ASA2812SES [INFINEON]
HYBRID-HIGH RELIABILITY DC/DC CONVERTER;型号: | ASA2812SES |
厂家: | Infineon |
描述: | HYBRID-HIGH RELIABILITY DC/DC CONVERTER |
文件: | 总5页 (文件大小:104K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD-94539A
ASA28XXS SERIES
28V Input, Single Output
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
Description
The ASA28XXS Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feedback
circuits.
ASA
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
Features
ꢀ Up To 5.0W Output Power
ꢀ 5V, 12V,15V Outputs
ꢀ High Reliability
This device is designed to meet MIL-STD-704D input
requirements offering full performance over a 16V to
40V input range. Output Power of up to 5W is available.
ꢀ Wide Input Voltage Range -16V To 40V
ꢀ Indefinite Short Circuit and Overload Protection
ꢀ Popular Industry Standard Pin-Out
ꢀ Military Screening Available
ꢀ Parallel Seam Welded Package
ꢀ No External Capacitors Required
ꢀ Input Voltage Surge Protected to MIL-STD-704A
ꢀ Under Voltage Lockout
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is
recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ± 0.5V.
ꢀ Available as Standard Military Drawing
ꢀ Standard Microcircuit Drawings Available
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening
requirements can be accommodated. Extensive
computer simulation using complex modeling allows
design modifications to be examined. Contact IR Santa
Clara with specific requirements.
www.irf.com
1
01/11/07
ASA28XXS Series
Specifications
Absolute Maximum Ratings
Input voltage
-0.5V to +50VDC Continous, 80V, 100 msec
Internally limited ( 6.5W typical )
300°C for 10 seconds
Power output
Soldering temperature
Operating case temperature
Storage case temperature
-55°C to +125°C
-65°C to +135°C
Conditions
ASA2805S/xx
ASA2812S/xx
ASA2815S/xx
-55° ≤ TC ≤+125°C
VIN = 28V dc ±5% CL = 0
unless otherwise specified
Group A
Subgroups
Min
Max
Min
Max
Min
Max
TEST
Unit
V
1
4.95
4.90
5.05
5.10
11.88
11.76
12.12
12.24
14.85
14.70
15.15
15.30
Output voltage
IOUT = 0
2, 3
1
V
V
IN = 16, 28, and 40 V dc
IN = 16, 28 and 40 V dc
Output current
1, 2, 3
1
1000
190
475
25
417
333
200
290
±25
±50
±25
±50
18
mA
2
200
290
±25
±50
±25
±50
Output ripple voltage
Line regulation
mV
PP
2, 3
1
VIN = 16, 28, and 40 V dc
OUT = 0, 50%, 100% IMAX
mV
mV
I
2, 3
1
50
25
Load regulation
VIN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
2, 3
50
IOUT = 0 Pin 5 to Pin 7
18
18
50
1, 2, 3
1, 2, 3
mA
Input current
I
I
OUT = 0 Pin5 open
OUT = IMAX
50
50
2
100
100
100
Input ripple current
Efficiency
mA
PP
1
71
68
71
68
I
OUT = IMAX
66
%
2, 3
Isolation - Input to output
or any pin to case
VTEST 500 Vdc, Tc= +25°C
1
4
100
100
100
MΩ
µF
W
3, 4
No effect on dc
performance, Tc = +25°C
Capacitive load
500
200
200
5
4.0
2.0
4.0
2.0
4.0
2.0
Power dissipation, load
fault
Overload
1, 2, 3
Short circuit
4
I
OUT = IMAX
4, 5, 6
500
600
500
600
500
600
KHz
Switching frequency
4
-300
-450
-500
-750
+300
+450
+500
+700
200
Output response to step
transient load changes
½ IMAX ꢀ IMAX
0 mA ꢀ IMAX
-450
+450
+750
-400
+450
+750
6
5, 6
4
mV pk
-750
-800
5, 6
IOUT = IMAX
100
1.0
100
1.0
µs
Recovery time, step
transient load changes
4, 5, 6
4, 5, 6
0 mA ꢀ ½ IMAX
1.0
ms
ꢀ
Output response
transient step line
Input step 16
OUT = IMAX
40 V dc
40 V dc
500
1000
1000
mV pk
I
4
8
changes
Recovery time transient
ꢀ
Input step 16
IOUT = IMAX
4, 5, 6
800
800
800
µs
4, 7, 8
step line changes
Turn on overshoot
IOUT = 0 mA, IMAX
OUT = 0 or IMAX
4, 5, 6
4, 5, 6
600
20
600
25
600
25
mV pk
ms
9
I
Turn on delay
4
4, 5, 6
20
25
25
ms
Load fault recovery
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA28XXS Series
Notes to Specifications
1.
2.
3.
Parameter guaranteed and measured during line and load regulation tests.
Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
4.
5.
Parameter shall be tested as part of design characterization and after design or process changes.
An overload is that condition of load in excess of rated load but less than that necessary to trigger the short circuit protection
and is the condition of maximum power dissipation.
6.
7.
8.
9.
Load step transition time between 2µs and 10µs.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
Input step transition time between 2µs and 10µs.
Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.
Block Diagram
1
6
+Output
+Input
Output
Return
2
Error
Input
Amplifier
Return
Case
8
7
Inhibit
5
Controller
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit
Drawing Number
5962-94629
IR Standard
Part Number
ASA2805S
5962-94630
ASA2815S
5962-94631
ASA2812S
www.irf.com
3
ASA28XXS Series
Mechanical Outline
1.075
0.800
0.270
1
2
3
4
5
0.800
±.005
1.075
8
7
6
0.025 ± .003 Dia Pins
0.220
Pin Designation
Pin #
Designation
+ Output
Output Return
NC
1
2
3
4
5
6
7
8
NC
Inhibit
+ Input
Input Return
Case Ground
4
www.irf.com
ASA28XXS Series
Device Screening
ꢀ
Requirement
MIL-STD-883 Method No Suffix
ES
HB
CH
ꢀ
Temperature Range
Element Evaluation
Non-Destructive
Bond Pull
-20°C to +85°C -55°C to +125°C
-55°C to +125°C -55°C to +125°C
MIL-PRF-38534
2023
N/A
N/A
N/A
N/A
N/A
Class H
N/A
N/A
ꢁ
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
2017
1010
Yes
Cond B
500 Gs
N/A
Yes
Cond C
3000 Gs
N/A
Yes
Cond C
3000 Gs
N/A
N/A
N/A
N/A
N/A
25°C
2001, Y1 Axis
2020
Burn-In
1015
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C
ꢂ
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
25°C
-55°C, +25°C,
+125°C
N/A
-55°C, +25°C,
+125°C
10%
PDA
N/A
Cond A
N/A
N/A
Cond A, C
N/A
Seal, Fine and Gross
Radiographic
External Visual
Cond A, C
N/A
Cond A, C
N/A
2012
ꢁ
2009
Yes
Yes
Yes
Notes:
ꢀ Best commercial practice
ꢁ Sample tests at low and high temperatures
ꢂ -55°C to +105°C for AHE, ATO, ATW
Part Numbering
ASA 28 05 S /CH
Screening Level
Model
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Input Voltage
28 = 28V
Output Voltage
05 = 5V
12 = 12V
Output
S = Single
15 = 15V
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice.01/2007
www.irf.com
5
相关型号:
ASA2815DPBF
DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid, 1.065 X 1.075 X 0.270 INCH, PACKAGE-8
INFINEON
©2020 ICPDF网 联系我们和版权申明