G3DZ-F4B24VDC [OMRON]

Power/Signal Relay;
G3DZ-F4B24VDC
型号: G3DZ-F4B24VDC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay

文件: 总7页 (文件大小:525K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Terminal Relay  
G6D-F4B/G3DZ-F4B  
CSM_G6D-F4B_G3DZ-F4B_DS_E_5_4  
Easy-to-use, Space-saving Terminal Relay  
with Four-point Output  
• Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H  
x D)  
• Each terminal circuit (with coil or contact) is independent from  
one another.  
• Short Bar ensures easy connection of common and adjacent  
terminals.  
• Provided with a terminal cover that prevents electric-shock ac-  
cidents.  
• Relay and MOS FET relay models are available.  
• LED operation indicator.  
• Built-in diode absorbs coil surge.  
• Mounts either on DIN track or screws.  
• Tool for easy mounting or removal of Relays provided.  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
• UL, CSA, and VDE certification for standard models (VDE:  
G6D-F4B only).  
Model Number Structure  
Model Number Legend  
G6D/G3DZ-@@  
1
2
1. Terminal Form  
F: Flat type  
2. Number of Relays Mounted  
4B:  
4
Ordering Information  
When your order, specify the rated voltage.  
List of Models  
Output  
Contact configuration  
Model  
Rated voltage  
12 VDC  
Relay output  
SPST-NO × 4  
G6D-F4B  
24 VDC  
12 VDC  
24 VDC  
Power MOS FET relay out-  
put  
G3DZ-F4B  
Note: When ordering add the rated coil voltage to the model number.  
Example: G6D-F4B 24 VDC  
Rated coil voltage  
1
G6D-F4B/G3DZ-F4B  
Specifications  
Ratings  
Coil Ratings (per G6D Relay)  
Rated voltage  
Rated current  
Coil resistance  
Must operate  
voltage  
Must release  
voltage  
Max. voltage  
130%  
Power  
consumption  
12 VDC  
24 VDC  
18.7 mA  
10.5 mA  
720 Ω  
2,880 Ω  
70% max.  
(see note 1)  
10% min.  
Approx. 200 mW  
Note: 1. The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down.  
2. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of 10%.  
3. Operating characteristics were measured at a coil temperature of 23°C.  
4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is  
no continuous allowance.  
5. The rated current includes the terminal’s LED current.  
Contact Ratings (per G6D Relay)  
Item  
Resistive load (cosφ = 1)  
Rated load  
3 A at 250 VAC, 3 A at 30 VDC  
Rated carry current  
5 A  
Max. switching voltage  
250 VAC, 30 VDC  
5 A  
Max. switching current  
Max. permissible capacity (reference value)  
Error rate (reference value) (see note)  
1,250 VA, 150 W  
5 VDC, 10 mA  
Note: This value is for a switching frequency of 120 times per minute.  
Power MOS FET Relay Specifications  
Input (per G3DZ Power MOS FET Relay)  
Rated voltage  
Operating voltage  
Must operate  
voltage level  
Must release  
voltage level  
Input impedance  
Rated current  
12 VDC  
24 VDC  
9.6 to 14.4 VDC  
19.2 to 28.8 VDC  
9.6 VDC max.  
19.2 VDC max.  
1 VDC min.  
2 kΩ 20%  
4 kΩ 20%  
8.0 mA 20%  
8.2 mA 20%  
Note: The rated current includes the terminal’s LED current.  
Output (per G3DZ Power MOS FET Relay)  
Load voltage  
3 to 264 VAC  
3 to 125 VDC  
Note: There is no output polarity for the G3DZ.  
Load current  
Inrush current  
100 μ to 0.3 A  
6 A (10 ms)  
2
G6D-F4B/G3DZ-F4B  
Characteristics  
Item  
G6D-F4B  
Relay output  
Contact resistance (see note 2)  
Must operate time (see note 3)  
Release time (see note 3)  
Insulation resistance  
100 mΩ max.  
10 ms max.  
10 ms max.  
1,000 MΩ min. (at 500 VDC)  
Dielectric strength  
2,000 VAC, 50/60 Hz for 1 min between coil and contacts.  
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity  
750 VAC, 50/60 Hz for 1 min between contacts of same polarity  
4,000 V (1.2 × 50 μs)  
Impulse withstand voltage (between  
coil and contacts)  
Vibration resistance  
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Destruction: 500 m/s2  
Shock resistance  
Malfunction: 100 m/s2  
Endurance  
