbers  
with “N” before the suffix).  
Refer to Safety Precautions on page 6.  
Model Number Structure  
Model Number Legend  
G3F-@@@@@-@  
2
7
3 4 5 6  
1
1. Basic Model Name  
G3F: Solid State Relay  
2. Rated Load Power Supply Voltage  
2: 200 VAC  
3. Rated Load Current  
5. Zero Cross Function  
Blank:  
L:  
Equipped with zero cross functions  
Not equipped with zero cross function  
6. Operation Indicator  
Blank:  
N:  
Not equipped with operation indicator  
Equipped with operation indicator  
02:  
03:  
2 A  
3 A  
7. Certification  
4. Terminal Type  
VD:  
Certified by UL, CSA, and VDE  
S:  
Plug-in terminals  
G3FD-@@@@-@  
2
7
3 4 5 6  
1
1. Basic Model Name  
G3F: Solid State Relay  
2. Load Power Supply Type  
D: DC  
3. Rated Load Power Supply Voltage  
5. Terminal Type  
S:  
Plug-in terminals  
6. Operation Indicator  
Blank:  
N:  
Not equipped with operation indicator  
Equipped with operation indicator  
X:  
1:  
50 VDC  
100 VDC  
7. Certification  
VD: Certified by UL, CSA, and VDE  
4. Rated Load Current  
02:  
03:  
2 A  
3 A  
1
G3F/G3FD  
Ordering Information  
List of Models  
Isolation  
Zero cross  
Indicator  
Yes  
Rated output load  
Rated input voltage  
Model  
function  
Photocoupler  
Yes  
3 A at 100 to 240 VAC (See note 1.)  
2 A at 100 to 240 VAC (See note 1.)  
5 to 24 VDC  
100/110 VAC  
200/220 VAC  
5 VDC  
G3F-203SN-VD  
G3F-202SN-VD  
Phototriac coupler  
Photocoupler  
No  
3 A at 100 to 240 VAC (See note 1.)  
G3F-203SLN-VD  
12 VDC  
24 VDC  
3 A at 4 to 48 VDC (See note 2.)  
2 A at 5 to 110 VDC  
5 to 24 VDC  
100/110 VAC  
200/220 VAC  
5 to 24 VDC  
4 to 24 VDC  
5 VDC  
G3FD-X03SN-VD  
G3FD-102SN-VD  
Photocoupler  
Yes  
No  
No  
3 A at 100 to 240 VAC (See note 1.)  
G3F-203S-VD  
G3F-203SL-VD  
Phototriac coupler  
12 VDC  
24 VDC  
Photocoupler  
3 A at 4 to 48 VDC (See note 2.)  
2 A at 5 to 110 VDC  
4 to 24 VDC  
G3FD-X03S-VD  
G3FD-102S-VD  
Note: 1. Product is labelled “240 VAC”.  
2. Product is labelled “48 VDC”.  
3. When ordering, specify the rated input voltage.  
Accessories (Order Separately)  
Connecting Sockets  
Item  
PYF08A-E  
PY08  
Back connecting  
Solder terminals  
PY08-02  
PY08QN(2)  
Connecting  
Front connecting  
Mounting method/  
Terminal type  
Track mounted/  
screw terminals  
PCB terminals  
Wrapping terminals  
Hold-down clip  
PYC-A1  
PYC-P  
2
G3F/G3FD  
Specifications  
Ratings (at an Ambient Temperature of 25°C)  
Input  
Model  
Rated voltage  
5 to 24 VDC  
Operating voltage  
Impedance  
Voltage level  
Must operate voltage Must release voltage  
G3F-203SN-VD  
G3F-202SN-VD  
4 to 28 VDC  
15 mA max. (See note.) 4 VDC max.  
1 VDC min.  
20 VAC min.  
40 VAC min.  
1 VDC min.  
100/110 VAC  
200/220 VAC  
5 VDC  
75 to 125 VAC  
150 to 250 VAC  
4 to 6 VDC  
41 k20%  
72 k20%  
390 20%  
900 20%  
2 k20%  
75 VAC max.  
150 VAC max.  
4 VDC max.  
G3F-203SLN-VD  
12 VDC  
9.6 to 14.4 VDC  
19.2 to 28.8 VDC  
4 to 28 VDC  
9.6 VDC max.  
19.2 VDC max.  
4 VDC max.  
24 VDC  
1.5 k+20%  
1.5 k+20%  
/
/
G3FD-X03SN-VD 5 to 24 VDC  
G3FD-102SN-VD 5 to 24 VDC  
100/110 VAC  
–10%  
4 to 28 VDC  
4 VDC max.  
–10%  
75 to 125 VAC  
150 to 250 VAC  
3 to 28 VDC  
41 k20%  
72 k20%  
15 mA max. (See note.) 3 VDC max.  
75 VAC max.  
150 VAC max.  
20 VAC min.  
40 VAC min.  
1 VDC min.  
200/220 VAC  
G3F-203S-VD  
G3F-203SL-VD  
4 to 24 VDC  
5 VDC  
4 to 6 VDC  
390 20%  
900 20%  
2 k20%  
4 VDC max.  
12 VDC  
9.6 to 14.4 VDC  
19.2 to 28.8 VDC  
3 to 28 VDC  
9.6 VDC max.  
19.2 VDC max.  
3 VDC max.  
24 VDC  
1.5 k+20%  
/
–10%  
G3FD-X03S-VD  
G3FD-102S-VD  
4 to 24 VDC  
Note: 1. The input impedance is given for the maximum operating range. For details, refer to the Technical Guide for Solid State Relays.  
2. Constant-current input circuit.  
Output  
Model  
Rated load  
voltage  
Applicable load  
Load current  
Load voltage range  
75 to 264 VAC  
Inrush current  
45 A (60 Hz, 1 cycle)  
G3F-203SN-VD  
G3F-203SLN-VD  
G3F-203S-VD  
100 to 240 VAC  
0.1 to 3 A at 40°C  
G3F-203SL-VD  
G3F-203SN-VD  
100 to 240 VAC  
75 to 264 VAC  
3 to 52.8 VDC  
0.1 to 2 A at 40°C  
0.1 to 3 A at 40°C  
45 A (60 Hz, 1 cycle)  
18 A (10 ms)  
G3FD-X03SN-VD 4 to 48 VDC  
G3FD-X03S-VD  
G3FD-102SN-VD  
G3FD-102S-VD  
5 to 110 VDC  
3 to 125 VDC  
0.1 to 2 A at 40°C  
10 A (10 ms)  
3
G3F/G3FD  
Characteristics  
Item  
G3F-203SN-VD  
G3F-202SN-VD  
G3F-203S-VD  
G3F-203SLN-VD  
G3F-203SL-VD  
G3FD-X03SN-VD  
G3FD-X03S-VD  
G3FD-102SN-VD  
G3FD-102S-VD  
Operate time  
1/2 of load power  
source cycle + 1 ms  
max. (DC input)  
3/2 of load power  
source cycle + 1 ms  
max. (AC input)  
1 ms max.  
0.5 ms max.  
2 ms max.  
1.5 V max.  
0.5 ms max. (DC input) 0.5 ms max.  
20 ms max. (AC input)  
Release time  
1/2 of load power  
source cycle + 1 ms source cycle + 1 ms  
max. (DC input)  
3/2 of load power  
source cycle + 1 ms  
max. (AC input)  
1/2 of load power  
2.5 ms max. (DC input) 2.5 ms max.  
20 ms max. (AC input)  
max.  
Output ON voltage drop 1.6 V (RMS) max.  
Leakage current  
5 mA max.  
2.5 mA max.  
(at 100 VAC)  
5 mA max.  
5 mA max.  
(at 50 VDC)  
0.1 mA max.  
(at 100 VDC)  
0.1 mA max.  
(at 100 VDC)  
(at 100 VAC)  
10 mA max.  
(at 200 VAC)  
(at 200 VAC)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
100 Mmin. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min  
1,500 VAC, 50/60 Hz for 1 min  
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude  
Destruction: 1,000 m/s2  
Ambient temperature  
Operating: –30°C to 80°C (with no icing or condensation)  
Storage: –30°C to 100°C (with no icing or condensation)  
Ambient humidity  
Certified standards  
Operating: 45% to 85%  
G3F: UL508, CSA C22.2 No. 14, EN60947-4-3  
G3FD: UL508, CSA C22.2 No. 14, EN60950-1  
EMC  
Emission: EN55011 Group 1 Class B  
Immunity: EN61000-6-2  
Weight  
Approx. 50 g  
4
G3F/G3FD  
Engineering Data  
Load Current vs. Ambient Temperature Characteristics  
G3F-203SN-VD/203S-VD/203SLN-VD/  
203SL-VD  
G3FD-X03SN-VD/X03S-VD  
G3F-202SN-VD  
G3FD-102SN-VD/102S-VD  
Ambient temperature (°C)  
Ambient temperature (°C)  
One Cycle Surge Current: Non-repetitive  
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)  
G3FD-X03SN-VD/X03S-VD  
G3FD-102SN-VD/102S-VD  
G3F-203SN-VD/203S-VD/202SN-VD/  
203SLN-VD/203SL-VD  
10 20  
Energized time (ms)  
Energized time (ms)  
Energized time (ms)  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Terminal Arrangement/  
Internal Connections  
1
5
4
8(+)  
(+)  
28 max.  
Load  
Load power  
supply  
Load  
Input  
(
)
9
12()  
()  
13  
14  
+
36.5 max.  
42.5 max.  
21.5 max.  
+
Input voltage  
Note: The plus and minus symbols shown  
in parentheses are for DC loads.  
5
G3F/G3FD  
Safety Precautions  
Refer to Safety Precautions for All Solid State Relays.  
Precautions for Correct Use  
Please observe the following precautions to prevent failure to  
operate, malfunction, or undesirable effect on product performance.  
Connection  
The SSR for DC switching use can connect to a load regardless of  
the polarity of the positive and negative output terminals.  
Close Mounting of Multiple Relays  
If multiple Relays are mounted side by side, be aware that the outer  
wall of each SSR works as a heat sink.  
The SSR casing serves to dissipate heat. Install the Relays so that  
they are adequately ventilated. If poor ventilation is unavoidable,  
reduce the load current by half.  
Protective Terminal  
When using for AC inductive loads, connect the load terminals of the  
SSR to an inrush absorber (varistor).  
EMC Directive Compliance  
1. AC-switching models comply with EMC Directives under the  
following conditions ("-VD" models only).  
Less than 3 m  
Load  
Input  
Output  
Varistor  
G3F-VD  
Film Capacitor  
Varistor: 470 V, 0.6 W  
Film capacitor: 1 µF, 250 VAC  
Connect a varistor between the output terminals.  
Connect a film capacitor to the load power supply.  
The input cable must be less than 3 m.  
2. DC-switching models comply with EMC Directives under the  
following conditions ("-VD" models only).  
Less than 10 m  
Load  
G3FD-VD  
Input  
Output  
The input cable must be less than 10 m.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
6
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

G3FD-102S-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-102SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-X03S-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-X03SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3G

GLASS PASSIVATED JUNCTION RECTIFIER
VISHAY

G3G146-AB72-01

FAN BLWR CENT 226.8X130MM 115VAC
EBMPAPST

G3G315-M3G150FF

暂无描述
EBMPAPST

G3H

Solid State Relays
OMRON

G3H-203S-DC3-28

New Models with International Standards
OMRON

G3H-203S-VD

Solid State Relays
OMRON

G3H-203S-VDDC4-24

Trigger Output SSR, 1-Channel, 2000V Isolation
OMRON

G3H-203SL-VD

Solid State Relays
OMRON