F70 [XPPOWER]

ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS;
F70
型号: F70
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS

文件: 总6页 (文件大小:622K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
F SERIES  
ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS  
200V to 8kV at 10W  
PRODUCT SELECTION TABLE  
OUTPUT  
OUTPUT  
MODEL  
VOLTAGE*2  
CURRENT*1  
F02  
F03  
F04  
F05  
F06  
F08  
F10  
F12  
F15  
F20  
F30  
F40  
F50  
F60  
F70  
F80  
0 to 200V  
0 to 300V  
0 to 400V  
0 to 500V  
0 to 600V  
0 to 800V  
0 to 1kV  
0 to 1.2kV  
0 to 1.5kV  
0 to 2kV  
0 to 3kV  
0 to 4kV  
0 to 5kV  
0 to 6kV  
0 to 7kV  
0 to 8kV  
50 mA  
33.3 mA  
25 mA  
PRODUCTDESCRIPTION  
20 mA  
16 mA  
The F Series is a broad line of robust, field-proven DC to HV  
DC converters which deliver 10 Watts continuous output power.  
Outputs range from 200V to 8kV. The input and output are  
galvanically isolated so a unit can be used to deliver a positive  
or negative high-voltage. The output voltage is proportional to  
input voltage with a low 0.7V typical turn-on voltage. The F Series  
employs EMCO’s quasi-sinewave oscillator, a fully enclosed  
transformer, input and output filtering, and a 5-sided metal  
enclosure. As a result, these modules exhibit very low EMI/RFI,  
noise and ripple. A dual output option with center-tap pin which,  
when grounded provides both positive and negative outputs from  
one compact module.  
12.5 mA  
10 mA  
8.3 mA  
6.6 mA  
5 mA  
3.3 mA  
2.5 mA  
2 mA  
Output Voltage vs. Input Voltage  
1.66 mA  
1.5 mA  
1.25 mA  
140  
120  
100  
80  
t
Full-load  
No-load  
60  
40  
FEATURES  
20  
• Proportional Input/Output  
0
• Compact, PCB Mount Package  
• Metal Case / Shielded Transformer  
• Short Circuit Protection  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Input Voltage (%)  
• Low Ripple, Low EMI / RFI  
• Proven Reliability  
• Input/Output Isolation  
• Low Leakage Current  
APPLICATIONS  
• Low Input/Output Coupling Capacitance  
• No External Components Required  
• No Minimum Load Required  
• MTBF: >810K hrs per Bellcore TR-332  
• RoHS Compliant  
Electrophoresis  
Mass Spectrometry  
Electrostatic Chuck  
Igniter / Spark Module  
Sustaining Ion Pumps  
Capacitor Charging  
Piezo Devices  
Field Generation  
Grid Bias  
OPTIONS  
• Dual output (Center Tap) Models Available (CT Suffix)  
Mounting Holes (F02 thru F60 only)(H Suffix)  
WWW.XPPOWER.COM  
4722AV03  
PAGE 1  
F SERIES  
2
ELECTRICAL SPECIFICATIONS*  
DUAL OUTPUT  
(CENTER TAP)  
MODEL  
INPUT  
VOLTAGE  
OUTPUT  
CURRENT  
REVERSIBLE  
MODEL  
OUTPUT  
VOLTAGE  
OUTPUT  
VOLTAGE  
MODELS  
RIPPLE*4  
F02/F02CT  
F03/F03CT  
F04/F04CT  
F05/F05CT  
F06/F06CT  
F08/F08CT  
F10/F10CT  
F12/F12CT  
F15/F15CT  
F20/F20CT  
F30/F30CT  
F40/F40CT  
F50/F50CT  
F60/F60CT  
F70/F70CT  
F80/F80CT  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 12V  
0 to 15V  
0 to 15V  
0 to 15V  
0 to 15V  
0 to 15V  
0 to 15V  
50mA  
33.3mA  
25mA  
