CPC1976Y [CLARE]

AC Power Switch; AC电源开关
CPC1976Y
型号: CPC1976Y
厂家: CLARE    CLARE
描述:

AC Power Switch
AC电源开关

光电 开关 电源开关 输出元件 PC
文件: 总5页 (文件大小:98K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CPC1976  
AC Power Switch  
Description  
Parameter  
AC Operating Voltage  
Load Current  
On-State Voltage Drop  
Blocking Voltage  
Rating  
20 - 240  
2
1.15  
600  
Units  
Vrms  
Arms  
Vrms (at IL = 2Arms  
VP  
CPC1976 is an AC Solid State Switch utilizing  
dual power SCR thyristor outputs. This device also  
includes zero-cross turn-on circuitry and is specified  
with a blocking voltage of 600VP .  
)
In addition, tightly controlled zero-cross circuitry  
ensures low noise switching of AC loads by  
Features  
Load Current up to 2Arms  
600VP Blocking Voltage  
5mA Sensitivity  
Zero-Crossing Detection  
DC Control, AC Output  
Optically Isolated  
TTL and CMOS Compatible  
Low EMI and RFI Generation  
High Noise Immunity  
minimizing the generation of transients. The optically  
coupled input and output circuits provide 3750Vrms of  
isolation and noise immunity between the control and  
load circuits. As a result, the CPC1976 is well suited  
for industrial environments where electromagnetic  
interference would disrupt the operation of plant facility  
communication and control systems.  
Approvals  
UL 508 Recognized Component: File #: E69938  
CSA Certified Component: Certificate #: 1172007  
Machine Insertable, Wave Solderable  
Ordering Information  
Applications  
Programmable Control  
Process Control  
Power Control Panels  
Remote Switching  
Gas Pump Electronics  
Contactors  
Part #  
CPC1976Y  
Description  
4-Pin SIP (25/Tube)  
Pin Configuration  
Large Relays  
Solenoids  
Motors  
Heaters  
ZC  
1
2
3
4
– LED + LED  
AC Load AC Load  
RoHS  
2002/95/EC  
Pb  
e3  
DS-CPC1976-R02  
1
www.clare.com  
CPC1976  
Absolute Maximum Ratings (@ 25˚ C)  
Absolute Maximum Ratings are stress ratings. Stresses in  
excess of these ratings can cause permanent damage to  
the device. Functional operation of the device at conditions  
beyond those indicated in the operational sections of this  
data sheet is not implied.  
Parameter  
Ratings  
600  
Units  
VP  
Blocking Voltage (VDRM  
Reverse Input Voltage  
Input Control Current  
Peak (10ms)  
)
5
50  
V
mA  
A
1
Input Power Dissipation 1  
Total Power Dissipation 2  
Isolation voltage Input to Output  
Operational Temperature  
150  
mW  
mW  
Vrms  
°C  
2400  
3750  
-40 to +85  
-40 to +125  
Storage Temperature  
Derate Linearly 1.33 mW / ºC  
Derate Linearly 20 mW / ºC  
°C  
1
2
Electrical Characteristcs  
Parameters  
Conditions  
Symbol  
Min Typ Max  
Units  
Output Characteristics @ 25°C  
Load Current, Continuous  
Maximum Surge Current  
Off State Leakage Current  
On-State Voltage Drop 1  
Critical Rate of Rise  
VL=120-240Vrms  
t < 16ms  
VDRM  
IL  
IPK  
ILEAK  
-
0.005  
-
2
20  
1
Arms  
A
-
-
-
-
-
mA  
Vrms  
V/μs  
IL=2Arms  
-
0.86  
1.15  
-
dv/dt  
1000 1200  
Switching Speeds  
Turn-on  
tON  
tOFF  
-
-
-
-
0.5  
0.5  
10  
2
cycles  
cycles  
V
IF = 5 mA  
Turn-off  
-
Zero-Cross Turn-On Voltage  
1st half cycle  
-
2
-
Subsequent half cycle  
-
-
V
Holding Current  
-
-
-
IH  
IL  
-
0.82  
0.84  
-
5
mA  
mA  
Hz  
Latching Current  
Operating Frequency 2  
-
6
20  
500  
Load Power Factor for  
Guaranteed Turn-On 3  
60Hz  
PF  
0.25  
-
-
-
Input Characteristics @ 25°C  
Input Control Current 4  
60Hz  
-
IF  
-
-
-
-
5
-
mA  
V
Input Drop-out Voltage  
0.8  
0.9  
-
Input Voltage Drop  
IF=5mA  
VR=5V  
VF  
IR  
1.2  
-
1.4  
10  
V
Reverse Input Current  
μA  
Common Characteristics @ 25°C  
Input to Output Capacitance  
-
CI/O  
-
-
3
pF  
1 Tested at a peak value equivalent.  
2 Zero Cross 1st half cycle @ <100Hz.  
3 Snubber circuits may be required at low power factors.  
4 For high-noise environments, or for high-frequency operation, use IF > 10mA.  
R02  
2
www.clare.com  
CPC1976  
PERFORMANCE DATA*  
Typical On-State Voltage Drop  
Distribution  
(N=50,TA=25ºC, IL=2ADC, IF=5mA)  
Typical LED Forward Voltage Drop  
Distribution  
LED Current to Operate Distribution  
(N=50,TA=25ºC, VL=120VAC/60Hz)  
(N=50,TA=25ºC, IF=5mA)  
25  
25  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
20  
15  
10  
5
0
0
0
1.007 1.009 1.011 1.013 1.015 1.017 1.019  
1.6  
2.0  
2.4  
2.8  
3.2  
3.6  
4.0  
1.25  
1.26  
1.27  
1.28  
1.29  
1.30  
On-State Voltage Drop (VP)  
LED Forward Voltage (V)  
LED Current (mA)  
Leakage Current  
(VL=600VP)  
Typical Blocking Voltage Distribution  
(N=50,TA=25ºC)  
Blocking Voltage vs.Temperature  
960  
20  
15  
10  
5
0.72  
0.70  
0.68  
0.66  
0.64  
0.62  
0.60  
920  
880  
840  
800  
760  
0
780 810 840 870 900 930 960  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (ºC)  
Blocking Voltage (VP)  
Temperature (ºC)  
LED Current to Operate  
(VL=5V / 60Hz)  
Load Voltage vs.Temperature  
(IF=5mA)  
Holding Current  
2.4  
2.3  
2.2  
2.1  
2.0  
1.9  
1.8  
166.0  
165.5  
165.0  
164.5  
164.0  
163.5  
163.0  
162.5  
162.0  
1.05  
1.00  
0.95  
0.90  
0.85  
0.80  
0.75  
IL=2AP  
IL=1.5AP  
IL=1AP  
IL=0.5AP  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (ºC)  
Temperature (ºC)  
Temperature (ºC)  
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R02  
www.clare.com  
3
CPC1976  
PERFORMANCE DATA*  
LED Current to Operate  
vs. Load Frequency  
(TA=25ºC, VL=137Vrms, ZL=150mH)  
Load Current vs. Load Voltage  
(TA=25ºC, IF=5mA)  
LED Forward Voltage vs.Temperature  
6.0  
5.5  
5.0  
4.5  
4.0  
3.5  
3.0  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
3
2
1
0
IF=50mA  
IF=20mA  
IF=10mA  
IF=5mA  
-1  
-2  
-3  
2.5  
2.0  
0
100  
200  
300  
400  
500  
-1.5  
-1.0  
-0.5  
0.0  
0.5  
1.0  
1.5  
-40  
-20  
0
20  
40  
60  
80  
100  
Load Frequency (Hz)  
Temperature (ºC)  
Load Voltage (VP)  
Maximum Non-Repetitive Surge Current  
(Values Apply to TJ=50ºC Before Surge)  
25  
Typical dv/dt vs.Temperature  
dv/dt Method  
1200  
1000  
Vo  
20  
15  
10  
5
Vo = 300V  
dv 0.63 x 300V 189  
dt RC RC  
800  
600  
63%  
In accordance with  
EIA/NARM Standards  
RS-443 for Solid State Relays  
400  
200  
10%  
0
0
25  
50  
85  
1
10 16  
Time (ms)  
100  
1000  
RC  
Temperature (ºC)  
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R02  
4
www.clare.com  
MANUFACTURING INFORMATION  
Soldering  
Washing  
For proper assembly, the component must be  
processed in accordance with the current revision  
of IPC/JEDEC standard J-STD-020. Failure to  
follow the recommended guidelines may cause  
permanent damage to the device resulting in impaired  
performance and/or a reduced lifetime expectancy.  
Clare does not recommend ultrasonic cleaning or the  
use of chlorinated solvents.  
RoHS  
2002/95/EC  
Pb  
e3  
MECHANICAL DIMENSIONS  
7º TYP  
4 PLCS  
21.082 0.381  
(0.830 0.015)  
3.302 0.051  
(0.130 0.002)  
10.160 0.127  
(0.400 0.005)  
1.016 0.127  
(0.040 0.005)  
4.572 0.127  
(0.180 0.005)  
1.778  
(0.070)  
Pin 1  
Pin 4  
0.381 0.013  
(0.015 0.0005)  
10.160 0.127  
(0.400 0.005)  
0.762 0.076  
(0.030 0.003)  
1.651 0.102  
(0.065 0.004)  
2.540 0.127  
(0.100 0.005)  
5.080 0.127  
(0.200 0.005)  
Recommended Hole Pattern  
4 x 1.326 (0.052) DIA.  
2.540 (0.100)  
12.700 (0.500)  
17.780 (0.700)  
Dimensions  
mm  
(inches)  
Note: Recommended hole size is based on the maximum  
cross-section diagonal measure of the pin plus 0.4mm (0.016).  
For additional information please visit our website at: www.clare.com  
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications  
and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of  
Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability,  
fitness for a particular purpose, or infringement of any intellectual property right.  
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other  
applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental  
damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice.  
Specification: DS-CPC1976-R02  
©Copyright 2009, Clare, Inc.  
All rights reserved. Printed in USA.  
3/9/09  

相关型号:

CPC1976YX6

Trigger Output SSR
IXYS

CPC1977

i4-PAC⑩ Power Relay
CLARE

CPC1977J

i4-PAC⑩ Power Relay
CLARE

CPC1977_11

i4-PAC™ Power
CLARE

CPC1978

i4-PAC⑩ Power Relay
CLARE

CPC1978J

i4-PAC⑩ Power Relay
CLARE

CPC1978_11

i4-PAC? Power Relay
CLARE

CPC1979

ISOPLUS⑩-264 Power Relay
CLARE

CPC1979J

ISOPLUS⑩-264 Power Relay
CLARE

CPC1979_11

ISOPLUS?-264 Power Relay
CLARE

CPC1981

OptoMOS? Power SIP Relay
CLARE

CPC1981Y

Power SIP Relay
CLARE