Solid State Remote Power Controller E-1071-623/627
Description
The E-T-A Solid State Remote Power Controllers E-1071-623/627
are electronic control modules suitable for inductive loads such as
electromagnetic valves (solenoids), magnetic brakes etc.
They are used:
•
•
•
for safe and quick switching of loads
for monitoring the electrical condition of the loads
for compensating different cable lengths
The load connected to the relay should be operated with a higher voltage
(DC 28…60 V) than its rated voltage (DC 24 V) because the load current
is controlled electronically (pulse-controlled characteristics). This is
to ensure that in industrial plants with different cable lengths (supply
cables, load cables) an increased inrush current can be applied to
each load. During hold duty the load current is reduced to a smaller
value (approx. 60 % of the current rating), thus reducing the operating
temperature and extending the life of the loads.
E-1071-623
The double pole electronic switching output prevents inadvertent
start-up or dangerous machine movements as may arise upon a
ground fault in systems with ungrounded power supply (‘IT systems’)
(see EC Machinery Directive or EN 60204 part 1 “Safety of Machinery
- Electrical Equipment of Machines”, para 9.4.3.1).
Technical data (T
= 25 °C, U = DC 48 V)
B
ambient
Rated voltage
Operating voltage UB
DC 48 V
DC 28...60 V
(see Technical description)
adjustable between 0.1...3.1 A via switch
and potentiometer on the front side
Current rating IN
Typical applications
Current consumption I0
(US = »0«)
Residual ripple for
all voltages
Reverse polarity protection UB (terminals 1 and 2), integral
Fail Save
Insulation voltage
l
Double pole switching of inductive actuators such as electromagnetic
valves or magnetic clutches in machinery and equipment
Monitoring the electrical operability of loads
Protection and monitoring of load circuit cables
Status indication, failure indication in load circuit visually
(via LEDs or red tripped button) and via potentialfree status outputs
Double pole split up of the load circuit manually or electrically in
the event of overload or short circuit
typically 16 mA
l
max. 5 % (3 phase bridge)
l
fuse
l
2.5 KV between load circuit, control circuit
and status signal circuit
l
Load circuit
Load output
NPN transistor, minus switching,
pulse-controlled (approx. 180 Hz)
DC 24 V/adjustable between 0.1...3.1 A
up to 10 % more than pickup current
typically 60 % of the set rated current IN
approx. 4.5 A
Load rating
Features
Switch-on current IE
Holding current IH
Short circuit
l
Designed for inductive loads (DC 24 V)
Individual adjustment to various load currents
(standard: IN = 0.1...3.1 A)
Significant reduction of power loss in the load by pulse-controlled
disconnection current
Wire break monitoring
Physical isolation
l
in the ON and OFF condition (RED LED)
2-pole in the load circuit,
by manual circuit breaker release
or after short circuit disconnection
2 x ø 2 mm (current proportional voltage:
1 V = 1 A )
l
characteristics
l
Double pole switching output, short-circuit proof (short-circuit
limitation); physical disconnection from supply
Current measuring plugs
l
l
Free-wheeling circuitry
(see Technical description)
integral electronic control with quick
disconnection
Inrush current and holding current monitoring
Physical isolation:
- optocoupler in the control circuit
- physical disconnection of load circuit, manually or in the event
of a short circuit
- optocoupler for status outputs
Reverse polarity and overvoltage protection in the control, load
and status circuits
Control current indication by YELLOW LED
O.K. indication by GREEN LED
Wire break indication by RED LED (load circuit)
Fault indication by RED LED
(short circuit, over/undervoltage, setting error)
Two status outputs for PLCs for evaluation
(status indication, ON indication)
^
5
Control circuit
Control
Control voltage US
optocoupler in control input
»0« = DC 0…5 V
»1« = DC 8.5…35 V
Control current IS
typically 5...10 mA
l
Switching frequency fmax
Control signal (US = »1«)
Protection
1 Hz
YELLOW LED lights (Icontrol flowing)
reverse polarity protection (diode)
l
l
l
l
Status outputs
2 signal outputs
ON indication/function indication
- physically isolated by optocoupler
- transistor outputs, plus switching
- auxiliary voltage UA: DC 12...60 V
- max. 50 mA per output
l
l
- integral free-wheeling diode
- reverse polarity and overvoltage
protection
Quick disconnection (do not connect a free-wheeling diode to the
load as the free-wheeling current is controlled electronically)
Break time < make time
ON indication
(terminal 8)
US = »0« : output non-conductive
< 70 ms switch-off signal delay
US = »1« : output connecting plus potential
(term. 10) to term. 8 only as long
as load current flows, not with
wire break or short circuit
< 15 ms switch-off signal delay
fault: output non-conductive
no fault: output connecting plus potential
(terminal 10) to terminal 9
Function indication
(terminal 9)
1646
www.e-t-a.de
1
Solid State Remote Power Controller E-1071-623/627
Technical data (T
= 25 °C, U = DC 48 V)
Technical description
ambient
B
Rated current IN, hold current IH
General data
The current rating of the applicable load at its rated voltage should
be set between 0.1...3.1 A. The holding current of the load is internally
adjusted to 60 % of the set current rating. This holding current can
be measured by means of a voltmeter connected to the 2 mm current
Ambient temperature
Terminals
0…+60 °C (without condensation)
1071-623: screw terminals
1071-627: screw-less spring-loaded
terminals
^
measuring plugs (current-proportional voltage: 1 V = 1 A).