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)  
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)  
100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr)  
Ambient temperature  
Ambient humidity  
Weight  
Operating: –25°C to 55°C (with no icing)  
Operating: 45% to 85%  
Approx. 65 g  
Note: 1. The above values are initial values.  
2. Measurement condition: 1 A at 5 VDC  
3. Ambient temperature condition: 23°C  
Item  
G3DZ-F4B  
Power MOS FET relay output  
Must operate time  
10 ms max.  
Release time  
15 ms max.  
Output ON-resistance  
Leakage current at OFF state  
Insulation resistance  
Dielectric strength  
2.4 Ω max.  
10 μA max. (at 125 VDC)  
100 MΩ min. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min between input and output terminals  
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity  
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Destruction: 500 m/s2  
Vibration resistance  
Shock resistance  
Ambient temperature  
Ambient humidity  
Weight  
Operating: –25°C to 55°C (with no icing)  
Operating: 45% to 85%  
Approx. 65 g  
3
G6D-F4B/G3DZ-F4B  
Engineering Data  
Endurance  
Maximum Switching  
Power  
G6D-F4B  
500  
300  
100  
250 VAC/30 VDC resistive load  
50  
30  
DC resistive load AC resistive load  
10  
250 VAC/30 VDC inductive load  
(cosφ = 0.4, L/R = 7 ms)  
5
3
0
1
2
3
4
5
6
7
8
9
10  
Switching current (A)  
Switching voltage (V)  
Inrush Current Resistivity: Non-repetitive  
Load Current vs.  
Keep the inrush current to half the rated value if it occurs repetitively.  
Ambient Temperature  
G3DZ-F4B  
Energizing time (ms)  
Ambient temperature (°C)  
4
G6D-F4B/G3DZ-F4B  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
G6D-F4B  
G3DZ-F4B  
Mounting Dimensions  
16, M3 Phillips  
head screws  
Two, 4 dia. holes or M3.5 screw holes  
8.7  
Terminal Arrangement/  
Internal Connections  
(Top View)  
4
8
3
7
2
6
1
5
IN  
1
2
3
4
4
8
3
7
2
6
1
5
Input side  
68 max.  
76 0.3  
RY1 RY2 RY3 RY4  
OUT  
1
2
3
4
Output side  
12  
16  
11  
15  
10  
14  
9
12  
16  
11  
15  
10  
14  
9
13  
13  
8.7  
31 max.  
35 max.  
23 0.3  
Note1 : Make sure that the polarity of  
the input terminal is correct.  
Tool for removing relays.  
Note2 : There is no output polarity for  
the G6D-F4B and G3DZ-F4B.  
Accessories (Order Separately)  
G6D-4-SB Short Bar  
Applicable model  
Model  
G6D-4-SB  
G6D-F4B  
G3DZ-F4B  
Relay Mounting Products  
Short Bar  
Name  
Model  
PFP-100N  
Applicable Terminal Relay  
Model  
Mounting track  
G6D-F4B  
G6D-4-SB  
PFP-50N  
PFP-100N2  
PFP-M  
G3DZ-F4B  
End plate  
Spacer  
PFP-S  
Replacement Relays  
Applicable Terminal  
Relay  
Model  
Rated voltage  
G6D-F4B  
G6D-1A-ASI  
G3DZ-2R6PL  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
G3DZ-F4B  
Note: Error rate (P level) for the G6D-1A-ASI is 5 V at 10 mA and that  
for the G6D-1A-AP is 5 V at 1 mA.  
5
G6D-F4B/G3DZ-F4B  
Safety Precautions  
Refer to Safety Precautions for All Relays.  
Wiring  
Wiring  
Be sure to turn OFF the power when wiring the Unit and do not touch  
the charged terminals of the Unit. Otherwise, an electric shock may  
result.  
Pay utmost attention not to make mistakes with the polarity of the  
input terminals.  
Do not apply overvoltage to the input terminals. Otherwise, the Unit  
may malfunction or burn.  
Coil Voltage  
Make sure not to impose voltage exceeding the permissible voltage  
on the coil continuously.  
Relay Models  
Do not connect the Unit to loads exceeding the rated switching power  
(switching voltage or current). Otherwise, faulty insulation, contact  
weld, or faulty contact of Relays, or damage to Relays may result, or  
the Relays may malfunction or burn.  
Do not connect any inductive load in parallel to the coil input as  
shown in the following example or power supply with a surge voltage.  
Otherwise, the surge absorption diode will be damaged.  
Do Not Use the Following Circuit  
