MVA-FIAM5BH-C [VICOR]
DC-DC Unregulated Power Supply Module, 1 Output, 560W, Hybrid, MODULE-29;型号: | MVA-FIAM5BH-C |
厂家: | VICOR CORPORATION |
描述: | DC-DC Unregulated Power Supply Module, 1 Output, 560W, Hybrid, MODULE-29 |
文件: | 总6页 (文件大小:399K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Military COTS 28 Vin Filter
MVA-FIAM5B
Model Number MVA-FIAM5BMC
Input Attenuator Module
Features
• EMI filtering-MIL-STD-461E(1)
• Transient protection-MIL-STD-704E/F
• Environments-MIL-STD-810, MIL-STD-202
• Environmental stress screening
• Output power up to 560 W
• Output current up to 20 A
• Inrush current limiting
• Cold plate mounting
Product Highlights
The MVA-FIAM5B is a DC front-end module
that provides EMI filtering and transient
protection. The MVA-FIAM5B enables
designers using Vicor’s Maxi, Mini, Micro
Series 24 V converters or VIPAC Arrays to
meet conducted emission / conducted
Absolute Maximum Rating
Parameter
Rating
36
Unit
Vdc
Vdc
Notes
Continuous
+In to –In
50
12.5 ms, See Fig.3
susceptibility per MIL-STD-461E; and input
transients per MIL-STD-704E/F. The MVA-
FIAM9 accepts an input voltage of 14 – 36
Vdc and delivers output power up to 560 W.
MTBF per MIL-HDBK-217F (MVA-FIAM5BM)
Temperature
25 °C
Environment
Ground Benign: G.B.
MTBF
2,430
437
Unit
1,000 Hrs
MVA-FIAM5B is mounted on a 4.69" x
3.62" coldplate with a height of 0.81” and
convenient input and output connectors.
50 °C
Naval Sheltered: N.S.
1,000 Hrs
65 °C
Airborne Inhabited Cargo: A.I.C.
343
1,000 Hrs
Compatible Products
• Maxi, Mini, Micro Series 24 V Input
DC-DC converters
• 24 V Input VIPAC Arrays
(1)EMI performance is subject to a wide
variety of external influences such as PCB
construction, circuit layout etc. As such,
external components in addition to those
listed herein may be required in specific
instances to gain full compliance to the
standards specified.
Part Numbering
MVA-FIAM5B
M
-
C
Product Grade Temperatures ( °C)
Grade Operating Storage
H = –40 to +100 –55 to +125
M = –55 to +100 –65 to +125
Blank = Standard
C = ON/OFF Control Enabled
Product
Military COTS 28 Vin Filter
Page 1 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
MVA-FIAM5B
SPECIFICATIONS
(typical at T = 25 °C, nominal line and 75% load, unless otherwise specified)
BP
INPUT SPECIFICATIONS
Parameter
Input voltage
Min
14
Typ
28
Max
36
Unit
Vdc
Notes
Continuous
Inrush limiting
Transient immunity
0.007
50
A/µF
Vdc
12.5 ms per MIL-STD-704E/F, continuous operation
Test conditions AA and FF normal overvoltage transients per
MIL-HDBK-704
OUTPUT SPECIFICATIONS
Parameter
Output current
Min
Typ
Max
20
Unit
A
Notes
Output power
560
W
Efficiency
96
98
%
Internal voltage drop
0.5
0.7
@20 A, 100 °C baseplate
External capacitance
See Figure 5 on page 4
50 V
330
1000
µF
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
ON/OFF control
Enable (ON)
0.0
3.5
1.0
5.0
Vdc
Vdc
Referenced to – Vout
Disable (OFF)
100 kΩ internal pull up resistor
SAFETYꢀSPECIFICATIONS
Parameter
Min
Typ
1,500
2,121
Max
Vrms
Vdc
Unit
Notes
Input / Output to Base
Dielectric withstand
Input / Output to Base
EMI
Standard
Test Procedure
Notes
MIL-STD-461E
Conducted emissions:
CE101, CE102
Conducted susceptibility:
CS101, CS114, CS115, CS116
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.
GENERALꢀSPECIFICATIONS
Parameter
Weight
Min
Typ
Max
0.7 (318)
2
Unit
Pounds (grams)
Years
Notes
Warranty
Military COTS 28 Vin Filter
Page 2 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
MVA-FIAM5B
SPECIFICATIONS (CONT.)
