CPC1976YX6 [IXYS]

Trigger Output SSR;
CPC1976YX6
型号: CPC1976YX6
厂家: IXYS CORPORATION    IXYS CORPORATION
描述:

Trigger Output SSR

输出元件 光电
文件: 总6页 (文件大小:122K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CPC1976YX6  
Rapid Turn-On  
AC Power Switch  
INTEGRATED  
CIRCUITS  
DIVISION  
Description  
Parameter  
AC Operating Voltage  
Load Current  
On-State Voltage Drop  
Blocking Voltage  
Rating  
20 - 240  
2
1.25  
600  
Units  
Vrms  
Arms  
CPC1976YX6 is an AC Solid State Switch utilizing  
dual power SCR outputs. This device features Rapid  
Turn-On (non-zero-cross) control of the output SCRs,  
which makes it ideal for precisely switching AC loads  
independent of the load voltage phase.  
VP (at IL = 2AP)  
VP  
The optically coupled input and output circuits  
provide 3750Vrms of isolation and noise immunity  
between the control and load circuits. As a result, the  
CPC1976YX6 is well suited for industrial environments  
where electromagnetic interference would disrupt the  
operation of plant facility communication and control  
systems.  
Features  
Load Current up to 2Arms  
600VP Blocking Voltage  
High Surge Current: 20A  
Rapid Turn-On (Non-Zero-Cross Turn-On)  
5mA Sensitivity  
Creepage Distance: 0.125" on Output Pins  
DC Control, AC Output  
Optically Isolated  
Approvals  
UL Recognized Component: File E69938  
CSA Certified Component: Certificate 1172007  
TTL and CMOS Compatible  
Low EMI and RFI Generation  
High Noise Immunity  
Machine Insertable, Wave Solderable  
Ordering Information  
Part #  
Description  
Applications  
HVAC Control (Heating, Ventilation, Air Conditioning)  
Lighting  
CPC1976YX6 4-Pin (8-Pin Body) SIP (25/Tube)  
Programmable Control  
Process Control  
Power Control Panels  
Remote Switching  
Gas Pump Electronics  
Contactors  
Pin Configuration  
R
Large Relays  
Solenoids  
Motors  
1
2
3
4
– LED + LED  
AC Load AC Load  
Heaters  
Rapid Turn-On (Non-Zero-Cross) Waveforms  
Control  
AC Load  
Voltage  
Load  
Current  
Voltage  
Across  
Relay  
DS-CPC1976YX6-R02  
1
www.ixysic.com  
CPC1976YX6  
INTEGRATED  
CIRCUITS  
DIVISION  
Absolute Maximum Ratings @ 25ºC  
Absolute Maximum Ratings are stress ratings. Stresses in  
Parameter  
Ratings  
600  
Units  
VP  
excess of these ratings can cause permanent damage to the  
device. Functional operation of the device at conditions beyond  
those indicated in the operational sections of this data sheet is  
not implied.  
Blocking Voltage (VDRM  
Reverse Input Voltage  
Input Control Current  
Peak (10ms)  
)
5
V
50  
1
mA  
A
di/dt Critical Rate of Rise  
of On-State Current  
40  
A/s  
Input Power Dissipation 1  
Total Power Dissipation 2  
150  
2400  
mW  
mW  
kV  
A2s  
Vrms  
°C  
ESD, Human Body Model  
i2t for Fusing (1/2 Sine Wave, 60Hz)  
Isolation Voltage, Input to Output  
Operational Temperature  
4
3.5  
3750  
-40 to +85  
-40 to +125  
Storage Temperature  
Derate linearly 1.33 mW / ºC  
Derate linearly 20 mW / ºC  
°C  
1
2
Electrical Characteristics @ 25ºC  
Parameters  
Conditions  
Symbol  
Min Typ Max  
Units  
Output Characteristics  
Load Current, Continuous  
Maximum Surge Current  
Off State Leakage Current  
On-State Voltage Drop  
Critical Rate of Rise  
VL=20-240Vrms  
t < 16ms  
VDRM  
IL  
IPK  
ILEAK  
-
0.070  
-
-
2
20  
10  
1.25  
-
Arms  
A
-
-
-
-
A  
VP  
IL=2AP  
-
1.1  
dv/dt  
1000 1200  
V/s  
Switching Speeds  
Turn-on  
IF = 5 mA, Resistive  
VL=20V, 60Hz  
ton  
toff  
IH  
-
-
20  
-
500  
0.5  
75  
s  
cycle  
mA  
mA  
Hz  
Turn-off  
Holding Current  
-
-
-
-
-
Latching Current  
IL  
-
-
100  
500  
Operating Frequency  
Input Characteristics  
Input Control Current to Activate 1  
Input Drop-out Voltage  
Input Voltage Drop  
20  
-
60Hz  
-
IF  
-
-
-
-
5
-
mA  
V
0.8  
0.9  
-
IF=5mA  
VR=5V  
VF  
IR  
1.2  
-
1.4  
10  
V
Reverse Input Current  
Common Characteristics  
Input to Output Capacitance  
A  
-
CI/O  
-
-
3
pF  
1 For high-noise environments, or for high-frequency operation, use IF > 10mA.  
R02  
2
www.ixysic.com  
CPC1976YX6  
INTEGRATED  
CIRCUITS  
DIVISION  
PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)*  
LED Forward Voltage Distribution  
(N=50, IF=5mA)  
LED Current to Operate Distribution  
(N=50, VL=120VAC/60Hz)  
On-State Voltage Drop Distribution  
(N=50, IF=5mA, IL=2AP)  
25  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
0
0
0
1.04  
1.06  
1.08  
1.10  
1.12  
1.14  
1.5  
1.7  
1.9  
2.1  
2.3  
2.5  
2.7  
1.25  
1.26  
1.27  
1.28  
1.29  
1.30  
On-State Voltage Drop (V)  
LED Current (mA)  
LED Forward Voltage (V)  
Typical Blocking Voltage Distribution  
(N=50)  
25  
20  
15  
10  
5
0
747 750 753 756 759 762 765 768  
Blocking Voltage (VP)  
LED Current to Operate  
vs.Temperature (Resistive Load)  
(IL=1A, f=60Hz)  
Holding Current vs.Temperature  
LED Forward Voltage  
vs.Temperature  