Connection: max. 2 x 2.5 mm2 solid
max. 2 x 1.5 mm2 flex with
sleeve
Setting the current rating
Housing
clamping plate: polycarbonate GV, blue
cover: polycarbonate, black
track-mountable to EN 50022-35
The current rating is set by means of a rotary switch (switch
setting 0 A - 1 A - 2 A) and a 270° potentiometer (setting range
between 0.1...1.1 A). The sum of the two settings should equal the
current rating of the load.
Mounting
Self-extinguishing properties to UL 94: V = 0; VDE 0304: grade 1
Degree of protection
Mounting dimensions
Mass
housing, terminals IP20 DIN 40050
45 x 74 x 128 mm
approx. 170 g
Example: 24 V load with IN = 1.5 A
Setting: switch 1 A + potentiometer 0.5 A
Technical description
1
2
3
4
5
Operating voltage UB
Steuerstrom
O.K.
The max. operating voltage of the SSRPC is approx. DC 60 V. The
min. operating voltage required for 24 V solenoids depends on the
overall ohmic resistance in the load circuit. The switch-on current is
reduced by:
Fehler
Drahtbruch
1
2
0
GERMANY
IN/A
0,8
+
E-1071-623
DC 24 V-Last
0,1-3,1 A
0,6
0,4
- the voltage drop on the load cable
0,2
1,0
1,1
- the load resistance increasing with the operating temperature of
the load.
0,1
+
I
Last
= 0,6 x IN
^
1V =1A
Minimum operating voltage UB min
6
7
8
9
10
IN
Cable length
Cable size UB min
2
1.5 mm
2.5 mm
33/35/37/40 V
32/33/35/37 V
1 A
2x50 m/2x100 m/2x200 m/2x300 m
2
2
1.5 mm
2.5 mm
35/38/44/49 V
34/35/39/42 V
2 A
3 A
2x50 m/2x100 m/2x200 m/2x300 m
2x50 m/2x100 m/2x200 m/2x300 m
2
Faulty setting of current rating
The red LED (failure indication) blinks in the event of a faulty setting.
The load is disconnected only after approx. 15 sec if the current rating
value is not corrected and the red LED will be permanently lighted.
Reset is only possible by switching on again.
The tolerance range, in which faulty setting will not be indicated, is
approx. 30 % of the holding current.
2
1.5 mm
2.5 mm
37/41/50/58 V
35/38/42/48 V
2
The load capacity is no longer ensured when the minimum operating
voltage falls below UB min = 28 V. The RED LED (fault) will indicate
and the output will be switched off. Only when an operating voltage
of 29.4 V is exceeded will the load be switched on again and normal
operation status is restored.
Ordering information
Resistance increase in the load circuit:
1.5 mm2 cable
2.5 mm2 cable
approx. 2.8 Ω/100 m distance
approx. 1.6 Ω/100 m distance
5
Type No.
E-1071
SSRPC
Terminals
Maximum operating voltage UB max
623
627
screw terminals
The load capacity is no longer ensured when the max. operating
voltage UB max = 60 V is exceeded. The RED LED (fault) will indicate
and the output will be switched off. Only when the operating voltage
falls below 57 V will the load be switched on again and normal opera-
tion status is restored.
screw-less connectors
Voltage rating of load
DC 24 V
Current rating
0.1 A...3.1 A
E-1071
-
623 - DC 24 V - 0.1 A...3.1 A ordering example
Switch-on current IE = pickup current
The output transistor connects the operating voltage to the inductive
load until actual switch-on of the solenoid (pickup current). After this
period the load current is set back to holding current IH.
I
I
N = Current rating
E = Switch-on current/
pickup current
Current
IH = Holding current
IN
IE
IH
quick disconnection
ca. 10...100 ms
ON
time t
OFF
2
www.e-t-a.de
1646
Solid State Remote Power Controller E-1071-623/627
Operating modes
Schematic diagram
mode
fault-free
wire break
load short
circuit (1)
U too low/
B
high (2)
faulty
setting
ꢃꢄꢅꢅꢆꢇꢈ ꢅꢉꢈꢊꢇꢋ
ꢌꢅꢆꢍꢆꢈꢈꢊꢇꢋ
ꢌꢎꢏꢍꢊꢃꢉꢐ
ꢊꢍꢑꢐꢉꢈꢊꢑꢇ
control input
(terminals 6 and 7)
ꢑꢒꢒ
»0«
»1«
»0«
»1«
»0«
»1«
»0«
»1«
LED YELLOW – control c.
