MVA-FIAM9H [VICOR]

DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29;
MVA-FIAM9H
型号: MVA-FIAM9H
厂家: VICOR CORPORATION    VICOR CORPORATION
描述:

DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29

文件: 总6页 (文件大小:382K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Military COTS 28 Vin Filter  
MVA-FIAM9  
Input Attenuator Module  
Features  
EMI filtering-MIL-STD-461E(1)  
Transient protection-MIL-STD-704A/E/F,  
MIL-STD-1275A/B/D  
Environments-MIL-STD-810, MIL-STD-202  
Environmental stress screening  
Output power up to 500 W  
Output current up to 18 A  
Inrush current limiting  
Cold plate mounting  
Product Highlights  
Absolute Maximum Rating  
The MVA-FIAM9 is a DC front-end module  
that provides EMI filtering and transient  
protection. The MVA-FIAM9 enables  
designers using Vicor’s Maxi, Mini, Micro  
Series 24 V & Maxi Series 28 V DC-DC  
converters or VIPAC Arrays to meet conducted  
emission / conducted susceptibility per MIL-  
STD-461E; and input transients per MIL-  
STD-704A/E/F and MIL-STD-1275A/B/D.  
The MVA-FIAM9 accepts an input voltage  
of 10 – 36 Vdc and delivers output power up  
to 500 W.  
Parameter  
Rating  
36  
Unit  
Vdc  
Vdc  
Vdc  
Notes  
Continuous  
+In to –In  
See Fig.1  
50 mS,  
100  
250  
70 µs  
MTBF per MIL-HDBK-217F (MVA-FIAM9M)  
Temperature  
Environment  
MTBF  
3,379  
608  
Unit  
25 °C  
Ground Benign: G.B.  
Naval Sheltered: N.S.  
1,000 Hrs  
1,000 Hrs  
50 °C  
MVA-FIAM9 is mounted on a 4.69" x 3.62"  
coldplate with a height of 0.81” and  
65 °C  
Airborne Inhabited Cargo: A.I.C.  
476  
1,000 Hrs  
convenient input and output connectors.  
(1)EMI performance is subject to a wide  
variety of external influences such as PCB  
construction, circuit layout etc. As such,  
external components in addition to those  
listed herein may be required in specific  
instances to gain full compliance to the  
standards specified.  
Part Numbering  
MVA-FIAM9  
M
-
C
Product Grade Temperatures (°C)  
Blank = Standard  
Product  
C = ON/OFF Control Enabled  
Grade Operating  
Storage  
H = –40 to +100 55 to +125  
M = –55 to +100 65 to +125  
Military COTS 28 Vin Filter  
Page 1 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  
MVA-FIAM9  
SPECIFICATIONS  
(typical at T = 25 °C, nominal line and 75% load, unless otherwise specified)  
BP  
INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
36  
Unit  
Vdc  
A/µF  
Vdc  
Vdc  
Vdc  
Vdc  
Notes  
Input voltage  
10  
28  
Continuous  
Inrush limiting  
Transient immunity  
0.007  
100  
250  
70  
50 ms per MIL-STD-1275A/B/D, continuous operation  
70 µs per MIL-STD-1275A/B/D, continuous operation  
20 ms per MIL-STD-704A, continuous operation  
12.5 ms per MIL-STD-704E/F, continuous operation  
50  
OUTPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
500  
18  
Unit  
W
Notes  
Output power  
Output current  
A
Efficiency  
Internal voltage drop  
96  
97  
0.85  
%
V
1.5  
500 W, 25 °C baseplate  
External capacitance  
See Figure 5 on page 4  
50 V  
330  
1000  
µF  
CONTROL PIN SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
ON/OFF control  
Enable (ON)  
0.0  
3.5  
1.0  
5.0  
Vdc  
Vdc  
Referenced to – Vout  
Disable (OFF)  
100 kΩ internal pull up resistor  
SAFETY SPECIFICATIONS  
Parameter  
Min  
Typ  
1,500  
2,121  
Max  
Vrms  
Vdc  
Unit  
Notes  
Input/Output to Base  
Input/Output to Base  
Dielectric withstand  
EMI  
Standard  
Test Procedure  
Notes  
MIL-STD-461E  
Conducted emissions:  
When using with V28 series converters a 27 µH inductor is  
needed between the filter and converter for compliance  
below 30% of rated power.  
CE101, CE102  
Conducted susceptibility:  
CS101, CS114, CS115, CS116  
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components  
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.  
GENERAL SPECIFICATIONS  
Parameter  
Weight  
Min  
Typ  
Max  
0.7 (318)  
2
Unit  
Lbs (grams)  
Years  
Notes  
Warranty  
Military COTS 28 Vin Filter  
Page 2 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  
MVA-FIAM9  
SPECIFICATIONS (CONT.)  
MODULE ENVIRONMENTAL QUALIFICATION  
Altitude  
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.  
Explosive Atmosphere  
MIL-STD-810F, Method 511.4, Procedure I, Operational.  
Vibration  
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor  
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17  
with overall level of 7.7 G rms for 1 hour per axis.  
Shock  
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts / axis, 1,3,5 ft.  
MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.  
Acceleration  
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.  
Humidity  
MIL-STD-810F, Method 507.4.  
Solder Test  
MIL-STD-202G, Method 208H, 8 hour aging.  
MODULE ENVIRONMENTAL STRESS SCREENING  
Parameter  
H-Grade  
M-Grade  
Operating temperature  
Storage temperature  
-40 °C to +100 °C  
-55 °C to +125 °C  
-55 °C to +100 °C  
-65 °C to +125 °C  
12 cycles  
-65 °C to +100 °C  
12 cycles  
-65 °C to +100 °C  
Temperature cycling*  
Ambient test @ 25°C  
Power cycling burn-in  
Functional and parametric ATE tests  
Hi-Pot test  
Yes  
12 hours, 29 cycles  
-40 °C and +100 °C  
Yes  
Yes  
24 hours, 58 cycles  
-55 °C and +100 °C  
Yes  
