F SERIES
ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
200V to 8kV at 10W
PRODUCT SELECTION TABLE
OUTPUT
OUTPUT
MODEL
VOLTAGE*2
CURRENT*1
F02
F03
F04
F05
F06
F08
F10
F12
F15
F20
F30
F40
F50
F60
F70
F80
0 to 200V
0 to 300V
0 to 400V
0 to 500V
0 to 600V
0 to 800V
0 to 1kV
0 to 1.2kV
0 to 1.5kV
0 to 2kV
0 to 3kV
0 to 4kV
0 to 5kV
0 to 6kV
0 to 7kV
0 to 8kV
50 mA
33.3 mA
25 mA
PRODUCTDESCRIPTION
20 mA
16 mA
The F Series is a broad line of robust, field-proven DC to HV
DC converters which deliver 10 Watts continuous output power.
Outputs range from 200V to 8kV. The input and output are
galvanically isolated so a unit can be used to deliver a positive
or negative high-voltage. The output voltage is proportional to
input voltage with a low 0.7V typical turn-on voltage. The F Series
employs EMCO’s quasi-sinewave oscillator, a fully enclosed
transformer, input and output filtering, and a 5-sided metal
enclosure. As a result, these modules exhibit very low EMI/RFI,
noise and ripple. A dual output option with center-tap pin which,
when grounded provides both positive and negative outputs from
one compact module.
12.5 mA
10 mA
8.3 mA
6.6 mA
5 mA
3.3 mA
2.5 mA
2 mA
Output Voltage vs. Input Voltage
1.66 mA
1.5 mA
1.25 mA
140
120
100
80
t
Full-load
No-load
60
40
FEATURES
20
• Proportional Input/Output
0
• Compact, PCB Mount Package
• Metal Case / Shielded Transformer
• Short Circuit Protection
0
10
20
30
40
50
60
70
80
90
100
Input Voltage (%)
• Low Ripple, Low EMI / RFI
• Proven Reliability
• Input/Output Isolation
• Low Leakage Current
APPLICATIONS
• Low Input/Output Coupling Capacitance
• No External Components Required
• No Minimum Load Required
• MTBF: >810K hrs per Bellcore TR-332
• RoHS Compliant
•
•
•
•
•
Electrophoresis
•
•
•
•
Mass Spectrometry
Electrostatic Chuck
Igniter / Spark Module
Sustaining Ion Pumps
Capacitor Charging
Piezo Devices
Field Generation
Grid Bias
OPTIONS
• Dual output (Center Tap) Models Available (CT Suffix)
Mounting Holes (F02 thru F60 only)(H Suffix)
•
WWW.XPPOWER.COM
4722AV03
PAGE 1
F SERIES
2
ELECTRICAL SPECIFICATIONS*
DUAL OUTPUT
(CENTER TAP)
MODEL
INPUT
VOLTAGE
OUTPUT
CURRENT
REVERSIBLE
MODEL
OUTPUT
VOLTAGE
OUTPUT
VOLTAGE
MODELS
RIPPLE*4
F02/F02CT
F03/F03CT
F04/F04CT
F05/F05CT
F06/F06CT
F08/F08CT
F10/F10CT
F12/F12CT
F15/F15CT
F20/F20CT
F30/F30CT
F40/F40CT
F50/F50CT
F60/F60CT
F70/F70CT
F80/F80CT
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 12V
0 to 15V
0 to 15V
0 to 15V
0 to 15V
0 to 15V
0 to 15V
50mA
33.3mA
25mA
20mA
16mA
12.5mA
10mA
8.3mA
6.6mA
5mA
<1.0%
<1.0%
<1.0%
<0.1%
<0.1%
<0.1%
<0.1%
<0.1%
<0.1%
<1.0%
<1.0%
<1.0%
<1.0%
<1.0%
<2.5%
<2.5%
F02
F03
F04
F05
F06
F08
F10
F12
F15
F20
F30
F40
F50
F60
F70
F80
0 to 200V
0 to 300V
0 to 400V
0 to 500V
0 to 600V
0 to 800V
0 to 1kV
0 to 1.2kV
0 to 1.5kV
0 to 2kV
0 to 3kV
0 to 4kV
0 to 5kV
0 to 6kV
0 to 7kV
0 to 8kV
F02CT
F03CT
F04CT
F05CT
F06CT
F08CT
F10CT
F12CT
F15CT
F20CT
F30CT
F40CT
F50CT
F60CT
F70CT
F80CT
0 to +/- 100V
0 to +/- 150V
0 to +/- 200V
0 to +/- 250V
0 to +/- 300V
0 to +/- 400V
0 to +/- 500V
0 to +/- 600V
0 to +/- 750V
0 to +/- 1kV
0 to +/- 1.5kV
0 to +/- 2kV
0 to +/- 2.5kV
0 to +/- 3kV
0 to +/- 3.5kV
0 to +/- 4kV
3.3mA
2.5mA
2mA
1.66mA
1.5mA
1.25mA
WWW.XPPOWER.COM
4722AV03
PAGE 2
F SERIES
F-SERIES ELECTRICAL SPECIFICATIONS*3
PARAMETER
VALUE
0 TO 12V (F02 TO F20)
0 TO 15V (F30 TO F80)
<0.7V
INPUT VOLTAGE
TURN-ON VOLTAGE
INPUT CURRENT
<500MA, NO LOAD
<1.5A, FULL LOAD
< +/-3.5kV BIAS (F02 TO F60)
< +/-500V BIAS (F70 TO F80)
~240uF
ISOLATION
INPUT CAPACITANCE
RESPONSE TIME
260 ms (typical)
OUTPUT VOLTAGE TOLERANCE
FREQUENCY
+/-5% (Full Load, 100% output voltage)
25 kHz TO 125 kHz
OPERATING TEMPERATURE*5
-10C to +70C (Case)
STORAGE TEMPERATURE
-25C to +90C
BLOCK DIAGRAM
1
3
(+) In
(+) Output
Rectifier &
Multiplier
Oscillator
5
Center tap (for Dual output option)
2
4
(-) In
(-) Output
Transformer
HOT SPOT CASE TEMPERATURE POINT
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
+
+
DIMENSIONAL TOLERANCES: .XX = 0.03 (0.76), .XXX = 0.005 ( 0.127)
-
-
WWW.XPPOWER.COM
4722AV03
PAGE 3
F SERIES
MECHANICAL SPECIFICATIONS F02-F60
TOP VIEW
2.80
0.20
(5.1)
(71.1)
PCB LAYOUT
COMPONENT SIDE
1.70
TOP VIEW
1.300
(43.2)
(33.02)
LOCATION OF
MTG. HOLES (OPTIONAL)
OPTIONAL
0.20
(5.1)
2.400
DUAL OUTPUT
(CENTER TAP)
Ø 0.140 (3.56) 2PL
MTG HOLE (OPTIONAL)
(60.96)