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
0
0
1
1
0
0
1
0
0
0
1
1
0
0
1
ꢀ
1
ꢁ
1
ꢄꢆꢇ
ꢈꢉꢊꢋꢋꢋ6ꢌ ꢍ ꢎꢏꢐ
ꢂ
ꢚꢂꢥꢋ 6ꢌꢍꢎꢏꢫꢌꢋ1ꢬ
ꢄꢆꢂ
1ꢌ
ꢟ
LED GREEN - O.K.
LED RED - wire break
LED RED - fault
ꢜꢖꢂꢖꢢꢜ
ꢠꢡ
ꢓ
4
ꢣꢢꢔꢕꢖꢓꢁꢔ
ꢄ
ꢕꢁꢔꢖꢙꢁꢀ ꢂꢔꢃ
ꢚꢁꢔꢓꢖꢁꢙꢓꢔꢗ
ꢛꢀꢛꢕꢖꢙꢁꢔꢓꢕꢜ
ꢍꢑꢐꢆꢇꢑꢊꢗ
ꢀꢁꢂꢃ
ꢊ
ꢝ
ꢜꢖꢂꢖꢢꢜ
ꢠꢇ
ꢁꢤꢛꢙꢂꢖꢓꢁꢔ
status function
(terminal 9)
status operation
(terminal 8)
1
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
ꢅ
ꢅꢆꢂ
ꢚꢂꢥꢋ ꢦꢝꢍꢎꢏ
ꢄꢆꢠ
6
ꢞ
ꢕꢁꢔꢖꢙꢁꢀ
ꢓꢔꢤꢢꢖ
physical isolation
0
0
0
0
0
1
0
0
ꢁ
ꢔꢕꢖ
ꢅꢆꢠ
ꢗꢘ ꢗꢔ ꢙꢖ ꢙꢖ
ꢄ
ꢅ
Notes:
ꢑꢒꢎꢅꢓꢔꢃꢓꢕꢂꢖꢓꢁꢔ ꢕꢢꢙꢙꢛꢔꢖꢅꢤꢙꢁꢤꢁꢙꢖꢓꢁꢔꢂꢀ
ꢭꢁꢀꢖꢂꢗꢛ ꢁꢢꢖꢤꢢꢖ ꢆꢈꢮꢐ
1 Short circuit: load (+) to load (-)
2 Underoltage: device disconnects at 28 V and reconnects at 29.4 V
Overvoltage: device disconnects at 60 V and reconnects at 57 V
1 - LED status output carries to plus potential
0 - LED status output is non-conductive
Dimensions
129 OFF condition
5.08
124 ON condition
4.88
121
45
1.77
4.76
119.5
4.70
5
rail EN 50022-35x7.5
(not included in delivery)
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
1646
www.e-t-a.de
3
Solid State Remote Power Controller E-1071-623/627
Terminal selection
E-1071-623 (0.1 - 3.1 A)
E-1071-627 (0.1 - 3.1 A)
Terminal
1
2
3
4
5
Operating voltage +UB: max. DC 60 V
6
Control voltage +US: max. 35 V
Operating voltage (-)
7
Control voltage -US
Load (+)
8
Status output “operation” (max. 50 mA)
Status output “function” (max. 50 mA)
Auxiliary voltage +UA for status outputs: max. DC 60 V/100 mA)
Load (-)
9
Auxiliary voltage -UA for status outputs
10
5
4
www.e-t-a.de
1646
Solid State Remote Power Controller E-1071-623/627
Application note:
Controlling and monitoring of solenoid valves in combination with LED valve plugs
Possible configuration of E-1071-62x
Please note:
lꢀ
In the event of using a plug or suppressor element not
with screw terminals:
with screwless terminals:
E-1071-623-DC 24 V-0.1...3.1 A
E-1071-627-DC 24 V-0.1...3.1 A
recommended, the wire break monitoring function might be
limited in the not activated condition.
Often DC 24 V solenoids with a low power rating are used which are
to be controlled and monitored by the above mentioned devices.
Sometimes these solenoids are fitted with solenoid valve plugs, e.g.
made by Hirschmann, and hold a small electronic pcb
- with LED,
- a series resistor
- a protective diode connected in anti-parallel to the LED
The following components can be recommended:
l
Recommended valve plugs with LED, Hirschmann
- type GDML 2011 LED 24 YE, contains the pcb
type GDME-LED 24 YE
- type GDML 2011 LED 24 RD, contains the pcb
type GDME-LED 24 RD
status indication (LED) with a protective diode connected in
anti-parallel
ꢀꢁꢂ
ꢀꢁꢂ 1
∼
∼
ꢀꢃꢂ
ꢀꢃꢂ ꢄ
∼
∼
l
Recommended adapter with LED, Murr Elektronik
- suppressor element model B – 10 mm LED,
24 V DC/50 VA/W, part no.: 3124875
5
- suppressor element model BI – 11 mm LED,
24 V AC/DC/50 VA/W, part no.: 3124215
- suppressor element model C – 8 mm LED,
24 V AC/DC/50 VA/W, part no.: 312811
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications wit-
hout notice is reserved.Product markings may not be exactly as the ordering codes. Errors
and omissions excepted.
1646
www.e-t-a.de
5
5
6
www.e-t-a.de
1646