ASA2812D/HBPBF [INFINEON]

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid;
ASA2812D/HBPBF
型号: ASA2812D/HBPBF
厂家: Infineon    Infineon
描述:

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid

文件: 总4页 (文件大小:74K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
l
LAMBDA ADVANCED ANALOG INC.  
ASA2800D Series  
Hybrid - High Reliability  
Dual Output DC/DC Converter  
DESCRIPTION  
FEATURES  
The ASA2800D Series of DC/DC converters are high  
reliability thick film hybrid converters that use flyback  
topology operating at a nominal frequency of 550KHz.  
High input to output isolation is achieved through the  
use of transformers in the flyback power and  
feedback circuits.  
n
n
n
n
n
Up to 5 watt output power  
±5, ±12, ±15 volt outputs  
High reliability  
Wide input voltage range – 16 to 40 volts  
Indefinite short circuit and overload  
protection  
The advanced feedback design provides fast loop  
response for superior line and load transient  
characteristics and offers greater reliability than  
devices incorporating optical feedback circuits.  
n
n
n
n
n
n
Popular industry standard pin-out  
Military screening  
Parallel seam welded package  
No external capacitors required  
Input voltage surge protected to MIL-STD-704  
Under Voltage Lockout  
This device is designed to meet MIL-STD-704 input  
requirements offering full performance over a 16 to  
40 volt input range. Output Power of up to 4 watts is  
available for either balanced or unbalanced loads.  
Connecting the inhibit pin (pin 5) to the input common  
(pin 7) will cause the converter to shut down. It is  
recommended that the inhibit pin be driven by an  
open collector device capable of sinking at least  
400ua. The open circuit voltage of the inhibit pin is  
11.5 +/-0.5 volts.  
These converters are manufactured in a facility fully  
qualified to MIL-PRF-38534. All processes used to  
manufacture these converters have been qualified to  
enable Lambda Advanced Analog to deliver  
compliant devices.  
Three standard temperature  
grades are offered with the screening options. Refer  
to Part Number section. The CH grade converters  
are fully compliant to MIL-PRF-38534 for class H.  
The HB grade converters are processed with the  
same screening as the CH grade, but do not have  
class H element evaluation as required by MIL-PRF-  
38534. These two grades are fully tested and operate  
over the full military temperature range without  
derating of output power. A commercial grade is also  
available. Variations in electrical, mechanical and  
screening can be accommodated.  
Extensive  
computer simulation using complex modeling enables  
rapid design modification to be provided. Contact  
Lambda Advanced Analog with specific requirements.  
Specifications  
ASA2800D  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Power Output  
-0.5 V to 50 V Continuous. 80 V, 100 mSec  
Internally limited (6.5 w typical)  
300°C for 10 Sec.  
Soldering  
Temperature Range  
Operating  
Storage  
-55°C to +125°C Case  
-65°C to +150°C  
Conditions  
-55° £ TC £+125°C  
IN = 28V dc ±5% CL = 0  
unless otherwise specified  
ASA2805D/XX  
Limits  
ASA2812D/XX  
Limits  
ASA2815D/XX  
Limits  
Group A  
Subgroups  
V
Min  
Max  
Min  
Max  
Min  
Max  
TEST  
Unit  
V
1
±4.95  
±4.90  
±5.05  
±5.10  
±11.88  
±11.76  
±12.12  
±12.24  
±14.85  
±14.70  
±15.15  
±15.30  
Output voltage  
IOUT = 0  
2, 3  
1, 2  
Output current  
VIN = 16, 28, and 40 V dc  
either output  
1, 2, 3  
200  
1000  
84  
333  
67  
267  
mA  
3, 4  
Output ripple voltage  
VIN = 16, 28 and 40 V dc  
VIN = 16, 28, and 40 V dc  
1, 2, 3  
1, 2, 3  
470  
50  
200  
50  
290  
50  
mV PP  
mV  
4
Line regulation  
IOUT = 0, 50%, 100% IMAX  
4
Load regulation  
VIN = 16, 28, and 40 V dc  
OUT = 0, 50%, 100% IMAX  
1, 2, 3  
1, 2, 3  
1, 2, 3  
50  
15  
50  
50  
mV  
%
I
5
Cross regulation  
20% to 80% load change  
8.0  
8.0  
IOUT = 0  
Pin 5 connected to pin7  
12  
60  
12  
60  
12  
60  
Input current  
mA  
IOUT = 0 Pin5 open  
3, 4  
Input ripple current  
IOUT = IMAX  
1, 2, 3  
1, 3  
2
100  
100  
100  
mA PP  
%
4
70  
66  
71  
68  
71  
68  
Efficiency  
IOUT = IMAX  
Isolation  
Input to output or any pin to  
case (except pin 8) at 500 V  
dc, Tc = +25° C  
1
4
100  
200  
100  
100  
MW  
mf  
6, 7  
Capacitive load  
No effect on dc performance,  
total for both outputs  
200  
200  
8
Power dissipation load fault  
Overload  
4.0  
2.0  
600  
4.0  
2.0  
600  
4.0  
2.0  
600  
1, 2, 3  
4, 5, 6  
4, 5, 6  
W
Short circuit  
IOUT = IMAX  
4
Switching frequency  
500  