#4/M3 CLEARANCE
2 HOLES.
1.050 (26.67)
0.800 (20.32)
4
2
1
0.900 (22.86)
0.400 (10.16)
5
*
0.20
(5.1)
0.85 (21.6)
0
0.100 (2.54)
0.250 (6.35)
3
PC PINS
0.031
(0.79)
RECOMMENDED
HOLE & PAD O.D. SIZE:
Ø 0.052 (1.32) & Ø 0.082 (2.08)
*5 PLACES
0.500
(12.70)
3
5*
4
1
2
1.000
0.800
(25.40)
(20.32)
0.35
(8.9)
0.45
(11.4)
(0.85)
1.200
(30.48)
(21.6)
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
BOTTOM VIEW
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)
-
-
PARAMETER
WEIGHT
VALUE
<5 OZ (142 GRAMS)
PIN #
FUNCTION
(+) Input
1
2
3
4
5
VOLUME
4.0 cu. In. (66.3 cc)
(-) Input
DIMENSIONS
CASE MATERIAL
2.80L (71.1L) x 1.70W (43.2W) x 0.85H (21.6H)
Black Anodized Aluminum
(+) Output
(-) Output
Dual Output/Center Tap (optional)
WWW.XPPOWER.COM
4722AV03
PAGE 4
F SERIES
MECHANICAL SPECIFICATIONS F70-F80
TOP VIEW
2.80
RECOMMENDED
PCB LAYOUT
(71.1)
.25
(6.4)
TOP VIEW
0.85
OPTIONAL
(21.6)
DUAL OUTPUT
(CENTER TAP)
1.70
1.200
(30.48)
4
2
1
(43.2)
0.800
5
*
(20.32)
0.400 (10.16)
3
0.45 (11.4)
1.30
Ø .140 (3.56)
(33.0)
MTG HOLES, 2X
1.400
(35.56)
#4/M3 CLEARANCE
RECOMMENDED
HOLE & PAD SIZE:
Ø 0.052 (1.32) & Ø 0.090 (2.29)
0.95
3 PLACES
*
(24.1)
Ø0.250 (6.35) CLEARANCE
FOR 0.215" (5.46mm) O.D.
OUTPUT LEADS
2 PLACES
MIN 0.25
(6.4)
OUTPUT LEADS:
PC PINS
Ø0.040
(1.02)
#22 AWG, 30KV
6.00" (152.4mm)
SILICONE
MINIMUM LENGTH.
0.215" (5.46mm) O.D.
2 PLACES.
NOTE: CASE IS INTERNALLY CONNECTED TO (-) INPUT.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)
-
-
PARAMETER
WEIGHT
VALUE
<5 OZ (142 GRAMS)
4.5 cu. In. (74.1cc)
PIN #
FUNCTION
(+) Input
1
2
3
4
5
VOLUME
(-) Input
DIMENSIONS
CASE MATERIAL
2.80L (71.12L) x 1.70W (43.18W) x 0.95H (24.13H)
Black Anodized Aluminum
(+) Output
(-) Output
Dual Output/Center Tap (optional)
WWW.XPPOWER.COM
4722AV03
PAGE 5
F SERIES
OPTION CODE TABLE
OPTION
ORDER CODE
MODELS
Positive / Negative reversible
Dual Output (center tap) option
ROHS
Blank
CT
R
ALL
POLARITY
OPTIONS
ALL
ALL
Mounting Holes
H
UP TO 6KV
HOW TO ORDER
PART NUMBER SELECTOR:
Model Number:
F30CTH
Model
Output Voltage (See table)
Mounting Holes (optional)
Center Tap (for dual output option)
EXAMPLE: F30CTH (F-Model, 30-Output Voltage, CT-Center Tap, H-Holes)
* Notes:
1. At maximum rated output voltage.
2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded.
3. Specifications after 1 hour warm up, full load, at 25C unless otherwise indicated.
4. Ripple specification for dual output units applies to the voltage between the positive and negative output terminals.
5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output
XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product
changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details.
WWW.XPPOWER.COM