ASA2810D_15 [INFINEON]
HYBRID-HIGH RELIABILITY DC-DC CONVERTER;型号: | ASA2810D_15 |
厂家: | Infineon |
描述: | HYBRID-HIGH RELIABILITY DC-DC CONVERTER DC-DC转换器 |
文件: | 总5页 (文件大小:110K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD-97609
ASA2810D
(IR P/N 10208)
28V Input, Dual Output
HYBRID-HIGH RELIABILITY
DC-DC CONVERTER
Description
The ASA28XXD Series of DC-DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feed back
circuits.
ASA
Features
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
n Up To 5.0W Output Power
n High Reliability
n Wide Input Voltage Range -16V To 40V
n Indefinite Short Circuit and Overload Protection
n Popular Industry Standard Pin-Out
n Military Screening
n Parallel Seam Welded Package
n No External Capacitors Required
n Input Voltage Surge Protected to MIL-STD-704
n Under Voltage Lockout
This device is designed to meet MIL-STD-704 input
requirement offering full performance over a 16V to
40V input range. Output Power of up to 5W is available
for either balanced or unbalanced loads.
Connecting the Inhibit pin (pin 5) to the Input Return
(pin 7) will cause the converter to shut down. It is
recommended that the Inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the Inhibit pin is 11.5 ± 0.5V.
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Extensive computer simulation
using complex modeling enables rapid design
modification to be provided. Contact IR San Jose with
specific requirements.
www.irf.com
1
12/14/10
ASA2810D (10208)
Specifications
Absolute Maximum Ratings
Input voltage
-0.5V to +50VDC Continous, 80V, 100 msec
Internally limited ( 6.5W typical )
300°C for 10 seconds
Power output
Soldering temperature
Operating case temperature
Storage case temperature
-55°C to +125°C
-65°C to +135°C
TEST
Conditions
ASA2810D/XX
Unit
-55° ≤ TC ≤+125°C
IN = 28V dc ±5% CL = 0
Group A
Subgroups
V
Min
Max
unless otherwise specified
Output voltage
Output current
IOUT = 0
1
±9.90
±9.80
100
±10.10
±10.20
400
V
2, 3
1, 2
VIN = 16, 28, and 40Vdc
either output
1, 2, 3
mA
3, 4
Output ripple voltage
VIN = 16, 28 and 40Vdc
I
OUT = 50% IMAX
1, 2, 3
1, 2, 3
1, 2, 3
120
200
mV PP
mV
mV
%
IOUT = 100% IMAX
4
Line regulation
VIN = 16, 28, and 40Vdc
IOUT = 0, 50%, 100% IMAX
50
4
Load regulation
VIN = 16, 28, and 40Vdc
I
50
OUT = 0, 50%, 100% IMAX
5
Cross regulation
20% to 80% load change
1, 2, 3
1, 2, 3
8.0
12
Input current
IOUT = 0
Pin 5 connected to pin 7
mA
I
OUT = 0 Pin 5 open
60
3, 4
Input ripple current
IOUT = IMAX
IOUT = IMAX
1, 2, 3
100
mA PP
%
4
Efficiency
1, 3
2
71
68
Isolation
Input to output or any pin to case
(except pin 8) at 500Vdc, Tc = 25°C
1
100
Ω
M
6, 7
Capacitive load
No effect on dc performance, total
for both outputs
4
200
µF
8
Power dissipation load fault
Overload
1, 2, 3
4.0
2.0
W
Short circuit
IOUT = IMAX
4
Switching frequency
4, 5, 6
4, 5, 6
500
600
+400
KHz
Output response to step
transient load changes
IOUT = 50%
100% IMAX
-400
4, 9
mV pk
IOUT = 0
50% IMAX
100% IMAX
-800
+800
100
Recovery time, step transient
IOUT = 50%
4, 5, 6
4, 9, 10
load changes
µs
IOUT = 0
50% IMAX
2000
+750
Output response transient step
VIN =16 40Vdc,IOUT= IMAX
4, 5, 6
4, 5, 6
- 750
mV pk
4, 7, 11
line changes
Recovery time transient step
VIN=16 40Vdc, IOUT= IMAX
1200
µ
s
4, 7, 10, 11
line changes
4
Turn on overshoot
IOUT = 0 and IMAX
IOUT = 0 and IMAX
4, 5, 6
4, 5, 6
4, 5, 6
600
25
mV pk
ms
4, 12
Turn on delay
7
Load fault recovery
25
ms
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA2810D (10208)
Notes to Specifications
1.
2.
3.
4.
5.
6.
Parameter guaranteed by line, load, and cross regulation tests.
Up to 80% of full power is available from either output provided the total output does not exceed 5W.
Bandwidth of DC to 20MHz is guaranteed by design. Tested for 20KHz to 2MHz.
Load current split equally between +VOUT and -VOUT
.
1.0W load on output under test, 1.0W to 4.0W load change on other output.
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7.
8.
9.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
Load step transition time between 2µs and 10µs.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
11. Input step transition time between 2µs and 10µs.
12. Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
Block Diagram
+Output
+Input
1
6
Output
Return
2
-Output
3
Error
Amplifier
Input
Return
Case
7
8
Inhibit
5
Controller
www.irf.com
3
ASA2810D (10208)
Mechanical Outline
1.075
0.800
0.270
1
2
3
4
5
0.800
±.005
1.075
8
7
6
0.025 ± .003 Dia Pins
0.220
Pin Designation
Pin #
Designation
1
2
3
4
5
6
7
8
+ Output
Output Return
- Output
NC
Inhibit
+ Input
Input Return
Case Ground
4
www.irf.com
ASA2810D (10208)
Device Screening
Requirement
MIL-STD-883 Method No Suffix
ES
HB
CH
Temperature Range
Element Evaluation
Non-Destructive
Bond Pull
-20°C to +85°C -55°C to +125°C
-55°C to +125°C -55°C to +125°C
MIL-PRF-38534
2023
N/A
N/A
N/A
Class H
N/A
N/A
N/A
N/A
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
2017
1010
Yes
Cond B
500 Gs
N/A
Yes
Cond C
3000 Gs
N/A
Yes
Cond C
3000 Gs
N/A
N/A
N/A
2001, Y1 Axis
2020
N/A
Burn-In
1015
N/A
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
25°C
25°C
-55°C, +25°C,
+125°C
N/A
-55°C, +25°C,
+125°C
10%
PDA
N/A
Cond A
N/A
N/A
Cond A, C
N/A
Seal, Fine and Gross
Radiographic
External Visual
Notes:
Cond A, C
N/A
Cond A, C
N/A
2012
2009
Yes
Yes
Yes
Best commercial practice
Sample tests at low and high temperatures
-55°C to +105°C for AHE, ATO, ATW
Part Numbering
Part Definition
IR P/N 10208EM = ASA2810D/ES
IR P/N 10208FM = ASA2810D/HB
ASA 28 10 D /CH
Screening Level
Model
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Input Voltage
28 = 28V
Output Voltage
10 = 10V
Output
D = Dual
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SAN JOSE: 2520Junction Avenue, San Jose, California 95134, Tel: (408) 434-5000
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 12/2010
www.irf.com
5
相关型号:
ASA2812D
DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid, 1.065 X 1.075 X 0.270 INCH, PACKAGE-8
INFINEON
©2020 ICPDF网 联系我们和版权申明