The life of Relays varies with the switching condition. Test the Relays  
under the actual operating conditions before using the Relays within  
the permissible switching frequency. The use of deteriorated Relays  
may result in the faulty insulation of the Relays or cause the Relays  
to burn.  
Coil surge  
absorption  
diode  
Inductive load  
G6D coil  
Do not use the Unit in locations with inflammable gas. Otherwise, a  
fire or explosion due to the heat of the Relays or sparks from the  
Relays may result when they are switched.  
SSR Output (Power MOS FET Relay  
Model)  
Do not connect the Unit to loads consuming a total current exceeding  
the rated output current of the Unit. Otherwise, the output element of  
the Unit may be damaged and a short or open-circuit malfunction  
may result.  
Handling  
Do not drop, shock, or vibrate the Unit excessively. Otherwise, dam-  
age to the Unit may result or the Unit may malfunction.  
Make sure that all the Relays are properly mounted before use.  
Screw Tightening Torque  
Tighten each terminal screw to a torque described below.  
M3 terminal screw: 0.4 to 0.56 N·m.  
If the Unit is connected to a DC inductive load, connect a diode to the  
Unit to protect the Unit from counter-electromotive voltage, otherwise  
the counter-electromotive voltage may damage the output element  
and a short or open-circuit malfunction may result.  
M3.5 terminal screw: 0.78 to 1.18 N·m.  
Tighten each mounting screw to a torque of 0.59 to 0.98 N·m.  
Correct Use  
Installation Environment  
Do not install the Unit in the following locations. Otherwise, damage  
to the Unit may result or the Unit may malfunction.  
Mounting  
When mounting two or more Units, reduce the current and ON duty  
and provide an appropriate distance between the Units so that the  
ambient temperature will not exceed 55°C.  
Locations with direct sunlight.  
Locations with an ambient temperature range not within –25°C to  
55°C.  
Relay Replacement  
Use the Relay Removal Tool provided with the Unit to dismount a  
Relay.  
Locations with rapid temperature changes resulting in condensation  
or locations with relative humidity ranges not within 45% to 85%.  
Locations with corrosive or inflammable gas.  
Be sure to turn OFF the power to the Unit before replacing a Relay.  
Locations with excessive dust, salinity, or metal powder.  
Locations with vibration or shock affecting the Unit.  
Locations with water, oil, or chemical sprayed on the Unit.  
When mounting a Relay, insert the Relay vertically so that the relay  
terminals will come in contact with the socket contact pins properly.  
Do not mount Relays that are different to one another in voltage.  
Disassembly, Repair, and Modification  
Do not disassemble, repair, or modify the Unit. Otherwise, an electric  
shock may result or the Unit may malfunction.  
Mounted Relays  
Relays and SSRs cannot be mounted together.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
6
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2015.10  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2015 All Right Reserved.  

相关型号:

G3DZ2R6PLDC12

SSR Identical to the G6D in Size with a Maximum AC/DC Switching Current of 0.6 A
OMRON

G3F-202SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3F-203S-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3F-203SL-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3F-203SLN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3F-203SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-102S-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-102SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-X03S-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3FD-X03SN-VD

International Standards for G3F Series, Same Profile as MY Power Relays
OMRON

G3G

GLASS PASSIVATED JUNCTION RECTIFIER
VISHAY

G3G146-AB72-01

FAN BLWR CENT 226.8X130MM 115VAC
EBMPAPST