20mA  
16mA  
12.5mA  
10mA  
8.3mA  
6.6mA  
5mA  
<1.0%  
<1.0%  
<1.0%  
<0.1%  
<0.1%  
<0.1%  
<0.1%  
<0.1%  
<0.1%  
<1.0%  
<1.0%  
<1.0%  
<1.0%  
<1.0%  
<2.5%  
<2.5%  
F02  
F03  
F04  
F05  
F06  
F08  
F10  
F12  
F15  
F20  
F30  
F40  
F50  
F60  
F70  
F80  
0 to 200V  
0 to 300V  
0 to 400V  
0 to 500V  
0 to 600V  
0 to 800V  
0 to 1kV  
0 to 1.2kV  
0 to 1.5kV  
0 to 2kV  
0 to 3kV  
0 to 4kV  
0 to 5kV  
0 to 6kV  
0 to 7kV  
0 to 8kV  
F02CT  
F03CT  
F04CT  
F05CT  
F06CT  
F08CT  
F10CT  
F12CT  
F15CT  
F20CT  
F30CT  
F40CT  
F50CT  
F60CT  
F70CT  
F80CT  
0 to +/- 100V  
0 to +/- 150V  
0 to +/- 200V  
0 to +/- 250V  
0 to +/- 300V  
0 to +/- 400V  
0 to +/- 500V  
0 to +/- 600V  
0 to +/- 750V  
0 to +/- 1kV  
0 to +/- 1.5kV  
0 to +/- 2kV  
0 to +/- 2.5kV  
0 to +/- 3kV  
0 to +/- 3.5kV  
0 to +/- 4kV  
3.3mA  
2.5mA  
2mA  
1.66mA  
1.5mA  
1.25mA  
WWW.XPPOWER.COM  
4722AV03  
PAGE 2  
F SERIES  
F-SERIES ELECTRICAL SPECIFICATIONS*3  
PARAMETER  
VALUE  
0 TO 12V (F02 TO F20)  
0 TO 15V (F30 TO F80)  
<0.7V  
INPUT VOLTAGE  
TURN-ON VOLTAGE  
INPUT CURRENT  
<500MA, NO LOAD  
<1.5A, FULL LOAD  
< +/-3.5kV BIAS (F02 TO F60)  
< +/-500V BIAS (F70 TO F80)  
~240uF  
ISOLATION  
INPUT CAPACITANCE  
RESPONSE TIME  
260 ms (typical)  
OUTPUT VOLTAGE TOLERANCE  
FREQUENCY  
+/-5% (Full Load, 100% output voltage)  
25 kHz TO 125 kHz  
OPERATING TEMPERATURE*5  
-10C to +70C (Case)  
STORAGE TEMPERATURE  
-25C to +90C  
BLOCK DIAGRAM  
1
3
(+) In  
(+) Output  
Rectifier &  
Multiplier  
Oscillator  
5
Center tap (for Dual output option)  
2
4
(-) In  
(-) Output  
Transformer  
HOT SPOT CASE TEMPERATURE POINT  
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)  
+
+
DIMENSIONAL TOLERANCES: .XX = 0.03 (0.76), .XXX = 0.005 ( 0.127)  
-
-
WWW.XPPOWER.COM  
4722AV03  
PAGE 3  
F SERIES  
MECHANICAL SPECIFICATIONS F02-F60  
TOP VIEW  
2.80  
0.20  
(5.1)  
(71.1)  
PCB LAYOUT  
COMPONENT SIDE  
1.70  
TOP VIEW  
1.300  
(43.2)  
(33.02)  
LOCATION OF  
MTG. HOLES (OPTIONAL)  
OPTIONAL  
0.20  
(5.1)  
2.400  
DUAL OUTPUT  
(CENTER TAP)  
Ø 0.140 (3.56) 2PL  
MTG HOLE (OPTIONAL)  
(60.96)  
#4/M3 CLEARANCE  
2 HOLES.  
1.050 (26.67)  
0.800 (20.32)  
4
2
1
0.900 (22.86)  
0.400 (10.16)  
5
*
0.20  
(5.1)  
0.85 (21.6)  
0
0.100 (2.54)  
0.250 (6.35)  
3
PC PINS  
0.031  
(0.79)  
RECOMMENDED  
HOLE & PAD O.D. SIZE:  
Ø 0.052 (1.32) & Ø 0.082 (2.08)  
*5 PLACES  
0.500  
(12.70)  
3
5*  
4
1
2
1.000  
0.800  
(25.40)  
(20.32)  
0.35  
(8.9)  
0.45  
(11.4)  
(0.85)  
1.200  
(30.48)  
(21.6)  
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.  
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)  
BOTTOM VIEW  
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)  
-
-
PARAMETER  
WEIGHT  
VALUE  
<5 OZ (142 GRAMS)  
PIN #  
FUNCTION  
(+) Input  
1
2
3
4
5
VOLUME  
4.0 cu. In. (66.3 cc)  
(-) Input  
DIMENSIONS  
CASE MATERIAL  
2.80L (71.1L) x 1.70W (43.2W) x 0.85H (21.6H)  
Black Anodized Aluminum  
(+) Output  
(-) Output  
