ASA2812D [INFINEON]

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid, 1.065 X 1.075 X 0.270 INCH, PACKAGE-8;
ASA2812D
型号: ASA2812D
厂家: Infineon    Infineon
描述:

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid, 1.065 X 1.075 X 0.270 INCH, PACKAGE-8

输出元件
文件: 总4页 (文件大小:33K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PD - 94540  
ASA28XXD SERIES  
28V Input, Dual Output  
ADVANCED ANALOG  
HIGH RELIABILITY  
HYBRID DC/DC CONVERTERS  
Description  
The ASA28XXD Series of DC/DC converters are high  
reliability thick film hybrid converters that use flyback  
topology operating at a nominal frequency of 550Khz.  
High input to output isolation is achieved through the  
use of transformers in the flyback power and feedback  
circuits.  
ASA  
Features  
The advanced feedback design provides fast loop re-  
sponse for superior line and load transient characteris-  
tics and offers greater reliability than devices incorpo-  
rating optical feedback circuits.  
n Up To 5 Watt Output Power  
±5, ±12, ±15 Volts Outputs  
n
n High Reliability  
n Wide Input Voltage Range -16 To 40 Volts  
n Indefinite Short Circuit and Overload  
Protection  
n Popular Industry Standard Pin-Out  
n Military Screening  
This device is designed to meet MIL-STD-704 input  
requirements offering full performance over a 16 to 40  
volt input range. Output Power of up to 5 watts is avail-  
able for either balanced or unbalanced loads.  
n Parallel Seam Welded Package  
n No External Capacitors Required  
n Input Voltage Surge Protected to  
MIL-STD-704  
Connecting the inhibit pin (pin 5) to the input common  
(pin 7) will cause the converter to shut down. It is rec-  
ommended that the inhibit pin be driven by an open  
collector device capable of sinking at least 400µA. The  
open circuit voltage of the inhibit pin is 11.5 ±0.5 volts.  
n Under Voltage Lockout  
These converters are manufactured in a facility fully  
qualified to MIL-PRF-38534. All processes used to  
manufacture these converters have been qualified to  
enable Advanced Analog to deliver compliant devices.  
Three standard temperature grades are offered with  
the screening options. Refer to Part Number section.  
The CH grade converters are fully compliant to MIL-  
PRF-38534 for class H. The HB grade converters are  
processed with the same screening as the CH grade,  
but do not have class H element evaluation as required  
by MIL-PRF-38534. These two grades are fully tested  
and operate over the full military temperature range  
without derating of output power. A commercial grade  
is also available. Variations in electrical, mechanical  
and screening can be accommodated. Extensive com-  
puter simulation using complex modeling enables rapid  
design modification to be provided. Contact  
Advanced Analog with specific requirements.  
www.irf.com  
1
09/12/02  
ASA28XXD Series  
Specifications  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Power Output  
-0.5 V to 50 V Continuous. 80 V, 100 mSec  
Internally limited (6.5 W typical)  
300°C for 10 Sec.  
Soldering  
Temperature Range  
Operating  
Storage  
-55°C to +125°C Case  
-65°C to +150°C  
Conditions  
-55° TC +125°C  
VIN = 28V dc ±5% CL = 0  
unless otherwise specified  
ASA2805D/XX  
ASA2812D/XX  
ASA2815D/XX  
Group A  
Subgroups  
Min  
Max  
Min  
Max  
Min  
Max  
TEST  
Unit  
V
1
±4.95  
±4.90  
±5.05  
±5.10  
±11.88  
±11.76  
±12.12  
±12.24  
±14.85  
±14.70  
±15.15  
±15.30  
Output voltage  
IOUT = 0  
2, 3  
1, 2  
Output current  
VIN = 16, 28, and 40 V dc  
either output  
1, 2, 3  
200  
1000  
84  
333  
67  
267  
mA  
3, 4  
1, 2, 3  
1, 2, 3  
470  
50  
200  
50  
290  
50  
Output ripple voltage  
VIN = 16, 28 and 40 V dc  
mV P  
mV  
P
4
Line regulation  
VIN = 16, 28, and 40 V dc  
IOUT = 0, 50%, 100% IMAX  
4
1, 2, 3  
50  
15  
50  
50  
mV  
Load regulation  
VIN = 16, 28, and 40 V dc  
IOUT = 0, 50%, 100% IMAX  
5
20% to 80% load change  
1, 2, 3  
1, 2, 3  
8.0  
8.0  
%
Cross regulation  
IOUT = 0  
Pin 5 connected to pin 7  
12  
60  
12  
60  
12  
60  
Input current  
mA  
I
OUT = 0 Pin5 open  
IOUT = IMAX  
IOUT = IMAX  
3, 4  
1, 2, 3  
100  
100  
100  
Input ripple current  
mA PP  
%
4
1, 3  
2
70  
66  
71  
68  
71  
68  
Efficiency  
Isolation  
Input to output or any pin to  
case (except pin 8) at 500 V  
dc, Tc = +25° C  
1
100  
200  
100  
100  
MΩ  
6, 7  
No effect on dc performance,  
total for both outputs  
Capacitive load  
4
200  
4.0  
200  
4.0  
µf  
8
Power dissipation load fault  
4.0  
Overload  
1, 2, 3  
4, 5, 6  
W
Short circuit  
IOUT = IMAX  
2.0  
2.0  
2.0  
4
500  
600  
500  
600  
500  
600  
KHz  
Switching frequency  
-400  
+400  
-400  
+400  
-400  
+400  
IOUT = 50% ó 100% IMAX  
Output response to step  
4, 9  
4, 5, 6  
mV pk  
transient load changes  
-800  
+800  
100  
-800  
+800  
100  
-800  
+800  
100  
IOUT = 0 ó 50% IMAX  
IOUT = 50% ó 100% IMAX  
ó
Recovery time, step  
4, 5, 6  
4, 5, 6  
4, 5, 6  
µS  
mV pk  
µS  
transient load changes  
4, 9, 10  
2000  
+750  
2000  
2000  
IOUT = 0  
50% IMAX  
Output response transient  
4, 7, 11  
step line changes  
-750  
- 750  
+750  
1200  
-750  
+750  
1200  
V
IN = 16 ó 40Vdc,IOUT= IMAX  
Recovery time transient step  
1200  
line changes  
VIN = 16 ó 40Vdc, IOUT= IMAX  
4, 7, 10, 11  
4
4, 5, 6  
4, 5, 6  
4, 5, 6  
600  
25  
600  
25  
600  
25  
mV pk  
ms  
Turn on overshoot  
IOUT = 0 and IMAX  
IOUT = 0 and IMAX  
4, 12  
Turn on delay  
7
25  
25  
25  
ms  
Load fault recovery  
For Notes to Specifications, refer to page 3  
2
www.irf.com  
ASA28XXD Series  
Notes to Specifications  
1.  
2.  
3.  
4.  
5.  
6.  
Parameter guaranteed by line, load, and cross regulation tests.  
Up to 80 percent of full power is available from either output provided the total output does not exceed 5 W.  
Bandwidth of DC to 20 MHz is guaranteed by design. Tested for 20 KHz to 2 MHz.  
Load current split equally between +VOUT and -VOUT  
.
1.0 watt load on output under test, 1.0 to 4.0 watt load change on other output.  
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess  
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,  
appearing as a short circuit during turn-on.  
7.  
8.  
9.  
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall  
be guaranteed to the limits specified.  
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is  
the condition of maximum power dissipation.  
Load step transition time between 2 and 10 microseconds.  
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50  
percent load.  
11. Input step transition time between 2 and 10 microseconds.  
12. Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from  
enable pin (pin 5) with power applied to the input.  
Available Screening Levels and ProcessVariations for ASA28XXD Series  
MIL-STD-883  
Method  
No  
ES  
HB  
CH  
Requirement  
Temperature Range  
Element Evaluation  
Internal Visual  
Suffix  
Suffix  
Suffix  
Suffix  
-20°C to +85°C  
-55°C to +125°C  
-55°C to +125°C  
-55°C to +125°C  
MIL-PRF-38534  
ü
2017  
1010  
¬
ü
Cond B  
500g  
ü
Temperature Cycle  
Constant Acceleration  
Burn-in  
Cond C  
Cond C  
2001,  
Cond A  
Cond A  
1015  
48hrs @ 85°C  
25°C  
48hrs @ 125°C  
25°C  
160hrs @ 125°C  
160hrs @ 125°C  
Final Electrical (Group A)  
Seal, Fine & Gross  
External Visual  
MIL-PRF-38534  
1014  
-55, +25, +125°C -55, +25, +125°C  
Cond C  
¬
Cond A, C  
ü
Cond A, C  
Cond A, C  
2009  
ü
ü
* per Commercial Standards  
Available Standard Military Drawing (SMD) Cross Reference  
ASA2812D/CH  
ASA2815D/CH  
5962-9564801  
5962-9464901  
Part Numbering  
ASA 28 05 D / CH  
Model  
Screening  
, ES, HB, CH  
Input Voltage  
28 = 28V  
Output Voltage  
Outputs  
S = Single  
D = Dual  
5 = ±5, 12 = ±12,  
15 = ±15  
www.irf.com  
3
ASA28XXD Series  
ASA28XXD Block Diagram  
+Output  
1
6
+Input  
Return  
2
-Output  
3
Error  
Amplifier  
Return  
7
Case  
8
Enable  
5
Controller  
ASA28XXD Case Outline  
ASA28XXD Pin Designation  
Pin No.  
Designation  
1.075  
0.800  
1
2
3
4
5
6
7
8
Positive Output  
Output Return  
Negative Output  
N/C  
0.270  
1
2
3
4
5
0.800  
±.005  
Enable  
1.075  
Positive Input  
Input Return  
Case  
8
7
6
0.025 ± .003 Dia Pins  
0.220  
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331  
ADVANCED ANALOG: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500  
Visit us at www.irf.com for sales contact information.  
Data and specifications subject to change without notice. 09/02  
4
www.irf.com  

相关型号:

ASA2812D-CH

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812D-ES

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812D-HB

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812D/CH

HYBRID-HIGH RELIABILITYDC/DC CONVERTER
INFINEON

ASA2812D/ES

HYBRID-HIGH RELIABILITYDC/DC CONVERTER
INFINEON

ASA2812D/HB

HYBRID-HIGH RELIABILITYDC/DC CONVERTER
INFINEON

ASA2812D/HBPBF

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
INFINEON

ASA2812S

HYBRID-HIGH RELIABILITY HYBRID-HIGH RELIABILITY
INFINEON

ASA2812S-CH

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S-ES

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S-HB

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S/CH

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON