ASA2812D/HB [INFINEON]
HYBRID-HIGH RELIABILITYDC/DC CONVERTER; HYBRID - HIGH RELIABILITYDC / DC转换器型号: | ASA2812D/HB |
厂家: | Infineon |
描述: | HYBRID-HIGH RELIABILITYDC/DC CONVERTER |
文件: | 总5页 (文件大小:106K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD-94540A
ASA28XXD SERIES
28V Input, Dual Output
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
Description
The ASA28XXD Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feed back
circuits.
ASA
Features
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
ꢀ Up To 5.0W Output Power
±5V, ±12V, ±15V Outputs
ꢀ High Reliability
ꢀ
ꢀ Wide Input Voltage Range -16V To 40V
ꢀ Indefinite Short Circuit and Overload Protection
ꢀ Popular Industry Standard Pin-Out
ꢀ Military Screening
ꢀ Parallel Seam Welded Package
ꢀ No External Capacitors Required
ꢀ Input Voltage Surge Protected to MIL-STD-704
ꢀ Under Voltage Lockout
This device is designed to meet MIL-STD-704 input
requirements offering full performance over a 16V to
40V input range. Output Power of up to 5W is available
for either balanced or unbalanced loads.
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is
recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ± 0.5V.
ꢀ Standard Microcircuit Drawings Available
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Extensive computer simulation
using complex modeling enables rapid design
modification to be provided. Contact IR Santa Clara
with specific requirements.
www.irf.com
1
01/11/07
ASA28XXD Series
Specifications
Absolute Maximum Ratings
Input voltage
-0.5V to +50VDC Continous, 80V, 100 msec
Internally limited ( 6.5W typical )
300°C for 10 seconds
Power output
Soldering temperature
Operating case temperature
Storage case temperature
-55°C to +125°C
-65°C to +135°C
Conditions
ASA2805D/XX
ASA2812D/XX
ASA2815D/XX
-55° ≤ TC ≤+125°C
Group A
Subgroups
V
IN = 28V dc ±5% CL = 0
Min
Max
Min
Max
Min
Max
unless otherwise specified
TEST
Unit
V
1
±4.95
±4.90
±5.05
±5.10
±11.88
±11.76
±12.12
±12.24
±14.85
±14.70
±15.15
±15.30
Output voltage
I
= 0
OUT
2, 3
1, 2
Output current
V
= 16, 28, and 40 V dc
1, 2, 3
200
1000
84
333
67
267
mA
IN
either output
3, 4
1, 2, 3
1, 2, 3
470
50
200
50
290
50
Output ripple voltage
V
= 16, 28 and 40 V dc
mV
PP
IN
4
mV
Line regulation
V
= 16, 28, and 40 V dc
IN
I
= 0, 50%, 100% I
MAX
OUT
4
1, 2, 3
50
15
50
50
mV
Load regulation
V
= 16, 28, and 40 V dc
IN
I
= 0, 50%, 100% I
MAX
OUT
5
20% to 80% load change
1, 2, 3
1, 2, 3
8.0
8.0
%
Cross regulation
I
= 0
12
60
12
60
12
60
OUT
Pin 5 connected to pin 7
Input current
mA
I
I
I
= 0 Pin5 open
OUT
3, 4
1, 2, 3
100
100
100
Input ripple current
= I
OUT MAX
mA
PP
4
1, 3
2
70
66
71
68
71
68
Efficiency
= I
OUT MAX
%
Isolation
Input to output or any pin to
case (except pin 8) at 500 V
dc, Tc = +25° C
1
100
200
100
100
MΩ
6, 7
No effect on dc performance,
total for both outputs
Capacitive load
4
200
4.0
200
4.0
µF
8
Power dissipation load fault
4.0
Overload
1, 2, 3
4, 5, 6
W
Short circuit
2.0
2.0
2.0
4
500
600
500
600
500
600
KHz
Switching frequency
I
I
= I
OUT MAX
-400
+400
-400
+400
-400
+400
= 50% ꢀ 100% I
Output response to step
4, 9
OUT
MAX
MAX
4, 5, 6
mV pk
transient load changes
-800
+800
100
-800
+800
100
-800
+800
100
I
I
I
= 0 ꢀ 50% I
OUT
OUT
OUT
MAX
= 50% ꢀ 100% I
= 0 ꢀ 50% I
Recovery time, step
4, 5, 6
4, 5, 6
4, 5, 6
µs
mV pk
µs
transient load changes
4, 9, 10
2000
+750
2000
2000
MAX
Output response transient
-750
- 750
+750
1200
-750
+750
1200
ꢀ
V
V
=16 40Vdc,I
= I
4, 7, 11
IN
IN
OUT MAX
step line changes
Recovery time transient step
1200
line changes
=16ꢀ 40Vdc, I
= I
OUT MAX
4, 7, 10, 11
4
4, 5, 6
4, 5, 6
4, 5, 6
600
25
600
25
600
25
mV pk
ms
Turn on overshoot
I
I
= 0 and I
= 0 and I
OUT
OUT
MAX
MAX
4, 12
Turn on delay
7
25
25
25
ms
Load fault recovery
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA28XXD Series
Notes to Specifications
1.
2.
3.
4.
5.
6.
Parameter guaranteed by line, load, and cross regulation tests.
Up to 80% of full power is available from either output provided the total output does not exceed 5W.
Bandwidth of DC to 20MHz is guaranteed by design. Tested for 20KHz to 2MHz.
Load current split equally between +VOUT and -VOUT
.
1.0W load on output under test, 1.0W to 4.0W load change on other output.
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7.
8.
9.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
Load step transition time between 2µs and 10µs.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
11. Input step transition time between 2µs and 10µs.
12. Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
Block Diagram
+Output
+Input
1
6
Output
Return
2
-Output
3
Error
Amplifier
Input
Return
Case
7
8
Inhibit
5
Controller
www.irf.com
3
ASA28XXD Series
Mechanical Outline
1.075
0.800
0.270
1
2
3
4
5
0.800
±.005
1.075
8
7
6
0.025 ± .003 Dia Pins
0.220
Pin Designation
Pin #
Designation
1
+ Output
Output Return
- Output
2
3
4
5
6
7
8
NC
Inhibit
+ Input
Input Return
Case Ground
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit
Drawing Number
5962-94649
IR Standard
Part Number
ASA2815D
5962-95648
ASA2812D
4
www.irf.com
ASA28XXD Series
Device Screening
ꢀ
Requirement
MIL-STD-883 Method No Suffix
ES
HB
CH
ꢀ
Temperature Range
Element Evaluation
Non-Destructive
Bond Pull
-20°C to +85°C -55°C to +125°C
-55°C to +125°C -55°C to +125°C
MIL-PRF-38534
2023
N/A
N/A
N/A
N/A
N/A
Class H
N/A
N/A
ꢁ
Internal Visual
Temperature Cycle
Constant Acceleration
PIND
2017
1010
Yes
Cond B
500 Gs
N/A
Yes
Cond C
3000 Gs
N/A
Yes
Cond C
3000 Gs
N/A
N/A
N/A
N/A
N/A
25°C
2001, Y1 Axis
2020
Burn-In
1015
48 hrs@hi temp 160 hrs@125°C 160 hrs@125°C
ꢂ
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
25°C
-55°C, +25°C,
+125°C
N/A
-55°C, +25°C,
+125°C
10%
PDA
N/A
Cond A
N/A
N/A
Cond A, C
N/A
Seal, Fine and Gross
Radiographic
External Visual
Cond A, C
N/A
Cond A, C
N/A
2012
ꢁ
2009
Yes
Yes
Yes
Notes:
ꢀ Best commercial practice
ꢁ Sample tests at low and high temperatures
ꢂ -55°C to +105°C for AHE, ATO, ATW
Part Numbering
ASA 28 05 D /CH
Screening Level
Model
(Please refer to Screening Table)
No Suffix, ES, HB, CH
Input Voltage
28 = 28V
Output Voltage
05 = ±5V
Output
D = Dual
12 = ±12V
15 = ±15V
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2007
www.irf.com
5
相关型号:
©2020 ICPDF网 联系我们和版权申明