Visual inspection  
Yes  
Yes  
Test data  
vicorpower.com  
vicorpower.com  
*Temperature cycled with power off, 17°C per minute rate of change.  
Military COTS 28 Vin Filter  
Page 3 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  
MVA-FIAM9  
Figure 1 — Transient Immunity: MVA-FIAM9 output response  
Figure 2 — Conducted Noise; MVA-FIAM9 and model  
to an input transient.  
V28A12M200B DC-DC converter operating at 28 Vdc, 200 W  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
-80  
-90  
2000  
1800  
1600  
1400  
1200  
1000  
800  
600  
400  
200  
30  
0.01  
0.1  
1
10  
0
Frequency (MHz)  
40  
50  
60  
70  
80  
90  
100  
CM Insertion Loss  
Vin (V)  
DM Insertion Loss  
Figure 3 — Shut down time of MVA-FIAM9 vs. Overvoltage  
Figure 4 — MVA-FIAM9 insertion loss  
Note:The MVA-FIAM9 is shown in the on state. To disable,  
open the connection between ON/OFF and –Out.  
4,700 pF  
0.01 µF  
+IN  
+OUT  
+S  
+IN  
Maxi, Mini, Micro  
24 Vdc or 28 Vdc Input  
DC-DC Converter  
PC  
+OUT  
F1  
Transorb P/N  
19180-510  
MVA-  
EMI  
GND  
0.2 µF  
ON/OFF  
SC  
Input  
C1  
FIAM9  
+OUT  
PR  
–S  
–IN  
–OUT  
–IN  
0.01 µF  
4,700 pF  
Component Suggestions  
Recommended Fuse: (F1) 20 A (max), Bussmann ABC style  
Capacitance: (C1) 330 µF (min), 1000 µF (max)  
Figure 5Transient, Surge Protection and Recommended Reverse Polarity Protection.  
Military COTS 28 Vin Filter  
Page 4 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  
MVA-FIAM9  
1
10  
20  
1
9
11  
10  
18  
Input Connector  
Output Connector  
Pin #  
Function  
Pin #  
Function  
Pin #  
Function  
1 – 4  
–Vin  
1
+Vout  
10  
+Vout  
5 – 7  
8
+Vin  
NC  
2
3
4
5
6
7
8
9
+Vout  
+Vout  
N/C  
11  
12  
13  
14  
15  
16  
17  
18  
+Vout  
+Vout  
NC  
9
PE protective earth  
PE protective earth  
–Vin  
10  
N/C  
NC  
11 – 13  
14 – 17  
18  
N/C  
On / Off  
–Vout  
–Vout  
–Vout  
+Vin  
–Vout  
–Vout  
–Vout  
NC  
19  
PE protective earth  
PE protective earth  
20  
Input Mating  
Vicor P/N  
Output Mating  
Vicor P/N  
Connector  
Housing  
Connector  
Housing  
24795  
24796  
24828  
25050  
24796  
25067  
Pin  
Kit  
Pin  
Kit  
Note: The MVA-FIAM9H and MVA-FIAM9M are delivered with the On / Off control already configured as On using a 0 Ohm resistor on the  
underside of the output connector board. The MVA-FIAM9H-C and MVA-FIAM9M-C are delivered without the 0 Ohm resistor installed,  
.
allowing for user control of the On / Off functionality  
Figure 6 — MVA-FIAM9 Outline and Pinouts  
Military COTS 28 Vin Filter  
Page 5 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  
MVA-FIAM9  
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and  
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom  
power systems.  
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no  
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make  
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and  
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls  
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of  
all parameters of each product is not necessarily performed.  
Specifications are subject to change without notice.  
Vicor’s Standard Terms and Conditions  
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.  
Product Warranty  
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the  
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment  
and is not transferable.  
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR  
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)  
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,  
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER  
MATTER.  
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable  
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes  
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and  
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and  
operating safeguards.  
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact  
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be  
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the  
product was defective within the terms of this warranty.  
Life Support Policy  
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS  
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support  
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform  
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the  
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the  
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products  
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.  
Intellectual Property Notice  
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the  
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is  
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.  
Vicor Corporation  
25 Frontage Road  
Andover, MA, USA 01810  
Tel: 800-735-6200  
Fax: 978-475-6715  
email  
Customer Service: custserv@vicorpower.com  
Technical Support: apps@vicorpower.com  
Military COTS 28 Vin Filter  
Page 6 of 6  
Rev 1.3  
vicorpower.com  
800 735.6200  
10/2012  

相关型号:

MVA-FIAM9H-C

DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29
VICOR

MVA-FIAM9M-C

DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29
VICOR
MMD