MODULE ENꢁIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
ꢁibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11 ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
MODULE ENꢁIRONMENTAL STRESS SCREENING
Parameter
H-Grade
M-Grade
Operating temperature
-40 °C to +100 °C
-55 °C to +100 °C
Storage temperature
-55 °C to +125 °C
-65 °C to +125 °C
12 cycles
-65 °C to +100 °C
12 cycles
-65 °C to +100 °C
Temperature cycling*
Ambient test @ 25 °C
Power cycling burn-in
Functional and parametric ATE tests
Hi-Pot test
Yes
12 hours, 29 cycles
-40 °C and +100 °C
Yes
Yes
24 hours, 58 cycles
-55 °C and +100 °C
Yes
Visual inspection
Yes
Yes
Test data
vicorpower.com
vicorpower.com
*Temperature cycled with power off, 17 °C per minute rate of change.
Military COTS 28 Vin Filter
Page 3 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
MVA-FIAM5B
Figure 1 — Shut Down Time of MVA-FIAM5B vs. Overvoltage
Figure 2 — Conducted Noise; MVA-FIAM5B and Model
V24A12M400B DC-DC converter operating at 28 Vdc, 400 W.
INPUT VOLTAGE
50 V
OUTPUT
VOLTAGE
INPUT CURRENT
Figure 4—Inrush Limiting: Inrush current with 1000 µF
Figure 3 — Transient Immunity: MVA-FIAM5B output
external capacitance, (C1 in Figure 5)
response to an input transient.
Note: The M-FIAM5 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
4700 pF
0.01 µF
+IN
+OUT
+S
+IN
PC
Maxi, Mini, Micro
24 Vdc Input
DC-DC Converter or
VIPAC Array
+OUT
F1
MOV P/N
MVA-
FIAM5B
0.2 µF
EMI
GND
ON/OFF
+OUT
SC
C1
30234-068
PR
–S
Input
–IN
–OUT
–IN
0.01 µF
4700 pF
Component Suggestions
Recommended Fuse: (F1) 20 A (max), Bussmann ABC style
Capacitance: (C1) 330 µF (min), 1000 µF (max)
Figure 5—Basic connection diagram with suggested Transient, Surge Protection and Recommended Reverse Polarity Protection.
Military COTS 28 Vin Filter
Page 4 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
MVA-FIAM5B
3.62
92,0
1.04
26,4
1.54
0.31
7,8
INCHES
MM
39,1
Output Connector
4.7
119,4
MVA – FIAM5B
ø 0.188 Thru
V90º to ø 0.332
(4) pl for #8 flat head
torque to 12 in-lb
Input Connector
0.19
0.81
20,6
4,82
1
10
20
1
9
11
10
18
Input Connector
Output Connector
Pin #
Function
Pin #
Function
Pin #
Function
1 – 4
–Vin
1
+Vout
10
+Vout
5 – 7
8
+Vin
NC
2
3
4
5
6
7
8
9
+Vout
+Vout
N/C
11
12
13
14
15
16
17
18
+Vout
+Vout
N/C
9
PE protective earth
PE protective earth
–Vin
10
N/C
N/C
11 – 13
14 – 17
18
N/C
On / Off
–Vout
–Vout
–Vout
+Vin
–Vout
–Vout
–Vout
NC
19
PE protective earth
PE protective earth
20
Input Mounting
ꢁicor P/N
Output Mounting
ꢁicor P/N
Connector
Connector
Housing
24795
24796
24828
Housing
25050
24796
25067
Pin
Kit
Pin
Kit
Note: The MVA-FIAM5BH and MVA-FIAM5BM are delivered with the On / Off control already configured as On using a 0 Ohm resistor on
the underside of the output connector board. The MVA-FIAM5BH-C and MVA-FIAM5BM-C are delivered without the 0 Ohm resistor
.
installed, allowing for user control of the On / Off functionality
Figure 6 — MVA-FIAM5B Packaging Option
Military COTS 28 Vin Filter
Page 5 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
MVA-FIAM5B
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Military COTS 28 Vin Filter
Page 6 of 6
Rev 1.2
vicorpower.com
800 735.6200
9/2012
相关型号: