PXI-2593 [NI]
500 MHz bandwidth/50 OHM characteristic impedance; 500 MHz带宽/ 50欧姆的特性阻抗型号: | PXI-2593 |
厂家: | National Instruments |
描述: | 500 MHz bandwidth/50 OHM characteristic impedance |
文件: | 总4页 (文件大小:535K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
High-Frequency Multiplexer/Matrix Modules
NI PXI-2593, NI PXIe-2593, NI SCXI-1193 NEW!
■
500 MHz bandwidth
50 Ω characteristic impedance
10 W RF carry power
Operating Systems
Windows XP/2000/Me/9x/NT
■
■
■
■
■
■
■
Recommended Software
150 V, CAT I switching
■
LabVIEW
Fully software configurable
Unterminated multiplexer
Available in both PXI and PXI Express
versions for optimal slot placement
LabWindows™/CVI
■
■
Measurement Studio
for Visual C++
NI Switch Executive
■
Configurations
NI SCXI-1193: 32x1, dual 16x1,
Other Compatible Software
■
■
Visual Basic
ANSI C/C++
quad 8x1, nine 3x1
NI PXI-2593/ NI PXIe-2593 (NI 2593):
■
■
Driver/Software (included)
16x1, dual 8x1, quad 3x1
■
NI-SWITCH
■
Terminated multiplexer configurations
■
NI SCXI-1193: 16x1, dual 8x1,
quad 4x1
■
NI 2593: 8x1, dual 4x1
Sparse matrix configurations
NI SCXI-1193: 36-terminal
NI 2593: 18-terminal
■
■
■
Overview and Applications
NI SCXI-1193
NI 2593
Unterminated
Multiplexer
Topology
NI PXI-2593, PXIe-2593, and SCXI-1193 are high-density 50 Ω RF relay modules.
You can programmatically configure them as unterminated multiplexers,
externally terminated multiplexers, or dimensionally flexible sparse matrices.
Each configuration handles signal frequencies from DC to beyond 500 MHz.
These single-slot switch modules use high-density push-on MCX connectors
for discrete yet manageable cabling. NI 2593 modules are designed to integrate
with high-frequency instruments such as the NI PXI-5404 frequency generator
and the NI PXI-5112 high-speed digitizer.
Unterminated
Terminated
–
Terminated
32x1
16x1
8x1
1 bank
2 banks
4 banks
–
–
–
–
1 bank
2 banks
4 banks
–
1 bank
2 banks
–
1 bank
2 banks
–
4x1
3x1
9 banks
4 banks
Table 1. This table shows available multiplexer configurations.
Dimensionally Flexible Sparse Matrix Configurations
You can configure the NI 2593 modules as flexible sparse matrices, which
you can use to route signals between any pair of channels or commons
while maintaining >500 MHz bandwidth and minimizing reflections. Unlike a
traditional sparse matrix made from two multiplexers with their COM terminals
connected, these modules use a flexible architecture in which you can define
the row and column dimensions. There is no restriction on row-to-row or
column-to-column connections. For example, you can configure the 18 terminals
on the NI 2593 modules as a 2x16, 4x14, or 9x9 sparse matrix, or any size in
between. It is even possible to connect multiple crosspoints simultaneously.
Figure 1 demonstrates the configuration capabilities of an NI 2593 as a
dimensionally flexible sparse matrix.
Multiplexer Configurations
The NI 2593 and SCXI-1193 are 16- and 32-channel unterminated multiplexers,
respectively. With external 50 Ω MCX terminators (P/N: 761930-01) on half of
the channels, you can use these modules as terminated multiplexers. Table 1
shows multiplexer configurations for each module.
High-Frequency Multiplexer/Matrix Modules
System Integration
Ordering Information
The NI 2593 modules have a flexible scan list architecture that can reduce
overall data acquisition and test time. A scan list delivers the fastest scan
possible by providing a hardware-timed solution. You can configure the module
to process the scan list once or to continuously loop through the scan list.
Commands in the scan list can open or close relays, wait for an external trigger,
and generate a scanner advanced trigger. The external trigger, sourced by
an instrument, such as an NI PXI-5411 arbitrary waveform generator, causes
the switch module to advance to the next entry in the scan list. The scanner
advanced trigger indicates when the module has closed all specified relays
and the relays have settled. The scanner advanced trigger is typically connected
to a measurement device, such as the NI PXI-4070 FlexDMM, which is
configured to take a reading upon receiving the trigger.
NI PXI-2593 ....................................................................................778793-01
NI PXIe-2593 ................................................................................ 780587-93
NI SCXI-1193 .................................................................................776572-93
Includes NI-SWITCH driver software.
Recommended Accessory
50 Ω MCX terminator ....................................................................778831-01
NI Switch Executive
Development system......................................................................778546-01
Deployment engine........................................................................778548-00
BUY NOW
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/switches.
Software
All National Instruments PXI and SCXI switch modules are shipped with
NI-SWITCH, an IVI-compliant driver that offers complete functionality for all
switch modules. For additional assistance in configuring, programming, and
managing higher-channel- count switching systems, NI Switch Executive
software provides an easy-to-use intelligent switch management and visual
routing environment.
0
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15
COM 0
COM 1
2x16 Sparse Matrix
COM 0
0
15
1
COM 0
1
2
3
4
5
7
COM 1
6
8
9 10 11 12 13 14 15
14
2
13
0
4
8
4x14 Sparse Matrix
3
4
12
12
NI 2593
Dual 8x1 Multiplexer
11
COM 1 9 10 11 12 13 14 15
8
5
COM 0
10
6
0
1
2
3
4
5
6
7
9
8
7
COM 1
9x9 Sparse Matrix
Figure 1. NI 2593 Configuration Capabilities as a Dimensionally Flexible Sparse Matrix
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
High-Frequency Multiplexer/Matrix Modules
Dynamic Characteristics
Specifications
Maximum scan rate .............................. 100 operations/s
Specifications subject to change without notice. Visit ni.com/manuals for
the latest full specifications.
Expected relay life
Mechanical....................................... 5x107 operations
Electrical........................................... 3x105 operations
RF Performance Characteristics
Characteristic impedance (Z0) .............. 50 Ω nominal
Insertion loss
(30 V, 0.3 ADC resistive)
Physical Characteristics
8x1
Relay type ............................................. Electromechanical, latching
Relay contact material ......................... Silver palladium and gold
I/O connectors
DC to 200 MHz ............................ <0.9 dB
200 to 500 MHz ........................... <1.6 dB
16x1
NI 2593 ............................................. 18 MCX jacks
NI SCXI-1193 .................................... 36 MCX jacks
Trigger connectors............................ 2 SMB jacks
Dimensions
DC to 200 MHz ............................ <1.2 dB
200 to 500 MHz ........................... <1.9 dB
32x1 (SCXI-1193 only)
DC to 200 MHz ............................ <1.4 dB
200 to 500 MHz ........................... <2.4 dB
Typical bandwidth (3 dB)
NI 2593 ............................................. 13 by 21.7 cm (5. by 8.6 in.)
NI SCXI-1193 .................................... 3.0 by 17.3 by 19.6 cm
(1.2 by 6.7 by 7.6 in.)
8x1 ............................................... >900 MHz
16x1 ............................................. >750 MHz
32x1 (SCXI-1193 only) ................. >600 MHz
VSWR
Weight
NI 2593 ............................................. 330 g (12 oz)
NI SCXI-1193 .................................... 960 g (2 lb, 2 oz)
8x1
Environment
DC to 200 MHz ............................ <1.4
200 to 500 MHz ........................... <1.8
16x1
Operating temperature.......................... 0 to 50 °C
Storage temperature............................. - 20 to 70 °C
Relative humidity .................................. 5 to 85% noncondensing
DC to 200 MHz ............................ <1.4
00 to 500 MHz ............................. <1.8
32x1 (SCXI-1193 only)
Pollution degree....................................
Approved at altitudes up to 2,000 m.
2
DC to 200 MHz ............................ <1.4
200 to 500 MHz ........................... <1.8
Maximum RF carry power .................... 10 W up to 500 MHz (per channel)
Safety Compliance
■
IEC 61010-1, EN 61010-1
■
UL 61010-01, CSA 61010-1
Input Characteristics
Electromagnetic Compatibility
Maximum switching voltage................. 150 V, CAT I
Maximum switching current................. 0.5 A (per channel)
Maximum carry current......................... 1 A (per channel)
Simultaneous channels at maximum current
NI 2593 ............................................. up to 2
NI SCXI-1193 .................................... up to 4
DC path resistance
This product meets the requirements of the following EMC standards for
electrical equipment for measurement, control, and laboratory use:
■
EN 61326 (IEC 61326): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
■
■
■
■
ICES-001: Class A emissions
Note: For EMC compliance, operate this product according to the documentation.
Initial................................................. <1.0 Ω
End of life.......................................... ≥2.0 Ω
CE Compliance
This product meets the essential requirements of applicable
European Directives as follows:
■
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
■
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within NI
Developer Exchange forums. Find immediate answers to your questions at
ni.com/support.
I
your needs around the globe and through
A
the application life cycle – from planning
and development through deployment and
SERVICE
NEEDS
ongoing maintenance. We offer services
and service levels to meet customer
requirements in research, design, validation,
and manufacturing.
P
E
V
Y
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Visit ni.com/ssp.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our products.
NI training can shorten your learning curve, save development time, and reduce
maintenance costs over the application life cycle. We schedule instructor-led
courses in cities worldwide, or we can hold a course at your facility. We also
offer a professional certification program that identifies individuals who have
high levels of skill and knowledge on using NI products.
Hardware Services
System Assurance Programs
NI system assurance programs are designed to make it even easier for you
to own an NI system. These programs include configuration and deployment
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic
System Assurance Program provides a simple integration test and ensures that
your system is delivered completely assembled in one box. When you configure
your system with the NI Standard System Assurance Program, you can select
from available NI system driver sets and application development environments
to create customized, reorderable software configurations. Your system arrives
fully assembled and tested in one box with your software preinstalled. When
you order your system with the standard program, you also receive system-
specific documentation including a bill of materials, an integration test report,
a recommended maintenance plan, and frequently asked question documents.
Finally, the standard program reduces the total cost of owning an NI system
by providing three years of warranty coverage and calibration service. Use the
online product advisors at ni.com/advisor to find a system assurance program
to meet your needs.
Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications and systems
engineers and a worldwide National Instruments Alliance Partner program of
more than 600 independent consultants and integrators. Services range from
start-up assistance to turnkey system
integration. Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you want to
use our products for OEM applications. For information about special pricing and
services for OEM customers, visit ni.com/oem.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for high-
accuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and
advance replacement services are also available. We offer extended warranties
to help you meet project life-cycle requirements. Visit ni.com/services.
■
ni.com 800 813 3693
■
National Instruments info@ni.com
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks
of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and
company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership,
or joint-venture relationship with National Instruments. 2009-11143-101-D
©2020 ICPDF网 联系我们和版权申明