Dual Output/Center Tap (optional)  
WWW.XPPOWER.COM  
4722AV03  
PAGE 4  
F SERIES  
MECHANICAL SPECIFICATIONS F70-F80  
TOP VIEW  
2.80  
RECOMMENDED  
PCB LAYOUT  
(71.1)  
.25  
(6.4)  
TOP VIEW  
0.85  
OPTIONAL  
(21.6)  
DUAL OUTPUT  
(CENTER TAP)  
1.70  
1.200  
(30.48)  
4
2
1
(43.2)  
0.800  
5
*
(20.32)  
0.400 (10.16)  
3
0.45 (11.4)  
1.30  
Ø .140 (3.56)  
(33.0)  
MTG HOLES, 2X  
1.400  
(35.56)  
#4/M3 CLEARANCE  
RECOMMENDED  
HOLE & PAD SIZE:  
Ø 0.052 (1.32) & Ø 0.090 (2.29)  
0.95  
3 PLACES  
*
(24.1)  
Ø0.250 (6.35) CLEARANCE  
FOR 0.215" (5.46mm) O.D.  
OUTPUT LEADS  
2 PLACES  
MIN 0.25  
(6.4)  
OUTPUT LEADS:  
PC PINS  
Ø0.040  
(1.02)  
#22 AWG, 30KV  
6.00" (152.4mm)  
SILICONE  
MINIMUM LENGTH.  
0.215" (5.46mm) O.D.  
2 PLACES.  
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.  
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)  
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)  
-
-
PARAMETER  
WEIGHT  
VALUE  
<5 OZ (142 GRAMS)  
4.5 cu. In. (74.1cc)  
PIN #  
FUNCTION  
(+) Input  
1
2
3
4
5
VOLUME  
(-) Input  
DIMENSIONS  
CASE MATERIAL  
2.80L (71.12L) x 1.70W (43.18W) x 0.95H (24.13H)  
Black Anodized Aluminum  
(+) Output  
(-) Output  
Dual Output/Center Tap (optional)  
WWW.XPPOWER.COM  
4722AV03  
PAGE 5  
F SERIES  
OPTION CODE TABLE  
OPTION  
ORDER CODE  
MODELS  
Positive / Negative reversible  
Dual Output (center tap) option  
ROHS  
Blank  
CT  
R
ALL  
POLARITY  
OPTIONS  
ALL  
ALL  
Mounting Holes  
H
UP TO 6KV  
HOW TO ORDER  
PART NUMBER SELECTOR:  
Model Number:  
F30CTH  
Model  
Output Voltage (See table)  
Mounting Holes (optional)  
Center Tap (for dual output option)  
EXAMPLE: F30CTH (F-Model, 30-Output Voltage, CT-Center Tap, H-Holes)  
* Notes:  
1. At maximum rated output voltage.  
2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded.  
3. Specifications after 1 hour warm up, full load, at 25C unless otherwise indicated.  
4. Ripple specification for dual output units applies to the voltage between the positive and negative output terminals.  
5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output  
XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product  
changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details.  
WWW.XPPOWER.COM  
4722AV03  
PAGE 6  

相关型号:

F70/F70CT

ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
XPPOWER

F7003

Inside DC Block, 0.009MHz Min, 18600MHz Max, 0.9dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH

F7006

Inside DC Block, 0.009MHz Min, 26500MHz Max, 0.8dB Insertion Loss-Max,
APITECH

F7006-1

Inside DC Block, 0.009MHz Min, 20000MHz Max, 0.8dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
APITECH

F7007N

N-channel, Single 30V/7A
FUJI

F7071

SAW Bandpass Filter F7071
ITF

F70M12A

Monolithic Crystal Filters
ECM

F70M12B

Monolithic Crystal Filters
ECM

F70M15A

Monolithic Crystal Filters
ECM

F70M15B

Monolithic Crystal Filters
ECM

F70M20A

Monolithic Crystal Filters
ECM

F70M20B

Monolithic Crystal Filters
ECM