(RL=1.9:)  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
2.6  
2.5  
2.4  
2.3  
2.2  
2.1  
2.0  
1.9  
1.8  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
IF=50mA  
IF=20mA  
IF=10mA  
IF=5mA  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Temperature (ºC)  
Temperature (ºC)  
Temperature (ºC)  
Typical Turn-On Time  
vs. LED Forward Current  
Turn-On Time vs.Temperature  
20  
15  
10  
5
70  
60  
50  
40  
30  
20  
10  
IF=5mA  
IF=10mA  
0
0
0
-40  
-20  
0
20  
40  
60  
80  
100  
10  
20  
30  
40  
50  
Temperature (ºC)  
LED Forward Current (mA)  
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R02  
www.ixysic.com  
3
CPC1976YX6  
INTEGRATED  
CIRCUITS  
DIVISION  
PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)*  
Maximum Load Current  
Load Voltage vs.Temperature  
(IF=5mA)  
vs.Temperature  
(IF=5mA)  
Load Current vs. Load Voltage  
(IF=5mA)  
1.2  
1.1  
1.0  
0.9  
0.8  
0.7  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
3
2
TA=+85ºC  
TA=+25ºC  
TA= -40ºC  
1
0
IL=2.5A  
IL=2A  
IL=1A  
-1  
-2  
-3  
IL=0.5A  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 2.0  
Temperature (ºC)  
Temperature (ºC)  
Load Voltage (V)  
Maximum Non-Repetitive Surge Current  
(Values Apply to TJ=50ºC Before Surge)  
Blocking Voltage vs.Temperature  
Leakage Current vs.Temperature  
25  
950  
900  
850  
800  
750  
700  
10000  
1000  
100  
10  
VL=600V  
VL=400V  
VL=200V  
20  
15  
10  
5
1
0
0.1  
0.1  
1
10  
100  
1000  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
Time (ms)  
Temperature (ºC)  
Temperature (ºC)  
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application  
department.  
R02  
4
www.ixysic.com  
CPC1976YX6  
INTEGRATED  
CIRCUITS  
DIVISION  
Manufacturing Information  
Moisture Sensitivity  
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated  
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to  
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product  
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper  
operation of our devices when handled according to the limitations and information in that standard as well as to any  
limitations set forth in the information or standards referenced below.  
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced  
product performance, reduction of operable life, and/or reduction of overall reliability.  
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according  
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.  
Device  
Moisture Sensitivity Level (MSL) Rating  
CPC1976YX6  
MSL 1  
ESD Sensitivity  
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.  
Reflow Profile  
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020  
must be observed.  
Device  
MaximumTemperature xTime  
CPC1976YX6  
245ºC for 30 seconds  
Board Wash  
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to  
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as  
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary  
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.  
Cleaning methods that employ ultrasonic energy should not be used.  
R02  
www.ixysic.com  
5
CPC1976YX6  
INTEGRATED  
CIRCUITS  
DIVISION  
MECHANICAL DIMENSIONS  
CPC1976YX6  
21.082 0.381  
(0.830 0.015)  
PCB Hole Pattern  
3.302 0.051  
(0.130 0.002)  
1.150 DIA. x4  
(0.045 DIA. x4)  
1.75  
(0.069)  
10.160 0.127  
(0.400 0.005)  
7º TYP  
4 Places  
5.080  
(0.200)  
Pin 1  
1.016 0.127  
(0.040 0.005)  
10.160  
(0.400)  
Pin 1  
1.778  
(0.070)  
4.572 0.127  
(0.180 0.005)  
2.540  
(0.100)  
0.381 0.013  
(0.015 0.0005)  
0.762 0.076  
(0.030 0.003)  
10.160 0.127  
(0.400 0.005)  
1.651 0.102  
(0.065 0.004)  
1.778  
(0.070)  
5.080 0.127  
(0.200 0.005)  
2.540 0.127  
(0.100 0.005)  
7º TYP  
4 Places  
Dimensions  
mm  
(inches)  
For additional information please visit our website at: www.ixysic.com  
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make  
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated  
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its  
products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.  
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other  
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe  
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.  
Specification: DS-CPC1976YX6-R02  
©Copyright 2014, IXYS Integrated Circuits Division  
All rights reserved. Printed in USA.  
6/11/2014  
6

相关型号:

CPC1977

i4-PAC⑩ Power Relay
CLARE

CPC1977J

i4-PAC⑩ Power Relay
CLARE

CPC1977_11

i4-PAC™ Power
CLARE

CPC1978

i4-PAC⑩ Power Relay
CLARE

CPC1978J

i4-PAC⑩ Power Relay
CLARE

CPC1978_11

i4-PAC? Power Relay
CLARE

CPC1979

ISOPLUS⑩-264 Power Relay
CLARE

CPC1979J

ISOPLUS⑩-264 Power Relay
CLARE

CPC1979_11

ISOPLUS?-264 Power Relay
CLARE

CPC1981

OptoMOS? Power SIP Relay
CLARE

CPC1981Y

Power SIP Relay
CLARE

CPC1981_11

OptoMOS? Power SIP Relay
CLARE