500  
500  
KHz  
IOUT = 50% ó100% IMAX  
-400  
+400  
-400  
+400  
-400  
+400  
Output response to step  
transient load changes  
4, 9  
mV pk  
IOUT = 0 ó50% IMAX  
-800  
+800  
100  
-800  
+800  
100  
-800  
+800  
100  
Recovery time, step transient  
IOUT = 50% ó100% IMAX  
4, 5, 6  
4, 5, 6  
4, 5, 6  
mS  
load changes  
4, 9, 10  
IOUT = 0 ó50% IMAX  
2000  
+750  
2000  
+750  
2000  
+750  
Output response transient  
step line changes  
VIN = 16 ó40 V dc, IOUT = IMAX  
-750  
- 750  
-750  
mV pk  
4, 7, 11  
Recovery time transient step  
VIN = 16 ó40 V dc, IOUT = IMAX  
1200  
1200  
1200  
mS  
line changes  
4, 7, 10, 11  
4
Turn on overshoot  
IOUT = 0 and IMAX  
IOUT = 0 and IMAX  
4, 5, 6  
4, 5, 6  
4, 5, 6  
600  
25  
600  
25  
600  
25  
mV pk  
ms  
4, 12  
Turn on delay  
7
Load fault recovery  
25  
25  
25  
ms  
Notes  
1.  
2.  
3.  
4.  
5.  
6.  
Parameter guaranteed by line, load, and cross regulation tests.  
Up to 80 percent of full power is available from either output provided the total output does not exceed 5 W.  
Bandwidth of DC to 20 MHz is guaranteed by design. Tested for 20 KHz to 2 MHz.  
Load current split equally between +VOUT and -VOUT  
.
1.0 watt load on output under test, 1.0 to 4.0 watt load change on other output.  
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess of the maximum limit will not disturb loop stability  
but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on.  
7.  
8.  
9.  
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified.  
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation.  
Load step transition time between 2 and 10 microseconds.  
10.  
11.  
12.  
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50 percent load.  
Input step transition time between 2 and 10 microseconds.  
Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from enable pin (pin 5) with power applied to the input.  
2
ASA2800D Block Diagram  
+Output  
1
6
+Input  
Return  
2
-Output  
3
Error  
Amplifier  
Return  
7
Case  
8
Enable  
5
Controller  
ASA2800D Case Outline  
1.075  
0.800  
0.270  
0.800  
1
2
3
4
5
1.075  
8
7
6
0.025 ± .003 Dia Pins  
0.220  
ASA2800D Pin Designation  
Pin No.  
Designation  
1
2
3
4
5
6
7
8
Positive Output  
Output Return  
Negative Output  
N/C  
Enable  
Positive Input  
Input Return  
Case  
3
Screening Levels and Performance Variations for ASA2800 Series Converters.  
MIL-STD-883  
Method  
No  
Suffix  
ES  
Suffix  
HB  
Suffix  
CH  
Suffix  
Requirement  
Temperature Range  
Element Evaluation  
Internal Visual  
-20°C to +85°C  
-55°C to +125°C  
-55°C to +125°C  
-55°C to +125°C  
MIL-PRF-38534  
ü
2017  
1010  
¬
ü
Cond B  
500g  
ü
Cond C  
Temperature Cycle  
Constant Acceleration  
Burn-in  
Cond C  
2001,  
Cond A  
Cond A  
1015  
96hrs @ 125°C  
25°C  
160hrs @ 125°C  
-55, +25, +125°C  
Cond A, C  
ü
160hrs @ 125°C  
-55, +25, +125°C  
Cond A, C  
ü
Final Electrical (Group A)  
Seal, Fine & Gross  
External Visual  
MIL-PRF-38534  
1014  
25°C  
Cond C  
¬
Cond A, C  
ü
2009  
¬per Commercial Standards  
Part Numbering/Ordering Information  
Model  
ASA 28 05 D / CH  
Screening  
, ES, HB, CH  
Input Voltage  
28 = 28V  
Output Voltage  
5 = ±5, 12 = ±12,  
15 = ±15  
Outputs  
S = Single  
D = Dual  
Available Standard Military Drawing (SMD) Cross Reference  
Lambda Advanced Analog Part No. Standard Military Drawing No.  
ASA2812D/CH  
ASA2815D/CH  
5962-95648  
5962-94649  
The information in this data sheet has been carefully checked and is believed to be accurate; however no  
responsibility is assumed for possible errors. These specifications are subject to change without notice.  
Ó
Lambda Advanced Analog  
9849  
2270 Martin Avenue  
Santa Clara CA 95050-2781  
(408) 988-4930 FAX (408) 988-2702  
MIL-PRF-38534 Certified  
ISO 9001 Registered  
l
LAMBDA ADVANCED ANALOG INC.  
4

相关型号:

ASA2812S

HYBRID-HIGH RELIABILITY HYBRID-HIGH RELIABILITY
INFINEON

ASA2812S-CH

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S-ES

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S-HB

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2812S/CH

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812S/ES

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812S/HB

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812S/HBPBF

DC-DC Regulated Power Supply Module, 1 Output, 5W, Hybrid
INFINEON

ASA2812SCH

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812SES

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812SHB

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2812SPBF

暂无描述
INFINEON