Solid State Relays G3@-VD
G3F/G3FD
CSM_G3F_G3FD_DS_E_2_1
International Standards for G3F Series,
Same Profile as MY Power Relays
• Shape-compatible with mechanical relays.
• Certified by UL, CSA, and VDE (model numbers with a suffix of
“-VD”).
• Socket type, same size as MY Power Relays.
• Operation indicator provided to confirm input (model numbers
with “N” before the suffix).
Refer to Safety Precautions on page 6.
Model Number Structure
■ Model Number Legend
G3F-@@@@@-@
2
7
3 4 5 6
1
1. Basic Model Name
G3F: Solid State Relay
2. Rated Load Power Supply Voltage
2: 200 VAC
3. Rated Load Current
5. Zero Cross Function
Blank:
L:
Equipped with zero cross functions
Not equipped with zero cross function
6. Operation Indicator
Blank:
N:
Not equipped with operation indicator
Equipped with operation indicator
02:
03:
2 A
3 A
7. Certification
4. Terminal Type
VD:
Certified by UL, CSA, and VDE
S:
Plug-in terminals
G3FD-@@@@-@
2
7
3 4 5 6
1
1. Basic Model Name
G3F: Solid State Relay
2. Load Power Supply Type
D: DC
3. Rated Load Power Supply Voltage
5. Terminal Type
S:
Plug-in terminals
6. Operation Indicator
Blank:
N:
Not equipped with operation indicator
Equipped with operation indicator
X:
1:
50 VDC
100 VDC
7. Certification
VD: Certified by UL, CSA, and VDE
4. Rated Load Current
02:
03:
2 A
3 A
1
G3F/G3FD
Ordering Information
■ List of Models
Isolation
Zero cross
Indicator
Yes
Rated output load
Rated input voltage
Model
function
Photocoupler
Yes
3 A at 100 to 240 VAC (See note 1.)
2 A at 100 to 240 VAC (See note 1.)
5 to 24 VDC
100/110 VAC
200/220 VAC
5 VDC
G3F-203SN-VD
G3F-202SN-VD
Phototriac coupler
Photocoupler
No
3 A at 100 to 240 VAC (See note 1.)
G3F-203SLN-VD
12 VDC
24 VDC
−
3 A at 4 to 48 VDC (See note 2.)
2 A at 5 to 110 VDC
5 to 24 VDC
100/110 VAC
200/220 VAC
5 to 24 VDC
4 to 24 VDC
5 VDC
G3FD-X03SN-VD
G3FD-102SN-VD
Photocoupler
Yes
No
No
3 A at 100 to 240 VAC (See note 1.)
G3F-203S-VD
G3F-203SL-VD
Phototriac coupler
12 VDC
24 VDC
Photocoupler
−
3 A at 4 to 48 VDC (See note 2.)
2 A at 5 to 110 VDC
4 to 24 VDC
G3FD-X03S-VD
G3FD-102S-VD
Note: 1. Product is labelled “240 VAC”.
2. Product is labelled “48 VDC”.
3. When ordering, specify the rated input voltage.
■ Accessories (Order Separately)
Connecting Sockets
Item
PYF08A-E
PY08
Back connecting
Solder terminals
PY08-02
PY08QN(2)
Connecting
Front connecting
Mounting method/
Terminal type
Track mounted/
screw terminals
PCB terminals
Wrapping terminals
Hold-down clip
PYC-A1
PYC-P
2
G3F/G3FD
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input
Model
Rated voltage
5 to 24 VDC
Operating voltage
Impedance
Voltage level
Must operate voltage Must release voltage
G3F-203SN-VD
G3F-202SN-VD
4 to 28 VDC
15 mA max. (See note.) 4 VDC max.
1 VDC min.
20 VAC min.
40 VAC min.
1 VDC min.
100/110 VAC
200/220 VAC
5 VDC
75 to 125 VAC
150 to 250 VAC
4 to 6 VDC
41 kΩ 20%
72 kΩ 20%
390 Ω 20%
900 Ω 20%
2 kΩ 20%
75 VAC max.
150 VAC max.
4 VDC max.
G3F-203SLN-VD
12 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
4 to 28 VDC
9.6 VDC max.
19.2 VDC max.
4 VDC max.
24 VDC
1.5 kΩ+20%
1.5 kΩ+20%
/
/
G3FD-X03SN-VD 5 to 24 VDC
G3FD-102SN-VD 5 to 24 VDC
100/110 VAC
–10%
4 to 28 VDC
4 VDC max.
–10%
75 to 125 VAC
150 to 250 VAC
3 to 28 VDC
41 kΩ 20%
72 kΩ 20%
15 mA max. (See note.) 3 VDC max.
75 VAC max.
150 VAC max.
20 VAC min.
40 VAC min.
1 VDC min.
200/220 VAC
G3F-203S-VD
G3F-203SL-VD
4 to 24 VDC
5 VDC
4 to 6 VDC
390 Ω 20%
900 Ω 20%
2 kΩ 20%
4 VDC max.
12 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
3 to 28 VDC
9.6 VDC max.
19.2 VDC max.
3 VDC max.
24 VDC
1.5 kΩ+20%
/
–10%
G3FD-X03S-VD
G3FD-102S-VD
4 to 24 VDC
Note: 1. The input impedance is given for the maximum operating range. For details, refer to the Technical Guide for Solid State Relays.
2. Constant-current input circuit.
Output
Model
Rated load
voltage
Applicable load
Load current
Load voltage range
75 to 264 VAC
Inrush current
45 A (60 Hz, 1 cycle)
G3F-203SN-VD
G3F-203SLN-VD
G3F-203S-VD
100 to 240 VAC
0.1 to 3 A at 40°C
G3F-203SL-VD
G3F-203SN-VD
100 to 240 VAC
75 to 264 VAC
3 to 52.8 VDC
0.1 to 2 A at 40°C
0.1 to 3 A at 40°C
45 A (60 Hz, 1 cycle)
18 A (10 ms)
G3FD-X03SN-VD 4 to 48 VDC
G3FD-X03S-VD
G3FD-102SN-VD
G3FD-102S-VD
5 to 110 VDC
3 to 125 VDC
0.1 to 2 A at 40°C
10 A (10 ms)
3
G3F/G3FD
■ Characteristics
Item
G3F-203SN-VD
G3F-202SN-VD
G3F-203S-VD
G3F-203SLN-VD
G3F-203SL-VD
G3FD-X03SN-VD
G3FD-X03S-VD
G3FD-102SN-VD
G3FD-102S-VD
Operate time
1/2 of load power
source cycle + 1 ms
max. (DC input)
3/2 of load power
source cycle + 1 ms
max. (AC input)
1 ms max.
0.5 ms max.
2 ms max.
1.5 V max.
0.5 ms max. (DC input) 0.5 ms max.
20 ms max. (AC input)
Release time
1/2 of load power
source cycle + 1 ms source cycle + 1 ms
max. (DC input)
3/2 of load power
source cycle + 1 ms
max. (AC input)
1/2 of load power
2.5 ms max. (DC input) 2.5 ms max.
20 ms max. (AC input)
max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current
5 mA max.
2.5 mA max.
(at 100 VAC)
5 mA max.
5 mA max.
(at 50 VDC)
0.1 mA max.
(at 100 VDC)
0.1 mA max.
(at 100 VDC)
(at 100 VAC)
10 mA max.
(at 200 VAC)
(at 200 VAC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Destruction: 1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Ambient humidity
Certified standards
Operating: 45% to 85%
G3F: UL508, CSA C22.2 No. 14, EN60947-4-3
G3FD: UL508, CSA C22.2 No. 14, EN60950-1
EMC
Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight
Approx. 50 g
4
G3F/G3FD
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3F-203SN-VD/203S-VD/203SLN-VD/
203SL-VD
G3FD-X03SN-VD/X03S-VD
G3F-202SN-VD
G3FD-102SN-VD/102S-VD
Ambient temperature (°C)
Ambient temperature (°C)
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3FD-X03SN-VD/X03S-VD
G3FD-102SN-VD/102S-VD
G3F-203SN-VD/203S-VD/202SN-VD/
203SLN-VD/203SL-VD
10 20
Energized time (ms)
Energized time (ms)
Energized time (ms)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/
Internal Connections
1
5
4
8(+)
(+)
28 max.
Load
Load power
supply
Load
Input
(
)
9
12(−)
(−)
13
14
+
36.5 max.
42.5 max.
21.5 max.
−
+
−
Input voltage
Note: The plus and minus symbols shown
in parentheses are for DC loads.
5
G3F/G3FD
Safety Precautions
Refer to Safety Precautions for All Solid State Relays.
■ Precautions for Correct Use
Please observe the following precautions to prevent failure to
operate, malfunction, or undesirable effect on product performance.
Connection
The SSR for DC switching use can connect to a load regardless of
the polarity of the positive and negative output terminals.
Close Mounting of Multiple Relays
If multiple Relays are mounted side by side, be aware that the outer
wall of each SSR works as a heat sink.
The SSR casing serves to dissipate heat. Install the Relays so that
they are adequately ventilated. If poor ventilation is unavoidable,
reduce the load current by half.
Protective Terminal
When using for AC inductive loads, connect the load terminals of the
SSR to an inrush absorber (varistor).
EMC Directive Compliance
1. AC-switching models comply with EMC Directives under the
following conditions ("-VD" models only).
Less than 3 m
Load
Input
Output
Varistor
G3F-VD
Film Capacitor
Varistor: 470 V, 0.6 W
Film capacitor: 1 µF, 250 VAC
• Connect a varistor between the output terminals.
• Connect a film capacitor to the load power supply.
• The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the
following conditions ("-VD" models only).
Less than 10 m
Load
G3FD-VD
Input
Output
• The input cable must be less than 10 m.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
相关型号:
©2020 ICPDF网 联系我们和版权申明